Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons

In this paper, we describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Drag-Free Control and Drag Force Recovery of Small Satellites

Drag-free satellites provide autonomous precision orbit determination, accurately map the static and time varying components of Earth's mass distribution, aid in our understanding of the fundamental force of gravity, and will ultimately open up a new window to our universe through the detection and observation of gravitational waves. At the heart of this technology is a gravitational reference sensor, which (a) contains and shields a free-floating proof mass from all non-gravitational forces, and (b) precisely measures the position of the test mass inside the sensor. Thus, both test mass and spacecraft follow a pure geodesic in spacetime. By tracking the position of a low Earth orbiting drag-free satellite we can directly determine the detailed shape of geodesics and through analysis, the higher order harmonics of the Earths geopotential. This paper explores two different drag-free control systems on small satellites. The first drag-free control system is a continuously compensated single thruster 3-unit CubeSat with a suspension-free spherical proof-mass. A feedback control system commands the thruster and Attitude and Determination Control System to fly the tender spacecraft with respect to the test mass. The spheres position is sensed with a LED-based differential optical shadow sensor, its electric charge controlled by photoemission using UV LEDs, and the spacecraft position is maintained with respect to the sphere using an ion electrospray propulsion system. This configuration is the most fuel-efficient drag-free system possible today. The second drag-free control system is an electro-statically suspended cubical proof-mass that is operated with a low duty cycle, limiting suspension force noise over brief, known time intervals on a small GRACE-II -like satellite. The readout is performed using a laser interferometer, which is immune to the dynamic range limitations of voltage references. This system eliminates the need for a thruster, enabling drag-free control systems for passive satellites. In both cases, the test mass position, GPS tracking data, and commanded actuation, either thrust or suspension system, can be analyzed to estimate the 3-axis drag forces acting on the satellite. The data produces the most precise maps of upper atmospheric drag forces and with additional information, detailed models that describe the dynamics of the upper atmosphere and its impact on all satellites that orbit the Earth. This paper highlights the history, applications, design, laboratory technology development and highly detailed simulation results of each control system.

Small Satellites↗

Fast-charging lithium-ion batteries: Synergy of carbon nanotubes and laser ablation

Advancing lithium-ion battery (LiB) technology to achieve 10–15-min extreme fast charging (XFC) while maintaining high energy density and longevity poses a significant challenge. Addressing Li-plating is crucial, as it depletes useable Li, causing deterioration and safety issues. Here, this study explores a holistic approach incorporating Single-Wall Carbon Nanotubes (SWCNTs) and Laser Ablation (LA) to mitigate Li-plating while maintaining high charge acceptance under 10–15-min XFC. SWCNTs enhance the electrical conductivity and mechanical integrity of the positive electrode (PE), reducing overall cell overpotential at high charging rates. Concurrently, LA is applied to negative electrodes (NE) to reduce tortuosity of ion-diffusion pathways and increase surface wettability, improving Li-ion transport. Combining SWCNTs in the PE and LA on the NE, our experimental findings demonstrate a significant reduction in Li-plating and maintained high charge acceptance of ~84.33 % after 800 5C (12 min) charge cycles for cells having PE with ~3.3 mAh cm –2 and NE with 3.9 mAh cm –2 loadings. This study highlights the potential of combining SWCNTs and LA to address Li-plating in LiBs and opens new avenues for designing battery systems capable of achieving 10–15-min XFC.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extreme Transverse Magnetoresistance in TiZn 16

Extreme magnetoresistance (XMR) is a phenomenon characterized by an increase in resistance by factors of 10 4 –10 7 % when a magnetic field is applied. This phenomenon is found in a number of semimetals such as WTe 2 , PtSn 4 , Cd 3 As 2 , and LaSb. The origin of XMR is still hotly debated, possibly with different materials having different (or multiple) explanations. Extreme transverse magnetoresistance of up to 8000% at 14 T and 1.8 K is measured in TiZn 16 , a semimetal with a multitude of bands crossing the Fermi energy, akin to PtSn 4 . The magnetoresistance is suppressed when the magnetic field is rotated to be parallel to the applied current, similar to PtSn 4 and PdSn 4 . The resistance of TiZn 16 follows Kohler's rule, but displays different behavior under an applied transverse field and under a longitudinal magnetic field, suggesting distinct electrical phases. Also present are Shubnikov-de Haas and de Haas-van Alphen oscillations with a transverse magnetic field up to 43 T, showing that despite an insulator-like temperature-resistance curve, charge carriers are still present. This positions TiZn 16 as an interesting addition to the investigation of XMR materials as a multi-band metal with complex Fermi surface geometries.

extreme magnetoresistance↗

Duality and supersymmetry constraints on the weak gravity conjecture

Positivity bounds coming from consistency of UV scattering amplitudes are not always sufficient to prove the weak gravity conjecture for theories beyond Einstein-Maxwell. Additional ingredients about the UV may be necessary to exclude those regions of parameter space which are naïvely in conflict with the predictions of the weak gravity conjecture. In this paper we explore the consequences of imposing additional symmetries inherited from the UV theory on higher-derivative operators for Einstein-Maxwell-dilaton-axion theory. Using black hole thermodynamics, for a preserved SL(2, $\mathbb{R}$) symmetry we find that the weak gravity conjecture then does follow from positivity bounds. For a preserved O(d, d; $\mathbb{R}$) symmetry we find a simple condition on the two Wilson coefficients which ensures the positivity of corrections to the charge-to-mass ratio and that follows from the null energy condition alone. We find that imposing supersymmetry on top of either of these symmetries gives corrections which vanish identically, as expected for BPS states.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CsI calorimeter for the J-PARC KOTO experiment

An electromagnetic calorimeter made of undoped CsI crystals is used in the J-PARC KOTO experiment to search for new physics beyond the standard model with the KL → π 0 νν¯ decay. The calorimeter is designed to operate in vacuum of 0.1 Pa and in a high-rate environment where the counting rate due to KL decays is O(100) kHz. A special method to calibrate the calorimeter during the data taking without using a tracking system for charged particles is reported. The energy, position, and timing resolutions of the calorimeter were evaluated in several beam tests, and the resolutions satisfy the required performance. Finally, the energy resolution with the total energy E is 0.66 ⊕ 1.81/ √ E[GeV]% in the inner region of the calorimeter.

47 OTHER INSTRUMENTATION↗

In situ electrochemical recomposition of decomposed redox-active species in aqueous organic flow batteries

Aqueous organic redox flow batteries (AORFBs) offer a safe and potentially inexpensive solution to the problem of storing massive amounts of electricity produced from intermittent renewables. However, molecular decomposition is the major barrier preventing AORFBs from being commercialized. Structural modifications can improve molecular stability at the expense of increased synthetic cost and molecular weight. Utilizing 2,6-dihydroxy-anthraquinone (DHAQ), without further structural modification, we demonstrate that electrochemical regeneration could be a viable route to achieve low-cost, long-lifetime AORFBs. In situ (online) NMR and EPR and complementary electrochemical analyses reveal that decomposition compounds i.e., 2,6-dihydroxy-anthrone (DHA) and its tautomer, 2,6-dihydroxy-anthranol (DHAL), can be converted back to DHAQ in two steps: first DHA(L) 2- are oxidized to the dimer (DHA) 2 4- at - 0.32 V vs. SHE by one-electron transfer; subsequently, the (DHA) 2 4- is oxidized to DHAQ 2- at +0.57 V vs. SHE by three-electron transfer. Electrochemical regeneration rejuvenates not only DHAQ 2- , but also the positive electrolyte – rebalancing the states of charge of both electrolytes without introducing extra ions. We demonstrate the repeated capacity recovery with DHAQ | potassium ferro-/ferricyanide flow battery in basic conditions, and show the approach is also effective for anthraquinone-2,7-disulfonate in acid. Electrochemical regeneration strategies may extend the useful lifetime of many water-soluble organic molecules with anthraquinone core structures in electrochemical cells.

25 ENERGY STORAGE↗

Sheath formation around a dielectric droplet in a He atmospheric pressure plasma

Interactions at the interface between atmospheric pressure plasmas and liquids are being investigated to address applications ranging from nanoparticle synthesis to decontamination and fertilizer production. Furthermore, many of these applications involve activation of droplets wherein the droplet is fully immersed in the plasma and synergistically interacts with the plasma. To better understand these interactions, two-dimensional modeling of radio frequency (RF) glow discharges at atmospheric pressure operated in He with an embedded lossy dielectric droplet (tens of microns in size) was performed. The properties of the sheath that forms around the droplet were investigated over the RF cycle. The electric field in the bulk plasma polarizes the dielectric droplet while the electron drift in the external electric field is shadowed by the droplet. The interaction between the bulk and sheath electric fields produces a maximum in E/N (electric field/gas number density) at the equator on one side of the droplet where the bulk and sheath fields are aligned in the same direction and a minimum along the opposite equator. Due to resistive heating, the electron temperature T e is maximum 45° above and below the equator of the droplet where power deposition per electron is the highest. Although the droplet is, on the average, negatively charged, the charge density on the droplet is positive on the poles and negative on the equator, as the electron motion is primarily due to diffusion at the poles but due to drift at the equator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design, development, and flight of a spacecraft charging sounding rocket payload

Results of the flight of the spacecraft charging sounding rocket payload are given. The payload was designed to create charging by the emission of both positive ions and electrons. The relationship between environmental parameters and changes in vehicle potential during periods of emission was also studied.

Cohen, H. A.↗

Fiber optics for astronomical spectroscopy - The Medusa Spectrograph

An instrument has been built to obtain simultaneous spectra of 32 objects in the field of view of the Steward Observatory 2.3 m telescope. Short lengths of optical fiber are used to bring light from galaxy images at the focus of the telescope into a line at the spectrograph slit. This multi-fiber aperture plate instrument has been dubbed the Medusa Spectrograph. The Medusa is now producing spectra of about 100 galaxies per clear night. An optimized version of the instrument called the MX Spectrometer is being constructed to record spectra at a higher rate. This new instrument will have remotely positioned fibers under computer control. A Charge Coupled Device will be used as the spectrograph detector to allow sky subtraction, give increased dynamic range and provide more accurate wavelength calibration. Transmission characteristics of some commercial fibers are discussed, and the microlens optics used to match the telescope and the spectrograph to the fibers to avoid focal ratio degradation are described.

Hill, J. M.↗

Search for heavy antinuclei in the cosmic radiation

The existence of significant amounts of antimatter in the Universe is demonstrated through cosmic radiation. The data from the Danish-French Cosmic Ray Spectrometer on the HEAO-3 satellite offers an opportunity to search for heavy antinuclei, since all the relevant parameters (charge, velocity, arrival direction, and satellite position at the time of arrival) are measured for each recorded nucleus. Using the 22676 positive only events in the data seletion corresponding to L 1.5 as a measure of our exposure factor to heavy antinuclei and noting that no corresponding antinuclei were found, an upper limit (95% confidence) is given to the ratio of antinuclei to nuclei as 1.4 x .0001 for particles with Z 9. The upper limit resulting from this work is compared with previous results of searches for heavy antimatter in the cosmic radiation. It is seen that, if one regards only antiparticles heavier than fluorine, then the present result represents a reduced upper limit over previous data. When taken together, all the available experiment data now push the upper limit for the ratio of antiparticles to particles well below .0001.

Lund, N.↗

Statistically determined nickel cadmium performance relationships

A statistical analysis was performed on sealed nickel cadmium cell manufacturing data and cell matching data. The cells subjected to the analysis were 30 Ah sealed Ni/Cd cells, made by General Electric. A total of 213 data parameters was investigated, including such information as plate thickness, amount of electrolyte added, weight of active material, positive and negative capacity, and charge-discharge behavior. Statistical analyses were made to determine possible correlations between test events. The data show many departures from normal distribution. Product consistency from one lot to another is an important attribute for aerospace applications. It is clear from these examples that there are some significant differences between lots. Statistical analyses are seen to be an excellent way to spot those differences. Also, it is now proven beyond doubt that battery testing is one of the leading causes of statistics.

Gross, Sidney↗

Discharge transient coupling in large space power systems

Experiments have shown that plasma environments can induce discharges in solar arrays. These plasmas simulate the environments found in low earth orbits where current plans call for operation of very large power systems. The discharges could be large enough to couple into the power system and possibly disrupt operations. Here, the general concepts of the discharge mechanism and the techniques of coupling are discussed. Data from both ground and flight experiments are reviewed to obtain an expected basis for the interactions. These concepts were applied to the Space Station solar array and distribution system as an example of the large space power system. The effect of discharges was found to be a function of the discharge site. For most sites in the array discharges would not seriously impact performance. One location at the negative end of the array was identified as a position where discharges could couple to charge stored in system capacitors. This latter case could impact performance.

Stevens, N. John↗

Computer modeling of current collection by the CHARGE-2 mother payload

The three-dimensional computer codes NASCAP/LEO and POLAR have been used to calculate current collection by the mother payload of the CHARGE-2 rocket under conditions of positive and negative potential up to several hundred volts. For negative bias (ion collection), the calculations lie about 25 percent above the data, indicating that the ions were less dense, colder, or heavier than the input parameters. For positive bias (electron collection), NASCAP/LEO and POLAR calculations show similar agreement with the measurements at the highest altitudes. This agreement indicates that the current is classically magnetically limited, even during electron beam emission. However, the calculated values fall well below the data at lower altitudes. It is suggested that beam-plasma-neutral interactions are responsible for the high values of collected current at altitudes below 240 km.

Mandell, M. J.↗

Reinforced Positive Filler Paste For Lead/Acid Batteries

Lead-coated glass fibers extend battery life. Mixture of lead-coated glass fibers and positive paste form pellets of active material between grid wires of positive battery electrode. Fibers contribute to charge capacity, electrical conductivity, and mechanical stability of electrode.

Edwards, Dean B.↗

Pulsed, gridded electron reversal ionizer

The design and performance of a new-type source of negative ions is presented. This device retains the idea of the so-called reversal electron attachment detector to produce low-energy electrons by reversing electron trajectories at an electrode. Electrons are produced in the present device by several ribbon filaments that surround a cylindrical wire grid. They are accelerated through the grid, then decelerated to zero or near-zero velocity at the surface of a tube. The tube (anode) is perforated with small holes through which effuse the target molecules. Electrons attach to form either parent and/or fragment negative ions. Attachment takes place at a location above the anode corresponding to a match between the electron energy and the attachment resonance energy. Negative ions are pulsed out of the attachment region and focused onto the entrance plane of a quadrupole mass selector. Electron and ion trajectory calculations are presented and the performance illustrated with six molecules having attachment resonances in the range 0.0-2.2 eV. The detection sensitivity is below 1 part-per-trillion, with a calculated conversion rate of 1.3 percent. Signal nonlinearity is discussed in terms of ion space-charge effects. The device also produces positive ions, and an analogous treatment may be carried through to characterize its performance in this mode.

Boumsellek, S.↗

Effect of KOH concentration and anions on the performance of Ni-H2 battery positive plate

The capacity and voltage behavior of electrochemically impregnated sintered nickel positive plates was examined by galavanostatic charging; and discharging in a flooded electrolyte cell. Three different concentrations of KOH (40 percent, 31 percent, and 26 percent) and 31 percent KOH containing dissolved nitrate, sulfate or silicate were investigated. The end of charge voltage at C/10 charge and at 10 C showed the following order: 40 percent KOH is greater than 31 percent KOH alone and in the presence of the anions greater than 26 percent KOE. The middischarge voltage at C/2 discharge was higher in 26 percent KOH, almost the same for 31 percent KOH with and without the added contaminants and much lower for 40 percent KOH. The plate capacity was marginally affected by cycling in all cases except for 40 percent KOH where the capacity declined after 1000 cycles at 80 percent DOD. At the end of cycling the plate tested in the presence of sulfate and silicate experienced measurable weight loss as a result of active material extrusion. Cyclic voltammetry of miniature electrodes in 31 percent KOH showed that the second oxidation peak that corresponds to the formation of a different phase of oxidized Ni has a lower peak current at -5 C compared to 25 C and oxygen evolution occurs a higher potential at -5 C. The reduction peak (discharge reaction) is more polarized at 25 C compared to -5 C. The presence of silicate alters the potentials only marginally. The implications of these results in plate treatment and low temperature operation are discussed.

Vaidyanathan, H.↗