Transmission ultrasonography

Review of the results of the application of an advanced signal-processing technique, called time delay spectrometry, in obtaining soft tissue transmission images by transmission ultrasonography, both in vivo and in vitro. The presented results include amplitude ultrasound pictures and phase ultrasound pictures obtained by this technique. While amplitude ultrasonographs of tissue are closely analogous to X-ray pictures in that differential absorption is imaged, phase ultrasonographs represent an entirely new source of information based on differential time of propagation. Thus, a new source of information is made available for detailed analysis.

Heyser, R. C.↗

Geoscience instrumentation

Geoscience instrumentation systems are considered along with questions of geoscience environment, signal processing, data processing, and design problems. Instrument platforms are examined, taking into account ground platforms, airborne platforms, ocean platforms, and space platforms. In situ and laboratory sensors described include acoustic wave sensors, age sensors, atmospheric constituent sensors, biological sensors, cloud particle sensors, electric field sensors, electromagnetic field sensors, precision geodetic sensors, gravity sensors, ground constituent sensors, horizon sensors, humidity sensors, ion and electron sensors, magnetic field sensors, tide sensors, and wind sensors. Remote sensors are discussed, giving attention to sensing techniques, acoustic echo-sounders, gamma ray sensors, optical sensors, radar sensors, and microwave radiometric sensors.

Wolff, E. A.↗

Microelectronic fabrication of superconducting devices and circuits

It is expected that thin-film superconductors can be used as detectors or sources of infrared and microwave radiation, as magnetometers, as voltage standards, and for voltage and current measurements, for electronic signal processing, and in digital circuitry.

Kirschman, R. K.↗

Developments in the large angle oblique jet impingement flow investigation

Single-wire (hot-wire) measurements are presented of the mean velocity and turbulence quantities near the impact plate for a 45-degree impingement flow responsible for acoustic noise production. These results are summarized along with the conclusions which shaped the subsequent direction of the study of large angle oblique jet impingement flow. The development of a unique signal processing circuit for finding the instantaneous transverse vorticity from an array of four hot-wires is discussed.

Foss, J. F.↗

Application of acoustic surface wave technology to shuttle radar

The application of surface acoustic wave (SAW) signal processing devices in the space shuttle was explored. In order to demonstrate the functions which a SAW device might perform, a breadboard pulse compression filter (PCF) module was assembled. The PCF permits a pulse radar to operate with a large duty cycle and low peak power, a regime favorable to the use of solid state RF sources. The transducer design, strong coupling compensation, circuit model analysis, fabrication limitations, and performance evaluation of a PCF are described. The nominal value of the compression ratio is 100:1 with 10-MHz bandwidth centered at 60 MHz and 10-microsecond dispersive delay. The PCF incorporates dispersive interdigital transducers and a piezoelectric lithium niobate substrate.

Source record↗

A decametric wavelength radio telescope for interplanetary scintillation observations

A phased array, electrically steerable radio telescope (with a total collecting area of 18 acres), constructed for the purpose of remotely sensing electron density irregularity structure in the solar wind, is presented. The radio telescope is able to locate, map, and track large scale features of the solar wind, such as streams and blast waves, by monitoring a large grid of natural radio sources subject to rapid intensity fluctuation (interplanetary scintillation) caused by the irregularity structure. Observations verify the performance of the array, the receiver, and the scintillation signal processing circuitry of the telescope.

Cronyn, W. M.↗

CCD star trackers

The application of CCDs to star trackers and star mappers is considered. Advantages and disadvantages of silicon CCD star trackers are compared with those of image dissector star trackers. It is concluded that the CCD has adequate sensitivity for most single star tracking tasks and is distinctly superior in multiple star tracking or mapping applications. The signal and noise figures of several current CCD configurations are discussed. The basic structure of the required signal processing is described, and it is shown that resolution in excess of the number of CCD elements may be had by interpolation.

Goss, W. C.↗

Analysis of changes in leg volume parameters, and orthostatic tolerance in response to lower body negative pressure during 28-days exposure to zero gravity Skylab 2

The design of the leg volume measuring system employed for the M092 portion of the Skylab missions required the development of a system sensitive to large and small volume changes at the calf of the leg. These changes in volume were produced in response to the orthostatic stress of a Lower Body Negative Pressure Device (LBNPD) or by venous occlusion. The cardiovascular responses of the Apollo crewman associated with the postflight evaluations indicate varying decrements of orthostatic tolerance. The postflight changes indicate a slightly diminished ability of the cardiovascular system to function effectively against gravity following exposure to weightlessness. The objective of the Skylab LBNP experiments (M092) was to provide information about the magnitude and time course of the cardiovascular changes associated with prolonged periods of exposure to weightlessness. The equipment, signal processing, and analysis of the leg volume data obtained from the M092 experiment of the Skylab 2 Mission are described.

Barnett, R. D.↗

CO2 laser doppler systems for the measurement of atmospheric winds and turbulence

Two CO2 laser doppler systems developed by NASA and some results obtained with them are discussed. A continuous wave, monostatic system for short-range wind measurement is described, and direct comparisons between the data obtained with it and with a cup-anemometer/wind vane system and a hot-wire anemometer show excellent agreement between the systems. Improvements being made in three CW, CO2 laser doppler systems, including a filter bank for optimized signal processing and a versatile scanning system, are noted. A pulsed CO2 system for measuring clear air turbulence is described, and results of test performance on board a Convair 990 are presented. It is noted that while the system was able to measure air speed and turbulence, the range of its transmitter-atmosphere-receiver was lower than predicted, and a difference of about 20 to 30 dB existed between the actual and theoretical turbulence measurements. Factors that may account for this loss are listed.

Huffaker, R. M.↗

Hybrid measurement chains for the SAS-C spacecraft

Spacecraft electronic systems usually demand tight packaging. It was this consideration which initially forced us to consider hybrid circuits for the analog signal processing circuits in the Small Astronomy Satellite-C (SAS-C) scientific payload. We gradually discovered that increased reliability, low power consumption, and reduced program costs all followed. This paper will attempt to share our laboratory's first experience with hybrid circuits and indicate those areas which we found to be important.

Goeke, R. F.↗

Measurements of SO2 absorption coefficients using a tunable dye laser

High-resolution measurements of SO2 absorption coefficients in the UV are presented in the wavelength interval between 2962 and 3011 A using a frequency-doubled dye laser as the radiation source. These measurements have application to pollution monitoring of SO2 using the differential absorption scattering (DAS) technique. The spectral resolution of the measurements was 0.2 A (determined by the linewidth of the dye laser) and the generated spectra exhibited considerable rotational structure on the (000) double prime to (060) prime, (070) prime, and (080) prime electronic-vibrational transitions. The latter transitions correspond to center wavelengths of 3001.8, 2981.0, and 2962 A, respectively. The laser measurements were obtained with a signal-processing technique which eliminated calibration procedures associated with conventional optical-absorption measurements. Using this technique, the statistical uncertainty associated with measured absorption coefficients has been reduced to less than plus or minus 2% with a wavelength uncertainty of the laser source of plus or minus 0.1 A.

Thompson, R. T., Jr.↗

Auger electron spectroscopy at high spatial resolution and nA primary beam currents

An experimental Auger microprobe system is described which incorporates a field-emission electron gun and total beam currents in the nanoampere range. The distinguishing characteristics of this system include a large multistation UHV specimen chamber, pulse counting and fully digital Auger signal-processing techniques, and digital referencing methods to eliminate the effects of beam instabilities. Some preliminary results obtained with this system are described, and it is concluded that field-emission electron sources can be used for high-resolution Auger electron spectroscopy with primary-beam spots of less than 100 nm and beam currents of the order of 1 nA.

Todd, G.↗

Standard aerosols for particle velocimeters

System consists of laser-scattering counter (LSC) and photographic system. Photographic system provides absolute method of measuring aerosol size-distribution independently of their light scattering properties. LSC comprises 1-mW He/Ne laser, input optics, collecting optics, photodetector, and signal-processing electronics.

Deepark, A.↗

Analysis of changes in leg volume parameters, and orthostatic tolerance in response to lower body negative pressure during 59 days exposure to zero gravity Skylab 3

The cardiovascular responses of the Apollo crewmen associated with postflight evaluations indicate varying decrements of orthostatic tolerance. The postflight changes indicate a slightly diminished ability to the cardiovascular system to function effectively against gravity following exposure to weightlessness. The objective of the Skylab LBNP experiments (M092) was to provide information about the magnitude and time course of the cardiovascular changes associated with prolonged periods of exposure to weightlessness. This report details the equipment, signal processing and analysis of the leg volume data obtained from the M092 experiment of the Skylab 3 Mission.

Barnett, R. D.↗

A 20 Ghz Depolarization Experiment Using the ATS-6 Satellite

A depolarization experiment using the 20 GHz downlink from the ATS-6 satellite was described. The following subjects were covered: (1) an operational summary of the experiment, (2) a description of the equipment used with emphasis on improvements made to the signal processing receiver used with the ATS-5 satellite, (3) data on depolarization and attenuation in one snow storm and two rain storms at 45 deg elevation, (4) data on low angle propagation, (5) conclusions about depolarization on satellite paths, and (6) recommendations for the depolarization portion of the CTS experiment.

Bostian, C. W.↗

Laser Doppler spectrometer method of particle sizing

A spectrometer for the detection of airborne particulate pollution in the submicron size range is described. In this device, airborne particles are accelerated through a supersonic nozzle, with different sizes achieving different velocities in the gas flow. Information about the velocities of the accelerated particles is obtained with a laser-heterodyne optical system through the Doppler shift of light scattered from the particles. Detection is accomplished by means of a photomultiplier. Nozzle design and signal processing techniques are also discussed.

Weber, F. N.↗

Application of LSI to signal detection: The deltic DFPCC

The development of the DELTIC DFPCC serial mode signal processor is discussed. The processor is designed to detect in the presence of background noise a signal coded into the zero crossings of the waveform. The unique features of the DELTIC DFPCC include versatility in handling a variety of signals and relative simplicity in implementation. A theoretical performance model is presented which predicts the expected value of the output signal as a function of the input signal to noise ratio. Experimental results obtained with the prototype system, which was breadboarded with LSI, MSI and SSI components, are given. The device was compared with other LSI schemes for signal processing and it was concluded that the DELTIC DFPCC is simpler and in some cases more versatile than other systems. With established LSI technology, low frequency systems applicable to sonar and similar problems are feasible.

Gassaway, J. D.↗