Total neutron emission generation and characterization for a Next Generation Safeguards Initiative spent fuel library
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
Despite covering a small portion of Earth’s surface, streams support a disproportionate amount of biodiversity. Here, we measure progress against the Global Biodiversity Framework 30×30 protection target for streams within the conterminous U.S., in terms of quantity, representation, and effectiveness of habitat protection under primarily land-based protection strategies. We evaluated the geophysical and biogeographical diversity of streams falling under protection measures. Additionally, we expose a paradox of streams being protected yet simultaneously impaired from human disturbances. Without considering impairment, approximately 30% of streams are currently protected through land-based conservation of their local or upstream watersheds; when considering impairment, only 9% to 28% of streams are truly protected from disturbances depending on impairment thresholds and protection criteria. Furthermore, despite protection approaching 30×30 targets, only 5% of the most prevalent physical stream habitat types are protected. We provide a targeted protection strategy, overcoming the impairment paradox and ensuring adequate representation of streams.
The THermally Evaporated Spray for Engineered Uniform particulateS (THESEUS) production platform was developed to generate highly uniform mixed actinide oxide particles.
Gamma-ray imaging is the most important way to identify unknown gamma-ray emitting objects in decommissioning, security, overcoming accidents. Over the past two decades a system for producing of gamma images in these conditions became more or less portable devices. But in recent years these systems have become the hand-held devices. This is very important, especially in emergency situations, and measurements for safety reasons. We describe the first integrated hand-held instrument for emergency and security applications. The device is based on the coded aperture image formation, position sensitive gamma-ray (X-ray) detector Medipix2 (detectors produces by X-ray Imaging Europe) and tablet computer. The development was aimed at creating a very low weight system with high angular resolution. We present some sample gamma-ray images by camera. Main estimated parameters of the system are the following. The field of view video channel ∼ 490 deg. The field of view gamma channel ∼ 300 deg. The sensitivity of the system with a hexagonal mask for the source of Cs-137 (Eg = 662 keV), is in units of dose D ∼ 100 mR. This option is less then order of magnitude worse than for the heavy, non-hand-held systems (e.g., gamma-camera Cartogam, by Canberra.) The angular resolution of the gamma channel for the sources of Cs-137 (Eg = 662 keV) is about 1.20 deg. (authors)
Reports on the vulnerability of the power grid. From wildfires, hurricanes, and floods to cyberattacks, the grid is vulnerable to natural and human-made disasters, which can cause widespread outages that last from hours to months and leave lasting economic impacts. Imagine a coastal region in the United States that has just been hit by a hurricane and lost all power. Besides the electricity infrastructure going out, communications networks, rail transportation, and gasoline pumps may also stop working after the emergency event, which often delays repair efforts to the grid. Unresponsive communications make it difficult to dispatch workers to repair the grid, and missing transportation links delay shipments of replacement equipment for the grid’s restoration.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
There is a renewed interest worldwide to promote the use of nuclear power. The long term successful use of nuclear power is critically dependent upon adequate and safe processing and disposition of the spent nuclear fuel. Liquid-liquid extraction is a separation technique commonly employed for the processing of the dissolved spent nuclear fuel. Our approach is based on the prerequisite that real time monitoring of the solvent extraction flowsheets provides unique capability to quickly detect unwanted manipulations with fissile isotopes present in the radiochemical streams during reprocessing activities. Our ability to identify material intentionally diverted from a liquid-liquid solvent extraction contactor system was successfully tested using on-line process monitoring. A chemical diversion and detection from a solvent extraction scheme was demonstrated using a centrifugal contactor system operating with the simulant PUREX extraction system of Nd(NO3)3/nitric acid aqueous phase and TBP/dodecane organic phase. A portion of the feed from a counter-current extraction system was diverted while a continuous extraction experiment was underway; the spectroscopic on-line process monitoring system was simultaneously measuring the feed, raffinate and organic products streams. The amount observed to be diverted by on-line spectroscopic process monitoring was in excellent agreement with values based from known mass of sample directly taken (diverted) from system feed solution. We conclude that real-time spectroscopic process monitoring would be a useful tool for the IAEA to detect the diversion of nuclear material in a timely manner. This poster summarizes our methodology of on-line process monitoring and shows recent results of specific examples.
This report summarizes the results for the market research survey of mass spectrometers that are deemed pertinent to International Atomic Energy Agency (IAEA) needs and strategic objectives. The focus of the report is on MS instruments that represent currently available (or soon to be) commercial off-the shelf (COTS) technology and weigh less than 400 pounds. A compilation of all available MS instruments (36 COTS and 2 R&D) is presented, along with pertinent information regarding each instrument.
Abstract not provided.
We have been very successful in measuring and analyzing actinides and actinide containing material for concentration ranges as low as 100 ppm to metal alloys. Several publications and LA-UR spectral line assignment references have been generated from this effort and listed below (1-6).
Explore the source record for details and available documents.
The spent fuel NDA project was started in 2009 to develop and test integrated technologies to improve NDA measurements of spent fuel assemblies.
A dual-particle imager (DPI) has been designed that is capable of detecting gamma-ray and neutron signatures from shielded SNM. The system combines liquid organic and NaI(Tl) scintillators to form a combined Compton and neutron scatter camera. Effective image reconstruction of detected particles is a crucial component for maximizing the performance of the system; however, a key deficiency exists in the widely used iterative list-mode maximum-likelihood estimation-maximization (MLEM) image reconstruction technique. For MLEM a stopping condition is required to achieve a good quality solution but these conditions fail to achieve maximum image quality. Stochastic origin ensembles (SOE) imaging is a good candidate to address this problem as it uses Markov chain Monte Carlo to reach a stochastic steady-state solution. The application of SOE to the DPI is presented in this work.
Magnetic Microcalorimeters (MMCs) are gamma-ray detectors with an energy resolution 10x higher than high-purity germanium detectors. They can improve nuclear data, enable the detection of new isotopes (e.g. Pu-242 of U-236), and increase the accuracy of non-destructive analysis of nuclear materials in cases where Ge detectors are limited by line overlap. MMCs consist of a magnetic sensor operated at temperatures below 50 mK, and they infer gamma-ray energies from the change in magnetization due to the temperature increase after gamma-ray absorption. The goal of this project is to further increase the energy resolution and sensitivity of MMC gamma detectors.
Fluid-fueled molten salt nuclear reactors (MSRs) have recently gained significant interest. As with all reactors, modeling and simulation are key factors for advanced reactor design and licensing and will be required for the deployment of MSRs. However, there are significant gaps between simulation capabilities and system behavior for MSRs. This paper presents a system model of an MSR based on the Molten Salt Demonstration Reactor. The model includes important physics specific to MSRs, such as fission product and tritium transport, as well as reactivity feedback.
LLNL will evaluate the performance of a stilbene-based scintillation detector array for IAEA neutron multiplicity counting (NMC) applications. This effort will combine newly developed modeling methodologies and recently acquired high-efficiency stilbene detector units to quantitatively compare the prototype system performance with the conventional He-3 counters and liquid scintillator alternatives.