Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Program verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Industry Level Feasibility of LiDAR Data into Fire Modeling Using Fire Risk Investigation in 3D (FRI3D)

Many evaluation, assessment, and modeling tasks at nuclear power plants require spatial information this often requires physical visits to locations within the facility because the 2D or 3D schematics and current models do not contain enough detail or do not capture as-built and real-world conditions. These visits require extensive manual labor for not only the requesting party, but support groups such as security. LIDAR mapping is trying to solve that problem by providing very detailed 3D models for low costs. However, the use of these models can be very limited because either component reference information is missing and too costly to add, or there is no way to extract specific spatial data needed for other tools. This report presents Idaho National Lab's work with Environmental Intellect (Ei) covering two main efforts. First, to reduce the effort of "tagging" data in large 3D models. By using both existing plant database information, and artificial intelligence (AI) to find and read equipment labels. This research explores the ability of to provide a simple way for the user to tag items and verify plant data, capturing both the speed of AI and human verification. The second part of the work is the development of an interface for importing pieces needed for Modeling & Simulation. Analysis work such as that for fire, flood, or physical security all require spatial or 3D models in various levels of detail. This interface will allow for the retrieval of item location or boundaries, enabling the auto generation of models for varying tools. The application program interface (API) of the fire risk investigation in 3D (FRI3D) was used to test feasibility of exporting the LiDAR tagged spatial information. Outcomes from this work provide preliminary data to determine if the tools and methods could provide substantial industry benefit if fully matured.

97 MATHEMATICS AND COMPUTING↗

Integrated Solutions for Optimized Performance (ISOP) Final Technical Report

The goal of this project was to demonstrate technical feasibility of an integrated approach for deep energy retrofits by packaging innovative technologies with smart communicating controls that represent the next generation of energy efficiency. The integrated solutions for optimized performance (ISOP) package integrates (i) advanced lighting and plug load controls; (ii) intelligent daylight harvesting through automated self-powered shades and window films; (iii) advanced HVAC controls sequences (ASHRAE Guideline (GDL) 36); and (iv) fault detection and diagnosis (FDD) and continuous commissioning (CCx) using advanced analytics. These technologies address energy use across multiple building end uses that represent more than 60% of the energy consumption in all commercial buildings. The project was structured to be implemented over three budget periods: Budget Period 1 scope included site selection, project design, site-specific customization of technology packages, procurement of technologies, initiation of installation of technologies, the development of a measurement and verification plan and collection of pre-retrofit data collection. The first year go/no-go decision was based on securing host sites representing 250,000 sq. ft. of occupied operational spaces, savings analysis, technology procurement and initiation of installation. Budget Period 2 planned to complete technology installations and initiate data collection of post-retrofit performance data. The second year go/no-go was to be the completion of technology installations and commissioning, metering and data collecting to support the requirements laid out in site specific M&V plans. Budget Period 3 planned to collect and analyze post-retrofit performance data and provide data and reporting to support energy efficiency rebate programs. After the team completed activities planned for Budget Period 1, the team reached a Go/No-Go Decision Point. At that point, TRC recommended that DOE discontinue the project without prejudice due to challenges with securing demonstration sites to meet the full 250,000 sf of occupied operational spaces and DOE concurred. In Budget Period 1, the TRC team developed criteria to recruit and evaluate potential demonstration host sites. TRC worked with Princeton University, the project demonstration partner, to identify buildings on their campus as potential candidates for the demonstration. Following the selection of demonstration sites, the TRC team customized energy technology packages according to the needs and characteristics of each site. TRC defined technology specifications, identified vendors, and conducted analysis to estimate energy and cost savings potential. The project team then developed schedules for technology procurement processes and scheduled for installation at all selected demonstration sites. The project team worked with Princeton University and DOE to develop an approach to verify energy savings achieved through measurement and verification (M&V) 2.0 methods. Princeton University initiated open bids to procure the necessary materials and installation contractors. Bid results came back higher than estimates due to a couple of factors – lack of familiarity of the bidders with the proposed technologies and lack of local trained installers to execute the installation of these new measures. Due to the higher bids, projects no longer met the internal cost-effectiveness criteria used by Princeton to proceed with procurement of the full suite of technologies as proposed in ISOP. Princeton had already procured parts of the ISOP package as part of a campus-wide initiative for FDD and lighting retrofits, but with the higher costs for other ISOP components, Princeton could no longer commit to the full ISOP package on the selected sites. Based on this, the team reached the Go/No-Go decision point, where they decided not to proceed with the project. Princeton is separately installing portions of the ISOP package where they individually meet Princeton’s payback criteria but on a different schedule than would have been needed for the DOE ISOP project. The team has learned several lessons from project progress in the first budget period. The team will utilize these lessons in future projects, as should any team which proceeds with a project around the ISOP technology. The first lesson is that more information about the proposed sites is required earlier in the process (perhaps even at the proposal stage) in order to have a successful demonstration. Technical details not evident earlier in the process (such as the TLED limitations for ALCS) can derail project execution. The second lesson is that pricing of emerging technologies is highly variable due to lack of familiarity of local installers and distributor with the proposed technologies as well as alternate bids using products they were more familiar with, but that cost more than the ones proposed by TRC. Finally, the last major lesson is that the host site’s internal project criteria is of critical importance. Based on these higher installed costs and lack of an informed installer base for the products proposed for this project, the project does not meet Princeton’s simple payback goals of five years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Axom

Axom is an open-source library of "building block" software components that provide core infrastructure capabilities for HPC applications. Such capabilities include: input file parsing and verification for various file formats, format specification for material shape input to multi-material simulations and tools for placing those shapes on meshes, parallel distributed coordination of diagnostic messages, geometric primitives, spatial queries and spatial search acceleration data structures, in memory key-value data store for managing simulation data and parallel file I/O. Axom components are used widely across LLNL Advanced Simulation and Computing program applications. It is also part of the LLNL institutionally-supported RADIUSS project, which promotes and funds its adoption by projects across LLNL.

Zagaris, George↗

DARMA-Kokkos Data and Execution Interoperability WBS 2.3.1.04 Milestone 16 (ECP Milestone Report)

DARMA (Distributed Asynchronous Resilient Models for Applications) is a runtime library supporting the Sandia ATDM (Advanced Technology Development and Mitigation) program. The main application drivers fall within the ECP milestone 2.2.5.03 ADNN03-ASC ATDM SNL Application, which includes applications that require load balancing and asynchronous communication for high performance. The DARMA runtime infrastructure has been modified to be compatible with Kokkos/OpenMP parallelization within tasks, which is a critical requirement for high performance for the Sandia ATDM apps. DARMA development has occurred in parallel with a verification milestone for ATDM in FY18. For FY19, DARMA should impact ATDM by enabling dynamic load balancing and communication through only incremental changes to the existing verified MPI codes. DARMA can now support the intra-kernel thread parallelization in the parent MPI apps, allowing DARMA to be easily added without rewriting individual math kernels. The results presented here demonstrate the DARMA results for an MPI mini-app.

97 MATHEMATICS AND COMPUTING↗

SU-G-TeP1-06: Fast GPU Framework for Four-Dimensional Monte Carlo in Adaptive Intensity Modulated Proton Therapy (IMPT) for Mobile Tumors

Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) treatment planning and verification using four-dimensional CT (4DCT) for adaptive IMPT for lung cancer patients. Methods: A validated GPU MC code, gPMC, has been linked to the patient database at our institution and employed to compute the dose-influence matrices (Dij) on the planning CT (pCT). The pCT is an average of the respiratory motion of the patient. The Dijs and patient structures were fed to the optimizer to calculate a treatment plan. To validate the plan against motion, a 4D dose distribution averaged over the possible starting phases is calculated using the 4DCT and a model of the time structure of the delivered spot map. The dose is accumulated using vector maps created by a GPU-accelerated deformable image registration program (DIR) from each phase of the 4DCT to the reference phase using the B-spline method. Calculation of the Dij matrices and the DIR are performed on a cluster, with each field and vector map calculated in parallel. Results: The Dij production takes ∼3.5s per beamlet for 10e6 protons, depending on the energy and the CT size. Generating a plan with 4D simulation of 1000 spots in 4 fields takes approximately 1h. To test the framework, IMPT plans for 10 lung cancer patients were generated for validation. Differences between the planned and the delivered dose of 19% in dose to some organs at risk and 1.4/21.1% in target mean dose/homogeneity with respect to the plan were observed, suggesting potential for improvement if adaptation is considered. Conclusion: A fast MC treatment planning framework has been developed that allows reliable plan design and verification for mobile targets and adaptation of treatment plans. This will significantly impact treatments for lung tumors, as 4D-MC dose calculations can now become part of planning strategies.

60 APPLIED LIFE SCIENCES↗

MITR Low-Enriched Uranium Conversion Fluid-Structure Interaction Preliminary Design Verification

The U.S. National Nuclear Security Administration (NNSA) Office of Material Management and Minimization (M 3 ) has developed and is pursuing an integrated approach to address the persistent threat posed by unintentional proliferation of nuclear materials. The NNSA M 3 approach reduces the risk of highly enriched uranium (HEU) and plutonium falling into the hands of non-state actors by minimizing the use of and, when possible, eliminating weapons-usable nuclear material around the world. In this geopolitical context, most research and test reactors, both domestic and international, have completed or started a program of conversion from the use of HEU to low-enriched uranium (LEU) as fuel. Conversion of civilian research reactors from HEU to LEU, and the return of the HEU to the country of origin, are important components of the NNSA non-proliferation program. Worldwide, 71 reactors have been converted to the use of LEU fuel, and an additional 32 have been confirmed to be permanently shut down. The U.S., with 20 reactor conversions, is among the 39 countries on six continents where conversions have occurred. With recent conversions in Ghana and Nigeria, an important milestone was reached in completing conversion of all reactors on the continent of Africa to LEU fuel. Africa thus becomes the third continent to have completed conversion of all HEU reactors to LEU, following Australia and South America

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Permeability Ternary Palladium Alloy Membranes with Improved Sulfur and Halide Tolerances

The project team consisting of Southwest Research Institute{reg_sign} (SwRI{reg_sign}), Georgia Institute of Technology (GT), the Colorado School of Mines (CSM), TDA Research, and IdaTech LLC was focused on developing a robust, poison-tolerant, hydrogen selective free standing membrane to produce clean hydrogen. The project completed on schedule and on budget with SwRI, GT, CSM, TDA and IdaTech all operating independently and concurrently. GT has developed a robust platform for performing extensive DFT calculations for H in bulk palladium (Pd), binary alloys, and ternary alloys of Pd. Binary alloys investigated included Pd96M4 where M = Li, Na, Mg, Al, Si, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Y, Zr, Nb, Mo, Tc, Ru, Rh, Ag, Cd, In, Sn, Sb, Te, Hf, Ta, W, Re, Os, Ir, Pt, Au, Tl, Pb, Bi, Ce, Sm, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu. They have also performed a series of calculations on Pd{sub 70}Cu{sub 26}Ag{sub 4}, Pd{sub 70}Cu{sub 26}Au{sub 4}, Pd{sub 70}Cu{sub 26}Ni{sub 4}, Pd{sub 70}Cu{sub 26}Pt{sub 4}, and Pd{sub 70}Cu{sub 26}Y{sub 4}. SwRI deposited and released over 160 foils of binary and ternary Pd alloys. There was considerable work on characterizing and improving the durability of the deposited foils using new alloy compositions, post annealing and ion bombardment. The 10 and 25 {micro}m thick films were sent to CSM, TDA and IdaTech for characterization and permeation testing. CSM conducted over 60 pure gas permeation tests with SwRI binary and ternary alloy membranes. To date the PdAu and PdAuPt membranes have exhibited the best performance at temperatures in the range of 423-773 C and their performance correlates well with the predictions from GT. TDA completed testing under the Department of Energy (DOE) WGS conditions on over 16 membranes. Of particular interest are the PdAuPt alloys that exhibited only a 20% drop in flux when sulfur was added to the gas mixture and the flux was completely recovered when the sulfur flow was stopped. IdaTech tested binary and ternary membranes on a simulated flue gas stream and experienced significant difficulty in mounting and testing the sputter deposited membranes. IdaTech was able to successfully test PdAu and PdAuPt membranes and saw similar sulfur tolerance to what TDA found. The Program met all the deliverables on schedule and on budget. Over ten presentations at national and international conferences were made, four papers were published (two in progress) in technical journals, and three students (2 at GT and 1 at CSM) completed their doctorates using results generated during the course of the program. The three major findings of program were; (1) the DFT modeling was verified as a predictive tool for the permeability of Pd based ternary alloys, (2) while magnetron sputtering is useful in precisely fabricating binary and ternary alloys, the mechanical durability of membranes fabricated using this technique are inferior compared to cold rolled membranes and this preparation method is currently not ready for industrial environments, (3) based on both modeling and experimental verification in pure gas and mixed gas environments PdAu and PdAuPt alloys were found to have the combination of the highest permeability and tolerance to sulfur.

08 HYDROGEN↗

Task I: Dark Matter Search Experiments with Cryogenic Detectors: CDMS-I and CDMS-II Task II: Experimental Study of Neutrino Properties: EXO and KamLAND

Dark Matter Search - During the period of performance, our group continued the search for dark matter in the form of weakly interacting massive particles or WIMPs. As a key member of the CDMS (Cryogenic Dark Matter Search) collaboration, we completed the CDMS II experiment which led the field in sensitivity for more than five years. We fabricated all detectors, and participated in detector testing and verification. In addition, we participated in the construction and operation of the facility at the Soudan Underground Laboratory and played key roles in the data acquisition and analysis. Towards the end of the performance period, we began operating the SuperCDMS Soudan experiment, which consists of 15 advanced Ge (9 kg) detectors. The advanced detector design called iZIP grew out of our earlier DOE Particle Detector R&D program which demonstrated the rejection of surface electrons to levels where they are no longer the dominant source of background. Our group invented this advanced design and these larger detectors were fabricated on the Stanford campus in collaboration with the SLAC CDMS group and the Santa Clara University group. The sensitivity reach is expected to be up to 5 times better than CDMS II after two years of operation. We will check the new limits on WIMPs set by XENON100, and we expect improved sensitivity for light mass WIMPs beyond that of any other existing experiment. Our group includes the Spokesperson for SuperCDMS and continues to make important contributions to improvements in the detector technology which are enabling the very low trigger thresholds used to explore the low mass WIMP region. We are making detailed measurements of the charge transport and trapping within Ge crystals, measuring the diffusive trapping distance of the quasiparticle excitations within the Al phonon collector fins on the detector surface, and we are contributing to the development of much improved detector Monte Carlos which are essential to guide the detector design and optimize the analysis. Neutrino Physics – In the period of performance the neutrino group successfully completed the construction of EXO-200 and commissioned the detector. Science data taking started on Jun 1, 2011. With the discovery of the 2-neutrino double-beta decay in 136-Xe and the first measurement of the 0-neutrino mode resulting in the most stringent limit of Majorana masses, our group continues to be a leading innovator in the field of neutrino physics which is central to DOE-HEP Intensity Frontier program. The phenomenon of neutrino oscillations, in part elucidated by our earlier efforts with the Palo Verde and KamLAND experiments, provides the crucial information that neutrino masses are non-zero and, yet, it contains no information on the value of the neutrino mass scale. In recent times our group has therefore shifted its focus to a high sensitivity 0-neutrino double beta decay program, EXO. The 0-neutrino double beta decay provides the best chance of extending the sensitivity to the neutrino mass scale below 10 meV but, maybe more importantly, it tests the nature of the neutrino wave function, providing the most sensitive probe for Majorana particles and lepton number violation. The EXO program, formulated by our group several years ago, plans to use up to tonnes of the isotope 136-Xe to study the 0-neutrino double beta decay mode. The EXO-200 detector is the first step in this program and it represents the only large US-led and based experiment taking data. The EXO-200 isotope enrichment program broke new grounds for the enterprise of double beta decay. The detector design and material selection program paid off, resulting in a background that is among the very best in the field. The “first light" of EXO-200 was very exciting with the discovery -in the first month of data- of the rarest 2-neutrino double beta decay mode ever observed. The lower limit on the 0-neutrino double beta decay half-life, published in Phys. Rev. Lett. and based on the first 120 days of data is the second best but, when translated into a Majorana mass scale, it is one of the most stringent constraint we have on neutrino masses. Indeed, such a limit was the first result to contradict a claim of discovery in 76-Ge for most nuclear matrix elements calculations. As we continue data taking and plan some modest upgrades to EXO-200 our group is also very active in the design of nEXO, a 5 tonne detector based on the technology demonstrated by EXO-200. Over the years we have made it a tradition to explore the frontier and not to be shy about looking in new directions and re-inventing ourselves to best take advantage of the precious few opportunities provided by Nature. We have also cultivated a number of young people at all levels and, by now, many of the undergraduates, graduate students and postdocs educated by this group have leading positions in academia and industry around the world.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2021 Small Turbine Certification Awardee: Intergrid LLC

Currently, there are no U.S., fully certified inverters for wind turbines in the 10-15-kilowatt (kW) range. The federal government's Competitiveness Improvement Project (CIP) and Small Business Innovation Research programs present the most viable paths for manufacturers in the distributed wind energy industry to conduct research, develop their products, and, ultimately, commercialize them. Through CIP, Intergrid LLC is reducing the cost, size, and weight of its legacy inverter for distributed wind turbines while increasing efficiency, reliability, and serviceability. To accomplish this, Intergrid will address three areas related to power electronics for distributed wind turbines: (1) Software verification and functional safety certification; (2) Simulation for grid-interconnecting testing; (3) Component alternatives that reduce cost and improve reliability and serviceability. The first two areas relate to long-term management of inverter software, which, for grid-connected inverters, must comply with three standards - one issued by Underwriters Laboratories (UL) and two issued by the Institute of Electrical and Electronics Engineers.

CIP↗

NCSP – AWE Collaboration [Slides]

Several points of collaboration between NCSP and AWE are noted, including the CIDAAS IS589 installation plan, CIDAAS testing, nuclear verification and detector physics, nuclear material control and nuclear security, and hands on criticality safety training.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electric System Intra-hour Operation Simulator

ESIOS is a software program developed at Pacific Northwest National Laboratory (PNNL) that performs intra-hour dispatch and automatic generation control (AGC) simulations for electric power system frequency regulation and load/variable generation following. The program dispatches generation resources at minute interval to meet control performance requirements, while incorporating stochastic models of forecast errors and variability with generation, load, interchange and market behaviors. The simulator also contains an operator model that mimics manual actions to adjust resource dispatch and maintain system reserves. Besides simulating generation fleet intra-hour dispatch, ESIOS can also be used as a test platform for the design and verification of energy storage, demand response, and other technologies helping to accommodate variable generation.

Lu, Shuai↗

SAS4A/SASSYS-1 VERIFICATION AND VALIDATION TEST SUITE

SAS4A/SASSYS-1 is a safety analysis software package already under copyright by Argonne National Laboratory. There is interest from third-party users of the software to gain access to our internal verification and validation test suite. Therefore we are seeking to establish copyright over the test suite, which includes input files and reference results for hundreds of test cases that demonstrate functionality of the software. Making the test suite available to licensed users allows them to utilize the broad range of tests for commercial grade dedication activities needed to qualify the SAS4A/SASSYS-1 software under their own Software Quality Assurance program for use in a regulatory environment (e.g. with the Nuclear Regulatory Commission).

FANNING, THOMAS↗

Am-241 Nuclear Safety and Environmental Interactions

NASA’s supply of radioisotopes for Radioisotope Heat Units (RHU) and Radioisotope Thermoelectric Generator (RTG) power sources is facing a crisis due to shortages of Pu-238 for future missions. Am-241 is a possible replacement for Pu-238 since its stockpile from the nuclear weapons program has remained relatively intact. The purpose of this project was to assess the safety of Am-241 and the risks associated with it as compared with PU-238. The project has resulted in a journal article, F. De-La-Torre-Aguilar, N. White, M. Prelas, R. V. Tompson, and S. K. Loyalka "Space nuclear power system accidents: Doses from Pu-238 and Am- 241 inhalation," Progress in Nuclear Energy vol.100C (2017), pp.171-182, which showed that the radiation dosage resulting from Am-241 inhalation are about 1/2.5 of the dosage resulting from Pu-238 inhalation per KW of Pu-238 power. Considerable progress was also made on the Direct Simulation Monte Carlo Method (DSMC) for simulation of aerosol evolution during accidents resulting in three publications: 1.I. Saldivar, F. De-La-Torre-Aguilar, M. Boraas, and S. K. Loyalka “Benchmark problems in aerosol evolution: Comparison of some exact and DSMC results” in Annals of Nuclear Energy vol.117 (2018), pp.213-222. 2. I. Saldivar and S. K. Loyalka, “Evolution of Aerosols Coupled to Environments: Verification of Direct Simulation Monte Carlo (DSMC)”, Nuclear Technology 204 (2018), pp.172-183. 3. M. Boraas and S. K. Loyalka, “Mesh Free Simulation of Spatially Inhomogeneous aerosols in Arbitrary Geometries” Nuclear Science and Engineering (2018). Further, we have computations on Am-241/Pu-238 vapor and aerosol interactions, and found that the vapor condensation rate is relatively insensitive to the mass effects, confirming some previous results. We have also completed computations of charge effects on evolution of different species aerosols and a manuscript is in preparation. Additionally, we have compared atmospheric dispersion and deposition of Pu-238 and Am-241 using the HYSPLIT code. We have also used a real lung model and the CFD program FLUENT to compute PuO2 and AmO2 deposition to explore improvements upon the ICPR-66 model. We have found that the deposition efficiencies of PuO2 and AmO2 are similar. These results (four manuscripts) will be submitted for publication in the post project period. We have made progress using framework of Mars 2020 mission nuclear risk assessment model to integrate all results, but our progress has been limited as the improved consequence modeling itself has been quite involved and challenging. We will integrate and complete the more extensive risk modeling computations and publish the results in the post-project period. In addition to the above, the project has resulted in research training of four PhD students

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Strategic Plan for Nuclear Energy -- Knowledge Base for Advanced Modeling and Simulation (NE-KAMS)

The Nuclear Energy Computational Fluid Dynamics Advanced Modeling and Simulation (NE-CAMS) system is being developed at the Idaho National Laboratory (INL) in collaboration with Bettis Laboratory, Sandia National Laboratory (SNL), Argonne National Laboratory (ANL), Utah State University (USU), and other interested parties with the objective of developing and implementing a comprehensive and readily accessible data and information management system for computational fluid dynamics (CFD) verification and validation (V&V) in support of nuclear energy systems design and safety analysis. The two key objectives of the NE-CAMS effort are to identify, collect, assess, store and maintain high resolution and high quality experimental data and related expert knowledge (metadata) for use in CFD V&V assessments specific to the nuclear energy field and to establish a working relationship with the U.S. Nuclear Regulatory Commission (NRC) to develop a CFD V&V database, including benchmark cases, that addresses and supports the associated NRC regulations and policies on the use of CFD analysis. In particular, the NE-CAMS system will support the Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program, which aims to develop and deploy advanced modeling and simulation methods and computational tools for reliable numerical simulation of nuclear reactor systems for design and safety analysis. Primary NE-CAMS Elements There are four primary elements of the NE-CAMS knowledge base designed to support computer modeling and simulation in the nuclear energy arena as listed below. Element 1. The database will contain experimental data that can be used for CFD validation that is relevant to nuclear reactor and plant processes, particularly those important to the nuclear industry and the NRC. Element 2. Qualification standards for data evaluation and classification will be incorporated and applied such that validation data sets will result in well-defined, well-characterized data. Element 3. Standards will be established for the design and operation of experiments for the generation of new validation data sets that are to be submitted to NE-CAMS that addresses the completeness and characterization of the dataset. Element 4. Standards will be developed for performing verification and validation (V&V) to establish confidence levels in CFD analyses of nuclear reactor processes; such processes will be acceptable and recognized by both CFD experts and the NRC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Department of Energy Operational Readiness Review for the Waste Isolation Pilot Plant

The U.S. Department of Energy (DOE) has completed an Operational Readiness Review (ORR) for the restart of Contact Handled (CH) waste emplacement at the Waste Isolation Pilot Plant (WIPP) located near Carlsbad, New Mexico. The ORR team assessed the readiness of Nuclear Waste Partnership, LLC (NWP) to manage and perform receipt through CH waste emplacement, and associated waste handling and management activities, including the ability of the National TRU Program (NTP) to evaluate the waste currently stored at the WIPP site against the revised and enhanced Waste Acceptance Criteria (WAC). Field work for this review began on November 14, 2015 and was completed on November 30, 2016. The DOE ORR was conducted in accordance with the Department of Energy Operational Readiness Review Implementation Plan for the Waste Isolation Pilot Plant, dated November 8, 2016, and DOE Order 425.1D, Verification of Readiness to Start Up or Restart Nuclear Facilities. The review activities included personnel interviews, record reviews, direct observation of operations and maintenance demonstrations, and observation of multiple operational and emergency drills/exercises. The DOE ORR also evaluated the adequacy of the contractor’s ORR (CORR) and the readiness of the DOE Carlsbad field Office (CBFO) to oversee the startup and execution of CH waste emplacement activities at the WIPP facility. The WIPP facility is categorized as a Hazard Category 2 DOE Nonreactor Nuclear Facility for all surface and Underground (UG) operations per DOE-STD-1027-92, Hazard Categorization and Accident Analysis Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports. In addition, the WIPP experienced two events in February, 2014 that resulted in Accident Investigations being performed in accordance with the requirements of DOE Order 225.1B, Accident Investigations. Based upon the results of the accident investigations and hazard categorization of the facility, the team placed significant emphasis on the following areas: fire protection, emergency preparedness, radiological protection, nuclear safety, and operations. The identification of specific focus areas was not intended to diminish the importance of other areas of the review, but to ensure that these areas received a particularly thorough and in-depth evaluation due to their significance with respect to the safe operation of the facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Xyce Case Study

With the elimination of underground nuclear testing and declining defense budgets, science-based stockpile stewardship requires increased reliance on high performance modeling and simulation of weapon systems. Today's weapon systems are comprised of various electrical components and systems. As a result, there is a need for tools that will allow the use of massively parallel modeling and simulation techniques on high performance computers in existing and future weapons' electrical systems models. The Xyce Parallel Electronic Simulator is a SPICE (Simulation Program with Integrated Circuit Emphasis)- compatible circuit simulator designed to run on large-scale parallel computing platforms, though it can also execute efficiently on a variety of architectures including single processor workstations. As a mature platform for large-scale parallel circuit simulation, Xyce supports standard capabilities available in commercial simulators, in addition to various devices and models specific to Sandia's needs. Specifically, Xyce aids in the design and verification of electrical and electronic circuits and systems prior to weapons' manufacturing and deployment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Xyce Case Study

With the elimination of underground nuclear testing and declining defense budgets, science-based stockpile stewardship requires increased reliance on high performance modeling and simulation of weapon systems. Today's weapon systems are comprised of various electrical components and systems. As a result, there is a need for tools that will allow the use of massively parallel modeling and simulation techniques on high performance computers in existing and future weapons' electrical systems models. The Xyce Parallel Electronic Simulator is a SPICE (Simulation Program with Integrated Circuit Emphasis)- compatible circuit simulator designed to run on large-scale parallel computing platforms, though it can also execute efficiently on a variety of architectures including single processor workstations. As a mature platform for large-scale parallel circuit simulation, Xyce supports standard capabilities available in commercial simulators, in addition to various devices and models specific to Sandia's needs. Specifically, Xyce aids in the design and verification of electrical and electronic circuits and systems prior to weapons' manufacturing and deployment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SU-E-J-117: Verification Method for the Detection Accuracy of Automatic Winston Lutz Test

Purpose: Winston Lutz test (WLT) has been a standard QA procedure performed prior to SRS treatment, to verify the mechanical iso-center setup accuracy upon different Gantry/Couch movements. Several detection algorithms exist,for analyzing the ball-radiation field alignment automatically. However, the accuracy of these algorithms have not been fully addressed. Here, we reveal the possible errors arise from each step in WLT, and verify the software detection accuracy with the Rectilinear Phantom Pointer (RLPP), a tool commonly used for aligning treatment plan coordinate with mechanical iso-center. Methods: WLT was performed with the radio-opaque ball mounted on a MIS and irradiated onto EDR2 films. The films were scanned and processed with an in-house Matlab program for automatic iso-center detection. Tests were also performed to identify the errors arise from setup, film development and scanning process. The radioopaque ball was then mounted onto the RLPP, and offset laterally and longitudinally in 7 known positions ( 0, ±0.2, ±0.5, ±0.8 mm) manually for irradiations. The gantry and couch was set to zero degree for all irradiation. The same scanned images were processed repeatedly to check the repeatability of the software. Results: Miminal discrepancies (mean=0.05mm) were detected with 2 films overlapped and irradiated but developed separately. This reveals the error arise from film processor and scanner alone. Maximum setup errors were found to be around 0.2mm, by analyzing data collected from 10 irradiations over 2 months. For the known shift introduced using the RLPP, the results agree with the manual offset, and fit linearly (R{sup 2}>0.99) when plotted relative to the first ball with zero shift. Conclusion: We systematically reveal the possible errors arise from each step in WLT, and introduce a simple method to verify the detection accuracy of our in-house software using a clinically available tool.

60 APPLIED LIFE SCIENCES↗