Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sandia”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Robust Event Simulation Variants Endowed to Ns-3 for General Exploration

Sandia's ns-3 contributions are modifications to the open source ns-3 network simulator that enable simulation speedup. One improvement, for example, removes the need for simulating the transmission and receipt of packets between nodes that are too distant to actually be able to communicate. In large-scale simulations this optimization has shown significant gains in performance. Additional contributions will pave the way for parallel discrete simulation (PDES) in ns-3. SAND2020-12456 O Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Dickson, Joseph↗

Offshore Wind ENergy Simulation Toolkit (OWENS)

SAND2021-2751 O The Offshore Wind ENergy Simulation Toolkit (OWENS) is a collection of aerodynamic, structural, hydrodynamic, drivetrain, controls, composite structure and mesh preprocessing, and data postprocessing. OWENS is primarily an ontology, or glue code, pulling together many open-source and Sandia-developed libraries to model the aero-servo-hydro-elastic physics of wind and marine energy turbines. The toolkit’s intended use is for arbitrary aeroelastic rotor configurations analysis including vertical-axis wind turbines, horizontal-axis wind turbines, and analogous marine energy applications for fixed-bottom and floating configurations. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525

Owens, Brian↗

Mnemosyne

SAND2024-08570O Mnemosyne is an interactive tool for finding, retrieving, and exploring information about U.S. nuclear tests documented in the National Nuclear Security Administration’s NV-209 report. It also acts as an information architecture and codebase for integrating additional information and computational tools related to these tests at the unclassified and classified levels. Users can search by any number of nuclear test attributes—name, yield range, altitude ranges, purpose of a test—and find all matching tests. Users can also retrieve specific test information published in NV-209. The tool displays geospatial and topological data about test location, and it provides an information architecture for storing additional contextual material, such as photographs. Mnemosyne provides a capability of interfacing with HYCHEM, Sandia's nuclear detonation optical waveform tool. The software is designed for use by government, academia, military, and research institutions. The software will likely be advanced to integrate seismic data and the nuclear detonation optical signal simulation code radCTH. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Fisher, Dustin↗

STPPHAWKES

SAND2024-08541O STTPHAWKES software solution is a Bayesian estimation approach to a Hawkes process model that treats missing data as a latent variable in the estimation. The open-source software will be released to the R CRAN repository and Sandia National Labs’ Github. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rowe, Stephen↗

HyRAM+ (Hydrogen Plus Other Alternative Fuels Risk Assessment Models) v.5.1.1

HyRAM+ is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen and other alternative fuels infrastructure and transportation systems. HyRAM+ contains validated, simplified release behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM (hydrogen-only) versions 1.0 to 3.1 were developed by Sandia for the U.S. Department of Energy (DOE) Hydrogen and Fuel Cell Technologies Office (HFTO). The U.S. DOE Vehicle Technologies Office (VTO) and U.S. Department of Transportation (DOT) Pipeline and Hazardous Material Safety Administration (PHMSA) contributed to the development of HyRAM+ version 4.0 regarding the addition of methane (natural gas) and propane models. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-10862 O

Groth, Katrina↗

Prime VI

SAND2025-03757O Prime VI is a distribution-of-disease outbreak model calibration code based on variational inference. It accompanies a publication for submission to Statistics in Medicine journal, and the code will be maintained for open-source use on Sandia's GitLab. The software provides methods for calibrating an epidemiological model to measured case-count data for a multitude of correlated spatial regions. The code solves a Bayesian inverse problem for model calibration where the posterior over-model parameters are approximated through a custom implementation of variational inference. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Safta, Cosmin↗

Design of Temperature Dependent Critical Experiments with SPRF/CX

This paper describes the investigation of temperature-dependent critical experiments using the Seven Percent Critical Experiments (7uPCX) and Burnup Credit Critical Experiments (BUCCX) fuel types within the Sandia Pulsed Reactor Facility/Critical Experiments (SPRF/CX) apparatus at Sandia National Laboratories (Sandia). The goal of these experiments is to test the effect of varying system temperature on the $\kappa$ eff bias of water-moderated systems. Temperatures of 5–95°C were considered in this work. Eighteen representative lattice configurations were analyzed that had variations in the number of fuel rods and water holes, as well as in the array configuration, to achieve a variety of moderation regimes. The configurations were based on those detailed in the LEU-COMP-THERM-078 and LEU- COMP-THERM-079 experiments, both of which were published in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Corrective Action Management Unit Report of Post-Closure Care Activities Calendar Year 2019

The Corrective Action Management Unit (CAMU) at Sandia National Laboratories, New Mexico (SNL/NM) consists of a containment cell and ancillary systems that underwent closure in 2003 in accordance with the Closure Plan in Appendix D of the Class 3 Permit Modification (SNL/NM September 1997). The containment cell was closed with wastes in place. On January 27, 2015, the New Mexico Environment Department (NMED) issued the Hazardous Waste Facility Operating Permit (Permit) for Sandia National Laboratories (NMED January 2015) to the U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA) and its Management and Operating (M&O) contractor. The current M&O contractor is National Technology & Engineering Solutions of Sandia, LLC (NTESS). The Permit became effective February 26, 2015. The CAMU is undergoing post-closure care in accordance with the Permit, as revised and updated. This CAMU Report of Post-Closure Care Activities documents all activities and results for calendar year (CY) 2019, as required by the Permit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Behavioral Health/Employee Assistance. Interim Program Report FY 2020

The Sandia National Laboratories' (SNL) Corporate Behavioral Health Program is a workplace- based program that: 1) provides Employee Assistance Program (EAP) services including early identification and resolution of personal concerns which may impact job performance, 2) assists managers and the organization in addressing productivity issues, and 3) supports the SNL commitment to provide a safe and healthful work environment. The program is offered to approximately 13,500 employees in New Mexico. The Behavioral Health Program is a corporate program combining services in NM and CA. It is integrated with other occupational health and clinical services including disability, disease management and preventive health programs. In addition, Sandia's Behavioral Health Program provides critical management consultation and psychological assessment services for external organizations including Human Resources, the Department of Energy and Security through the Clinical Evaluation (CE) process, Human Reliability Program (HRP), Protective Force Program, Workplace Violence/Threat Assessment Team (TAT), and Insider Threat Working Group programs. The program supports Sandia National Laboratories' mission to safeguard national security, the environment, and the public; it is a proactive approach to early identification, intervention and assessment. Importantly, it reduces barriers to accessing mental health services and assists with reducing health care costs attributed to illness or injuries related to unhealthy lifestyles and behaviors. The team is comprised of a professional staff including a licensed Clinical Psychologist, a licensed professional clinical counselor (LPCC) and a licensed Marriage and Family counselor (MFT) who is also a Certified Employee Assistance Professional and who holds a doctorate in counseling psychology.

99 GENERAL AND MISCELLANEOUS↗

Application and Certification of Comparative Vacuum Monitoring Sensors for Structural Health Monitoring of 737 Wing Box Fittings

Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today's extensive fleet of aging aircraft and space vehicles. The use of in-situ sensors for real-time health monitoring of aircraft structures are a viable option to overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. Prevention of unexpected flaw growth and structural failure can be improved if on-board health monitoring systems are used to continuously assess structural integrity. Such systems are able to detect incipient damage before catastrophic failures occurs. Condition-based maintenance practices could be substituted for the current time-based maintenance approach. Other advantages of on-board distributed sensor systems are that they can eliminate costly, and potentially damaging, disassembly, improve sensitivity by producing optimum placement of sensors and decrease maintenance costs by eliminating more time- consuming manual inspections. This report presents a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Boeing, Delta Air Lines, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp. and the Federal Aviation Administration (FAA) carried out a certification program to formally introduce Comparative Vacuum Monitoring (CVM) as a structural health monitoring solution to a specific aircraft wing box application. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM into an airline maintenance program and the document revisions necessary to allow for routine use of CVM as an alternate means of performing periodic structural inspects. To carry out the validation process, knowledge of aircraft maintenance practices was coupled with an unbiased, independent evaluation. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically-relevant experimental effort to quantify the reliability of the CVM system applied to the Boeing 737 Wing Box fitting application. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for CVM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and also is acceptable to both the aviation industry and regulatory bodies. This report presents the use of several different statistical methods, some of them adapted from NDI performance assessments and some proposed to address the unique nature of damage detection via SHM systems, and discusses how they can converge to produce a confident quantification of SHM performance An important element in developing SHM validation processes is a clear understanding of the regulatory measures needed to adopt SHM solutions along with the knowledge of the structural and maintenance characteristics that may impact the operational performance of an SHM system. This report describes the major elements of an SHM validation approach and differentiates the SHM elements from those found in NDI validation. The activities conducted in this program demonstrated the feasibility of routine SHM usage in general and CVM in particular for the application selected. They also helped establish an optimum OEM-airline-regulator process and determined how to safely adopt SHM solutions. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM technology. It will also streamline the regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Xyce Parallel Electronic Simulator Users' Guide (Version 7.2)

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandias needs, including some radiation-aware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase - a message passing parallel implementation - which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows.

42 ENGINEERING↗

Dissertation Proposal: Innovations in Pulsed Power and Plasma Science Theory Simulation and Experiment

Pulsed power and plasma physics are topics of great study at both Sandia National Laboratories (SNL or Sandia) and the University of New Mexico (UNM). The goal of this research is to further knowledge and understanding of these fields using the resources of both SNL and UNM in three ways. The first way is through the comprehension, application, and testing of theory. Reading and analytically deriving theoretical solutions of problems both real-world and simplified will allow for a fresh perspective and the furthering of the theory. One such theory is Ottinger's generalized theory for voltage measurement in magnetically insulated transmission lines (MITLs). By working through the math, a deeper understanding of the theory is gained from which one may add more physically accurate and/or more detailed physics into the theory. Additionally, understanding the theory lays a good foundation from which one can analyze, test, and compare results to the theory in the following two ways that will advance the fields of pulsed power and plasma physics. The second way is through the modeling and simulation of real-world and simplified problems that utilize and test the afore mentioned theories. Theory can be applied to a simulation domain by using the unstructured time-domain electromagnetic (UTDEM) codes EMPHASIS and EMPIRE as well as the physical modeling software CUBIT, all of which were developed at SNL. Problems such as the modeling and design of the extended MITL on HERMES III, the understanding of space-charge-limited emission from vacuum cathodes, and the interaction between a relativistic electron beam and an ideal gas can all be modeled, simulated, and analyzed with this set of codes. Here the advantage is three-fold. Firstly, theory that describes our understanding of these problems can be put to the test and advanced through iterative simulation and analysis. Secondly, the understanding of these problems will have a positive impact on national security through the advancement of the technological capability of the United States of America. Thirdly, and not unrelated to the prior advantage, is the validation and verification of EMPIRE and EMPHASIS. This segues into the third way, which is through experiment and the comparison of experiment to simulated and theoretical results. Performing experimental comparisons completes the scientific method and grounds all of the work in reality. Being able to physically test theory and simulation is necessary for any real conclusions to be drawn. Another advantage for carrying out experimental work is to advance the physical testing capabilities of SNL. Several systems will be developed and tested through the course of this work that positively impact technological advancement of Sandia National Labs. Lastly, all of the above work will converge to yield a well-rounded perspective that ties the three categories of research together.

42 ENGINEERING↗

Xyce Parallel Electronic Simulator Users' Guide (V.7.1)

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: 1) Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. 2) A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. 3) Device models that are specifically tailored to meet Sandia's needs, including some radiation-aware devices (for Sandia users only). 4) Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase a message passing parallel implementation which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows.

42 ENGINEERING↗

The Grey Zone Test Range Integrated Urban Simulation Environment

Sandia National Laboratories is part of the government test and evaluation team for the Defense Advanced Research Projects Agency Collection and Monitoring via Planning for Active Situational Scenarios program. The program is designed to better understand competition in the area between peace and conventional conflict when adversary actions are subtle and difficult to detect. For the purposes of test and evaluation, Sandia conducted a range of activities for the program: creation of the Grey Zone Test Range; design of the data stream for a user experiment conducted with U.S. Indo-Pacific Command; design, implementation, and execution of the formal evaluation; and analysis and summary of the evaluation results. This report details Sandia's activities and provides additional information on the Grey Zone Test Range urban simulation environment developed to evaluate the performer technologies.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Abstracted, Modular, Ephemeral Autonomic Computing Systems Codified

The purpose of this report is to share work based on material originally described in a Sandia LDRD proposal for 2016 as well as an invention submission SD 14734 ( DOE # 150281) –“Abstracted, Modular, Ephemeral Autonomic Computing System(s) Codified” from April 2018. This work was done at Sandia National Laboratories, a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525

97 MATHEMATICS AND COMPUTING↗

Corrective Action Management Unit Report of Post-Closure Care Activities. Calendar Year 2020

he Corrective Action Management Unit (CAMU) at Sandia National Laboratories, New Mexico (SNL/NM) consists of a containment cell and ancillary systems that underwent closure in 2003 in accordance with the Closure Plan in Appendix D of the Class 3 Permit Modification (SNL/NM September 1997). The containment cell was closed with wastes in place. On January 27, 2015, the New Mexico Environment Department issued the Hazardous Waste Facility Operating Permit (Permit) for Sandia National Laboratories (NMED January 2015) to the U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA) and its Management and Operating (M&O) contractor. The current M&O contractor is National Technology & Engineering Solutions of Sandia, LLC (NTESS). The Permit became effective February 26, 2015. The CAMU is undergoing post-closure care in accordance with the Permit, as revised and updated. This CAMU Report of Post-Closure Care Activities documents all activities and results for calendar year (CY) 2020, as required by the Permit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of Comparative Vacuum Monitoring and Piezoelectric Sensors for Structural Health Monitoring of Rotorcraft Components

The costs associated with the increasing maintenance and surveillance needs of aging structures are rising at an unexpected rate. Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today’s extensive fleet of aging aircraft and space vehicles. Aircraft maintenance and repairs represent about a quarter of a commercial fleet’s operating costs. The application of Structural Health Monitoring (SHM) systems using distributed sensor networks can reduce these costs by facilitating rapid and global assessments of structural integrity. The use of in-situ sensors for real-time health monitoring can overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. The ease of monitoring an entire on-board network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. SHM systems also allow for condition-based maintenance practices to be substituted for the current time-based or cycle-based maintenance approach thus optimizing maintenance labor. The Federal Aviation Administration has conducted a series of SHM validation and certification programs intended to comprehensively support the evolution and adoption of SHM practices into routine aircraft maintenance practices. This report presents one of those programs involving a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Sikorsky, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp., Acellent Technologies Inc., and the Federal Aviation Administration (FAA) carried out a trial validation and certification program to evaluate Comparative Vacuum Monitoring (CVM) and Piezoelectric Transducers (PZT) as a structural health monitoring solution to specific rotorcraft applications. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM and PZT systems into rotorcraft maintenance programs and the document revisions necessary to allow for their routine use as an alternate means of performing periodic structural inspections. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically relevant experimental effort to quantify the reliability of a CVM system applied to Sikorsky S-92 fuselage frame application and a PZT system applied to an S-92 main gearbox mount beam application. The applications included both local and global damage detection assessments. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for SHM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and is acceptable to both the aviation industry and regulatory bodies. The validation work completed in this program demonstrated the ability of both CVM and PZT SHM systems to detect cracks in rotorcraft components. It proved the ability to use final system response parameters to provide a Green Light/Red Light (“GO” – “NO GO”) decision on the presence of damage. In additional to quantifying the performance of each SHM system for the trial applications on the S-92 platform, this study also identified specific methods that can be used to optimize damage detection, guidance on deployment scenarios that can affect performance and considerations that must be made to properly apply CVM and PZT sensors. These results support the main goal of safely integrating SHM sensors into rotorcraft maintenance programs. Additional benefits from deploying rotorcraft Health and Usage Monitoring Systems (HUMS) may be realized when structural assessment data, collected by an SHM system, is also used to detect structural damage to compliment the operational environment monitoring. The use of in-situ sensors for health monitoring of rotorcraft structures can be a viable option for both flaw detection and maintenance planning activities. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM and PZT technology. It will also streamline future regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Xyce Parallel Electronic Simulator Users' Guide (V. 7.3)

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel computing platforms (up to thousands of processors). This includes support for most popular parallel and serial computers; A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models; Device models that are specifically tailored to meet Sandia's needs, including some radiation-aware devices (for Sandia users only); Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase—a message passing parallel implementation—which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows.

42 ENGINEERING↗