Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Operation of the Fast Neutron Coincidence Collar (FNCL) with a DD-Neutron Generator

For more than 30 years, the quantitative assay of the 235 U content of light water reactor fresh fuel assemblies relied on measuring coincidence neutrons from fissions induced by an Am(Li) neutron source using 3 He based detectors. The Fast Neutron Collar (FNCL) developed by the International Atomic Energy Agency (IAEA), replaces traditional 3 He proportional counters with an array of liquid scintillator detectors arranged about the fuel assembly to provide improved measurement precision and reduced sensitivity to gadolinium poison rods. The FNCL relies on Am(Li) neutron sources that are no longer commercially available. This work examines the replacement of Am(Li) sources with a commercial off the-shelf deuterium–deuterium (DD) neutron generator. In addition to mitigating supply concerns, the neutron generator offers advantages in measurement precision and potential automation of sequential passive/active neutron measurements. This report presents the initial performance results for both the integrated DD/FNCL and Am(Li)/FNCL assays of compact depleted uranium, low-enriched uranium, and highly enriched uranium standards along with an estimate of the expected performance for fresh fuel assemblies. A discussion of the design and operation of the “FNCL Analysis and Simulation Software” is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A new magnetic spectrometer system for cosmic ray studies

The balloon flight prototype or a cosmic ray superconducting magnet experiment designed for operation on the Space Shuttle is described. The physical and operating parameters of the scintillation, Cerenkov, emulsion and multiwire proportional counters used in the system for charge and rigidity measurements is given as well as the on-board data handling procedures.

Golden, R. L.↗

The University of Chicago cosmic ray electrons and nuclei experiment on the H spacecraft

The University of Chicago instrument on the Heliocentric spacecraft (MEH experiment) will measure the energy spectrum of cosmic electrons in the range 5-400 MeV. In addition, the energy spectra and relative abundances of nuclei from protons to the iron group, with energies ranging from 30 MeV/n to 15 GeV/n, will be determined. Primary scientific objectives involve the study of the long and short term variability of these components as a probe of the structure of the heliosphere. Particles are identified by multiparameter analysis using the pulse height analyzed signals from eight active detectors - silicon solid state, plastic and crystal scintillators are solid and gas Cerenkov counters. Data return is optimized by a three level priority logic scheme.

Meyer, P.↗

Cosmic ray detectors

Work on the MSFC emulsion laboratory microscopes in which mechanical modifications previously made were verified is reviewed, as is a design study of a large area hybrid electronic/emulsion chamber balloon flight detector system. This design is built upon the experience obtained with the highly successful MSFC/UAH hybrid instrument flown by the JACEE consortium. The design included overall system design and specification, design and fabrication of a prototype large light diffusion for Cerenkov charge detector or scintillator, design of a multiwire proportional counter array and design of the gondola or flight support system.

Gregory, John C.↗

A program to study antiprotons in the cosmic rays: Arizona collaboration

The Low Energy AntiProton (LEAP) experiment was designed to measure the primary antiproton flux in the 200 MeV to 1 GeV kinetic energy range. A superconducting magnetic spectrometer, a time-of-flight (TOF) detector, and a Cherenkov counter are the main components of LEAP. An additional scintillation detector was designed and constructed to detect the passage of particles through the bottom of the Cherenkov counter. The LEAP package was launched on August 22, 1987, and enjoyed a 27 hour flight, with 23 hours of data at high altitude. Preliminary plans for data analysis include using the Micro-Vax at the University of Arizona for data reduction of the Cherenkov and S2 signals.

Bowen, Theodore↗

Electron Calorimeter Experiment

Boron loaded scintillators are suitable for measuring secondary neutrons produced by high-energy particles: protons & electrons Neutron flux can be used to discriminate hadron and electro-magnetic particles Combined effectiveness of all e/p discriminators techniques employedTBD Only moderate improvement in detection efficiency for B-10 concentrations >few% in thick moderators Bottom scintillator might serve as cascade penetration counter (TBC)

Adams, James H.↗

Neutron Measurements for Radiation Protection in Low Earth Orbit - History and Future

The neutron environment inside spacecraft has been of interest from a scientific and radiation protection perspective since early in the history of manned spaceflight. With 1:.1e exception of a few missions which carried plutonium-fueled radioisotope thermoelectric generators, all of the neutrons inside the spacecraft are secondary radiations resulting from interactions of high-energy charged particles with nuclei in the Earth's atmosphere, spacecraft structural materials, and the astronaut's own bodies. Although of great interest, definitive measurements of the spacecraft neutron field have been difficult due to the wide particle energy range and the limited available volume and power for traditional techniques involving Bonner spheres. A multitude of measurements, however, have been made of the neutron environment inside spacecraft. The majority of measurements were made using passive techniques including metal activation fo ils, fission foils, nuclear photoemulsions, plastic track detectors, and thermoluminescent detectors. Active measurements have utilized proton recoil spectrometers (stilbene), Bonner Spheres eRe proportional counter based), and LiI(Eu)phoswich scintillation detectors. For the International Space Station (ISS), only the plastic track! thermoluminescent detectors are used with any regularity. A monitoring program utilizing a set of active Bonner spheres was carried out in the ISS Lab module from March - December 200l. These measurements provide a very limited look at the crew neutron exposure, both in time coverage and neutron energy coverage. A review of the currently published data from past flights will be made and compared with the more recent results from the ISS. Future measurement efforts using currently available techniques and those in development will be also discussed.

Golightly, M. J.↗

Recent Developments in Fast Neutron Detection and Multiplicity Counting with Liquid Scintillator

For many years, LLNL researchers have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of the techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, thermal neutron detectors (mainly {sup 3}He) were used, taking advantage of the high thermal neutron interaction cross sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics that respond over 1000 times faster (ns versus tens of {mu}s) than thermal neutron detectors. Fast neutron detection offers considerable advantages since the inherent ns production timescales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Obtaining supernova directional information using the neutrino matter oscillation pattern

A nearby core collapse supernova will produce a burst of neutrinos in several detectors worldwide. With reasonably high probability, the Earth will shadow the neutrino flux in one or more detectors. In such a case, for allowed oscillation parameter scenarios, the observed neutrino energy spectrum will bear the signature of oscillations in Earth matter. Because the frequency of the oscillations in energy depends on the path length traveled by the neutrinos in the Earth, an observed spectrum also contains information about the direction to the supernova. We explore here the possibility of constraining the supernova location using matter oscillation patterns observed in a detector. Good energy resolution (typical of scintillator detectors), well-known oscillation parameters, and optimistically large (but conceivable) statistics are required. Pointing by this method can be significantly improved using multiple detectors located around the globe. Although it is not competitive with neutrino-electron elastic scattering-based pointing with water Cherenkov detectors, the technique could still be useful.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron pileup algorithms for multiplicity counters

Abstract The shortage of helium-3 (3He) has created a need to identify alternative neutron detection options for a variety of nuclear nonproliferation applications. One application that may be affected by 3He replacement technology is that of mass accountancy for safeguards, which utilizes coincidence and multiplicity counters to verify special nuclear material declarations. The use of neutron scintillation materials, such as LiF-ZnS sheets, as an alternative to 3He proportional tubes in multiplicity counters requires novel techniques for Pulse Shape Discrimination to distinguish between neutrons and gamma rays. These techniques must work under high count rates, as the maximum momentary rate for incoming neutrons from multiplicity events can be quite large. We have created a fast and accurate neutron discrimination algorithm based on time window filtering and signature comparison that can operate quickly on data with high degrees of gamma ray and neutron pileup. This algorithm is evaluated for its capability to separate signals as the pileup rate increases, and the possibility for implementation on fast hardware (e.g., FPGA hardware) for real-time operation is explored.

Robinson, Sean M.↗

Performance of Large Neutron Detectors Containing Lithium-Gadolinium-Borate Scintillator

This paper describes the development and testing of a neutron counter, spectrometer, and dosimeter that is compact, efficient, and accurate. A self-contained neutron detection instrument has wide applications in health physics, scientific research, and programs to detect, monitor, and control strategic nuclear materials (SNM). The 1.3 liter detector head for this instrument is a composite detector with an organic scintillator containing uniformly distributed {sup 6}Li{sub 6}{sup nat}Gd{sup 10}B{sub 3}O{sub 9}:Ce (LGB:Ce) microcrystals. The plastic scintillator acts to slow impinging neutrons and emits light proportional to the energy lost by the neutrons as they moderate in the detector body. Moderating neutrons that have slowed sufficiently capture in one of the Lithium-6, Boron-10, or Gadolinium-157 atoms in the LGB:Ce scintillator, which then releases the capture energy in a characteristic cerium emission pulse. The measured captured pulses indicate the presence of neutrons. When a scintillating fluor is present in the plastic, the light pulse resulting from the neutron moderating in the plastic is paired with the LGB:Ce capture pulse to identify the energy of the neutron. About 2% of the impinging neutrons lose all of their energy in a single collision with the detector. There is a linear relationship between the pulse areas of this group of neutrons and energy. The other 98% of neutrons have a wide range of collision histories within the detector body. When these neutrons are 'binned' into energy groups, each group contains a distribution of pulse areas. This data was used to assist in the unfolding of the neutron spectra. The unfolded spectra were then validated with known spectra, at both neutron emitting isotopes and fission/accelerator facilities. Having validated spectra, the dose equivalent and dose rate are determined by applying standard, regulatory damage coefficients to the measured neutron counts for each energy bin of the spectra. Testing at the Los Alamos Neutron Science Center (LANSCE), Edwards Accelerator Laboratory (EAL) at Ohio University and the Radiation Center at University of Massachusetts-Lowell has demonstrated that the instrument can measure neutrons and their spectra over the range between 0.8 MeV and 150 MeV with an uncertainty of only ± 8%. An independent test of the LGB:Ce neutron spectrometer was conducted by a US Defense Threat Reduction Agency (DTRA) team at the Idaho National Laboratory (INL). The results of this evaluation showed that the neutron spectrometer accurately identified bare radioactive isotopes by their spectra. Further, masking and shielding materials alter those spectra in predictable ways that permit an extrapolation from the observed spectra back to the identity of the isotopic spectrum. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dense Plasma Focus as Collimated Source of D-D Fusion Neutron Beams for Irradiation Experiences and Study of Emitted Radiations

A 'table-top' 2 kJ, 250 kA plasma focus, the PACO (Plasma AutoConfinado), designed by the Dense Plasma Group of IFAS is used in its optimum regime for neutron yield for obtaining collimated pulsed neutron beams (100 ns). A simple and low-cost shielding arrangement was developed in order to fully eliminate the 2.45 MeV neutrons generated in the PACO device (10{sup 8} per shot at 31 kV, 1-2 mbar). Conventional neutron diagnostics: scintillator-photomultiplier (S-PMT), silver activation counters (SAC), etc., are used to determine the minimum width of the shielding walls. Emission of very hard electromagnetic pulses is also studied. Collimation using lead and copper plates is made to determine the localization of the very hard X-ray source. The maximum energy of the continuum photon distribution is estimated in 0,6 MeV using a system of filters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement and modeling of muon-induced neutrons in LSM in application for direct dark matter searches

Due to a very low event rate expected in direct dark matter search experiments, a good understanding of every background component is crucial. Muon-induced neutrons constitute a prominent background, since neutrons lead to nuclear recoils and thus can mimic a potential dark matter signal. EDELWEISS is a Ge-bolometer experiment searching for WIMP dark matter. It is located in the Laboratoire Souterrain de Modane (LSM, France). We have measured muon-induced neutrons by means of a neutron counter based on Gd-loaded liquid scintillator. Studies of muon-induced neutrons are presented and include development of the appropriate MC model based on Geant4 and analysis of a 1000-days measurement campaign in LSM. We find a good agreement between measured rates of muon-induced neutrons and those predicted by the developed model with full event topology. The impact of the neutron background on current EDELWEISS data-taking as well as for next generation experiments such as EURECA is briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. As a result, the completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of relativistic rise in ionization chambers for measurement of high energy heavy nuclei

A balloon-borne instrument has been constructed to measure the energy spectra of cosmic-ray heavy nuclei in the range of about 0.3 to about 100 GeV/amu. It makes use of the relativistic rise portion of the Bethe-Bloch curve in ionization chambers for energy determination in the 10- to 100-GeV/amu interval. The instrument consists of six layers of dual-gap ionization chambers for energy determination above 10 GeV/amu. Charge is determined with a NE114 scintillator and a Pilot 425 plastic Cerenkov counter. A CO2 gas Cerenkov detector (1 atm; threshold of 30 GeV/amu) calibrates the ion chambers in the relativistic rise region. The main emphasis of the instrument is the determination of the change of the ratio of Iron (26) to the Iron secondaries (21-25) in the energy range of 10 to 100 GeV/amu. Preliminary data from a balloon flight in the fall of 1982 from Palestine, TX is presented.

Barthelmy, S. D.↗

Cosmic Ray Nuclei (CRN) detector investigation

The Cosmic Ray Nuclei (CRN) detector was designed to measure elemental composition and energy spectra of cosmic radiation nuclei ranging from lithium to iron. CRN was flown as part of Spacelab 2 in 1985, and consisted of three basic components: a gas Cerenkov counter, a transition radiation detector, and plastic scintillators. The results of the experiment indicate that the relative abundance of elements in this range, traveling at near relativistic velocities, is similar to those reported at lower energy.

Meyer, Peter↗

A statistical rain attenuation prediction model with application to the advanced communication technology satellite project. 3: A stochastic rain fade control algorithm for satellite link power via non linear Markow filtering theory

The dynamic and composite nature of propagation impairments that are incurred on Earth-space communications links at frequencies in and above 30/20 GHz Ka band, i.e., rain attenuation, cloud and/or clear air scintillation, etc., combined with the need to counter such degradations after the small link margins have been exceeded, necessitate the use of dynamic statistical identification and prediction processing of the fading signal in order to optimally estimate and predict the levels of each of the deleterious attenuation components. Such requirements are being met in NASA's Advanced Communications Technology Satellite (ACTS) Project by the implementation of optimal processing schemes derived through the use of the Rain Attenuation Prediction Model and nonlinear Markov filtering theory.

Manning, Robert M.↗

Observation of EAS using a large water tank

Using a large water tank (30 m in diameter, 4.5 m in depth) transition of extensive air showers (EAS) was investigated at Taro (200 m above sea level). There are set 150,0.4 sq m proportional counters on the bottom of the water tank. A conventional EAS array of 25 plastic scintillation detectors was arranged within several tens meter from the water tank. A proportional counter (10x10x200 cc x2) is made of a square shaped pipe of iron. Tungsten wire (100 mu m phi) is stretched tight in the center of the counter. A gas mixture of 90% argon and 10% methane is used at 760 mmHg. About 3000 EAS were obtained through 1 m of water since 1984.

Inoue, K.↗