Electrostatic equilibria of non-neutral plasmas confined in a Penning trap with axially varying magnetic field

A procedure for computing the electrostatic equilibria of non-neutral plasmas in a Penning trap with a nonuniform magnetic field by solving Poisson's equation using an iterative method is described. Plasma equilibria in a model Penning trap with high and low field regions are computed. The plasma is assumed to follow the Boltzmann density distribution along magnetic field lines. Correspondence with previous investigations examining similar configurations analytically and using particle-in-cell simulations is found. The relationship between the plasma density in low and high field regions is examined for various plasma temperatures, densities, magnetic mirror ratios, and plasma and electrode radii. An analytical description of the radial density profile in the high field region is developed and compared with the computed equilibria. A concept is described for cooling a positron plasma with laser-cooled ions trapped axially within a high magnetic field region, while antiprotons are trapped axially separated from the laser-cooled ions within a low field region, and the positron plasma extends to both regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulation of transonic separated flows over low-aspect ratio wings

Transonic flow fields about a low-aspect-ratio advanced technology wing have been computed using a viscous/inviscid zonal approach. The flow field near the wing where viscous effects are important was solved using the 'Reynolds-Averaged Navier-Stokes Equations' in 'thin-layer' form. The Euler equations were used to determine the flow field in regions away from the wing where viscous effects are insignificant. A zonal grid using an H-H topology was generated around the wing by first solving a set of Poisson's equations for the global grid. This grid was then subdivided into separate zones of viscous or inviscid flow as suggested by the flow physics. A series of flow cases were computed and compared with corresponding sets of experimental data. All cases showed good agreement with experiment in terms of the pressure field. Also, a good correlation between computed separated surface flow and experimental oil flow was obtained.

Kaynak, U.↗

Pore-Scale Transport Effects in Electrochemical CO 2 Reduction on Gold via Coupled Microkinetic-Transport Modeling

A pore-resolved modeling framework is developed to quantify how pore-scale transport affects the intrinsic microkinetics of CO 2 -to-CO on Au. A DFT-informed microkinetic model is coupled self-consistently to a Generalized-Modified Poisson–Nernst–Planck (GMPNP) transport description in a single, electrolyte-filled cylindrical pore, allowing local concentrations and potential to feed back into site-specific reaction rates. FIB-SEM is used to determine pore sizes within realistic electrode materials. Across pore diameters, d p = 10–6000 nm, the surface-averaged CO 2 reduction rate is systematically reduced relative to the ideal microkinetic baseline where mass transport is not accounted for; the effectiveness factor 𝜂 𝑠,CO 2 , which quantifies this ratio, decreases rapidly at more negative potentials and is about 1% near −1.0 V vs SHE due to reactant depletion. Spatial maps reveal pore-bulk alkalization that emerges at higher cathodic bias, with a small, near-wall pH dip due to electrostatic repulsion of hydroxide at the cathode interface. For a fixed aspect ratio L p /d p , narrower pores exhibit larger 𝜂 𝑠,CO 2 by shortening diffusion paths, whereas variations in the aspect ratio L p /d p play a secondary role. A dimensionless analysis (surface/bulk Damköhler numbers) delineates operating regimes. In conclusion, this work offers a concept for incorporating microkinetic models into homogenized porous-electrode models through effectiveness factors and pore-size distribution.

Au-catalyst↗

Detecting change as it occurs

Traditionally climate changes have been detected from long series of observations and long after they have happened. Our 'inverse sequential' procedure, for detecting change as soon as it occurs, describes the existing or most recent data by their frequency distribution. Its parameter(s) are estimated both from the existing set of observations and from the same set augmented by 1,2,....j new observations. Individual-value probability products ('likelihoods') are used to form ratios which yield two probabilities for erroneously accepting the existing parameter(s) as valid for the augmented data set, and vice versa. A genuine parameter change is signaled when these probabilities (or a more stable compound probability) show a progressive decrease. New parameter values can then be estimated from the new observations alone using standard statistical techniques. The inverse sequential procedure will be illustrated for global annual mean temperatures (assumed normally distributed), and for annual numbers of North Atlantic hurricanes (assumed to represent Poisson distributions). The procedure was developed, but not yet tested, for linear or exponential trends, and for chi-squared means or degrees of freedom, a special measure of autocorrelation.

Radok, Uwe↗

Solution of elliptic partial differential equations by fast Poisson solvers using a local relaxation factor. 1: One-step method

An algorithm for solving a large class of two- and three-dimensional nonseparable elliptic partial differential equations (PDE's) is developed and tested. It uses a modified D'Yakanov-Gunn iterative procedure in which the relaxation factor is grid-point dependent. It is easy to implement and applicable to a variety of boundary conditions. It is also computationally efficient, as indicated by the results of numerical comparisons with other established methods. Furthermore, the current algorithm has the advantage of possessing two important properties which the traditional iterative methods lack; that is: (1) the convergence rate is relatively insensitive to grid-cell size and aspect ratio, and (2) the convergence rate can be easily estimated by using the coefficient of the PDE being solved.

Chang, S. C.↗

Pore-Scale Modeling of Electrokinetics in Geomaterials

Pore-scale finite-volume continuum models of electrokinetic processes are used to predict the Debye lengths, velocity, and potential profiles for two-dimensional arrays of circles, ellipses and squares with different orientations. The pore-scale continuum model solves the coupled Navier–Stokes, Poisson, and Nernst–Planck equations to characterize the electro-osmotic pressure and streaming potentials developed on the application of an external voltage and pressure difference, respectively. Here, this model is used to predict the macroscale permeabilities of geomaterials via the widely used Carmen–Kozeny equation and through the electrokinetic coupling coefficients. The permeability results for a two-dimensional X-ray tomography-derived sand microstructure are within the same order of magnitude as the experimentally calculated values. The effect of the particle aspect ratio and orientation on the electrokinetic coupling coefficients and subsequently the electrical and hydraulic tortuosity of the porous media has been determined. These calculations suggest a highly tortuous geomaterial can be efficient for applications like decontamination and desalination.

36 MATERIALS SCIENCE↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

Radiation Mapping for an Unmanned Aerial Vehicle: Development and Simulated Testing of Algorithms for Source Mapping and Navigation Path Generation

Image reconstruction algorithms were developed for radiation source mapping and used for generating the search path of a moving radiation detector, such as one onboard an unmanned aerial vehicle. Simulations consisted of first assuming radioactive sources of varying complexity and estimating the radiation fields that would then be produced by that source distribution. Next, the "measurements" that would result from a pair of adjacent spatial locations were computed. A crude estimate of the source distribution likely to have produced such "measurements" was reconstructed based upon the limited measurements. Location of the next "measurement" was then determined as halfway between the location of the estimated source and the current "measurement." With each additional sample, improved source distribution reconstructions were made and used to inform the immediate direction of detector motion. Source reconstruction or mapping was formulated as an inverse problem solved with either maximum a posteriori or least squares (LS) regression deconvolution methods. Different amounts of noise were added to the simulated "measurements," allowing evaluation of the methods' performances as functions of signal-to-noise ratio of the measured map. As expected, methods that promote sparsity were better suited in reconstructing point sources. Reliable prior information of the source distribution also improved the reconstruction results, especially with distributed sources. With a non-negative least square algorithm and the suggested paths it generated, location of sources was successfully estimated to an accuracy of 0.014 m within nine iterations in a single-source scenario and 12 iterations in a two-source scenario, given a 10% error on the integrated counts and a Poisson distribution of the noise associated with the measured counts.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Ion Bernstein waves in a plasma with a kappa velocity distribution

Using a Vlasov-Poisson model, a numerical investigation of the dispersion relation for ion Bernstein waves in a kappa-distributed plasma has been carried out. The dispersion relation is found to depend significantly on the spectral index of the ions, κ{sub i}, the parameter whose smallness is a measure of the departure from thermal equilibrium of the distribution function. Over all cyclotron harmonics, the typical Bernstein wave curves are shifted to higher wavenumbers (k) if κ{sub i} is reduced. For waves whose frequency lies above the lower hybrid frequency, ω{sub LH}, an increasing excess of superthermal particles (decreasing κ{sub i}) reduces the frequency, ω{sub peak}, of the characteristic peak at which the group velocity vanishes, while the associated k{sub peak} is increased. As the ratio of ion plasma to cyclotron frequency (ω{sub pi}/ω{sub ci}) is increased, the fall-off of ω at large k is smaller for lower κ{sub i} and curves are shifted towards larger wavenumbers. In the lower hybrid frequency band and harmonic bands above it, the frequency in a low-κ{sub i} plasma spans only a part of the intraharmonic space, unlike the Maxwellian case, thus exhibiting considerably less coupling between adjacent bands for low κ{sub i}. It is suggested that the presence of the ensuing stopbands may be a useful diagnostic for the velocity distribution characteristics. The model is applied to the Earth's plasma sheet boundary layer in which waves propagating perpendicularly to the ambient magnetic field at frequencies between harmonics of the ion cyclotron frequency are frequently observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operator induced multigrid algorithms using semirefinement

A variant of multigrid, based on zebra relaxation, and a new family of restriction/prolongation operators is described. Using zebra relaxation in combination with an operator-induced prolongation leads to fast convergence, since the coarse grid can correct all error components. The resulting algorithms are not only fast, but are also robust, in the sense that the convergence rate is insensitive to the mesh aspect ratio. This is true even though line relaxation is performed in only one direction. Multigrid becomes a direct method if an operator-induced prolongation is used, together with the induced coarse grid operators. Unfortunately, this approach leads to stencils which double in size on each coarser grid. The use of an implicit three point restriction can be used to factor these large stencils, in order to retain the usual five or nine point stencils, while still achieving fast convergence. This algorithm achieves a V-cycle convergence rate of 0.03 on Poisson's equation, using 1.5 zebra sweeps per level, while the convergence rate improves to 0.003 if optimal nine point stencils are used. Numerical results for two and three dimensional model problems are presented, together with a two level analysis explaining these results.

Decker, Naomi↗

Operator induced multigrid algorithms using semirefinement

A variant of multigrid, based on zebra relaxation, and a new family of restriction/prolongation operators is described. Using zebra relaxation in combination with an operator-induced prolongation leads to fast convergence, since the coarse grid can correct all error components. The resulting algorithms are not only fast, but are also robust, in the sense that the convergence rate is insensitive to the mesh aspect ratio. This is true even though line relaxation is performed in only one direction. Multigrid becomes a direct method if an operator-induced prolongation is used, together with the induced coarse grid operators. Unfortunately, this approach leads to stencils which double in size on each coarser grid. The use of an implicit three point restriction can be used to factor these large stencils, in order to retain the usual five or nine point stencils, while still achieving fast convergence. This algorithm achieves a V-cycle convergence rate of 0.03 on Poisson's equation, using 1.5 zebra sweeps per level, while the convergence rate improves to 0.003 if optimal nine point stencils are used. Numerical results for two- and three-dimensional model problems are presented, together with a two level analysis explaining these results.

Decker, Naomi Henderson↗

Constraints from isoscaling on the source size in energetic heavy ion collisions

In the framework of the statistical multifragmentation model, the nuclear isoscaling analysis is extended to constrain the ratio between the sizes of the decaying sources formed in a collision between two heavy ions. It is found that the ratio between the probabilities of observing n fragments in each event, for each of the sources, follows a scaling law, similar to the traditional nuclear isoscaling. However, the corresponding slope is sensitive to the source sizes. This property is explained analytically using the grand-canonical ensemble. Furthermore, the extent to which our findings are affected by finite size effects and by the deexcitation of the hot primary fragments is investigated. The scaling turns out to be robust and weakly affected by effects implied by these two aspects. We also find that the Poisson distribution is a fairly good approximation to the above mentioned probabilities, associated with both the primordial fragments, produced at the breakup stage, and the final ones, found at the end of the fragment deexcitation process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multilevel Sequential Monte Carlo Samplers for Normalizing Constants

This article considers the sequential Monte Carlo (SMC) approximation of ratios of normalizing constants associated to posterior distributions which in principle rely on continuum models. Therefore, the Monte Carlo estimation error and the discrete approximation error must be balanced. A multilevel strategy is utilized to substantially reduce the cost to obtain a given error level in the approximation as compared to standard estimators. Two estimators are considered and relative variance bounds are given. The theoretical results are numerically illustrated for two Bayesian inverse problems arising from elliptic partial differential equations (PDEs). The examples involve the inversion of observations of the solution of (i) a 1-dimensional Poisson equation to infer the diffusion coefficient, and (ii) a 2-dimensional Poisson equation to infer the external forcing.

97 MATHEMATICS AND COMPUTING↗

Measuring the X-ray luminosities of DESI groups from eROSITA Final Equatorial-Depth Survey – I. X-ray luminosity–halo mass scaling relation

ABSTRACT We use the eROSITA Final Equatorial-Depth Survey (eFEDS) to measure the rest-frame 0.1–2.4 keV band X-ray luminosities of ∼600 000 DESI groups using two different algorithms in the overlap region of the two observations. These groups span a large redshift range of 0.0 ≤ zg ≤ 1.0 and group mass range of $10^{10.76}\, h^{-1}\, \mathrm{M}_{\odot } \le M_h \le 10^{15.0}\, h^{-1}\, \mathrm{M}_{\odot }$. (1) Using the blind detection pipeline of eFEDS, we find that 10932 X-ray emission peaks can be cross-matched with our groups, ∼38 per cent of which have a signal-to-noise ratio $\rm {S}/\rm {N} \ge 3$ in X-ray detection. Comparing to the numbers reported in previous studies, this matched sample size is a factor of ∼6 larger. (2) By stacking X-ray maps around groups with similar masses and redshifts, we measure the average X-ray luminosity of groups as a function of halo mass in five redshift bins. We find that in a wide halo mass range, the X-ray luminosity, LX, is roughly linearly proportional to Mh and quite independent to the redshift of the groups. (3) We use a Poisson distribution to model the X-ray luminosities obtained using two different algorithms and obtain the best-fit $L_{\rm X}=10^{28.46\pm 0.03}M_{\rm h}^{1.024\pm 0.002}$ and $L_{\rm X}=10^{26.73 \pm 0.04}M_{\rm h}^{1.140 \pm 0.003}$ scaling relations, respectively. The best-fit slopes are flatter than the results previously obtained but closer to a self-similar prediction.

Astronomy & Astrophysics↗

Direct Detection Doppler Lidar for Spaceborne Wind Measurement

Aerosol and molecular based versions of the double-edge technique can be used for direct detection Doppler lidar spaceborne wind measurement. The edge technique utilizes the edge of a high spectral resolution filter for high accuracy wind measurement using direct detection lidar. The signal is split between an edge filter channel and a broadband energy monitor channel. The energy monitor channel is used for signal normalization. The edge measurement is made as a differential frequency measurement between the outgoing laser signal and the atmospheric backscattered return for each pulse. As a result the measurement is insensitive to laser and edge filter frequency jitter and drift at a level less than a few parts in 10(exp 10). We have developed double edge versions of the edge technique for aerosol and molecular-based lidar measurement of the wind. Aerosol-based wind measurements have been made at Goddard Space Flight Center and molecular-based wind measurements at the University of Geneva. We have demonstrated atmospheric measurements using these techniques for altitudes from 1 to more than 10 km. Measurement accuracies of better than 1.25 m/s have been obtained with integration times from 5 to 30 seconds. The measurements can be scaled to space and agree, within a factor of two, with satellite-based simulations of performance based on Poisson statistics. The theory of the double edge aerosol technique is described by a generalized formulation which substantially extends the capabilities of the edge technique. It uses two edges with opposite slopes located about the laser frequency at approximately the half-width of each edge filter. This doubles the signal change for a given Doppler shift and yields a factor of 1.6 improvement in the measurement accuracy compared to the single edge technique. The use of two high resolution edge filters substantially reduces the effects of Rayleigh scattering on the measurement, as much as order of magnitude, and allows the signal to noise ratio to be substantially improved in areas of low aerosol backscatter. We describe a method that allows the Rayleigh and aerosol components of the signal to be independently determined using the two edge channels and an energy monitor channel. The effects of Rayleigh scattering may then subtracted from the measurement and we show that the correction process does not significantly increase the measurement noise for Rayleigh to aerosol ratios up to 10. We show that for small Doppler shifts a measurement accuracy of 0.4 m/s can be obtained for 5000 detected photon, 1.2 m/s for 1000 detected photons, and 3.7 m/s for 50 detected photons for a Rayleigh to aerosol ratio of 5. Methods for increasing the dynamic range of the aerosol-based system to more than +/- 100 m/s are given.

Korb, C. Laurence↗

Simulation Model of Mobile Detection Systems

In this paper, we consider a mobile source that we attempt to detect with man-portable, vehicle-mounted or boat-mounted radiation detectors. The source is assumed to transit an area populated with these mobile detectors, and the objective is to detect the source before it reaches a perimeter. We describe a simulation model developed to estimate the probability that one of the mobile detectors will come in to close proximity of the moving source and detect it. We illustrate with a maritime simulation example. Our simulation takes place in a 10 km by 5 km rectangular bay patrolled by boats equipped with 2-inch x 4-inch x 16-inch NaI detectors. Boats to be inspected enter the bay and randomly proceed to one of seven harbors on the shore. A source-bearing boat enters the mouth of the bay and proceeds to a pier on the opposite side. We wish to determine the probability that the source is detected and its range from target when detected. Patrol boats select the nearest in-bound boat for inspection and initiate an intercept course. Once within an operational range for the detection system, a detection algorithm is started. If the patrol boat confirms the source is not present, it selects the next nearest boat for inspection. Each run of the simulation ends either when a patrol successfully detects a source or when the source reaches its target. Several statistical detection algorithms have been implemented in the simulation model. First, a simple k-sigma algorithm, which alarms with the counts in a time window exceeds the mean background plus k times the standard deviation of background, is available to the user. The time window used is optimized with respect to the signal-to-background ratio for that range and relative speed. Second, a sequential probability ratio test [Wald 1947] is available, and configured in this simulation with a target false positive probability of 0.001 and false negative probability of 0.1. This test is utilized when the mobile detector maintains a constant range to the vessel being inspected. Finally, a variation of the sequential probability ratio test that is more appropriate when source and detector are not at constant range is available [Nelson 2005]. Each patrol boat in the fleet can be assigned a particular zone of the bay, or all boats can be assigned to monitor the entire bay. Boats assigned to a zone will only intercept and inspect other boats when they enter their zone. In our example simulation, each of two patrol boats operate in a 5 km by 5 km zone. Other parameters for this example include: (1) Detection range - 15 m range maintained between patrol boat and inspected boat; (2) Inbound boat arrival rate - Poisson process with mean arrival rate of 30 boats per hour; (3) Speed of boats to be inspected - Random between 4.5 and 9 knots; (4) Patrol boat speed - 10 knots; (5) Number of detectors per patrol boat - 4-2-inch x 4-inch x 16-inch NaI detectors; (6) Background radiation - 40 counts/sec per detector; and (7) Detector response due to radiation source at 1 meter - 1,589 counts/sec per detector. Simulation results indicate that two patrol boats are able to detect the source 81% of the time without zones and 90% of the time with zones. The average distances between the source and target at the end of the simulation is 5,866 km and 5,712 km for non-zoned and zoned patrols, respectively. Of those that did not reach the target, the average distance to the target is 7,305 km and 6,441 km respectively. Note that a design trade-off exists. While zoned patrols provide a higher probability of detection, the nonzoned patrols tend to detect the source farther from its target. Figure 1 displays the location of the source at the end of 1,000 simulations for the 5 x 10 km bay simulation. The simulation model and analysis described here can be used to determine the number of mobile detectors one would need to deploy in order to have a have reasonable chance of detecting a source in transit. By fixing the source speed to zero, the same model could be used to estimate how long it would take to detect a stationary source. For example, the model could predict how long it would take plant staff performing assigned duties carrying dosimeters to discover a contaminated spot in the facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Significant mobility enhancement in extremely thin highly doped ZnO films

Highly Ga-doped ZnO (GZO) films of thicknesses d = 5, 25, 50, and 300 nm, grown on 160-nm ZnO buffer layers by molecular beam epitaxy, had 294-K Hall-effect mobilities μ{sub H} of 64.1, 43.4, 37.0, and 34.2 cm{sup 2}/V-s, respectively. This extremely unusual ordering of μ{sub H} vs d is explained by the existence of a very high-mobility Debye tail in the ZnO, arising from the large Fermi-level mismatch between the GZO and the ZnO. Scattering theory in conjunction with Poisson analysis predicts a Debye-tail mobility of 206 cm{sup 2}/V-s at the interface (z = d), falling to 58 cm{sup 2}/V-s at z = d + 2 nm. Excellent fits to μ{sub H} vs d and sheet concentration n{sub s} vs d are obtained with no adjustable parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of geometric, thermal and tunneling effects on nano-transistors

Electronic transistors are fundamental building blocks of large scale integrated circuits in modern advanced electronic equipments, and their sizes have been down-scaled to nanometers. Modeling and simulations in the framework of quantum dynamics have emerged as important tools to study functional characteristics of these nano-devices. This work explores the effects of geometric shapes of semiconductor–insulator interfaces, phonon–electron interactions, and quantum tunneling of three-dimensional (3D) nano-transistors. First, we propose a two-scale energy functional to describe the electron dynamics in a dielectric continuum of device material. Coupled governing equations, i.e., Poisson–Kohn–Sham (PKS) equations, are derived by the variational principle. Additionally, it is found that at a given channel cross section area and gate voltage, the geometry that has the smallest perimeter of the channel cross section offers the largest channel current, which indicates that ultra-thin nanotransistors may not be very efficient in practical applications. Moreover, we introduce a new method to evaluate quantum tunneling effects in nanotransistors without invoking the comparison of classical and quantum predictions. It is found that at a given channel cross section area and gate voltage, the geometry that has the smallest perimeter of the channel cross section has the smallest quantum tunneling ratio, which indicates that geometric defects can lead to higher geometric confinement and larger quantum tunneling effect. Furthermore, although an increase in the phonon–electron interaction strength reduces channel current, it does not have much impact to the quantum tunneling ratio. Finally, advanced numerical techniques, including second order elliptic interface methods, have been applied to ensure computational accuracy and reliability of the present PKS simulation.