Results of tests of the SRB aft skirt heat shield curtain in the MSFC Hot Gas Facility
During the first two space shuttle flights the aft skirt heat shield curtain performed well during ascent but failed during reentry. This exposed the inside of the skirt and its subsystems to reentry heating. The resulting exposure damaged various expensive systems items and therefore a curtain reassessment is required. As a part of this reassessment, tests were conducted in the MSFC Hot Gas Facility (HGF). The purposes of these tests were to determine if the curtain would fail in a manner similar to that in flight and to demonstrate that meaningful tests of the curtain can be conducted in the HGF.