Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Kinetic equilibria of relativistic collisionless plasmas in the presence of non-stationary electromagnetic fields

The kinetic description of relativistic plasmas in the presence of time-varying and spatially non-uniform electromagnetic (EM) fields is a fundamental theoretical issue both in astrophysics and plasma physics. This refers, in particular, to the treatment of collisionless and strongly-magnetized plasmas in the presence of intense radiation sources. In this paper, the problem is investigated in the framework of a covariant gyrokinetic treatment for Vlasov–Maxwell equilibria. The existence of a new class of kinetic equilibria is pointed out, which occur for spatially-symmetric systems. These equilibria are shown to exist in the presence of non-uniform background EM fields and curved space-time. In the non-relativistic limit, this feature permits the determination of kinetic equilibria even for plasmas in which particle energy is not conserved due to the occurrence of explicitly time-dependent EM fields. Finally, absolute stability criteria are established which apply in the case of infinitesimal symmetric perturbations that can be either externally or internally produced.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility and safety of outpatient brachytherapy in 37 patients with brain tumors using the GliaSite Radiation Therapy System

Temporary, low dose rate brachytherapy to the margins of resected brain tumors, using a balloon catheter system (GliaSite Radiation Therapy System) and liquid I-125 radiation source (Iotrex), began in 2002 at the University of Arizona Medical Center. Initially, all patients were treated on an inpatient basis. For patient convenience, we converted to outpatient therapy. In this article we review the exposure data and safety history for the 37 patients treated as outpatients. Proper patient selection and instruction is crucial to having a successful outpatient brachytherapy program. A set of evaluation criteria and patient instructions were developed in compliance with the U.S. Nuclear Regulatory Commission's document NUREG-1556 Volume 9 (Appendix U) and Arizona State Nuclear regulatory guidelines, which specify acceptable exposure rates for outpatient release in this setting. Of the 37 patients monitored, 26 patients were treated for recurrent glioblastoma multiforme (GBM), six for primary GBM, and five for metastatic brain tumors. All 37 patients and their primary caregivers gave signed agreement to follow a specific set of instructions and were released for the duration of brachytherapy (3-7 days). The typical prescription dose was 60 Gy delivered at 0.5 cm from the balloon surface. Afterloaded activities in these patients ranged from 90.9 to 750.0 mCi and measured exposure rates at 1 m from the head were less than 14 mR/h. The mean exposure to the caretaker measured by personal radiation Landauer Luxel+ whole body dosimeters for 25 caretakers was found to be 9.6 mR, which was significantly less than the mean calculated exposure of 136.8 mR. For properly selected patients, outpatient brachytherapy is simple and can be performed within established regulatory guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Small-angle X-ray scattering, synchrotron radiation, and the structure of bio- and nanosystems

Small-angle X-ray scattering is a universal diffraction method for studying the supra-atomic structure of matter. The potential of this technique has greatly increased in recent years due to the development of bright synchrotron radiation sources. The extensive use of these sources, in combination with new techniques for analyzing scattering data and structure modeling, made small-angle scattering one of the most effective analytical methods for studying nanoscale structures. In this review, after a brief outline of the basic principles of small-angle scattering by isotropic dispersed nanosystems, we consider two areas of nanodiagnostics, in which the progress in the small-angle experiment and the latest techniques for interpreting scattering data has become pronounced in recent years. These areas-the analysis of the structure of biological macromolecules in a solution and structural studies of metal nanoparticles synthesized in polymer and aqueous media-are illustrated by examples of practical biological and nanotechnologycal applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parametric amplification of broadband radiation of a cw superluminescent diode under picosecond pumping

It is proposed to use cw superluminescent diodes with a spectral width of about 300 cm{sup −1} and high spatial coherence as seed radiation sources in parametric amplifiers with picosecond pumping in order to form broadband picosecond pulses. A two-cascade parametric amplifier based on BaB{sub 2}O{sub 4} (BBO) crystals is pumped by 20-ps pulses of the second harmonic of an Nd : YAG laser. For a superluminescent diode spectral width of 275 cm{sup −1} (centre wavelength 790 nm), the spectral width of picosecond pulses at the parametric amplifier output is 203 cm{sup −1}. At a total pump energy of 7.2 mJ for BBO crystals, the energy of the enhanced emission of the superluminescent diode is found to be 0.6 mJ.

42 ENGINEERING↗

High Power UV LED Industrial Curing Systems

UV curing is a green technology that is largely underutilized because UV radiation sources like Hg Lamps are unreliable and difficult to use. High Power UV LEDs are now efficient enough to replace Hg Lamps, and offer significantly improved performance relative to Hg Lamps. In this study, a modular, scalable high power UV LED curing system was designed and tested, performing well in industrial coating evaluations. In order to achieve mechanical form factors similar to commercial Hg Lamp systems, a new patent pending design was employed enabling high irradiance at long working distances. While high power UV LEDs are currently only available at longer UVA wavelengths, rapid progress on UVC LEDs and the development of new formulations designed specifically for use with UV LED sources will converge to drive more rapid adoption of UV curing technology. An assessment of the environmental impact of replacing Hg Lamp systems with UV LED systems was performed. Since UV curing is used in only a small portion of the industrial printing, painting and coating markets, the ease of use of UV LED systems should increase the use of UV curing technology. Even a small penetration of the significant number of industrial applications still using oven curing and drying will lead to significant reductions in energy consumption and reductions in the emission of green house gases and solvent emissions.

42 ENGINEERING↗

A research of W-band folded waveguide traveling wave tube with elliptical sheet electron beam

Folded waveguide (FWG) traveling wave tube (TWT), which shows advantages in high power capacity, moderate bandwidth, and low-cost fabrication, has become the focus of vacuum electronics recently. Sheet electron beam devices are better suited for producing radiation sources with large power in millimeter wave spectrum due to their characteristics of relatively low space charge fields and large transport current. A FWG TWT with elliptical sheet beam working in W-band is presented in this paper, with the analysis of its dispersion characteristics, coupling impedance, transmission properties, and interaction characteristics. A comparison is also made with the traditional FWG TWT. Simulation results lead to the conclusion that the FWG TWT with elliptical sheet beam investigated in this paper can make full use of relatively large electric fields and thus generate large output power with the same electric current density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ X-ray photoelectron spectroscopy studies of water on metals and oxides at ambient conditions

X-ray photoelectron spectroscopy (XPS) is a powerful tool for surface and interface analysis, providing the elemental composition of surfaces and the local chemical environment of adsorbed species. Conventional XPS experiments have been limited to ultrahigh vacuum (UHV) conditions due to a short mean free path of electrons in a gas phase. The recent advances in instrumentation coupled with third-generation synchrotron radiation sources enables in-situ XPS measurements at pressures above 5 Torr. In this review, we describe the basic design of the ambient pressure XPS setup that combines differential pumping with an electrostatic focusing. We present examples of the application of in-situ XPS to studies of water adsorption on the surface of metals and oxides including Cu(110), Cu(111), TiO2(110) under environmental conditions of water vapor pressure. On all these surfaces we observe a general trend where hydroxyl groups form first, followed by molecular water adsorption. The importance of surface OH groups and their hydrogen bonding to water molecules in water adsorption on surfaces is discussed in detail.

36 MATERIALS SCIENCE↗

The cyclotron resonance in Heterostructures with the InSb/AlInSb quantum wells

The absorption of two-dimensional electrons in InSb-based quantum wells in the quantized magnetic fields in the terahertz spectral region are studied. A p-Ge-based cyclotron laser was used as the radiation source. The effective mass of carriers at the Fermi level equal to 0.0219m{sub 0} (m{sub 0} is the mass of a free electron) is determined from the cyclotron resonance spectra. It is shown that the electron spectrum is described by the Kane model in a wide range of magnetic fields. An anomalously pronounced splitting of the cyclotron resonance line not associated with the nonparabolicity of the conduction band of InAs is observed in low magnetic fields, which can be attributed to the effect of the spin-orbit interaction.

36 MATERIALS SCIENCE↗

A study of radiolytic stability of 25,27-bis(2-propyloxy) calix[4]-26,28-crown-6 (iPR-C[4]C-6)

The radiolytic stability of 25,27-bis(2-propyloxy)calix[4] arene -26,28-crown-6 (iPr-C[4]C-6) was studied. {sup 60}co was used as a radiation source. Its dose rate was 437 Gy/min., and the total absorbed dose of the iPr-C[4]C-6 was from 10{sup 4} to 10{sup 6} Gy. The iPr-C[4]C-6 solid and 0.025 mol/L iPr-C[4]C-6/n-octanol which were pre-equilibrated with 0.01 mol/L and 3 mol/L nitric acid, respectively, were given different doses, and their extraction performance was researched. Their degradation mechanism was investigated by mass spectrometry (MS) and infrared spectroscopy (IR). The results show that radiolytic stability of the iPr-C[4]C-6 solid and 0.025 mol/L iPr-C[4]C-6/n-octanol are good when their absorbed dose is less than 10{sup 6} Gy. The extracting system of iPr-C[4]C-6/n-octanol is promising for separating cesium from high-level liquid waste(HLLW)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A legacy of the ""megagoule committee,"" thirty years of explosive pulsed power research and development at Los Alamos National Laboratory

In 1980, Los Alamos formed the 'Megajoule Committee' with the expressed goal of developing a one Megajoule plasma radiation source. The ensuing research and development has given rise to a wide variety of high explosive pulsed power accomplishments, and there is a continuous stream of work that continues to the present. A variety of flux compression generators (FCGs or generators) have been designed and tested, and a number of pulse shortening schemes have been investigated. Supporting computational tools have been developed in parallel with experiments. No fewer that six unique systems have been developed and used for experiments. This paper attempts to pull together the technical details, achievements, and wisdom amassed during the intervening thirty years, and notes how we would push for increased performance in the future.

47 OTHER INSTRUMENTATION↗

Equation of state of bcc-Mo by static volume compression to 410 GPa

Unit cell volumes of Mo and Pt have been measured simultaneously to ≈400 GPa by x-ray powder diffraction using a diamond anvil cell and synchrotron radiation source. The body-centered cubic (bcc) phase of Mo was found to be stable up to 410 GPa. The equation of state (EOS) of bcc-Mo was determined on the basis of Pt pressure scale. A fit of Vinet EOS to the volume compression data gave K{sub 0} = 262.3(4.6) GPa, K{sub 0}′ = 4.55(16) with one atmosphere atomic volume V{sub 0} = 31.155(24) A{sup 3}. The EOS was in good agreement with the previous ultrasonic data within pressure difference of 2.5%–3.3% in the multimegabar range, though the EOS of Mo proposed from a shock compression experiment gave lower pressure by 7.2%–11.3% than the present EOS. The agreement would suggest that the Pt pressure scale provides an accurate pressure value in an ultra-high pressure range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A full-field transmission x-ray microscope for time-resolved imaging of magnetic nanostructures

Sub-nanosecond magnetization dynamics of small permalloy (Ni{sub 80}Fe{sub 20}) elements has been investigated with a new full-field transmission microscope at the soft X-ray beamline P04 of the high brilliance synchrotron radiation source PETRA III. The soft X-ray microscope generates a flat-top illumination field of 20 μm diameter using a grating condenser. A tilted nanostructured magnetic sample can be excited by a picosecond electric current pulse via a coplanar waveguide. The transmitted light of the sample plane is directly imaged by a micro zone plate with < 65 nm resolution onto a 2D gateable X-ray detector to select one particular bunch in the storage ring that probes the time evolution of the dynamic information successively via XMCD spectromicroscopy in a pump-probe scheme. In the experiments it was possible to generate a homogeneously magnetized state in patterned magnetic layers by a strong magnetic Oersted field pulse of 200 ps duration and directly observe the recovery to the initial flux-closure vortex patterns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of Criticality Analysis Capability of SuperMC with ICSBEP

SuperMC is a general purpose, intelligent and multifunctional, continuous energy Monte Carlo program for the design and safety evaluation of nuclear systems. It is designed to perform the comprehensive neutronics calculation, taking the radiation transport as the core and including the depletion, radiation source term/dose/biohazard, material activation and transmutation, etc. The latest version of SuperMC can perform the simulation of neutron, photon and coupled neutron and photon transport, and also equipped with the functions of automatic modeling and visualization. SuperMC has been verified by more than 2000 benchmark models and experiments including the handbook of International Criticality Safety Benchmark Evaluation Project (ICSBEP), the Shielding Integral Benchmark Archive Database (SINBAD), etc. The fusion reactor (ITER benchmark model, FDS Fusion Reactors), fast reactors (BN600, CLEAR-I), PWR reactors (HM, BEAVRS) and cases from the International Reactor Physics handbook Evaluation Program (IRPhEP) were employed for validating the comprehensive capability for reactor applications. In this paper, the validation of SuperMC based on the handbook of ICSBEP will be presented. ICSBEP, released by OECD/NEA, contains criticality safety benchmark specifications derived from experiments that were performed at various nuclear critical facilities around the world, which was widely used to verify neutronic codes and associated nuclear data libraries for criticality safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Smoke and particle detector using tritiated semiconductor foil

A smoke and particle ionization detector using tritiated amorphous silicon film as the radiation source is demonstrated. The ion chamber design includes both bipolar and unipolar region; the unipolar region is defined as the volume space extending beyond the range of ionizing particles. Attachment of ions to particulate matter in the unipolar region considerably reduces the mobility of the carriers, thus forming a space charge cloud accompanied by a reduction in the electrical field strength, thereby enhancing the particulate detection responsivity. Tritium {beta}s have a maximum range of about 6 mm in air, which makes the detector compact. Owing to the potential of increased specific activity, it results in a gamma-free detector with improved sensitivity. The results show that this gamma-free detector is several-fold to forty-fold more responsive than traditional ionization detectors using Am-241. In addition, this ion chamber can function as a dual detector having both photoelectric and ionization detector responsivities. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ENDF/B-VII Nuclear Data Libraries for SCALE-6.0

Version 6 of the SCALE (Standardized Computer Analyses for Licensing Evaluation) code system was released in February 2009. SCALE provides a comprehensive, integrated package of modular programs and nuclear data for a wide range of applications, including reactor physics, criticality safety, shielding, sensitivity/uncertainty analysis, and isotopic transmutation and radiation source term determination. SCALE computational modules are executed by automated control sequences that prepare input and call the desired modules in a particular order, linking output from one calculation to the next in series. The SCALE lattice physics sequence TRITON generates few-group, assembly-homogenized cross sections, as a function of burnup and branch states, which can be input to core simulator codes. TRITON couples the ORIGEN-S depletion module with either the NEWT (NEW Transport algorithm) twodimensional (2D) arbitrary-geometry transport code or the three-dimensional Monte Carlo KENO code. Fluxes from the transport solution, along with self-shielded multigroup (MG) cross sections, are passed to ORIGEN-S, which computes the time-dependent isotopic concentrations of more than 1400 nuclides. One of the major advancements in SCALE 6 is the availability of new nuclear data libraries based on ENDF/BVII for neutron transport calculations. In this paper we describe the SCALE ENDF/B-VII (designated here as V7) libraries and present some validation results for critical benchmarks and isotopic depletion experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discovery of difference in the diffuse scattering from nonstoichiometric Ca{sub 0.87}La{sub 0.13}F{sub 2.13} and Ca{sub 0.92}Er{sub 0.08}F{sub 2.08} crystals with different types of clusters of structural defects

A new approach to application of diffuse scattering (DS) for studying the defect structure of crystals on laboratory radiation sources is implemented. The basic principles of this approach are as follows: (i) choice of crystals with a high concentration of structural defects (highly nonstoichiometric Ca{sub 1-x}R{sub x}F{sub 2+x} phases), (ii) application of intermeasurement minimization method (experimental comparison) to select a weak desired DS signal from a superposition of signals of different nature, and (iii) choice of the basic model proceeding from the reliable information provided by accurate analysis of the contribution of structural defects to Bragg reflections. Significantly different DS diffraction patterns have been recorded for Ca{sub 0.87}La{sub 0.13}F{sub 2.13} and Ca{sub 0.92}Er{sub 0.08}F{sub 2.08} crystals, characterized by different types of structural-defect clusters, determined from the Bragg diffraction data. Experiments performed at 90-100 K proved that DS is caused by clusters with stable atomic configurations rather than cooperative thermal atomic vibrations. A set of methods is proposed which can efficiently be used in diagnostics of nanomaterials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Closed Orbit Measurement System at the DELTA Synchrotron Radiation Facility And First Investigations Concerning the Installation of a Beam Based BPM Calibration System

For a synchrotron radiation source it is necessary to operate a monitoring system to determine the beam position with high resolution and accuracy with respect to the axis of the quadrupole magnets. In this paper the present closed orbit measurement system of the DELTA SR-Facility, concerning the hardware setup, data processing and the calibration methods, will be presented. The results of the calibration measurements and the recent operating experience will be discussed. These results show, that the system is close to the design resolution. But the BPM offsets with respect to the magnetic center of the quadrupole magnets turn out to be not acceptable. For some BPMs they are in the order of several 100 micro m. Therefore it was decided to install a beam based BPM calibration system in the near future . This system should allow to determine the BPM offsets relative to the center of the quadrupole magnets for all 40 BPMs. It is planned to install a system in order to change the focussing strength of each quadrupole individually either in a static or dynamic way.

43 PARTICLE ACCELERATORS↗

ENDF/B-VII.0: Next Generation Evaluated Nuclear Data Library for Nuclear Science and Technology

Version 6 of the SCALE (Standardized Computer Analyses for Licensing Evaluation) code system was released in February 2009. SCALE provides a comprehensive, integrated package of modular programs and nuclear data for a wide range of applications, including reactor physics, criticality safety, shielding, sensitivity/uncertainty analysis, and isotopic transmutation and radiation source term determination. SCALE computational modules are executed by automated control sequences that prepare input and call the desired modules in a particular order, linking output from one calculation to the next in series. The SCALE lattice physics sequence TRITON generates few-group, assembly-homogenized cross sections, as a function of burnup and branch states, which can be input to core simulator codes. TRITON couples the ORIGEN-S depletion module with either the NEWT (NEW Transport algorithm) two-dimensional (2D) arbitrary-geometry transport code or the three-dimensional Monte Carlo KENO code. Fluxes from the transport solution, along with self-shielded multigroup (MG) cross sections, are passed to ORIGEN-S, which computes the time-dependent isotopic concentrations of more than 1400 nuclides. One of the major advancements in SCALE 6 is the availability of new nuclear data libraries based on ENDF/B-VII for neutron transport calculations. In this paper we describe the SCALE ENDF/B-VII (designated here as V7) libraries and present some validation results for critical benchmarks and isotopic depletion experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗