Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

High Performance Magnetic Bearings for Aero Applications

Several previous annual reports were written and numerous papers published on the topics for this grant. That work is not repeated here in this final report. Only the work completed in the final year of the grant is presented in this final report. This final year effort concentrated on power loss measurements in magnetic bearing rotors. The effect of rotor power losses in magnetic bearings are very important for many applications. In some cases, these losses must be minimized to maximize the length of time the rotating machine can operate on a fixed energy or power supply. Examples include aircraft gas turbine engines, space devices, or energy storage flywheels. In other applications, the heating caused by the magnetic bearing must be removed. Excessive heating can be a significant problem in machines as diverse as large compressors, electric motors, textile spindles, and artificial heart pumps.

Allaire, P. E.↗

Measuring Effects Of Lightning On Power And Telephone Lines

Spherical antenna senses both horizontal and vertical fields simultaneously. Measures "fast" components of electric field used in conjunction with other equipment, including antenna measuring "slow" vertical component of electric field; microphone that senses thunder; cameras making visual records, which locate lightning; magnetic-field sensor; optical sensors; and instruments measuring speed and direction of wind.

Jafferis, William↗

Voltage Stability Assessment Using Synchronized Phasor Measurements Applied to the Argentine Power System

This paper presents tests of different methods for long term voltage stability analysis based on PMU measurements. In particular, Thevenin Impedance Matching and sensitivity calculation are studied. Simulation are performed in a modified Argentine power system model, to include the main components for studying long term voltage stability. Disconnection of a large Thermal Generating Station causing long-term voltage instability at Gran Buenos Aires Area is studied. It is shown that computing the apparent impedance of Thevenin equivalent at load bus from measurements taken at a single time but at various locations of the transmission corridor produce a significant reduction of the estimation error produce when only local measurements are used. Voltage Stability analysis is performed using a reduced power system model where changing parameters are fully computed through PMU data at each time. Over this reduced power system model, voltage stability index and sensibility calculations are performed.

Gill-Estebez, Pablo↗

An Analysis of the Effects of RFID Tags on Narrowband Navigation and Communication Receivers

The simulated effects of the Radio Frequency Identification (RFID) tag emissions on ILS Localizer and ILS Glide Slope functions match the analytical models developed in support of DO-294B provided that the measured peak power levels are adjusted for 1) peak-to-average power ratio, 2) effective duty cycle, and 3) spectrum analyzer measurement bandwidth. When these adjustments are made, simulated and theoretical results are in extraordinarily good agreement. The relationships hold over a large range of potential interference-to-desired signal power ratios, provided that the adjusted interference power is significantly higher than the sum of the receiver noise floor and the noise-like contributions of all other interference sources. When the duty-factor adjusted power spectral densities are applied in the evaluation process described in Section 6 of DO-294B, most narrowband guidance and communications radios performance parameters are unaffected by moderate levels of RFID interference. Specific conclusions and recommendations are provided.

LaBerge, E. F. Charles↗

H-ATLAS: THE COSMIC ABUNDANCE OF DUST FROM THE FAR-INFRARED BACKGROUND POWER SPECTRUM

We present a measurement of the angular power spectrum of the cosmic far-infrared background (CFIRB) anisotropies in one of the extragalactic fields of the Herschel Astrophysical Terahertz Large Area Survey at 250, 350, and 500 {mu}m bands. Consistent with recent measurements of the CFIRB power spectrum in Herschel-SPIRE maps, we confirm the existence of a clear one-halo term of galaxy clustering on arcminute angular scales with large-scale two-halo term of clustering at 30 arcmin to angular scales of a few degrees. The power spectrum at the largest angular scales, especially at 250 {mu}m, is contaminated by the Galactic cirrus. The angular power spectrum is modeled using a conditional luminosity function approach to describe the spatial distribution of unresolved galaxies that make up the bulk of the CFIRB. Integrating over the dusty galaxy population responsible for the background anisotropies, we find that the cosmic abundance of dust, relative to the critical density, to be between {Omega}{sub dust} = 10{sup -6} and 8 Multiplication-Sign 10{sup -6} in the redshift range z {approx} 0-3. This dust abundance is consistent with estimates of the dust content in the universe using quasar reddening and magnification measurements in the Sloan Digital Sky Survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Wide-Area Measurement-Based Modal Decoupling for Power System Oscillation Damping

Inter-area oscillation modes usually fall within the same frequency range of 0.1 to 1.0 Hz; thus, power oscillation damping (POD) control methods should avoid unnecessary excitation of weakly damped modes. This paper presents a decoupled control strategy to damp inter-area oscillations in the power grid. Pure oscillation mode signals are extracted from wide-area measurements and used as feedback input for POD actuators such as power system stabilizers or high-voltage direct current transmission. The decoupled control strategy is able to increase the damping of the concerned oscillation modes without deteriorating others. This proposed strategy could be implemented independently, or serve as a complement and work along with conventional POD controllers to damp concerned inter-area modes. The proposed method has been tested on a modied MinniWECC system. Extensive results indicate that inter-area oscillations can be successfully and precisely damped using the proposed decoupled strategy.

Fan, Rui↗

Estimation of inflation parameters for Perturbed Power Law model using recent CMB measurements

Cosmic Microwave Background (CMB) is an important probe for understanding the inflationary era of the Universe. We consider the Perturbed Power Law (PPL) model of inflation which is a soft deviation from Power Law (PL) inflationary model. This model captures the effect of higher order derivative of Hubble parameter during inflation, which in turn leads to a non-zero effective mass m{sub eff} for the inflaton field. The higher order derivatives of Hubble parameter at leading order sources constant difference in the spectral index for scalar and tensor perturbation going beyond PL model of inflation. PPL model have two observable independent parameters, namely spectral index for tensor perturbation ν{sub t} and change in spectral index for scalar perturbation ν{sub st} to explain the observed features in the scalar and tensor power spectrum of perturbation. From the recent measurements of CMB power spectra by WMAP, Planck and BICEP-2 for temperature and polarization, we estimate the feasibility of PPL model with standard ΛCDM model. Although BICEP-2 claimed a detection of r=0.2, estimates of dust contamination provided by Planck have left open the possibility that only upper bound on r will be expected in a joint analysis. As a result we consider different upper bounds on the value of r and show that PPL model can explain a lower value of tensor to scalar ratio (r<0.1 or r<0.01) for a scalar spectral index of n{sub s}=0.96 by having a non-zero value of effective mass of the inflaton field m{sup 2}{sub eff}/H{sup 2}. The analysis with WP + Planck likelihood shows a non-zero detection of m{sup 2}{sub eff}/H{sup 2} with 5.7 σ and 8.1 σ respectively for r<0.1 and r<0.01. Whereas, with BICEP-2 likelihood m{sup 2}{sub eff}/H{sup 2} = −0.0237 ± 0.0135 which is consistent with zero.

79 ASTRONOMY AND ASTROPHYSICS↗

An Innovative Software Tool Suite for Power Plant Model Validation and Parameter Calibration using PMU Measurements

Maintaining good quality of power plant stability models is of critical importance to ensure the secure and economic operation and planning of today’s power grid with its increasing stochastic and dynamic behavior. According to North American Electric Reliability (NERC) standards, all generators in North America with capacities larger than 10 MVA are required to validate their models every five years. Validation is quite costly and can significantly affect the revenue of generator owners, because the traditional staged testing requires generators to be taken offline. Over the past few years, validating and calibrating parameters using online measurements including phasor measurement units (PMUs) and digital fault recorders (DFRs) has been proven to be a cost-effective approach. In this paper, an innovative open-source tool suite is presented for validating power plant models using PPMV tool, identifying bad parameters with trajectory sensitivity analysis, and finally calibrating parameters using an ensemble Kalman filter (EnKF) based algorithm. The architectural design and the detailed procedures to run the tool suite are presented, with results of test on a realistic hydro power plant using PMU measurements for 12 different events. The calibrated parameters of machine, exciter, governor and PSS models demonstrate much better performance than the original models for all the events and show the robustness of the proposed calibration algorithm.

Li, Yuanyuan↗

Performance Characteristics of “Spotter,” a Newly Developed Real-Time Wave Measurement Buoy

The Spotter is a low-cost, real-time, solar-powered wave measurement buoy that was recently developed by Spoondrift Technologies, Inc. (Spoondrift). To evaluate the data quality of the Spotter device, we performed a series of validation experiments that included comparisons between Spotter-derived motions and prescribed wave motions (monochromatic and random waves) on a custom-built, motion-controlled validation stand and simultaneous in-water measurements using a conventional wave measurement buoy, the Datawell DWR-G4 (Datawell). Spotter evaluations included time-domain validation (i.e., wave by wave) and comparisons of wave spectra, directional moments, and bulk statistical parameters such as significant wave height, peak period, mean wave direction, and directional spread. Spotter wave measurements show excellent fidelity and lend a high degree of confidence in data quality. Overall, Spotter-derived bulk statistical parameters were within 10% of respective Datawell-derived quantities. The Spotter’s low cost and compact form factor enabled unique field deployments of multiple wave measurement buoys for direct measurements of wave characteristics such as ocean wave decorrelation length scales, wave speed, and directional spread. Wave decorrelation lengths were found to be inversely proportional to the width of the spectrum, and wave speeds compared well against linear wave theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision measurements of EFT parameters and BAO peak shifts for the Lyman- α forest

We present precision measurements of the bias parameters of the one-loop power spectrum model of the Lyman- α (Ly- α ) forest, derived within the effective field theory (EFT) of large-scale structure. We fit our model to the three-dimensional flux power spectrum measured from the ACCEL 2 hydrodynamic simulations. The EFT model fits the data with an accuracy of below 2% up to k = 2 h Mpc − 1 . Further, we analytically derive how nonlinearities in the three-dimensional clustering of the Ly- α forest introduce biases in measurements of the baryon acoustic oscillations (BAOs) scaling parameters in radial and transverse directions. From our EFT parameter measurements, we obtain a theoretical error budget of Δ α ∥ = − 0.2 % ( Δ α ⊥ = − 0.3 % ) for the radial (transverse) parameters at redshift z = 2.0 . This corresponds to a shift of − 0.3 % (0.1%) for the isotropic (anisotropic) distance measurements. We provide an estimate for the shift of the BAO peak for Ly- α -quasar cross-correlation measurements assuming analytical and simulation-based scaling relations for the nonlinear quasar bias parameters resulting in a shift of − 0.2 % ( − 0.1 % ) for the radial (transverse) dilation parameters, respectively. This analysis emphasizes the robustness of Ly- α forest BAO measurements to the theory modeling. We provide informative priors and an error budget for measuring the BAO feature—a key science driver of the currently observing Dark Energy Spectroscopic Instrument (DESI). Our work paves the way for full-shape cosmological analyses of Ly- α forest data from DESI and upcoming surveys such as the Prime Focus Spectrograph, WEAVE-QSO, and 4MOST. Published by the American Physical Society 2025

de Belsunce, Roger (ORCID:0000000336604028)↗

Composite Power System Reliability with Renewables and Customer Flexibility

Composite Power System Reliability is defined as the computational procedure that quantifies the probability that the power system will perform the function of delivering electric power to customers adequately, on a continuous basis and with an acceptable quality. This definition leaves many details undefined and exemplifies the ambiguity in reliability analysis. The increasing deployment of wind and PV creates additional uncertainties that make reliability analysis a rather complex issue. Because of increased uncertainty the need for composite reliability analysis and utilization of results in power system planning is critical. New approaches are emerging for dealing with these problems from the operational point of view, including demand response programs, tapping on customer and distributed resource flexibility and new control approaches. The key question to be addressed is: how the new operational paradigms affect composite power system reliability. Here, this paper presents the ongoing work of the IEEE Composite System Reliability Task Force of the IEEE PES Reliability, Risk, Probability Application (RRPA) Subcommittee.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of the quantum efficiency of optical heterodyne detectors

The frequency response and quantum efficiency of optical photodetectors for heterodyne receivers is investigated. The measurements utilized two spectral lines from the output of two lasers as input to the photodetectors. These lines are easily measurable in power and frequency and hence serve as known inputs. By measuring the output current of the photodetector the quantum efficiency is determined as a function of frequency separation between the two input signals. An investigation of the theoretical basis and accuracy of this type of measurement relative to similar measurements utilizing risetime is undertaken. A theoretical study of the heterodyne process in photodetectors based on semiconductor physics is included so that higher bandwidth detectors may be designed. All measurements are made on commercially available detectors and manufacturers' specifications for normal photodetector operation are compared to the measured heterodyne characteristics.

Batchman, T. E.↗

A small, single stage orifice pulse tube cryocooler demonstration

This final report summarizes and presents the analytical and experimental progress in the present effort. The principal objective of this effort was the demonstration of a 0.25 Watt, 80 Kelvin orifice pulse tube refrigerator. The experimental apparatus is described. The design of a partially optimized pulse tube refrigerator is included. The refrigerator demonstrates an ultimate temperature of 77 K, has a projected cooling power of 0.18 Watts at 80 K, and has a measured cooling power of 1 Watt at 97 K, with an electrical efficiency of 250 Watts/Watt, much better than previous pulse tube refrigerators. A model of the pulse tube refrigerator that provides estimates of pressure ratio and mass flow within the pulse tube refrigerator, based on component physical characteristics is included. A model of a pulse tube operation based on generalized analysis which is adequate to support local optimization of existing designs is included. A model of regenerator performance based on an analogy to counterflow heat exchangers is included.

Hendricks, John B.↗

Common Mode Conducted Emissions

This presentation provides an overview of common mode conducted emissions (CMCE) measurements on power and signal cables. The presentation focuses on how such measurements directly apply to electromagnetic compatibility at the system level and provides a discussion of different techniques for performing them correctly and accurately.

Current↗

Power And Current Bounds For Two Similar Loads

We examine the question of how to obtain bounding power (or current) for two similar loads with an unknown source circuit, but measurements of power (or current) for one load as well as models and measurements of both load impedances.

42 ENGINEERING↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Optimal Design of Megahertz $LLC$ Converter for 48-V Bus Converter Application

Intermediate bus architecture employing 48-V bus converters is widely used in power supply applications. With the rapid increase of demanded power by these loads, higher efficiency and power density are driving better performance power management solutions. In this article, a Gallium Nitride (GaN) based design of a two-stage solution is proposed. The first stage is a multi-phase Buck for regulation. The second stage is an LLC converter with a fixed switching frequency for isolation. The detailed design and optimization of the LLC converter are studied. To achieve high power density and high efficiency, the transformer design becomes critical at megahertz frequency. The matrix transformer concept is applied and a merged winding structure is used for flux cancellation, which effectively reduces the ac winding losses. A novel primary termination and via structure is proposed, resulting in a great loss reduction. In addition, to study the current sharing of parallel winding layers, a 1-D analytic model is proposed, and a symmetrical winding layer scheme is used to balance the current distribution. Finally, the prototype for the two-stage bus converter is developed, with a peak efficiency of 96% and a power density of 615 W/in 3 .

42 ENGINEERING↗

Near- and far scrape-off layer transport studies in detached, small-ELM ASDEX Upgrade discharges by means of EMC3-EIRENE

We compare various diagnostics characterizing an ASDEX Upgrade upper single-null discharge to EMC3-EIRENE simulations now including volumetric recombination and main chamber plasma-wall interaction but not yet drifts. The discharge is in a small-ELM regime and is approaching detachment due to a density ramp and nitrogen seeding. Time/ELM averaged upstream density, electron and ion temperature measurements as well as downstream ion saturation current, electron temperature and power flux measurements match the simulation within the error bars before and after reaching detachment, qualifying the code for this regime. Although the Ion Cyclotron Resonance Heating (ICRH) antenna limiters are 35 mm away from the separatrix, i.e. ten times the typical near-SOL power fall-off length $\lambda^{near}_q\ =\ $3.8 mm, they receive power fluxes of several hundreds of kW exceeding the ones to the outer target in the detached phase and strongly contribute to the particle fueling. This is explained by a substantially larger far-SOL power fall-off length $\lambda^{far}_q\ =\ $25 mm possibly caused by the small ELMs in the detached phase and the occurrence of a density shoulder.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗