Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Proportional counters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Variable Spin-Down in the Soft Gamma Repeater SGR 1900+14 and Correlations with Burst Activity

We have analyzed Rossi X-ray Timing Explorer Proportional Counter Array observation of the pulsed emission from SGR 1900+14 during September 1996, June-October 1998, and early 1999. Using these measurements and results reported elsewhere. we construct a period history of this source for 2.5 years. We find significant deviations from a steady spin-down trend during quiescence and the burst active interval. Burst And Transient Source Experiment (BATSE) observations of the burst emission are presented and correlations between the burst activity and spin-down rate of SGR 1900 + 14 are discussed. We find an 80 day interval during the summer of 1998 when the average spin-down rate is larger than the rate elsewhere by a factor of about 2.3. This enhanced spin-down may, be the result of a discontinuous spin-down event or "braking glitch" at the time of the giant flare on 27 August 1998. Furthermore find a large discrepancy between the pulsar period and average spin-down rate in X-rays as compared to radio observation for December 1998 and January 1999.

Woods, Peter M.↗

Radiation Measurements on the Russian MIR Orbital Station

The Russian Mir orbital station was launched into an orbit with a 51.65 deg inclination in March 1986. It has operated continuously in the altitude range of 380 to 460 km. Almost immediately, cosmonauts began to carry out missions to the station. To date, there have been some 25 Russian missions. As part of the NASA Mir Program, a comprehensive set of radiation measurements were made to map the radiation in all of the Mir module. Numerous radiation measurements have been made on the Mir station throughout its lifetime. However, the comparison of these measurements have been difficult because of different sensitivities of detectors, some active and some passive, differing self shielding and in most cases unknown location shielding. In spite of these complications, very significant progress in the knowledge of the radiation environment onboard the Mir station has been made. These results are directly applicable to expected radiation environment on the International Space Station. In this paper, we describe the combined results from all seven NASA Mir missions. We show: (1) the absorbed dose rate from trapped particles is well correlated with the atmospheric density computed nearly 400 days earlier than the time of observation, (2) developed a relationship between the absorbed dose rate from galactic cosmic rays to the deceleration potential derived using the Climax neutron monitor rate, giving a tool to predict GCR dose rates to +/- 15% nearly 90 days prior to observations, (3) describe the drift of the South Atlantic Anomaly (SAA) with time, (4) compare the predictions of the dose rates as a function of time from the November 6-8, 1998 solar particle event with observations, (5) compare measurements made with NASA Tissue Equivalent Proportional Counter (TEPC) with the ESA DOSTEL device, the Hungarian Pille system, and the Russian R-16 dosimeter. Implications of these measurements for the ISS will be discussed.

Badhwar, Gautam D.↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Variable Spin-Down in the Soft Gamma Repeater SGR 1900+14 and Correlations with Burst Activity

We have analyzed Rossi X-ray Timing Explorer Proportional Counter Array observations of the pulsed emission from SGR 1900+ 14 during 1996 September, 1998 June-October, and early 1999. Using these measurements and results reported elsewhere, we construct a period history of this source for 2.5 yr. We find significant deviations from a steady spin-down trend during quiescence and the burst active interval. Burst and Transient Source Experiment observations of the burst emission are presented and correlations between the burst activity and spin-down rate of SGR 1900+14 are discussed. We find an 80 day interval during the summer of 1998 when the average spin-down rate is larger than the rate elsewhere by a factor approximately 2.3. This enhanced spin-down may be the result of a discontinuous spin-down event or "braking glitch" at the time of the giant flare on 1998 August 27. Furthermore, we find a large discrepancy between the pulsar period and average spin-down rate in X-rays as compared to radio observations for 1998 December and 1999 January.

Woods, Peter M.↗

Background Simulation of the MSFC GSPC Balloon Payload

Numerical simulations are used to predict the cosmic-ray induced background in a passively shielded gas scintillation proportional counter to be used as the focal plane instrument of a balloon-borne hard x-ray telescope system. The predicted background in the 20-75 keV operating range of the detector shows a spectral shape characteristic of a power law photoelectrically absorbed by the stainless steel pressure vessel walls. It is found that the dominant background radiation component is simply cosmic diffuse and atmospheric gamma-ray leakage though there is a contribution from nuclear interactions of energetic particles in the walls and nearby payload structures. The correlation between shielding properties and background flux is examined parametrically using one-dimensional slab models, within material and weight constraints, in order to optimize predicted sensitivity. The addition of a few mm thick Sn passive shielding reduces the primary photon contribution by up to 50% at the spectral peak, E 150 keV, and adds only negligibly to the flux due to photon production within the high-Z shields at lower energies.

Swartz, D. A.↗

HERO: High Energy Replicated Optics for a Hard-X-Ray Balloon Payload

We are developing high-energy grazing-incidence replicated optics for a balloon-borne hard-x-ray telescope. When completed, the instrument will have 170 cm2 of effective collecting area at 40 keV and 130 square cm at 60 keV with <= 30 arc seconds half power diameter. This payload will offer unprecedented sensitivity in the hard-x-ray region, with around 250 microCrab sensitivity on long-duration flights and 50-100 microCrab on ultra- long-duration balloon missions The payload consists of 16 mirror modules, each with 14 nested mirrors made from a high-strength nickel alloy, and a corresponding array of 16 focal plane detectors. An engineering demonstration flight is scheduled for the Spring of 2000, using just two mirror modules each with 3 shells, above a pair of gas-scintillation-proportional counters. This flight is intended to test a newly designed gondola pointing and aspect system and the stability of the optical bench design. The first scientific flight of the full payload is scheduled for the Fall of 2002. Full details of the payload and its capabilities will be presented together with data from various mirror-module tests. If available data from the first flight will also be presented.

Ramsey, B.↗

Response of silicon-Based Linear Energy Transfer Spectrometers

Silicon-based linear energy transfer (LET) telescope,(e. g., DOSTEL and RRMD) have recently been flown in space. LET spectra measured using tissue equivalent proportional counters show differences that need to be fully understood. A Monte Carlo technique based on: 1. radiation transport cluster intra-cascade model. 2. Landau-Vavilov distribution, 3. telescope geometry and detector coincidence & discriminator settings, 4. spacecraft shielding geometry, and 5. the external free space radiation environment, including recent albedo measurements, was developed.

Aman, A.↗

XTE J1946+274 = GRO J1944+26 Observations with RXTE and BATSE

XTE J1946+274 = GRO J1944+26 is a 15.8 second transient X-ray pulsar discovered simultaneously with the Rossi X-ray Timing Explorer (RXTE) and Burst and Transient Source Experiment (BATSE) onboard the Compton Gamma Ray Observatory (CGRO) during an outburst in September 1998. Since its discovery, XTE J1946+274 has undergone 7 regularly spaced outbursts, that were observed with BATSE and the RXTE All-Sky Monitor (ASM). The pulse frequency and pulsed flux measurements with BATSE suggest that XTE J1946+274 is in an about 170 day orbit and is outbursting twice per orbit. The first outburst, which was brighter and longer than subsequent outbursts, was also observed with the RXTE Proportional Counter Array (PCA). We present histories of pulse frequency, pulsed flux, and total flux measured in the 20-50 keV band with BATSE and a history of the 2-10 keV total flux measured with the RXTE ASM. From the first outburst, we present energy and power spectra and pulse profiles from RXTE PCA observations.

Wilson, Colleen A.↗

Multiwire Gamma Camera for Radionuclide and Radiographic Imaging in the Space environment

Unique multiwire proportional counter technology has been developed at the Johnson Space Center over the past several years. The technology will be described and how it may apply both in near- and long-term NASA efforts. In the near-term, I feel that the technology will provide a significant tool for the cardiovascular research area. In particular, low-dose nuclear medicine and tissue densitometry techniques of expanded scope will be supplied. In the longer term, the multiwire technique can provide a general purpose radiology and nuclear medicine facility for use in the space station which would be difficult and costly to provide by other means.

Lacy, Jeffrey L.↗

XTE Science Briefing from KSCNF

The X-ray Timing Explorer (XTE), launched on Dec. 30, 1995, is a Satellite that observes the fast-moving, high-energy worlds of black holes, neutron stars, x-ray pulsars and bursts of X-rays that light up the sky and then disappear forever. This videotape presents a pre-launch science briefing to the press by a few of the scientist and managers associated with the XTE satellite. The moderator for the press briefing is Jim Sahli, from the Public Affairs Office at Goddard Space Flight Center (GSFC). He introduces Alan Bunner, of the High Energy Astrophysics at NASA Headquarters; Fred Lamb, from the University of Illinois; Richard Mashotzky, X Ray Scientist at GSFC; Rick Rothschild, Principal Investigator from the University of California at San Diego; and Dale Schultz, the XTE project manager at GSFC. Dr. Bunner explains the electromagnetic spectrum, the placement of x-rays and the importance of the XTE observations to a better understanding of the Universe. Dr. Lamb, explains the difference between white dwarfs, neutron stars and black holes, and the type of observations that the XTE will give to a further understanding of these phenomena. Dr. Mashotzky expands the viewpoint to beyond the galaxy, and explains the interests of scientists who hope to use XTE to further study Quasars and Active Galactic Nuclei. Dr. Rothschild reviews some of the features of XTE, using a diagram to show the features of interest, such as the X ray Telescopes, and the collecting Proportional Counter Array (PCA.) Mr. Schultz presents a videotape tour of the XTE, in which he shows the scientific instruments and the other features of the satellite. In this tour, the source of each of the instruments is noted. Questions from the members of the press are then fielded. Many of the questions are about the cost of the XTE and any problems that are anticipated in regards to the launch.

Source record↗

Statistical Properties of SGR 1900+14 Bursts

We study the statistics of soft gamma repeater (SGR) bursts using a database of 187 events detected with BATSE and 837 events detected with the Rossi X-Ray Timing Explorer Proportional Counter Array: all events are from SGR 1900+14 during its 1998-1999 active phase. We find that the fluence or energy distribution of bursts is consistent with a power law of index 1.66, over 4 orders of magnitude. This scale-free distribution resembles the Gutenberg-Richter law for earthquakes and gives evidence for self-organized criticality in SGRS. The distribution of time intervals between successive bursts from SGR 1900+14 is consistent with a lognormal distribution. There is no correlation between burst intensity and the waiting times till the next burst, but there is some evidence for a correlation between burst intensity and the time elapsed since the previous burst. We also find a correlation between the duration and the energy of the bursts, but with significant scatter. In all these statistical properties, SGR bursts resemble earthquakes and solar flares more closely than they resemble any known accretion-powered or nuclear-powered phenomena. Thus, our analysis lends support to the hypothesis that the energy source for SGR bursts is internal to the neutron star and plausibly magnetic.

Gogus, Ersin↗

Timing Noise in SGR 1806-20

We have phase connected a sequence of Rossi X-ray Timing Explorer Proportional Counter Array observations of SGR 1806-20 covering 178 days. We find a simple secular spin-down model does not adequately fit the data. The period derivative varies gradually during the observations between 8.1 and 11.7 x 10(exp -11) s/s (approx. 40% larger than the long term trend), while the average burst rate as seen with the Burst and Transient Source Experiment drops throughout the time interval. The phase residuals show no evidence for periodicity, but more closely resemble timing noise as seen ill radio pulsars. The magnitude of the timing noise., however, is large relative to the noise level typically found in radio pulsars (Delta(sub 8) = 4.8; frequency derivative average power approx. = 8 X 10(exp -20) Hz/sq s). Combined with the noise levels measured for some AXPs. we find all magnetar candidates have A8 values larger than those expected from a simple extrapolation of the correlation found in radio pulsars. We find the timing noise ill SGR 1806-20 is greater than or equal to the levels found in some accreting systems (e.g., Vela X-1, 4U 1538-52 and 4U 1626-67). Alternatively, an orbital model with a period P(sub orb) = 733 days provides a statistically acceptable fit to the data. If the phase residuals are created by Doppler shifts from a gravitationally bound companion. then the allowed parameter space for the mass function (small) and orbital separation (large) rule out the possibility of accretion from the companion sufficient to power the persistent emission from the SGR.

Woods, Peter M.↗

Relative Efficiency of TLD-100 to High Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to 137Cs) dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, G. D.↗

Relative Efficiency of TLD-100 to Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to (137)Cs dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, Gautam D.↗

Timing Noise in SGR 1806-20

We have phase-connected a sequence of Rossi X-Ray Timing Explorer Proportional Counter Array observations of SGR 1806-20 covering 178 days. We find that a simple secular spin-down model does not adequately fit the data. The period derivative varies gradually during the observations between 8.1 x 10(exp -11) and 11.7 x 10(exp -11) s/s (at its highest, approximately 40% larger than the long-term trend), while the average burst rate as seen with the Burst and Transient Source Experiment drops throughout the time interval. The phase residuals give no compelling evidence for periodicity, but more closely resemble timing noise as seen in radio pulsars. The magnitude of the timing noise, however, is large relative to the noise level typically found in radio pulsars (Delta(sub 8) = 4.8; frequency derivative average power approximately 7 x 10(exp -20) sq cycles/cubic s). Combining these results with the noise levels measured for some anomalous X-ray pulsars, we find that all magnetar candidates have Delta(sub 8) values larger than those expected from a simple extrapolation of the correlation found in radio pulsars. We find that the timing noise in SGR 1806-20 is greater than or equal to the levels found in some accreting systems (e.g., Vela X-1, 4U 1538-52, and 4U 1626-67), but the spin-down of SGR 1806-20 has thus far maintained coherence over 6 yr. Alternatively, an orbital model with a period P(sub orb) = 733 days provides a statistically acceptable fit to the data. If the phase residuals are created by Doppler shifts from a gravitationally bound companion, then the allowed parameter space for the mass function (small) and orbital separation (large) rule out the possibility of accretion from the companion sufficient to power the persistent emission from the SGR.

Woods, P. M.↗

A Newly Discovered Supernova Remnant and MSH 11-62 and 3C58

CTA 1 is a center-filled supernova remnant (SNR) whose morphology and spectrum indicate the presence of a central pulsar, a synchrotron nebula, and a thermal component associated with the expansion of the blast wave into the interstellar medium. The centrally bright emission surrounds the position of a faint point source of X-rays observed with the ROSAT Position Sensitive Proportional Counter (PSPC). Here we report on Advanced Spacecraft for Cosmology Astrophysics (ASCA) observations that confirm the nonthermal nature of the diffuse emission from the central regions of the remnant. We also present evidence for weak thermal emission that appears to increase in strength toward the outer boundary of the SNR. Thus, CTA 1 appears to be an X-ray composite remnant. Both the aftermath of the explosive supernova event and the energetic compact core are observable.

Slane, Patrick O.↗

X-Ray Constraints on the Warm-Hot Intergalactic Medium

Three observational constraints can be placed on a warm-hot intergalactic medium (WHIM) using ROSAT Position Sensitive Proportional Counter (PSPC) pointed and survey data, the emission strength, the energy spectrum, and the fluctuation spectrum. The upper limit to the emission strength of the WHIM is 7.5 +/- 1.0 keV/(s*sq cm*sr*keV) in the 3/4 keV band, an unknown portion of which value may be due to our own Galactic halo. The spectral stape of the WHIM emission can be described as thermal emission with logT = 6.42, although the true spectrum is more likely to come from a range of temperatures. The values of emission strength and spectral shape are in reasonable agreement with hydrodynamical cosmological models. The autocorrelation function in the 0.44 keV < E < 1.21 keV band range, w(theta), for the extragalactic soft X-ray background (SXRB) which includes both the WHIM and contributions due to point sources, is approx. < 0.002 for 10 min < 0 < 20 min in the 3/4 keV band. This value is lower than the Croft et al. (2000) cosmological model by a factor of approx. 5, but is still not inconsistent with cosmological models. It is also found that the normalization of the extragalactic power law component of the soft X-ray background spectrum must be 9.5 +/- 0.9 keV/(s*sq cm*sr*keV) to be consistent with the ROSAT All-Sky Survey.

Kuntz, K. D.↗

Relativistic Iron Emission and Disk Reflection in Galactic Microquasar XTE J1748-288

We report evidence for an Fe K-alpha fluorescence line feature and disk reflection in the very high, high-, and low-state X-ray spectra of the Galactic microquasar XTE J1748 - 288 during its 1998 June outburst. Spectral analyses are made on data gathered throughout the outburst by the Rossi X-Ray Timing Explorer Proportional Counter Array. Gaussian line, relativistic disk emission line, and ionized disk reflection models are fitted to the data. In the very high state the line profile appears strongly redshifted, consistent with disk emission from the innermost stable orbits around a maximally rotating Kerr black hole. In the high state the line profile is less redshifted and increasingly prominent. The low-state line profile is very strong (approx. 0.5 keV equivalent width) and centered at 6.7 +/- 0.10 keV; disk line emission model fits indicate that the inner edge of the disk fluctuates between approx. 20R(sub g) and - approx. 100R(sub g) in this state. The disk reflection fraction is traced through the outburst; reflection from an ionized disk is preferred in the very high and high states, and reflection from a relatively neutral disk is preferred in the low state. We discuss the implications of our findings for the binary system dynamics and accretion flow geometry in XTE J1748 - 288.

Miller, J. M.↗