Design and Technoeconomic Analysis of High-Temperature Particle Conveyance Components for a 100 MW e Concentrating Solar Power Plant

Levelized costs of electricity (LCOE) approaching the U.S. Department of Energy Solar Energy Technologies Office 2030 goal of 0.05 $/kWh may be achievable using Brayton power cycles that use supercritical CO2 as the working fluid and flowing solid particles with temperatures >700° C as the heat transfer media. The handling and conveyance of bulk solid particles at these temperatures in an insulated environment is a critical technical challenge that must be solved for this approach to be used. A design study was conducted at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories in Albuquerque, NM, with the objective of identifying the technical readiness level, performance limits, capital and O&M costs, and expected thermal losses of particle handling and conveyance components in a particle-based CSP plant. Key findings indicated that chutes can be a low-cost option for particle handling but uncertainties in tower costs make it difficult to know whether they can be cost effective in areas above the receiver if tower heights must then be increased. Skips and high temperature particle conveyance technology are available for moving particles up to 640° C. This limits the use of mechanical conveyance above the heat exchanger and suggests vertical integration of the hot storage bin and heat exchanger to facilitate direct gravity fed handling of particles.

14 SOLAR ENERGY↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2020

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While many projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2020, as well as data on "completed" and "withdrawn" projects for five of the ISOs (CAISO, ISO-NE, MISO, NYISO, PJM). We find that the total capacity active in the queues is growing year-over-year, with over 750 GW of generation and an estimated 200 GW of storage capacity as of the end of 2020. Solar (462 GW) accounts for a large – and growing – share of generator capacity in the queues. Substantial wind (209 GW) capacity is also in development, 29% of which is for offshore projects (61 GW). In total, about 680 GW of zero-carbon capacity is currently seeking transmission access, as is 74 GW of natural gas capacity. Hybrids now comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 159 GW of solar hybrids (primarily solar+battery) and 13 GW of wind hybrids are currently active in the queues. However, much of this proposed capacity will not ultimately be built. Among a subset of queues for which data are available, only 24% of the projects seeking connection from 2000 to 2015 have subsequently been built. Completion percentages appear to be declining, and are even lower for wind and solar than other resources. Additionally, wait times are on the rise: in four ISOs, the typical duration from connection request to commercial operation increased from ~1.9 years for projects built in 2000-2009 to ~3.5 years for those built in 2010-2020. There are growing calls for queue reform to reduce cost, lead times, and speculation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ELECTRICAL BREAKDOWN STRENGTH AND AC WITHSTAND IN HARVESTED EPR INSULATIONS FOR NUCLEAR POWER PLANTS

While the operating voltages for some instrument and control (I&C) cables can be greater than 4 kV to operate pumps, controls, and provide auxiliary power, the operating voltage for most I&C cables is near 600 V. Although the electrical stress is not nearly as high in the insulation of these cables, an ac withstand two and one-half times greater than the operating voltage after a simulated design basis exposure (DBE) has been used in environmental qualification (EQ) to determine the ability of an insulation to meet a 40-year lifetime at an operating voltage. While multiple cable lengths greater than 10 feet are needed to replicate this EQ, systematic measurement of the electrical insulation strength in harvested cable insulations can be beneficial to better understand the remaining useful life of the insulation. This understanding can only be realized through systematic comparison to some level of DBE, and electrical insulation strength measurement can provide a baseline for comparison with other mechanical, chemical, and electrical characterizations that have been utilized. Accelerated aging of two types of ethylene propylene rubber (EPR) insulations from harvested cables was carried out, and the electrical breakdown strength and indenter modulus for both insulations were determined. Results showed that degradation of electrical breakdown strength occurred in only one type of BIW insulation and that this degradation did track with that measured by indenter modulus. The methodology for using Weibull statistics for electrical breakdown strength relative to time to failure is discussed.

Duckworth, Robert↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2021 [Slides]

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While most projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2021, as well as data on "operational" and "withdrawn" projects where those data are available. We find that the amount of new electric capacity in these queues is growing dramatically, with over 1,400 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 90% of which is for zero-carbon resources like solar, wind, and battery storage). Solar (676 GW) and battery storage (~420 GW) are – by far – the fastest growing resources in the queues; combined they accounted for nearly 85% of new capacity entering the queues in 2021. Substantial wind (247 GW) capacity is also seeking interconnection, 31% of which is for offshore projects (77 GW). In total, about 930 GW of zero-carbon generating capacity is currently seeking transmission access, as is 74 GW of natural gas capacity. Hybrids now comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 286 GW of solar hybrids (primarily solar+battery) and 19 GW of wind hybrids are currently active in the queues; nearly half of battery storage in the queues is paired with generation. However, much of this proposed capacity will be withdrawn from the queues and not built. Among a subset of queues for which data are available, only 23% of the projects seeking connection from 2000 to 2016 have subsequently been built. Completion percentages appear to be declining and are even lower for wind and solar than other resources. Additionally, wait times are on the rise: for the regions with available data, the typical duration from connection request to commercial operation increased from ~2.1 years for projects built in 2000-2010 to ~3.7 years for those built in 2011-2021.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2022 [Slides]

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While most projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2022, as well as data on "operational" and "withdrawn" projects where those data are available. We find that the amount of new electric capacity in these queues is growing dramatically, with over 2,000 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 95% of which is for zero-carbon resources like solar, wind, and battery storage). Solar (947 GW) and battery storage (~680 GW) are – by far – the fastest growing resources in the queues; combined they accounted for over 80% of new capacity entering the queues in 2022. Substantial wind (300 GW) capacity is also seeking interconnection, 38% of which is for offshore projects (113 GW). In total, about 1,250 GW of zero-carbon generating capacity is currently seeking transmission access, as is 82 GW of natural gas capacity. Hybrids projects (co-locating multiple generation and/or storage types) comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 457 GW of solar hybrids (primarily solar+battery) and 24 GW of wind hybrids are currently active in the queues; over half of battery storage in the queues is paired with generation. However, much of this proposed capacity will be withdrawn from the queues and not built. Among a subset of queues for which data are available, only 21% of the projects (and 14% of capacity) seeking connection from 2000 to 2017 have been built as of the end of 2022. Additionally, interconnection wait times are on the rise: The typical duration from connection request to commercial operation increased from <2 years for projects built in 2000-2007 to nearly 4 years for those built in 2018-2022 (with a median of 5 years for projects built in 2022).

24 POWER TRANSMISSION AND DISTRIBUTION↗

The 40-kw field test power plant modification and development, phase 2

Progression on the design and development of a 40 KW fuel cell system for on-site installation for providing both thermal and electrical power is reported. Development of the steam reformer fuel processor, power section, inverter, control system, and thermal management and water treatment systems is described.

Source record↗

Power conditioning subsystems for photovoltaic central-station power plants - State-of-the-art and advanced technology

An overview is given of the technical and near-term cost requirements that must be met to develop economically viable power conditioning subsystems (PCS) for large-scale, central photovoltaic power stations. Various commercially available PCS hardware suitable for use in today's central photovoltaic power stations are also surveyed. Federal and industrial activities in the research and development of advanced PCSs that will contribute to the attainment of fully competitive, large-scale photovoltaic power stations are reviewed. The status of the DOE central station PCS program is discussed.

Bulawka, A.↗

A Conceptual Design Study on the Application of Liquid Metal Heat Transfer Technology to the Solar Thermal Power Plant

Alkali metal heat transfer technology was used in the development of conceptual designs for the transport and storage of sensible and latent heat thermal energy in distributed concentrator, solar Stirling power conversion systems at a power level of 15 kWe per unit. Both liquid metal pumped loop and heat pipe thermal transport were considered; system configurations included: (1) an integrated, focal mounted sodium heat pipe solar receiver (HPSR) with latent heat thermal energy storage; (2) a liquid sodium pumped loop with the latent heat storage, Stirling engine-generator, pump and valves located on the back side of the concentrator; and (3) similar pumped loops serving several concentrators with more centralized power conversion and storage. The focus mounted HPSR was most efficient, lightest and lowest in estimated cost. Design confirmation testing indicated satisfactory performance at all angles of inclination of the primary heat pipes to be used in the solar receiver.

Zimmerman, W. F.↗

Comparison of electrochemical and thermal storage for hybrid parabolic dish solar power plants

The economic and operating performance of a parabolic point focus array of solar electricity generators combined with either battery or thermal energy storage are examined. Noting that low-cost, mass-producible power generating units are under development for the point focus of distributed dishes, that Zn-Cl battery tests will begin in 1981 and a 100 kWh Na-S battery in 1983, the state of thermal storage requires acceleration to reach the prototype status of the batteries. Under the assumptions of 10,000 units/yr with an expected 30 yr lifetime, cost comparisons are developed for 10 types of advanced batteries. A 5 MWe plant with full thermal or 80% battery storage discharge when demand occurs in conditions of no insolation is considered, specifically for Fe-Cr redox batteries. A necessity for the doubling of fuel prices from 1980 levels by 1990 is found in order to make the systems with batteries economically competitive.

Steele, H. L.↗

Thermionic topping for central station power plants

This paper describes recent results of the second phase of system analyses on the thermionic topping cycle. A comparison is made among various thermionic heat-exchanger (THX) geometries. Two methods of transferring electric power are considered. In the first, power is provided at relatively high voltages by coupling it out inductively via transformers built into the THX modules. In the second method, converter cells are series-connected within a THX module and external power conditioning is used. The results show that the use of a thermionic topping cycle can result in significant improvements in overall system efficiency.

Britt, E. J.↗

Techno-Economic Analysis of a Concentrating Solar Power Plant Using Redox-Active Metal Oxides as Heat Transfer Fluid and Storage Media

We present results for a one-dimensional quasi-steady-state thermodynamic model developed for a 111.7 MW e concentrating solar power (CSP) system using a redox-active metal oxide as the heat storage media and heat transfer agent integrated with a combined cycle air Brayton power block. In the energy charging and discharging processes, the metal oxide CaAl 0.2 Mn 0.8 O 2.9-δ (CAM28) undergoes a reversible, high temperature redox cycle including an endothermic oxygen-releasing reaction and exothermic oxygen-incorporation reaction. Concentrated solar radiation heats the redox-active oxide particles under partial vacuum to drive the reduction extent deeper for increased energy density at a fixed temperature, thereby increasing storage capacity while limiting the required on sun temperature. Direct counter-current contact of the reduced particles with compressed air from the Brayton compressor releases stored chemical and sensible energy, heating the air to 1,200°C at the turbine inlet while cooling and reoxidizing the particles. The cool oxidized particles recirculate through the solar receiver subsystem for another cycle of heating and reduction (oxygen release). We applied the techno-economic model to 1) size components, 2) examine intraday operation with varying solar insolation, 3) estimate annual performance characteristics over a simulated year, 4) estimate the levelized cost of electricity (LCOE), and 5) perform sensitivity analyses to evaluate factors that affect performance and cost. Simulations use hourly solar radiation data from Barstow, California to assess the performance of a 111.7 MW e system with solar multiples (SMs) varying from 1.2 to 2.4 and storage capacities of 6–14 h. The baseline system with 6 h storage and SM of 1.8 has a capacity factor of 54.2%, an increase from 32.3% capacity factor with no storage, and an average annual energy efficiency of 20.6%. Calculations show a system with an output of 710 GWh e net electricity per year, 12 h storage, and SM of 2.4 to have an installed cost of $329 million, and an LCOE of 5.98 ¢/kWh e . This value meets the U.S. Department of Energy’s SunShot 2020 target of 6.0 ¢/kWh e ( U. S Department of Energy, 2012 ), but falls just shy of the 5.0 ¢/kWh e 2030 CSP target for dispatchable electricity ( U. S Department of Energy, 2017 ). The cost and performance results are minimally sensitive to most design parameters. However, a one-point change in the weighted annual cost of capital from 8 to 7% (better understood as a 12.5% change) translates directly to an 11% decrease (0.66 ¢/kWhe) in the LCOE.

Gorman, Brandon T.↗

Online System ID for Predicting Power Plant Performance Throughout Cycling Operations

This presentation represents a review of the background research conducted by NETL to apply artificial intelligence, i.e. auto-recursive algorithms and data analytics to detect leaks in utility scale boilers and laboratory power systems. The new project being funded by the Advanced Sensors and Controls Program is part of the Field Work Proposal funded in EY21 as Task 53 to demonstrate the application of these techniques on a utility scale power system.

Shadle, Lawrence↗

Modeling receiver flux of commercial power tower concentrating solar power plants using ray tracing: a round-robin comparison of SolTrace, Solstice, and TieSOL

This study presents a multi-stage, cross-validation comparison of three software packages for Monte Carlo ray tracing (MCRT) applied to central tower concentrating solar power (CSP) systems. The three packages evaluated are: (1) SolTrace, an open-source tool developed by the National Renewable Energy Laboratory (NREL); (2) Solstice, an open-source program created by CNRS-PROMES and Meso-Star, with enhancements for CSP applications (called solsticepy) from the Australian National University; and (3) TieSOL, a commercial software developed by Tietronix. This investigation extends previous ray tracing comparisons by incorporating models of multi-facet heliostats within a commercial-scale solar field, taking into account zoned focal lengths and canting configurations. Receiver flux distributions were compared across the tools using a series of case studies, including single-heliostat scenarios, isolated blocking situations, and comprehensive full-field simulations. The case studies were designed to diagnose differences across the models at varying levels of complexity, and to identify and resolve discrepancies as additional parameters were introduced. Key factors examined in the analysis include sun positions, heliostat location, facet and canting focus, and aimpoint strategies. The comparison aims to improve the accuracy and reliability of these tools while providing benchmark cases for validating future optical modeling tools.

14 SOLAR ENERGY↗

Human Factors Considerations in Artificial Intelligence Applications for Nuclear Power Plants

In recent years, there has been a wave of artificial intelligence (AI) technologies that offer to solve problems from shopping habits to mortgage approvals to critical systems operations. The rapidity of the development of these systems has led to both excitement and apprehension about the roles these systems should play in our modern societies. Furthermore, this paper focuses on the critical infrastructure industry, in general, and nuclear power generation, in particular, and seeks to scrutinize how we can leverage these novel technologies in human-centered ways to maintain or enhance the established high levels of reliability and resilience in these industries. First, we discuss the broader aspects of cognitive systems and activities that are critical to understanding the human-AI space. Then we explore different approaches to explainability in AI and the notions of trust. We then move on to discuss several human factors concepts and methods and how they can support the design of human-AI teams. We then explore recent research related to nuclear power that has been undertaken and evaluate the current industry and regulatory landscapes. Finally, we discuss identified research gaps and recommendations for solving these for the critical infrastructure space.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evolution of integrated panel structural design and interfaces for PV power plants

The evolution of integrated photovoltaic (PV) panel design at ARCO Solar is discussed. Historically, framed PV modules of about 1 x 4-ft size were individually mounted in the field on fixed support structures and interconnected electrically with cables to build higher-power arrays. When ARCO Solar saw the opportunity in 1982 to marry its PV modules with state-of-the-art heliostat trackers developed by ARCO Power Systems, it became obvious that mounting individual modules was impractical. For this project, the framed modules were factory-assembled into panels and interconnected with cables before being mounted on the trackers. Since then, ARCO Solar made considerable progress and gained substantial experience in the design and fabrication of large PV panels. Constraints and criteria considered in these design activities included static and dynamic loads; assembly and transportation equipment and logistics, structural and electrical interfaces, and safety and grounding concerns.

Arnett, J. C.↗

NASA objectives for improved solar power plants

The present work describes the principal goals for the main effort of NASA's research and development of solar photovoltaic cells and arrays. These are (1) to reduce array costs from $270/watt to $90/watt (no change in volume) or to $41/watt (high volume production), (2) raise power density from 66 watts/kg to 110 watts/kg, and (3) minimize dynamic interaction problems. The first two goals can be accomplished by increased cell efficiency, reduced cell thickness, the development of a multiple ribbon growth process, and automation of cell production. To minimize dynamic interaction between array and spacecraft, module flexibility will be increased.

Cohn, E. M.↗

Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant. Conceptual Design Engineering Report (CDER) supplement. Magnet system special investigations

The results of magnet system special investigations listed below are summarized: 4 Tesla Magnet Alternate Design Study; 6 Tesla Magnet Manufacturability Study. The conceptual design for a 4 Tesla superconducting magnet system for use with an alternate (supersonic) ETF power train is described, and estimated schedule and cost are identified. The magnet design is scaled from the ETF 6 T Tesla design. Results of a manufacturability study and a revised schedule and cost estimate for the ETF 6 T magnet are reported. Both investigations are extensions of the conceptual design of a 6 T magnet system performed earlier as a part of the overall MED-ETF conceptual design described in Conceptual Design Engineering Report (CDER) Vol. V, System Design Description (SDD) 503 dated September, 1981, DOE/NASA/0224-1; NASA CR-165/52.

Source record↗

Solar Sea Power Plants (SSPP): A critical review and survey

An overview of technical and economic matters relating to the eventual success or failure of the SSPP concept is presented, with emphasis on the pollution and energy problems which the SSPP would serve to eliminate. Factors discussed include cost, mariculture possibilities, siting, legal limitations, design materials, mooring and anchoring, and the human element involved. Several alternative power systems are considered for incorporation into SSPP design, such as Nitinol power, Claude cycle, and closed cycle engine systems.

Strauss, A. M.↗