Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science

We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.

47 OTHER INSTRUMENTATION↗

Modular Countermine Payload for Small Robots

Payloads for small robotic platforms have historically been designed and implemented as platform and task specific solutions. A consequence of this approach is that payloads cannot be deployed on different robotic platforms without substantial re-engineering efforts. To address this issue, we developed a modular countermine payload that is designed from the ground-up to be platform agnostic. The payload consists of the multi-mission payload controller unit (PCU) coupled with the configurable mission specific threat detection, navigation and marking payloads. The multi-mission PCU has all the common electronics to control and interface to all the payloads. It also contains the embedded processor that can be used to run the navigational and control software. The PCU has a very flexible robot interface which can be configured to interface to various robot platforms. The threat detection payload consists of a two axis sweeping arm and the detector. The navigation payload consists of several perception sensors that are used for terrain mapping, obstacle detection and navigation. Finally, the marking payload consists of a dual-color paint marking system. Through the multi-mission PCU, all these payloads are packaged in a platform agnostic way to allow deployment on multiple robotic platforms, including Talon and Packbot.

42 ENGINEERING↗

Path selection system development and evaluation for a Martian roving vehicle

A path selection system evaluation test procedure has been developed to enhance the analysis capability of an existing digital computer simulation package. The procedure investigates the obstacle avoidance ability of a path selection system on a sequence of test terrains with and without random effects. Using the standard test procedure a proposed mid-range sensor system has been evaluated and recommendations directed at improving the performance of the system have been made. In addition, the initial development and evaluation of a short range sensor system has been undertaken.

Campbell, R. S.↗

Coupling, Q-Factor, and Integration Aspects of Microsphere Applications

With suggested applications varying from microlaser and cavity QED through optical locking of diode lasers to modulators and sensors, high-Q silica microspheres with whispering-gallery (WG) modes so far remain the subject of tabletop feasibility demonstrations. Despite the uniquely high quality-factor and submillimeter dimensions suitable for tight packaging, this novel type of high-finesse cavity still has to be adapted to fiber- and integrated-optic hardware. In the visible and near infrared-band experiments (633-850nm) measuring the ringdown time tau of free oscillations, Q = (0.6 to 0.8 ) x 10(exp 10) has been obtained in silica spheres of diameter -800 microns (corresponding tau = 3 to 4 microseconds). It was proved that under normal laboratory conditions, quality-factor is subject to deterioration within several-minute scale down to (2 ... 3 ) x 10(exp 9). The responsible mechanism was identified as adsorption of a monolayer of atmospheric water, so that preservation of the ultimate Q requires manipulation in dry environment, or fast packaging into sealed devices. Larger Q can be expected closer to minimum of attenuation in fused silica alpha = 0.2 dB/km; Q greater than or equal to 1 x 10(exp 11) at lambda=1.55 microns, with corresponding energy storage time tau approx. 0.1ms. Experiments are currently underway to determine whether this high Q can be realized experimentally. The evident difficulty is that OH-related optical absorption has its peaks located near the reported minimum of attenuation in silica. We can also mention here that some of proposed fiber materials, yet not ready for fiber drawing, have been predicted to have smaller attenuation than fused silica and may be suitable for microsphere fabrication (sodium-magnesium silicate glass, alpha = 0.06dB/km). WG modes possess very small radiative loss (it does not prevent Q-10(exp 20) and more) and therefore are electromagnetically isolated and cannot be excited by free-space beams. If no modification (such as grating) is made on the sphere surface, the coupling has to he provided by an appropriate near-field device. A systematic theoretical approach has been recently developed to quantify the performance of near-field couplers for WG modes. Efficient coupling can be obtained upon fulfillment of two main conditions: (1) mode matching and (2) sufficient coupling strength to provide the buildup of a WG mode with a given intrinsic loss. In other words, the wave in the coupler has to be phase-matched and sufficiently overlapped with the WG mode to provide enough buildup in the cavity. If the coupling efficiency is characterized by the fractional depth K(sup 2) of the resonance dip in intensity transmittance observed upon varying the frequency of the exciting wave in the coupler.

Ilchenko, V. S.↗

GRACE KBR and Accelerometer Data Reduction and Calibration

The Gravity Recovery and Climate Experiment (GRACE), launched on March 17, 2002, represents the state-of-the-art in geodetic observations of the static and time varying components of the Earth's geopotential field. The fundamental measurement used to observe gravity is the inter-satellite range and range rate between two coplanar, low altitude satellites obtained from a K-band ranging (KBR) system. In addition to the K-band ranging system, each satellite possess a Super-STAR Accelerometer, a GPS receiver/antenna package, Star Cameras and a Laser Retro Reflector (LRR) to complete the compliment of science instruments. The GRACE project has now released two years of Level 1B data derived from the science instruments and sensors. An integral component of our time variable gravity research is the reduction, calibration and analyses of these Level 1B data. In particular we have analyzed several months of K-band ranging (KBR1B), accelerometry (ACC1B) and GPS navigation (GNAV1B) data. Accelerometer calibration and KBR data reduction methodology and results will be presented. We discuss the impact of these analyses on the recovery of time variable gravity.

Rowlands, David D.↗

Isolated post resonator mesogyroscope

A new symmetric vibratory gyroscope principle has been devised in which a central post proof mass is counter-rocked against an outer sensing plate such that the motion is isolated from the gyroscope case. Prototype gyroscopes have been designed and fabricated with micromachined silicon at mesoscale (20-cm resonator width), vs. microscale (e.g., 2-mm resonator width) to achieve higher sensitivity and machined precision. This novel mesogyro design arose out of an ongoing technical cooperation between JPL and Boeing begun in 1997 to advance the design of micro-inertial sensors for low-cost space applications. This paper describes the theory of operation of the mesogyro and relationships with other vibratory gyroscopes, the mechanical design, closed loop electronics design, bulk silicon fabrication and packaged gyroscope assembly and test methods. The initial packaged prototype test results are reported for what is believed to be the first silicon mesogyroscope.

mesogyroscope↗

Assembly Development for the Simons Observatory Focal Plane Readout Module

The Simons Observatory (SO) is a suite of instruments sensitive to temperature and polarization of the cosmic microwave background (CMB) to be located at Cerro Toco in the Atacama Desert in Chile. Five telescopes, one large aperture telescope and four small aperture telescopes, will host roughly 70,000 highly multiplexed transition edge sensor (TES) detectors operated at 100 mK. Each SO focal plane module (UFM) couples 1,764 TESes to microwave resonators in a microwave multiplexing (μMux) readout circuit. Before detector integration, the100 mKμMux components are packaged into multiplexing modules (UMMs), which are independently validated to ensure they meet SO performance specifications. Here we present the assembly developments of these UMM readout packages for mid frequency (90/150 GHz) and ultra high frequency (220/280 GHz) UFMs.

Aamir M. Ali↗

Small Inertial Measurement Units- Sources of Error and Limitations on Accuracy

Inertial measurement units (IMUs) with very low mass and power can be manufactured using micromachined accelerometers and gyroscopes. Six degree of freedom packages which require a few watts of power and have less than a kg of mass are available commercially, greatly expanding the potential applications of IMUs in guidance and navigation. Recent advances in small sensor design and fabrication have pushed the performance limits of these small devices. However, the limitations on the precision of small IMUs are not entirely due to the performance of the individual sensors.

Hoenk, Michael E.↗

BlueHat

"Bluehat" is a collection of python routines to facilitate the analysis of spectral (multispectral and hyperspectral) remote sensing imagery, with an emphasis on various kind of target detection. The package provides collections of utilities that developers can use in producing algorithms for specific target detection scenarios. Although "bluehat" is mostly expected to be used for remote sensing imagery (which often comes from satellite sensors), and although early versions of "bluehat" were used to design algorithms that were then rewritten for onboard processing; "bluehat" itself is not not specially designed for space and/or satellite application.

Theiler, James↗

State-of-the-Art Instrumentation Package to Support Model Organism Research in Space

Hardware was developed for the Ames student Fruit-Fly Experiment (AFEx) to support fly growth and analysis during spaceflight. The hardware consists of a 1.5U vented aluminum box that houses an acrylic habitat, video camera, LED lighting, and environmental sensors. Power is provided via two USB connectors, one of which also supports data downlink. While the hardware was designed for use with fruit flies, it will house plants on an upcoming mission and could be adapted for use with other systems.

Fruit-Fly Experiment↗

AI-powered municipal solid waste management: a comprehensive review from generation to utilization

The accumulation of municipal solid waste (MSW) continues to rise due to burgeoning population, rapid global urbanization and economic growth, intensifying ecological concerns associated with landfills and greenhouse gas (GHG) emissions. Over the past 2 decades, global waste generation has surged by 50%, with one-third remaining uncollected and about 70% sent to landfills. This review examines the critical role of integrating emerging technologies, such as advanced sensors and artificial intelligence (AI), into end-to-end MSW management to alleviate landfill burdens. The suitability of various AI tools for different stages of MSW management is assessed, alongside the deployment of advanced sensors including hyperspectral cameras, computer vision systems, and internet of things (IoT) devices for material identification. Applications of genetic algorithms and reinforcement learning for optimizing collection routes, reducing costs, and lowering emissions are highlighted. Life cycle assessment (LCA) across all stages of MSW management is also reviewed, along with future trends in leveraging generative AI, natural language processing (NLP), and agent-based AI systems to analyze waste generation patterns and public sentiment. Efficient collection and handling can be enhanced through route optimization with geographic information systems and real-time bin-level monitoring. Furthermore, sensor-embedded, real-time object detection systems paired with robotics enable material characterization and automated sorting, thereby lowering costs and diverting waste from landfills into value-added products for diverse industrial sectors including packaging, chemicals, textiles, metals and glass, transportation, and electronics industries. Without intervention, global waste is projected to reach 4.54 billion tons by 2050, contributing direct economic costs of $\$$400 billion and roughly 2.38 billion tons of CO 2 -equivalent emissions annually. This review demonstrates how AI-driven, end-to-end solutions for MSW management can mitigate economic and environmental challenges, while directly supporting the United Nations Sustainable Development (UNDP) goals related to innovation and infrastructure (SDG 9), sustainable cities (SDG 11), responsible consumption and production (SDG 12), and climate action (SDG 13).

09 BIOMASS FUELS↗

An extended BET format for La RC shuttle experiments: Definition and development

A program for shuttle post-flight data reduction is discussed. An extended Best Estimate Trajectory (BET) file was developed. The extended format results in some subtle changes to the header record. The major change is the addition of twenty-six words to each data record. These words include atmospheric related parameters, body axis rate and acceleration data, computed aerodynamic coefficients, and angular accelerations. These parameters were added to facilitate post-flight aerodynamic coefficient determinations as well as shuttle entry air data sensor analyses. Software (NEWBET) was developed to generate the extended BET file utilizing the previously defined ENTREE BET, a dynamic data file which may be either derived inertial measurement unit data or aerodynamic coefficient instrument package data, and some atmospheric information.

Findlay, J. T.↗

Measuring Water-Layer Thickness

Technique uses optical proximity detector. Detector consists of sensing probe, cartridge containing photocell and light source, and electronics package, housed in metal carrying case. Light transmitted from fiber-optic probe reflected by observed surface and transmitted back through probe to photoreceiver, output of which indicated on digital voltmeter or other suitable instrument. Sensor used to detect presence of bubbles or particles in water stream or to trigger alarm when condensing water becomes present in bottom of supposedly dry tank. Fiber-optic probes of sizes up to 0.285 in. (7.24 mm) with varying sensitivities and configurations available for use with system.

Faulcon, N.↗

Prospects for astrometry with the Hubble Space Telescope

The Hubble Space Telescope (HST), a large optical telescope having an aperture of 2.4 meters and a length of 8.8 meters, is being developed by NASA. This telescope will be placed into earth orbit by the Space Shuttle. Astrometric observations with the HST are made using a Fine Guidance Sensor which is capable of measuring the position of one object relative to another with an accuracy of + or - 0.002 arcseconds. The astrometric user of HST will be provided with an Astrometric Data Reduction Software package. The variety of astrometric problems to be investigated with HST is discussed.

Jefferys, W. H.↗

A new accelerometer recording system for shuttle use

Microgravity investigators are interested in enhancing the capabilities and improving the information return from accelerometers used in microgravity research. In addition to improving the accelerometer sensor, efforts should be directed towards using recent advances in microprocessor technology and system design techniques to improve sensor calibration and temperature compensation, online data display and analysis, and data reduction and information storage. Results from the above areas of investigation should be combined in an integrated design for a spaceflight microgravity accelerometer package.

Lichtenberg, Byron↗

Flight Results from the HST SM4 Relative Navigation Sensor System

On May 11, 2009, Space Shuttle Atlantis roared off of Launch Pad 39A enroute to the Hubble Space Telescope (HST) to undertake its final servicing of HST, Servicing Mission 4. Onboard Atlantis was a small payload called the Relative Navigation Sensor experiment, which included three cameras of varying focal ranges, avionics to record images and estimate, in real time, the relative position and attitude (aka "pose") of the telescope during rendezvous and deploy. The avionics package, known as SpaceCube and developed at the Goddard Space Flight Center, performed image processing using field programmable gate arrays to accelerate this process, and in addition executed two different pose algorithms in parallel, the Goddard Natural Feature Image Recognition and the ULTOR Passive Pose and Position Engine (P3E) algorithms

Naasz, Bo↗

Final Report on the Viability of Acoustic Techniques for Density and Mass Flow in Enrichment Plants

The primary purpose of this research is to study the viability of acoustic signatures and sensors that could support accurate, noninvasive, and unattended measurement of uranium hexafluoride (UF6) gas density and mass flow rate in situations representative of gaseous centrifuge enrichment plants (GCEP) under safeguards by the International Atomic Energy Agency. The measurement method under development can be readily retrofitted to the exterior of piping in existing systems, potentially facilitating acceptance by facility operators. The findings from the demonstration of a preliminary prototype design and first-generation analysis algorithms in this project will inform the safeguards community as to whether continued acoustic instrument and methods development are warranted. This project conducted two types of measurements, depending on the flow conditions of the gas. For static measurements, the focus is on understanding the acoustic properties at low pressure for non-flowing UF6. For flow measurements, the focus is on understanding the performance of the acoustic system in a simulation of a GCEP pipe using a surrogate gas under fully developed flow conditions. Testing with flowing UF6 was not considered because the cost of building a flowing UF6 system with flow similar to a GCEP was considerably greater than allocated project resources. This document summarizes the results of research conducted over the course of the project. Based on the results to date, the approach is seen to be promising with non-invasive acoustic measurements shown to be possible at the desired pressures. The project has demonstrated • 5% uncertainty of the UF6 gas density for static measurements at pressures relevant to GCEP operations over a 5-minute measurement window with a clear path forward to achieving considerably lower uncertainties over a two-hour period, • Measurements of flowing surrogate gases at pressures relevant to GCEP operations. However, additional research remains to be done to further develop the measurement approach and transition the technology for field use. These development needs include: • Understand the impact of flowing gas on gas density measurements, • Adding sensors and improving the measurement procedure, • Augmenting the data analysis methods by leveraging machine learning approaches, • Reevaluating uncertainty requirements for density and mass flow given observed Online Enrichment Monitor (OLEM) measurement uncertainties, • Designing a robust instrumentation package for field-testing, and • Evaluating measurement results to understand the potential impact on mass balance calculations within GCEP facilities.

42 ENGINEERING↗

Sensor data autonomy

'Smart' sensors onboard NASA space missions will require variable data output bandwidth as they respond to phenomena of interest. An Instrument Telemetry Packet (ITP) approach has been developed which encodes experimental instrument data into an autonomous data package, along with pertinent engineering parameters and ancillary data (time, position, attitude, etc.). New requirements for onboard concentration and buffering, as well as for end-to-end error control, arise from this approach. Emphasis is placed on packet protocols compatible with the data link standard ADCCP, to enable one set of ground support equipment to readily support instrument development, launch site checkout and mission operations phases.

Greene, E. P.↗