Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

NASA Tech Briefs, June 2009

Topics covered include: Device for Measuring Low Flow Speed in a Duct, Measuring Thermal Conductivity of a Small Insulation Sample, Alignment Jig for the Precise Measurement of THz Radiation, Autoignition Chamber for Remote Testing of Pyrotechnic Devices, Microwave Power Combiners for Signals of Arbitrary Amplitude, Synthetic Foveal Imaging Technology, Airborne Antenna System for Minimum-Cycle-Slip GPS Reception, Improved Starting Materials for Back-Illuminated Imagers, Multi-Modulator for Bandwidth-Efficient Communication, Some Improvements in Utilization of Flash Memory Devices, GPS/MEMS IMU/Microprocessor Board for Navigation, T/R Multi-Chip MMIC Modules for 150 GHz, Pneumatic Haptic Interfaces, Device Acquires and Retains Rock or Ice Samples, Cryogenic Feedthrough Test Rig, Improved Assembly for Gas Shielding During Welding or Brazing, Two-Step Plasma Process for Cleaning Indium Bonding Bumps, Tool for Crimping Flexible Circuit Leads, Yb14MnSb11 as a High-Efficiency Thermoelectric Material, Polyimide-Foam/Aerogel Composites for Thermal Insulation, Converting CSV Files to RKSML Files, Service Management Database for DSN Equipment, Chemochromic Hydrogen Leak Detectors, Compatibility of Segments of Thermoelectric Generators, Complementary Barrier Infrared Detector, JPL Greenland Moulin Exploration Probe, Ultra-Lightweight Self-Deployable Nanocomposite Structure for Habitat Applications, and Room-Temperature Ionic Liquids for Electrochemical Capacitors.

Source record↗

Developing Quantum Levitation of ICF Capsules Coated with MgB 2 Thin Films

Current inertial confinement fusion (ICF) capsule support technologies create implosion perturbations which reduce fusion yield, driving the search for new support paradigms. Quantum levitation of the capsule will eliminate the requirement of a physical support structure, increasing fusion yield. The application of an external magnetic field to a capsule coated with a superconducting film can provide the necessary conditions for levitation. Magnesium diboride (MgB 2 ) is an attractive option for ICF applications as it has a high reported superconducting transition temperature of 39 K and is a low Z compound. This project is part of an ongoing effort which seeks to coat ICF capsules with a thin layer of superconducting MgB 2 . This project studied the synthesis of MgB 2 and diffusion/reaction kinetics of B/Mg/B m ultilayer thin films. These films were sputter deposited on flat glassy carbon substrates. Films were annealed in a tube furnace at temperatures between 400 °C and 650 °C for a total of 29 hours with film characterization done at predetermined intervals. At each interval, superconducting properties of the samples were evaluated with superconducting quantum interference device (SQUID) magnetometry, while Rutherford backscattering (RBS) with 2 MeV 4 He + ions was done to determine the composition and depth profile of the films. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used to characterize surface morphology. Superconducting behavior was observed in thin films annealed at and above 450 °C. Formation of superconducting MgB 2 at 450 °C h as not been previously reported below 500 °C. The surface of the samples annealed at 500 °C and below was smooth with a measured roughness of ~3 nm. After 29 hours of annealing time, the 450 °C sample had a transition temperature of 27.3 K. The highest transition temperature measured was 30.9 K and was associated with a sample annealed for 29 hours at 650 °C. Transition temperatures were weakly positively correlated with annealing temperature and showed dependence on initial structural quality and oxygen contamination. Current research is attempting to synthesize superconducting MgB 2 coatings on spherical Si beads with the findings of this study. Future efforts are focused on the construction and testing of a levitation apparatus.

36 MATERIALS SCIENCE↗

CHARACTERIZING SURFACE LAYERS IN NITINOL USING X-RAY PHOTOELECTRON SPECTROSCOPY

Nitinol is a shape memory alloy whose properties allow for large reversible deformations and a return to its original geometry. This nickel-titanium (NiTi) alloy has become a material used widely in the biomedical fi eld as a stent to open up collapsed arteries. Both ambient and biological conditions cause surface oxidation in these devices which in turn change its biocompatibility. The thickness of oxidized layers can cause fractures in the material if too large and can allow for penetration if too thin. Depending on the type and abundance of the chemical species on or near the surface, highly toxic metal ions can leak into the body causing cell damage or even cell death. Thus, biocompatibility of such devices is crucial. By using highly surface sensitive x-ray photoelectron spectroscopy to probe the surface of these structures, it is possible to decipher both layer composition and layer thickness. Two samples, both of which were mechanically polished, were investigated. Of the two samples, one was then exposed to a phosphate buffered saline (PBS) solution to mimic the chemical properties of blood, while the other remained unexposed. Although both samples were found to have oxide layers of appropriate thickness (on the order of a few nm), it was found that the sample exposed to the saline solution had a slightly thicker oxide layer and more signifi cantly, a phosphate layer very near the surface suggesting toxic metal components are well contained within the sample. These are considerable indications of a biocompatible device.

Christopfel, R↗

Bile salt hydrolase probe and method of making and using the same

Probe embodiments for targeting, identifying, and isolating enzymes exhibiting BSH activity as well as devices and kits that use the probes are described herein. Methods of making and using the probes, devices, and kits are also described. In some embodiments, probes, devices, and kits for targeting, identifying, and isolating enzymes in a biological sample are disclosed. In some embodiments, compositions and methods of treatment using the probes, devices, and kits disclosed herein are described.

Wright, Aaron T.↗

ENHANCEMENT OF ENVIRONMENTAL SAMPLING THROUGH AN IMPROVED AIR MONITORING TECHNIQUE

Environmental sampling (ES) is a key component of International Atomic Energy Agency (IAEA) safeguarding approaches throughout the world. Performance of ES (e.g. air, water, vegetation, sediments, soil and biota) supports the IAEAs mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a State and has been available since the introduction of safeguards strengthening measures approved by the IAEA Board of Governors (1992-1997). A recent step-change improvement in the gathering and analysis of air samples at uranium/plutonium bulk handling facilities is an important addition to the international nuclear safeguards inspector's toolkit. Utilizing commonly used equipment throughout the IAEA network of analytical laboratories for particle analysis, researchers are developing the next generation of ES equipment for air grab and constant samples. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) silicon substrate has been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. The new collection equipment will allow IAEA nuclear safeguards inspectors to develop enhanced safeguarding approaches for complicated facilities. This paper will explore the use of air monitoring to establish a baseline environmental signature of a particular facility that could be used for comparison of consistencies in declared operations. The implementation of air monitoring will be contrasted against the use of smear ES when used during unannounced inspections, design information verification, limited frequency unannounced access, and complementary access visits at bulk handling facilities. Technical aspects of the air monitoring device and the analysis of its environmental samples will demonstrate the essential parameters required for successful application of the system.

54 ENVIRONMENTAL SCIENCES↗

Design and Modelling of a Microfluidic Electro-Lysis Device with Controlling Plates

Many Lab-on-Chip applications require sample pre-treatment systems. Using electric fields to perform cell-lysis in bio-MEMS systems has provided a powerful tool which can be integrated into Lab-on-a-Chip platforms. The major design considerations for electro-lysis devices include optimal geometry and placement of micro-electrodes, cell concentration, flow rates, optimal electric field (e.g. pulsed DC vs. AC), etc. To avoid electrolysis of the flowing solution at the exposed electrode surfaces, magnitudes and the applied voltages and duration of the DC pulse, or the AC frequency of the AC, have to be optimized for a given configuration. Using simulation tools for calculation of electric fields has proved very useful, for exploring alternative configurations and operating conditions for achieving electro cell-lysis. To alleviate the problem associated with low electric fields within the microfluidics channel and the high voltage demand on the contact electrode strips, two "control plates" are added to the microfluidics configuration. The principle of placing the two controlling plate-electrodes is based on the electric fields generated by a combined insulator/dielectric (gladwater) media. Surface charges are established at the insulator/dielectric interface. This paper discusses the effects of this interface charge on the modification of the electric field of the flowing liquid/cell solution.

Jenkins, A.↗

Laser ablation spectrometry system

This disclosure provides systems, methods, and apparatus related to laser ablation spectrometry systems. In one aspect, a system comprises a microscope, a laser, a continuous flow probe, and a gas confinement device. The laser is positioned to emit light through an objective lens of the microscope. The continuous flow probe is coupled to a spectrometer. An end of the continuous flow probe is positioned proximate a sample and between the sample and the objective lens. The gas confinement device defines a gas inlet, a chamber, a platform, a wall surrounding the platform, a plurality of vents, and a plurality of channels. Each of the plurality of vents is positioned to direct a gas substantially parallel to the platform, and each of the plurality of vents is defined in the wall. The plurality of channels is operable to provide fluid communication between the chamber and the plurality of vents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scanning SQUID characterization of extremely overdoped La 2-x Sr x CuO 4

Recently, advances in film synthesis methods have enabled a study of extremely overdoped La 2 - x Sr x Cu O 4 . This has revealed a surprising behavior of the superfluid density as a function of doping and temperature, the explanation of which is vividly debated. One popular class of models posits electronic phase separation, where the superconducting phase fraction decreases with doping, while some competing phase (e.g., ferromagnetic) progressively takes over. A problem with this scenario is that all the way up to the dome edge the superconducting transition remains sharp, according to mutual inductance measurements. However, the physically relevant scale is the Pearl penetration depth Λ P , and this technique probes the sample on a length scale L that is much larger than Λ P . In the present paper, we use local scanning superconducting quantum interference device (SQUID) measurements that probe the susceptibility of the sample on the scale L << Λ P . Our SQUID maps show uniform landscapes of susceptibility and excellent overall agreement of the local penetration depth data with the bulk measurements. Overall, these results contribute an important piece to the puzzle of how high-temperature superconductivity vanishes on the overdoped side of the cuprate phase diagram.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fundamental Mechanisms Driving the Amorphous to Crystalline Phase Transformation

Phase transformations are ubiquitous, fundamental phenomena that lie at the heart of many structural, optical and electronic properties in condensed matter physics and materials science. Many transformations, especially those occurring under extreme conditions such as rapid changes in the thermodynamic state, are controlled by poorly understood processes involving the nucleation and quenching of metastable phases. Typically these processes occur on time and length scales invisible to most experimental techniques ({micro}s and faster, nm and smaller), so our understanding of the dynamics tends to be very limited and indirect, often relying on simulations combined with experimental study of the ''time infinity'' end state. Experimental techniques that can directly probe phase transformations on their proper time and length scales are therefore key to providing fundamental insights into the whole area of transformation physics and materials science. LLNL possesses a unique dynamic transmission electron microscope (DTEM) capable of taking images and diffraction patterns of laser-driven material processes with resolution measured in nanometers and nanoseconds. The DTEM has previously used time-resolved diffraction patterns to quantitatively study phase transformations that are orders of magnitude too fast for conventional in situ TEM. More recently the microscope has demonstrated the ability to directly image a reaction front moving at {approx}13 nm/ns and the nucleation of a new phase behind that front. Certain compound semiconductor phase change materials, such as Ge{sub 2}Sb{sub 2}Te{sub 5} (GST), Sb{sub 2}Te and GeSb, exhibit a technologically important series of transformations on scales that fall neatly into the performance specifications of the DTEM. If a small portion of such material is heated above its melting point and then rapidly cooled, it quenches into an amorphous state. Heating again with a less intense pulse leads to recrystallization into a vacancy-stabilized metastable rock salt structure. Each transformation takes {approx}10-100 ns, and the cycle can be driven repeatedly a very large number of times with a nanosecond laser such as the DTEM's sample drive laser. These materials are widely used in optical storage devices such as rewritable CDs and DVDs, and they are also applied in a novel solid state memory technology - phase change memory (PCM). PCM has the potential to produce nonvolatile memory systems with high speed, extreme density, and very low power requirements. For PCM applications several materials properties are of great importance: the resistivities of both phases, the crystallization temperature, the melting point, the crystallization speed, reversibility (number of phase-transformation cycles without degradation) and stability against crystallization at elevated temperature. For a viable technology, all these properties need to have good scaling behavior, as dimensions of the memory cells will shrink with every generation. In this LDRD project, we used the unique single-shot nanosecond in situ experimentation capabilities of the DTEM to watch these transformations in GST on the time and length scales most relevant for device applications. Interpretation of the results was performed in conjunction with atomistic and finite-element computations. Samples were provided by collaborators at IBM and Stanford University. We observed, and measured the kinetics of, the amorphous-crystalline and melting-solidification transitions in uniform thin-film samples. Above a certain threshold, the crystal nucleation rate was found to be enormously high (with many nuclei appearing per cubic {micro}m even after nanosecond-scale incubation times), in agreement with atomistic simulation and consistent with an extremely low nucleation barrier. We developed data reduction techniques based on principal component analysis (PCA), revealing the complex, multi-dimensional evolution of the material while suppressing noise and irrelevant information. Using a novel specimen geometry, we also achieved repeated switching between the amorphous and crystalline phases enabling in situ study of structural change after phase cycling, which is relevant to device performance. We also observed the coupling between the phase transformations and the evolution of morphology on the nanometer scale, revealing the gradual development of striations in uniform films and preferential melting at sharp edges in laser-heated nanopatterned GST. This nonuniform melting, interpreted through simulation as being a direct result of geometrical laser absorption effects, appears to be responsible for a marked loss in morphological stability even at moderate laser intensities and may be an important factor in the longevity of nanostructured phase change materials in memory applications.

36 MATERIALS SCIENCE↗

Estimation of proportions of objects and determination of training sample-size in a remote sensing application

A multichannel scanning device may fail to observe objects because of obstructions blocking the view, or different categories of objects may make up a resolution element giving rise to a single observation. Ground truth will be required on any such categories of objects in order to estimate their expected proportions associated with various classes represented in the remote sensing data. Considering the classes to be distributed as multivariate normal with different mean vectors and common covariance, maximum likelihood estimates are given for the expected proportions of objects associated with different classes, using the Bayes procedure for classification of individuals obtained from these classes. An approximate solution for simultaneous confidence intervals on these proportions is given, and thereby a sample-size needed to achieve a desired amount of accuracy for the estimates is determined.

Chhikara, R. S.↗

Shock compression of liquid helium and helium-hydrogen mixtures : development of a cryogenic capability for shock compression of liquid helium on Z, final report for LDRD Project 141536.

This final report on SNL/NM LDRD Project 141536 summarizes progress made toward the development of a cryogenic capability to generate liquid helium (LHe) samples for high accuracy equation-of-state (EOS) measurements on the Z current drive. Accurate data on He properties at Mbar pressures are critical to understanding giant planetary interiors and for validating first principles density functional simulations, but it is difficult to condense LHe samples at very low temperatures (<3.5 K) for experimental studies on gas guns, magnetic and explosive compression devices, and lasers. We have developed a conceptual design for a cryogenic LHe sample system to generate quiescent superfluid LHe samples at 1.5-1.8 K. This cryogenic system adapts the basic elements of a continuously operating, self-regulating {sup 4}He evaporation refrigerator to the constraints of shock compression experiments on Z. To minimize heat load, the sample holder is surrounded by a double layer of thermal radiation shields cooled with LHe to 5 K. Delivery of LHe to the pumped-He evaporator bath is controlled by a flow impedance. The LHe sample holder assembly features modular components and simplified fabrication techniques to reduce cost and complexity to levels required of an expendable device. Prototypes have been fabricated, assembled, and instrumented for initial testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temperature Dependent Spin Dynamics in La 0.67 Sr 0.33 MnO 3 /Pt Bilayers

Complex ferromagnetic oxides such as La 0.67 Sr 0.33 MnO 3 (LSMO) offer pathways for creating energy‐efficient spintronic devices with new functionalities. LSMO exhibits high‐temperature ferromagnetism, half metallicity, sharp resonance linewidth, low damping, and a large anisotropic magnetoresistance response. Combined with Pt, a proven material with high spin‐charge conversion efficiency, LSMO can be used to create robust nano‐oscillators for neuromorphic computing. Ferromagnetic resonance (FMR) and device‐level spin‐pumping FMR measurements are performed to investigate the magnetization dynamics and spin transport in NdGaO 3 (110)/LSMO(15 nm)/Pt(0 and 5 nm) thin films ranging from 300 K to 90 K and compare the device performance with Py(7 nm)/Pt(5 nm) sample. The spin current pumped into Pt is quantified to determine the temperature‐dependent influence of interfacial interactions. The generated spin current in the micro‐device is maximum at 170 K for the optimally grown LSMO/Pt films. Additionally, this bilayer system exhibits low magnetic Gilbert damping (0.002), small linewidth (12 Oe), and a large spin Hall angle (≈3.2%) at 170 K. Ex situ deposited LSMO/Pt bilayers demonstrate excellent dynamic response, exhibiting fourfold enhancement in signal output, eightfold reduction in damping, and a threefold reduction in linewidth as compared to the Pt/Py system. Such robust device‐level performance can pave way for energy‐efficient spintronic‐based devices.

complex perovskite thin films↗

Democratization of fungal highway columns as a tool to investigate bacteria associated with soil fungi

ABSTRACT Bacteria–fungi interactions (BFIs) are essential in ecosystem functioning. These interactions are modulated not only by local nutritional conditions but also by the physicochemical constraints and 3D structure of the environmental niche. In soils, the unsaturated and complex nature of the substrate restricts the dispersal and activity of bacteria. Under unsaturated conditions, some bacteria engage with filamentous fungi in an interaction (fungal highways) in which they use fungal hyphae to disperse. Based on a previous experimental device to enrich pairs of organisms engaging in this interaction in soils, we present here the design and validation of a modified version of this sampling system constructed using additive printing. The 3D printed devices were tested using a novel application in which a target fungus, the common coprophilous fungus Coprinopsis cinerea, was used as bait to recruit and identify bacterial partners using its mycelium for dispersal. Bacteria of the genera Pseudomonas, Sphingobacterium and Stenotrophomonas were highly enriched in association with C. cinerea. Developing and producing these new easy-to-use tools to investigate how bacteria overcome dispersal limitations in cooperation with fungi is important to unravel the mechanisms by which BFIs affect processes at an ecosystem scale in soils and other unsaturated environments.

54 ENVIRONMENTAL SCIENCES↗

An investigation of the SNS Josephson junction as a three-terminal device

A particular phenomenon of the SNS Josephson junction was investigated; i.e., control by a current entering the normal region and leaving through one of the superconducting regions. The effect of the control current on the junction was found to be dependent upon the ration of the resistances of the two halves of the N layer. A low frequency, lumped, nonlinear model was proposed to describe the electrical characteristics of the device, and a method was developed to plot the dynamic junction resistance as a function of junction current. The effective thermal noise temperature of the sample was determined. Small signal linearized analysis of the device suggests its use as an impedance transformer, although geometric limitations must be overcome. Linear approximation indicates that it is reciprocal and no power gain is possible. It is felt that, with suitable metallurgical and geometrical improvements, the device has promise to become a superconducting transistor.

Meissner, H.↗

Cone beam x-ray luminescence computed tomography: A feasibility study

Purpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper. Methods: In the cone beam XLCT system, the cone beam x ray was adopted to illuminate the sample and a highly sensitive CCD camera was utilized to acquire luminescent photons emitted from the sample. Photons scattering in biological tissues makes it an ill-posed problem to reconstruct the 3D distribution of the x-ray luminescent sample in the cone beam XLCT. In order to overcome this issue, the authors used the diffusion approximation model to describe the photon propagation in tissues, and employed the sparse regularization method for reconstruction. An incomplete variables truncated conjugate gradient method and permissible region strategy were used for reconstruction. Meanwhile, traditional x-ray CT imaging could also be performed in this system. The x-ray attenuation effect has been considered in their imaging model, which is helpful in improving the reconstruction accuracy. Results: First, simulation experiments with cylinder phantoms were carried out to illustrate the validity of the proposed compensated method. The experimental results showed that the location error of the compensated algorithm was smaller than that of the uncompensated method. The permissible region strategy was applied and reduced the reconstruction error to less than 2 mm. The robustness and stability were then evaluated from different view numbers, different regularization parameters, different measurement noise levels, and optical parameters mismatch. The reconstruction results showed that the settings had a small effect on the reconstruction. The nonhomogeneous phantom simulation was also carried out to simulate a more complex experimental situation and evaluated their proposed method. Second, the physical cylinder phantom experiments further showed similar results in their prototype XLCT system. With the discussion of the above experiments, it was shown that the proposed method is feasible to the general case and actual experiments. Conclusions: Utilizing numerical simulation and physical experiments, the authors demonstrated the validity of the new cone beam XLCT method. Furthermore, compared with the previous narrow beam XLCT, the cone beam XLCT could more fully utilize the x-ray dose and the scanning time would be shortened greatly. The study of both simulation experiments and physical phantom experiments indicated that the proposed method was feasible to the general case and actual experiments.

60 APPLIED LIFE SCIENCES↗

Portable, wind sensitive, directional air sampler

Air Scout unit has preset timer that controls length of time filter slides are in sampling position. At end of sampling period, fresh slide is automatically moved into position, and exposed filter is displaced into storage compartment. Device may be set up, loaded, programmed, and left to acquire samples automatically.

Deyo, J. N.↗