Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

A Case Study in Market Transformation for Residential Energy Efficiency Programs

This case study describes how the Midwest Energy Efficiency Alliance (MEEA) partnered with gas and electric utilities in Iowa to establish the Iowa residential heating, ventilation, and air conditioning System Adjustment and Verified Efficiency (HVAC SAVE) program, taking it to scale improving the performance and energy efficiency of HVAC systems, growing businesses, and gaining consumer trust.

Federal efficiency standards, installation practic↗

Mind the Gap: Summary of Window Residential Retrofit Solutions

Improving the insulation, solar heat gain, and infiltration characteristics of windows in a home has the potential to significantly improve the overall thermal performance by reducing heat transfer through the window and also by decreasing infiltration of outdoor air into the home. As approximately 43% of existing homes still have single-pane clear windows (~50 million houses) and millions of other homes have only double-pane clear windows (Cort 2013), improving window performance also presents a significant opportunity for energy savings in the residential sector. Today, various energy-saving window retrofit opportunities are available to homeowners, ranging from window coverings and storm panels to highly-insulating triple-pane R-5 window replacements. Many of these technologies have been evaluated in the field, in the “Lab Homes” at Pacific Northwest National Laboratory, and through modeling to prove their cost-effectiveness and performance in different climate regions. Recently, the Pacific Northwest’s Regional Technical Forum approved a utility measure for low- emissivity storm windows based on such data. This action represents a watershed moment for increasing the variety and prevalence of fenestration options in utility programs, especially for the low-income demographic. This paper will review various window retrofit options, the most recent field test and modeling data regarding their performance and cost-effectiveness, and discuss future rating efforts. This information is useful for utilities and energy-efficiency program managers to help effectively implement incentive measures for these technologies.

HVAC↗

Fast Primary Frequency Response Using Coordinated DER and Flexible Loads: Framework and Residential-Scale Demonstration: Preprint

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (about 8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Cost Impact of Non-Residential Energy Code Requirements

The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of the probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.

Energy Codes, code compliance↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings: Preprint

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coping with residential electricity demand in India’s future – How much can efficiency achieve?

The time when energy-related carbon emissions come overwhelmingly from developed countries is coming to a close. China will soon overtake the United States as the world’s leading emitter of greenhouse gas emissions. Meanwhile, India also seems to be on track to experience rapid long-term economic expansion. With this growth will surely come continued massive growth in energy demand. This paper explores the dynamics of that demand growth for one sector – residential electricity – and the realistic potential for coping with it through efficiency.

Letschert, Virginie↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Control for Residential HVAC Systems to Support Grid Services

In this paper, we propose an adaptive control strategy for residential buildings' heating ventilation and air conditioning (HVAC) systems to support grid services. The proposed control strategy captures the time-varying characteristics of the building and weather environments. It assigns to each building a local controller to maintain the indoor temperature within a desired comfort level, while the load aggregator allocates the assigned reference power provided by the distribution system operator to support a specific grid service, such as demand peak reduction, balancing supply and demand, and consuming the solar photovoltaic (PV) power locally. Simulation results are presented to verify the performance of the proposed control strategy in terms of maintaining the indoor temperatures of several buildings within the desired comfort bands while tracking the reference power profile. Also, a comparison with a recently developed model-free control strategy is presented.

Wu, Tumin↗

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

Residential Buildings: How Smart are Today’s Smart Homes?

Recent years have seen a dramatic increase in the number of “smart” devices available for residential buildings. This column describes opportunities presented by advances in smart home technology that could impact our homes and how we interact with them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scaling Deep Energy Retrofits for Residential Walls - Energy, Cost, and Economic Assessment of Five Wall Systems

Providing strong economic and performance value is a primary challenge of convincing homeowners to implement deep energy retrofits to their wall systems. This study combines energy modeling and technoeconomic assessment of six experimental residential retrofit wall systems to typical existing homes in cold climates to evaluate their energy performance and cost effectiveness. Deep energy retrofits can significantly improve the energy performance of a home’s thermal envelope, help manage indoor environmental pollutants, increase homeowner comfort, increase building value, and register significant energy and cost savings in the process. We are evaluating exterior wall retrofit components and construction practices to measure and recommend steps to improve financial performance for manufacturers, installers and consumers. This study leverages a literature review, inputs from an advisory group made up of thermal enclosure experts, and simulations to identify state-of-the-art technologies for energy efficient wall systems that are suitable for cold and very cold climate zones. This paper will present results from energy modeling of six experimental wall systems compared to one baseline, that inform cost and energy performance of the subject wall systems.

Ganguli, Sumitrra↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

A Peer-to-Peer Market-Based Control Strategy for a Smart Residential Community with Behind-the-Meter Distributed Energy Resources: Preprint

This paper presents a distributed peer-to-peer market control strategy to manage and to enable resource sharing of behind-the-meter distributed energy resources in a residential community. In the proposed strategy, each consumer or prosumer determines the flexibility of their point of connection to the power network such that the obtained flexibility is network-feasible. Based on the feasible flexibility, the consumers and the prosumers trade power among each other at each time instance to fulfill their preferred load requirements while maximizing their payoffs and helping to regulate node voltages inside the community. Because the problem to be solved is non-convex, a distributed particle swarm optimization algorithm is used to coordinate the consumers/prosumers in a fully autonomous manner without any centralized or hierarchical coordination. Numerical simulations performed on a community of 48 homes demonstrate the efficacy of the proposed approach.

behind-the-meter↗

Consumer Guide to Residential Solar Rooftop Potential

Learn about tools to estimate solar rooftop potential, or the amount of solar that could be installed on a residential or commercial rooftop. This fact sheet from Energy Saver also includes information about how installers estimate solar potential and why it's important.

solar, solar rooftop potential, Energy Saver↗

PCM Selection for Heat Pump Integrated with Thermal Energy Storage for Demand Response in Residential Buildings

Phase Change Materials (PCM) based Thermal energy storage (TES) is a widespread solution to shift buildings’ peak energy demand and add stability to the grid. PCMs can be used for space heating and cooling applications in residential buildings by integrating into the heat pump equipment or building envelope via several possible configurations. The heat pump integrated active PCM storage can provide significant energy savings and reduce peak demand, but the benefits vary substantially depending on the system configuration, storage capacity, and the temperature range of the PCM used. It is critical to provide a review of the materials and their suitability in heat pump integrated PCM systems. This paper will present an analysis of the PCM material selection for heat pump integrated TES in various configurations. The comprehensive review will compare the phase change materials with different melting temperatures, and configurations, corresponding to the energy savings and demand impact reported in the literature. This work is significant to guide the design of high-performance heat pump integrated PCM systems.

Sultan, Sara↗

User Friendly Web-Based Tool to Assess the Energy Efficiency and Durability of Residential Wall Retrofits

According to the U.S. Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies, building envelope wall energy loss in the United States accounts for about 5.9 x 1010 kWh or 2 quads of energy annually, costing homeowners and occupants billions of dollars. Enclosure retrofits targeting these losses can save significant energy, reduce greenhouse gas emissions, and save occupants millions of dollars over time. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established, represent approximately 68 percent of the residential building stock in the country, often having significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation have heating and cooling losses that can represent a substantial portion of utility bills.High-performance building envelope retrofit systems are rarely selected for retrofit applications. Current solutions are expensive and/or unfamiliar to many designers, builders, contractors, and code officials and therefore are perceived as risky. The dominant perceived risk is durability specifically related to condensation and moisture accumulation in the building envelope component.The Building Science Advisor (BSA) is a rule-based expert system web-based tool that was originally developed to assist building professionals in designing energy efficient and durable wall systems for new construction. With the present focus being placed on upgrading the existing building stock, a retrofit module has been developed that, based on the location, existing construction, and planned retrofit strategy, provides recommendations on how to address the retrofit in a manner that will perform in accordance with IECC 2018 building code and not create a durability problem. This paper will describe the development of this tool and demonstrate its features and capabilities.

Desjarlais, Andre Omer↗

A review of the residential efficient lighting programme rollout in South Africa

Efficient lighting for the residential sector in South Africa stemmed out of an electricity supply crisis. The Compact Fluorescent Lamps (CFL) rollout programme was carried out in the absence of a supporting policy. The implementation resulted in both desirable and undesirable outcomes. Of even greater concern is that a section of the market may be regressing to inefficient lighting. An analysis of lighting technologies available in the market shows that a shift to more energy efficient lighting technologies, such as light-emitting diodes (LED), will result in significant energy savings.

Covary, T↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗