Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Segmental Urethral Dosimetry and Urinary Toxicity in Patients With No Urinary Symptoms Before Permanent Prostate Brachytherapy

Purpose: To determine whether segmental urethral dosimetry is predictive for the degree of urinary morbidity after prostate brachytherapy in patients with no urinary symptoms before prostate brachytherapy. Methods and Materials: Between May 2000 and November 2005, 1,107 patients underwent iodine-125 monotherapy with urethral sparing techniques. A total of 166 patients fulfilled the selection criteria: baseline (International Prostate Symptom Score) IPSS {<=}5, no androgen deprivation therapy, and prostate ultrasound planning volumes (PUTV) <45 mL. The median follow-up was 44 months. Urinary morbidity was defined by maximum increase in IPSS, time to IPSS resolution, maximum Radiation Therapy Oncology Group (RTOG) score, time to RTOG resolution, and urinary retention. Surrogate deviated urethra was contoured and doses calculated at the base, mid-prostate, apex, and urogenital diaphragm. Univariate and multivariate analysis was used to evaluate urethral and prostate dosimetry, age, PUTV, and number of needles for their association with urinary morbidity. Results: Urethral dose was fairly constant in all urethra segments except prostate base, where the variation in does was large. On multivariate analysis, higher urethral base D50, V100, and larger PUTV were predictive for higher maximum increase in IPSS. Higher urethral base V100 and larger PUTV predicted for prolonged IPSS resolution. Higher urethral base D50 and larger needle number predicted for longer RTOG resolution. Higher urethral base V100 predicted for RTOG {>=}2 toxicity. Conclusions: Radiation dose to the urethral base, larger PUTV, and needle number, predicted for increased urinary toxicity after prostate brachytherapy. Correlation between urinary morbidity and urethral base dosimetry may reflect a large variation in urethral dose observed at the prostate base.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Magnetic Resonance–Only Simulation: Segmentation of Bone in MR for Radiation Therapy Verification of the Head

Purpose: To develop a practical method to localize bones in magnetic resonance (MR) images, to create “computed tomography–like” MR images (ctMRI) that could be used for radiation therapy verification, and to generate MR-based digitally reconstructed radiographs (DRR). Methods and Materials: Using T1-weighted MR images, an air mask was derived from the manual contouring of all airways within the head and neck region using axial images at 6 anatomic levels. Compact bone, spongy bone, and soft tissue masks were then automatically generated using the statistical data derived from MR intensities and the air mask. ctMRI were then generated by mapping the MR intensities of the voxels within these masks into the CT number ranges of corresponding tissues. MR-based DRRs created from ctMRI were quantitatively evaluated using the co-registered MR and CT head images of 20 stereotactic radiosurgery patients. Ten anatomical points, positioned on the skull segmented using a threshold of 300 HU, in CT and ctMRI, were used to determine the differences in distance between MR-based DRRs and CT-based DRRs, and to evaluate the geometric accuracy of ctMRI and MR-based DRRs. Results: The bony structures were identified on ctMRI and were visible in the MR-based DRRs. From the 20 patient cases, the mean geometric difference and standard deviation between the 10 anatomical points on MR-based and CT-based DRRs was −0.05 ± 0.85 mm, respectively. This included uncertainty in image fusion. The maximum distance difference was 1.88 mm. Conclusions: A practical method was developed to segment bone from MR images. The ctMRI created can be used for radiation treatment verification when MR-only simulation is performed. MR-based DRRs can be used in place of CT-based DRRs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Auto-Segmentation to Reduce Contouring and Dose Inconsistency in Clinical Trials: The Simulated Impact on RTOG 0617

Contouring inconsistencies are known but understudied in clinical radiation therapy trials. We applied auto-contouring to the Radiation Therapy Oncology Group (RTOG) 0617 dose escalation trial data. We hypothesized that the trial heart doses were higher than reported due to inconsistent and insufficient heart segmentation. We tested our hypothesis by comparing doses between deep-learning (DL) segmented hearts and trial hearts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Segmentation, statistical analysis, and modelling of the wall system in ceramic foams

Closed walls in otherwise open foam structures may have a great impact on macroscopic properties of the materials. In this paper, we present two algorithms for the segmentation of such closed walls from micro-computed tomography images of the foam structure. The techniques are compared on simulated data and applied to tomographic images of ceramic filters. This allows for a detailed statistical analysis of the normal directions and sizes of the walls. Finally, we explain how the information derived from the segmented wall system can be included in a stochastic microstructure model for the foam.

36 MATERIALS SCIENCE↗

A Method to Automate the Segmentation of the GTV and ITV for Lung Tumors

Four-dimensional computed tomography (4D-CT) is a useful tool in the treatment of tumors that undergo significant motion. To fully utilize 4D-CT motion information in the treatment of mobile tumors such as lung cancer, autosegmentation methods will need to be developed. Using autosegmentation tools in the Pinnacle{sup 3} v8.1t treatment planning system, 6 anonymized 4D-CT data sets were contoured. Two test indices were developed that can be used to evaluate which autosegmentation tools to apply to a given gross tumor volume (GTV) region of interest (ROI). The 4D-CT data sets had various phase binning error levels ranging from 3% to 29%. The appropriate autosegmentation method (rigid translational image registration and deformable surface mesh) was determined to properly delineate the GTV in all of the 4D-CT phases for the 4D-CT data sets with binning errors of up to 15%. The ITV was defined by 2 methods: a mask of the GTV in all 4D-CT phases and the maximum intensity projection. The differences in centroid position and volume were compared with manual segmentation studies in literature. The indices developed in this study, along with the autosegmentation tools in the treatment planning system, were able to automatically segment the GTV in the four 4D-CTs with phase binning errors of up to 15%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Energy reconstruction of an n-type segmented inverted coaxial point-contact HPGe detector

We have characterized, for the first time, an n-type segmented Inverted Coaxial Point-Contact detector. This novel detector technology relys on a large variation in drift time of the majority charge carriers, as well as image and net charges observed on the segments, to achieve a potential γ-ray interaction position resolution of better than 1 mm. However, the intrinsic energy resolution in such a detector is poor (more than 20 keV at 1332 keV) because of charge (electron) trapping effects. We propose an algorithm that enables restoration of the resolution to a value of 3.44 0.03 keV at 1332 keV for events with a single interaction. The algorithm is based on a measurement of the azimuthal angle and the electron drift time of a given event; the energy of the event is corrected as a function of these two values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Segmented YSO scintillation detectors as a new β -implant detection tool for decay spectroscopy in fragmentation facilities

A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for β particles. A Position-Sensitive Photo-Multiplier Tube (PSPMT) is coupled with a 48 × 48 segmented YSO crystal. To demonstrate its capabilities, a known short-lived isomer in 76 Ni and the β decay of 74 Co were measured by implanting those ions into the YSO detector. The half-lives and γ-rays observed in this work are consistent with the known values. The β -ray detection efficiency is more than 80 % for the decay of 74 Co.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First experimental measurements with the Segmented Inverted-coaxial GerMAnium (SIGMA) detector

The SIGMA project aims to develop a p-type segmented inverted coaxial point contact germanium detector for gamma-ray tracking and imaging. Here the performance of the first prototype of this type of detector is reported. The measurements performed verified the size and shape of the crystal and determined the location of the complex active volumes of the detector segments. The latter determines the charge collection times that are related to the position of interaction. Good agreement is found between the results and the specified crystal design. The energy resolution of the point contact has been measured to be 0.84 keV and 2.21 keV at 122 keV and 1332 keV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nephron segment specific microRNA biomarkers of pre-clinical drug-induced renal toxicity: Opportunities and challenges

Drug-induced nephrotoxicity is a common drug development complication for pharmaceutical companies. Sensitive, specific, translatable and non-invasive biomarkers of renal toxicity are urgently needed to diagnose nephron segment specific injury. The currently available gold standard biomarkers for nephrotoxicity are not kidney-specific, lack sensitivity for early detection, and are not suitable for renal damage localization (glomerular vs tubulointerstitial injury). MicroRNAs (miRNAs) are increasingly gaining momentum as promising biomarkers of various organ toxicities, including drug induced renal injury. This is mostly due to their stability in easily accessible biofluids, ease of developing nucleic acids detection compared to protein detection assays, as well as their interspecies translatability. Increasing concordance of miRNA findings by standardizing methodology most suitable for their detection and quantitation, as well as characterization of their expression pattern in a cell type specific manner, will accelerate progress toward validation of these miRNAs as biomarkers in pre-clinical, and clinical settings. This review aims to highlight the current pre-clinical findings surrounding miRNAs as biomarkers in two important segments of the nephron, the glomerulus and tubules. - Highlights: • miRNAs are promising biomarkers of drug-induced kidney injury. • Summarized pre-clinical miRNA biomarkers of drug-induced nephrotoxicity. • Described the strengths and challenges associated with miRNAs as biomarkers.

60 APPLIED LIFE SCIENCES↗

An Analysis of Image Segmentation Time in Beam’s-Eye-View Treatment Planning

In this work we tabulate and histogram the image segmentation time for beam’s eye view (BEV) treatment planning in our center. The average time needed to generate contours on CT images delineating normal structures and treatment target volumes is calculated using a data base containing over 500 patients’ BEV plans. The average number of contours and total image segmentation time needed for BEV plans in three common treatment sites, namely, head/neck, lung/chest, and prostate, were estimated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Chain and Segmental Dynamics in Polymer–Nanoparticle Composites with High Nanoparticle Loading

Recent experimental and simulation studies have shown that polymer–nanoparticle (NP) composites (PNCs) with ultra-high NP loading (>50%) exhibit remarkable mechanical properties and dramatic increases in polymer glass-transition temperature, viscosity, and thermal stability compared to the bulk polymer. These deviations in macroscopic properties suggest a slowdown in both segmental and chain-scale polymer dynamics due to confinement. In this work, we examine the polymer conformations and dynamics in these PNCs using molecular dynamics simulations of both unentangled and entangled coarse-grained polymers in random-close-packed NP packings with varying polymer fill fractions. We find that the changes in the polymer dynamics depend on the number of NPs in contact with a polymer segment. Using the number of polymer–NP contacts and different polymer chain conformations as criteria for categorization, we further examine the polymer dynamics at multiple length scales to show the high level of dynamic heterogeneity in PNCs with ultra-high NP loading.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure, Dynamics, and Hydrogen Transport in Amorphous Polymers: An Analysis of the Interplay between Free Volume Element Distribution and Local Segmental Dynamics from Molecular Dynamics Simulations

Polymers are attractive membrane materials owing to their mechanical robustness and relatively inexpensive fabrication. An important indicator of membrane performance are free volume elements (FVE): microporous void spaces created by the inefficient packing of bulky groups along the polymer chain. FVEs tend to degrade over time, as polymer chains reorganize irreversibly. While it is widely accepted that polymer flexibility has an impact on membrane transport properties, the molecular nature of this impact is still not well understood. By the establishment of a correlation between local chain dynamics and the distribution of free volume elements (FVEs), penetrant transport can be regulated more efficiently in amorphous polymer membranes. In this work, we implement all-atom molecular dynamics (MD) simulations to explore the relationship between chain dynamics and free volume in three polymers with different levels of backbone flexibility: polymethylpentene (PMP), polystyrene (PS), and HAB-6FDA thermally rearranged polymer (TRP). We construct these polymers at different temperatures and examine how temperature impacts the FVE distribution and segmental mobility. Our analysis shows that chain segments near FVEs have higher mobility compared with the atoms in the bulk; the extent of this difference increases with chain flexibility. Increasing the chain flexibility by increasing the temperature results in a broader FVE distribution. Rigid polymers such as TRP show the most robust FVE distribution and are not significantly affected by the temperature change. To capture penetrant diffusion through the polymer matrix, hydrogen is inserted and the diffusion is measured at different temperatures; hydrogen mobility is influenced by the FVE structure and overall mobility of polymer chains. Lastly, at low temperatures, hydrogen mobility is influenced by void distribution, while at high temperatures, polymer dynamics dictate hydrogen transport.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlations between Salt-Induced Crystallization, Morphology, Segmental Dynamics, and Conductivity in Amorphous Block Copolymer Electrolytes

Block copolymer electrolytes have been shown to increase the cycle life of rechargeable batteries that utilize high capacity lithium anodes. Most block copolymer electrolyte studies have been centered on polystyrene-b-poly(ethylene oxide) (SEO) mixed with lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) salt and are limited to salt concentrations in the vicinity of r[Li]/[EO] = 0.1, where [Li] and [EO] are the concentration of lithium and ethylene oxide moieties, respectively, as the conductivity of poly(ethylene oxide) (PEO) homopolymer electrolytes is maximized at this concentration.Here, in this paper, we study the morphology and conductivity of electrolytes derived from a high molecular weight SEO block copolymer over the wide LiTFSI concentration range of 0 ≤ r ≤ 0.550. For electrolytes with r ≥ 0.125, the crystallization of PEO-LiTFSI complexes with stoichiometric ratios of 6:1, 3:1, or 2:1 (EO:Li) is shown to correlate with morphology as determined by small-angle X-ray scattering (SAXS) and scanning transmission electron microscopy (STEM): some samples that are semicrystalline at room temperature exhibit regions of periodic lamellar ordering, whereas those that do not crystallize have aperiodic packed-ellipsoid morphologies. SAXS profiles below and above the melting temperatures of the crystals are identical, indicating that the crystals are confined within the block copolymer domains. The conductivities of SEO/LiTFSI mixtures with r = 0.275, r = 0.300, and r = 0.350 are within experimental error of PEO/LiTFSI at the same salt concentrations, in spite of the presence of insulating polystyrene (PS) domains in the SEO/LiTFSI samples. We attribute this to enhanced segmental dynamics of the PEO chains in the SEO electrolytes, based on differential scanning calorimetry (DSC) measurements of glass transition temperatures. The dependence of ionic conductivity on salt concentration in the SEO/LiTFSI electrolytes at temperatures above the melting temperature of the crystalline complexes shows three local maxima that correlate with the formation of crystalline complexes when r ≥ 0.125. Finally, these maxima arise due to a combination of the enhanced segmental dynamics and changes in morphology observed by SAXS and STEM.

36 MATERIALS SCIENCE↗

The Role of Chain-End Association Lifetime in Segmental and Chain Dynamics of Telechelic Polymers

Broadband dielectric spectroscopy, differential scanning calorimetry, and rheology were employed to study the impact of hydrogen (H)-bonding end-groups on segmental and chain dynamics of telechelic polypropylene glycol (PPG) and poly(dimethylsiloxane) (PDMS). Polymer chains with three types of H-bonding end-groups possessing different interaction strengths and a non-H-bonding end-group as reference were compared. The glass transition temperature (Tg) of H-bonding PPG systems with low molecular weight increases compared to the reference, and the Tg difference varies with chain-end interaction strength. In contrast, their shear viscosities (for Tg-scaled temperature, i.e., when the shift in Tg is accounted for) are similar to that one of the reference. This is in strong contrast to the behavior of telechelic PDMS with the same set of end-groups, where the Tg increase of all H-bonding systems is independent of H-bond strengths, while shear viscosity increases significantly only for the strongest H-bonding end-groups. These observations are explained by the difference in lifetime of the end-group associations relative to segmental and chain relaxation times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mask-Assisted Seeded Growth of Segmented Metallic Heteronanostructures

Controlling the deposition of exotic metals in the seeded growth of multi-metal nanostructures is challenging. This work describes a seeded growth method assisted by a mask for synthesis of segmented binary or ternary metal nanostructures. Silica is used as a mask to partially block the surface of a seed and a second metal is subsequently deposited on the exposed area, forming a bimetallic heterodimer. The initial demonstration was carried out on a Au seed, followed by deposition of Pd or Pt on the seed. It was found that Pd tends to spread out laterally on the seed while Pt inclines to grow vertically into branched topology on Au. Without removal of the SiO₂ mask, Pt could be further deposited on the unblocked Pd of the Pd-Au dimer to form a Pt-Pd-Au trimer. The mask-assisted seeded growth provides a general strategy to construct segmented metallic nanoarchitectures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Controlled translocation of DNA segments through nanoelectrode gaps

Molecular dynamics simulations show that electrophoresis of DNA segments through a nanoscale electrode gap can be controlled by applying appropriate biased voltages in the transmembrane direction. The translocation velocities are dependent on both the DNA molecular weight and nucleotide structure. Application of alternating driving fields results in oscillatory motion of DNA inside the gap. Interruption of the driving field can effectively pause the translocation of DNA segments. Results from this work are useful for designing novel sequencing devices.

59 BASIC BIOLOGICAL SCIENCES↗

Chain and Segmental Dynamics of Poly(2-vinlylpyridine)

The influence of different oxide nanoparticles on segmental and chain dynamics of poly(2-vinylpyridine) is investigated by broadband dielectric spectroscopy (BDS), dynamic mechanical measurements, and calorimetry. While significant changes in rheological properties are observed with increasing nanoparticle loading, only weak effects are found in the glass transition temperature, the segmental mobility, and fragility. These results are discussed in the context of recent controversies in studies of polymer nanocomposites and polymer thin films.

Holt, Adam P↗

Dynamical Theory of Segmental Relaxation and Emergent Elasticity in Supercooled Polymer Melts

We generalize the force-level Elastically Collective Nonlinear Langevin Equation theory of supercooled molecular liquid dynamics to polymer melts based on mapping chains to disconnected and noninterpenetrating Kuhnsized spheres. This allows first-principles, no adjustable parameter calculations to be performed for the temperature-dependent mean segmental relaxation time of chemically diverse van der Waals polymers over a wide range of molecular weights. Despite the simplicity of the mapping, the theory does a good job of a priori predicting the glass transition temperature (T g ), the dynamic fragility, and full temperature dependence of the -relaxation time for some high molecular weight polymers and the chain length dependence of T g as the consequence of the molecular weight dependence of backbone stiffness. The minimalist model does not capture the unusually low and high fragilities of certain long chain polymers which are not typical of van der Waals molecular liquids. This seems likely due to the simple coarse graining adopted which ignores longer range chain connectivity and nonuniversal factors on the sub-Kuhn length scale. Elasticity, not of an entropic single chain origin, emerges in deeply supercooled polymer liquids due to transient segmental localization and is studied at the microscopic stress-tensor level. Calculations of the frequency-dependent dynamic storage modulus close to T g appear to be qualitatively consistent with recent measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗