Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

ATS-6 - The Geosynchronous Very High Resolution Radiometer

The Geosynchronous Very High Resolution Radiometer (GVHRR), flown on the three-axis stabilized geosynchronous satellite, Applications Technology Satellite-6 (ATS-6), collected meteorological data for two months during the summer of 1974. Several hundred images were successfully taken. Data collection terminated when the instrument chopper motor failed. The instrument, its supporting ground equipment, and the data collected in orbit are described.

Shenk, W. E.↗

Meteorological interpretations of the images from the Nimbus 5 electrically scanned microwave radiometer

The Nimbus 5 Electrically Scanned Microwave Radiometer (ESMR) is useful in determining the extent, structure, and intensity of rainfall over oceans. It is possible on the basis of rainfall maps to determine the location of frontal rain, rain/snow boundaries, and the structure of tropical storms. ESMR data on rainfall over the east coast of the United States and the Gulf of Mexico, on snowfall over the northeast coast of the United States, on frontal zones in the northwestern Pacific and on the tropical storm Leila in the South Indian Ocean are examined. Because of the generally high emissivities of land surfaces, interpretation of meteorological parameters over land is not yet possible.

Wilheit, T. T.↗

Remote sensing of soil moisture by Skylab radiometer and scatterometer sensors

A Skylab experiment was designed to evaluate the feasibility of monitoring the moisture content of the soil from space. Data from various Skylab sensors were collected across two test sites while direct measurements of soil moisture were being made at the surface depths of soil. Correlations were obtained between the moisture content of the soil and radiometer sensors (S193 and S194) and the scatterometer instrument (S193). The high correlations obtained indicate that microwave sensors may be quite useful for such measurements in the future.-

Eagleman, J. R.↗

Evaluation of the dual differential radiometer for remote sensing of sediment and chlorophyll in turbid waters

The dual differential radiometer (DDR) was tested to determine its capability for measuring suspended sediment and chlorophyll in turbid waters. Measurements were obtained from a boat dock and from a helicopter with combinations of sample and reference filters with peak transmissions at various wavelengths. Water samples were taken concurrently and were analyzed for light scattering, particle count, and total chlorophyll. Least-squares estimates of the linear relationship between DDR output and the water parameters yielded correlation coefficients of less than 0.7. Under the turbid water conditions of the present tests, the DDR did not accurately measure either suspended sediment or chlorophyll. A precise knowledge of the spectral signatures of various pollutants might enable appropriate filters to be selected for tuning the DDR to monitor a particular pollutant.

Witte, W. G.↗

Remote sensing of soil moisture by a 21-cm passive radiometer

Microwave sensors on Skylab collected data as part of the Earth Resources Experiment Package. An investigation was designed to obtain field observations of soil moisture content for comparison with data from Skylab. The 21-cm radiometer has been shown to be highly responsive to the moisture content of the upper 2.5-cm layer of soil. A composite relationship between the radiometric temperature and soil moisture content has been determined from five data sets obtained over Kansas and Texas. This relationship, having a correlation index of -0.96, has been used as a basis for calculating the soil moisture content of large areas across the United States.

Eagleman, J. R.↗

Radiometer gives true absorption and emission coefficients

Novel radiometer, unaffected by scattering and polarization, measures true absorption and emmission coefficients for arbitrary mixture of gases and polluting particles. It has potential astronomical, meteorological, and environmental applications, such as determination of radiative heat budget, aerosol relative concentration, and morphology of cloud, haze, and fog formations. Data and temperature can be coupled directly to small computer for online calculation of radiation coefficients.

Fymat, A. L.↗

Investigation of a Real-time Processing System for the NASA Multifrequency Microwave Radiometer

A study was conducted to investigate the data reduction and processing requirements for the multifrequency microwave radiometer system (MFMR). The objectives were to develop and evaluate algorithms and processing techniques which might provide for dedicated real time or near real time data processing and to develop a configuration design and processor recommendation to accomplish the data reduction. An analysis of the required data reduction and calibration equations was included along with the identification of sources of error which may be present in the (MFMR) data. The definition and evaluation of the significance of effects introduced by aircraft perturbation was given.

Source record↗

Study of a Vuilleumier cycle cryogenic refrigerator for detector cooling on the limb scanning infrared radiometer

A program to detect and monitor the presence of trace constituents in the earth's atmosphere by using the Limb Scanning Infrared Radiometer (LSIR) is reported. The LSIR, which makes radiometric measurements of the earth's limb radiance profile from a space platform, contains a detector assembly that must be cooled to a temperature of 65 + or - 2 K. The feasibility of cooling the NASA-type detector package with Vuilleumier (VM) cryogenic refrigerator was investigated to develop a preliminary conceptual design of a VM refrigerator that is compatible with a flight-type LSIR instrument. The scope of the LSIR program consists of analytical and design work to establish the size, weight, power consumption, interface requirements, and other important characteristics of a cryogenic cooler that would meet the requirements of the LSIR. The cryogenic cooling requirements under the conditions that NASA specified were defined. Following this, a parametric performance analysis was performed to define the interrelationships between refrigeration characteristics and mission requirements. This effort led to the selection of an optimum refrigerator design for the LSIR mission.

Russo, S. C.↗

Scanning radiometer for measurement of forward-scattered light to determine mean diameter of spray particles

A scanning radiometer is reported that measures forward-scattered light to determine the mean diameter of spray particles. An optical scanning method gives a continuous measurement of the light-scattering angle during spray nozzle tests. A method of calibration and a correction for background light are presented. Mean particle diameters of 10 to 500 micrometers can be measured.

Buchele, D. R.↗

Scanning mechanism study for multi-frequency microwave radiometers

Scanning mode for a microwave radiometer having large aperture antenna is determined from scientific needs by engineering tradeoffs. Two configurations of the scan drive mechanism with an integral momentum compensation are formulated for 1.OM and 1.4M diameter antennas. As the formulation is based on currently available components, it is possible to design and fabricate the formulated mechanism without new hardware development. A preliminary specification for major components of formulated drives is also included in the report.

Shin, I.↗

A K-band radiometer for the microwave weather project

The design of a K-band radiometer for use in the microwave weather project is discussed. The major components of the system, such as feedhorn, waveguide switch, and receiver assembly are described. The system will be installed at DSS 13 at Goldstone, California, when completed.

Wallace, K.↗

A five-frequency radiometer antenna system feed horn

The feasibility of operating a five frequency feed as a radiometer for use on board a Nimbus type satellite was investigated. Five narrow band frequencies (6.6, 10.7, 18.5, 21.5 and 33 GHz) were multiplexed onto a single receive feed employing dual linear polarization at each frequency with a better than 25 db isolation between each polarization. The production of a horn design which can illuminate a parabolic reflector segment with an f/D ratio of approximately 0.4, producing an edge illumination of approximately -20 db is described. The final overall design is presented with results showing that this design concept has an acceptable electrical performance.

Source record↗

Advanced Atmospheric Sounder and Imaging Radiometer (AASIR)

Design information for the Advanced Atmospheric Sounder and Imaging Radiometer is reported, which was developed to determine the configuration of a sensor for IR and visible imaging. The areas of technology reported include: systems design, optics, mechanics, electronics, detectors, radiative cooler, and radiometric calibration.

Source record↗

Heat capacity mapping radiometer for AEM spacecraft

The operation, maintenance, and integration of the applications explorer mission heat capacity mapping radiometer is illustrated in block diagrams and detail schematics of circuit functions. Data format and logic timing diagrams are included along with radiometric and electronic calibration data. Mechanical and electrical configuration is presented to provide interface details for integration of the HCMR instrument to AEM spacecraft.

Sonnek, G. E.↗

Three field tests of a gas filter correlation radiometer

Test flights to remotely measure nonurban carbon monoxide (CO) concentrations by gas filter correlation radiometry are discussed. The inferred CO concentrations obtained through use of the Gas Filter Correlation Radiometer (GFCR) agreed with independent measurements obtained by gas chromatography air sample bottle analysis to within 20 percent. The equipment flown on board the aircraft, the flight test procedure, the gas chromatograph direct air sampling procedure, and the GFCR data analysis procedure are reported.

Campbell, S. A.↗

Insolation measurements with a portable CuS-CdS radiometer

Solar radiation measurements were carried out with a portable Cu2S-Cds radiometer. The measurements were found to be accurate to better than 5% (better than 3% when sophisticated metering is employed). Calibration to an Eppley precision pyranometer is discussed.

Windawi, H. M.↗

DSN water vapor radiometer development: Recent work

A water vapor radiometer (WVR) was developed which measures the atmospheric noise temperature at two different frequencies. These noise temperatures are used in empirical-theoretical equations which yield tropospheric range delay, in centimeters, through the atmosphere along the beam of the WVR. This range correction is then applied to measurements concerning spacecraft range and to very long baseline interferometry determinations.

Slobin, S. D.↗

Advanced atmospheric sounder and imaging radiometer /AASIR/ for STORMSAT

The principal mission of the three-axis stabilized STORMSAT spacecraft is to provide the necessary meteorological data for tracking, studying the detailed structure, and modeling mesoscale weather phenomena. In the area of mesoscale events, the following meteorological objectives are indicated: high-quality imagery, visible and infrared; wind velocity from cloud tracers (1 m/sec), atmospheric temperature profiles (1 K), and atmospheric humidity sounding. These objectives are reflected in the functional characteristics of the AASIR, which is a second generation meteorological sensor based on the Visible Infrared Spin-Scan Radiometer (VISSR) and the Atmospheric Sounder (VAS). The AASIR design and interface constraints with the STORMSAT spacecraft is discussed.

Chase, S. C.↗