Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Return”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

6S Return Samples: Assessment of Air Quality in the International Space Station (ISS) Based on Solid Sorbent Air Sampler (SSAS) and Formaldehyde Monitoring Kit (FMK) Analyses

The toxicological assessments of SSAS and FMK analytical results are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the SSAS tubes were 66-76% for 13C-acetone, 85-96% for fluorobenzene, and 73-89% for chlorobenzene. Post-flight flows were far below pre-flight flows and an investigation of the problem revealed that the reduced flow was caused by a leak at the interface of the pump inlet tube and the pump head. This resulted in degradation of pump efficiency. Further investigation showed that the problem occurred before the SSAS was operated on orbit and that use of the post-flight flows yielded consistent and useful results. Recoveries from formaldehyde control badges were 86 to 104%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). The T values will not be reported for these data due to the flow anomaly. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) is not efficiently trapped by the sorbents used in the SSAS. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. These five indices of air quality are summarized.

James, John T.↗

STS 133 Return Samples: Air Quality Aboard Shuttle (STS-133) and International Space Station (ULFS)

The toxicological assessments of 2 canisters (mini-GSC or GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The percent recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 Shuttle GSCs averaged 86, 100, and 87, respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration.

James, John T.↗

Radiation Modeling for the Reentry of the Hayabusa Sample Return Capsule

Predicted shock-layer emission signatures of the Japanese Hayabusa capsule during its reentry are presented for comparison with flight measurements made during an airborne observation mission using NASA s DC-8 Airborne Laboratory. For each altitude, lines of sight were extracted from flow field solutions computed using an inhouse high-fidelity CFD code, DPLR, at 11 points along the flight trajectory of the capsule. These lines of sight were used as inputs for the line-by-line radiation code NEQAIR, and emission spectra of the air plasma were computed in the wavelength range from 300 nm to 1600 nm, a range which covers all of the different experiments onboard the DC-8. In addition, the computed flow field solutions were post-processed with the material thermal response code FIAT, and the resulting surface temperatures of the heat shield were used to generate thermal emission spectra based on Planck radiation. Both spectra were summed and integrated over the flow field. The resulting emission at each trajectory point was propagated to the DC-8 position and transformed into incident irradiance. Comparisons with experimental data are shown.

Winter, Michael W.↗

DEPLOYTECH: Mars Sample Return Concept Study Delta Results

Agenda for this presentation is Exhaust options to reduce the launch numbers from 3 to 2: (1) Mass Reduction of Max-C Rover, ACO Orbiter, and or ACO ERS (2) Eliminate Max-C Rover (3) Launch vehicle options (4) Solar Sail for all interplanetary propulsion, chemical for maneuvering Goal would be to: (1) Brainstorm any other alternatives we have not considered (2) Eliminate any of the options listed above (3) Go forward with a possible viable option that is identified.

Russell, Tiffany↗

Development of the RANCOR Rotary-Percussive Coring System for Mars Sample Return

A RANCOR drill was designed to fit a Mars Exploration Rover (MER) class vehicle. The low mass of 3 kg was achieved by using the same actuator for three functions: rotation, percussions, and core break-off. Initial testing of the drill exposed an unexpected behavior of an off-the-shelf sprag clutch used to couple and decouple rotary-percussive function from the core break off function. Failure of the sprag was due to the vibration induced during percussive drilling. The sprag clutch would back drive in conditions where it was expected to hold position. Although this did not affect the performance of the drill, it nevertheless reduced the quality of the cores produced. Ultimately, the sprag clutch was replaced with a custom ratchet system that allowed for some angular displacement without advancing in either direction. Replacing the sprag with the ratchet improved the collected core quality. Also, premature failure of a 300-series stainless steel percussion spring was observed. The 300-series percussion spring was ultimately replaced with a music wire spring based on performances of previously designed rotary-percussive drill systems.

Paulsen, Gale↗

Trajectory Design for MoonRise: A Proposed Lunar South Pole-Aitken Basin Sample Return Mission

This paper presents the mission design for the proposed MoonRise New Frontiers mission: a lunar far side lander and return vehicle, with an accompanying communication satellite. Both vehicles are launched together, but fly separate low-energy transfers to the Moon. The communication satellite enters lunar orbit immediately upon arrival at the Moon, whereas the lander enters a staging orbit about the lunar Lagrange points. The lander descends and touches down on the surface 17 days after the communication satellite enters orbit. The lander remains on the surface for nearly two weeks before lifting off and returning to Earth via a low-energy return.

NASA's New Frontie↗

Seeking Signs of Life on Mars: A Strategy for Selecting and Analyzing Returned Samples from Hydrothermal Deposits

Highly promising locales for biosignature prospecting on Mars are ancient hydrothermal deposits, formed by the interaction of surface water with heat from volcanism or impacts. On Earth, they occur throughout the geological record (to at least approx. 3.5 Ga), preserving robust mineralogical, textural and compositional evidence of thermophilic microbial activity. Hydrothermal systems were likely present early in Mars' history, including at two of the three finalist candidate landing sites for M2020, Columbia Hills and NE Syrtis Major. Hydrothermal environments on Earth's surface are varied, constituting subaerial hot spring aprons, mounds and fumaroles; shallow to deep-sea hydrothermal vents (black and white smokers); and vent mounds and hot-spring discharges in lacustrine and fluvial settings. Biological information can be preserved by rapid, spring-sourced mineral precipitation, but also could be altered or destroyed by postdepositional events. Thus, field observations need to be followed by detailed laboratory analysis to verify potential biosignatures. See Attachment

Campbell, K. A.↗

Seeking the Signs of Life: Assessing the Presence of Biosignatures in the Returned Sample Suite

A biosignature (''definitive biosignature'' or DBS) is an object, substance and/or pattern whose origin specifically requires a biological agent. One category of DBS are complex organic molecules and/or structures whose formation and abundances relative to other compounds are virtually unachievable in the absence of life. A potential biosignature (PBS) is an object, substance and/or pattern that might have a biological origin and thus compels investigators to gather more data before reaching a conclusion as to the presence or absence of life. The usefulness of a PBS is determined not only by the probability that life created it but also by the improbability that nonbiological processes produced it. Because habitable planetary environments create nonbiological features that can mimic biosignatures, these environments must be characterized to the extent necessary to provide a context that is essential for confirming the presence of DBS. Environmental conditions also must have allowed biosignatures to be preserved and amenable to detection. Categories of biosignatures and their measurement requirements are indicated below.

Source record↗

Constraining Our Understanding of the Actions and Effects of Martian Volatiles Through the Study of Returned Samples

Volatiles have clearly played a key role in the evolution of Mars' atmosphere, hydrosphere and geosphere, with effects ranging from the geomorphological evidence for outflow channels and valley networks early in Mars' history to formation of alteration products in rocks to the current seasonal changes in the polar caps. It is clear that the absolute and relative abundances of various volatiles have changed through time via volcanic degassing, atmospheric loss, and interactions with the crust.

Source record↗