Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photonic devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

B—N–Bond–Embedded Triplet Terpolymers with Small Singlet–Triplet Energy Gaps for Suppressing Non–Radiative Recombination and Improving Blend Morphology in Organic Solar Cells

Suppressing the photon energy loss (E loss ), especially the non-radiative loss, is of importance to further improve the device performance of organic solar cells (OSCs). However, typical π-conjugated semiconductors possess a large singlet–triplet energy gap (ΔE ST ), leading to a lower triplet state than charge transfer state and contributing to a non-radiative loss channel of the photocurrent by the triplet state. Herein, a series of triplet polymer donors are developed by introducing a BNIDT block into the PM6 polymer backbone. Further, the high electron affinity of BNIDT and the opposite resonance effect of the B—N bond in BNIDT results in a lowered highest occupied molecular orbital (HOMO) and a largely reduced ΔE ST . Moreover, the morphology of the active blends is also optimized by fine-tuning the BNIDT content. Therefore, non-radiative recombination via the terminal triplet loss channels and morphology traps is effectively suppressed. The PNB-3 (with 3% BNIDT):L8-BO device exhibits both small ΔE ST and optimized morphology, favoring more efficient charge transfer and transport. Finally, the simultaneously enhanced V oc of 0.907 V, J sc of 26.59 mA cm –2 , and FF of 78.86% contribute to a champion PCE of 19.02%. Therefore, introducing B—N bonds into benchmark polymers is a possible avenue toward higher-performance of OSCs.

36 MATERIALS SCIENCE↗

A General and Modular Approach to Solid-State Integration of Zero-Dimensional Quantum Systems

Here, we present an all-electrical readout mechanism for quasi-0D quantum states (0D-QS), such as point defects, adatoms, and molecules, that is modular and general, providing an approach that is amenable to scaling and integration with other solid-state quantum technologies. Our approach relies on the creation of high-quality tunnel junctions via the mechanical exfoliation and stacking of multilayer graphene (MLG) and hexagonal boron nitride (hBN) to encapsulate the target system in an MLG/hBN/0D-QS/hBN/MLG heterostructure. This structure allows for all-electronic spectroscopy and readout of candidate systems through a combination of coulomb and spin-blockade. As a proof of principle, we demonstrate electronic tunneling spectroscopy of point defects in hBN and the molecular qubit vanadyl phthalocyanine. Our approach demonstrates a new pathway for the incorporation of molecules and atomic defects into solid-state quantum devices and circuits along with a readout scheme that does not rely on highly constrained optical processes for photonic readout.

defects in hexagonal boron nitride↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Entanglement Verification of Hyperentangled Photon Pairs

In this work, we experimentally investigate the properties of hyperentangled states displaying simultaneous entanglement in multiple degrees of freedom and find that Bell tests beyond the standard Clauser-Horne-Shimony-Holt inequality can reveal a higher-dimensional nature in a device-independent way. Specifically, we show that hyperentangled states possess more than just simultaneous entanglement in separate degrees of freedom but also entanglement in a higher-dimensional Hilbert space. We also verify the steerability of hyperentangled quantum states by steering different photonic degrees of freedom.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bidirectional Multiphoton Communication between Remote Superconducting Nodes

Quantum communication test beds provide a useful resource for experimentally investigating a variety of communication protocols. Here we demonstrate a superconducting circuit test bed with bidirectional multiphoton state transfer capability using time -domain shaped wave packets. Further, the system we use to achieve this comprises two remote nodes, each including a tunable superconducting transmon qubit and a tunable microwave -frequency resonator, linked by a 2 m-long superconducting coplanar waveguide, which serves as a transmission line. We transfer both individual and superposition Fock states between the two remote nodes, and additionally show that this bidirectional state transfer can be done simultaneously, as well as being used to entangle elements in the two nodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Local Markers for Crystalline Topology

Over the last few years, crystalline topology has been used in photonic crystals to realize edge- and corner-localized states that enhance light-matter interactions for potential device applications. However, the band-theoretic approaches currently used to classify bulk topological crystalline phases cannot predict the existence, localization, or spectral isolation of any resulting boundary-localized modes. While interfaces between materials in different crystalline phases must have topological states at some energy, these states need not appear within the band gap, and thus may not be useful for applications. Here, we derive a class of local markers for identifying material topology due to crystalline symmetries, as well as a corresponding measure of topological protection. As our real-space-based approach is inherently local, it immediately reveals the existence and robustness of topological boundary-localized states, yielding a predictive framework for designing topological crystalline heterostructures. In conclusion, beyond enabling the optimization of device geometries, we anticipate that our framework will also provide a route forward to deriving local markers for other classes of topology that are reliant upon spatial symmetries.

74 ATOMIC AND MOLECULAR PHYSICS↗

Preliminary design report, Large Space Telescope OTA/SI Phase B study: High speed area photometer

A photometer is examined which combines several features from separate instruments into a single package. The design presented has both point and area photometry capability with provision for inserting filters to provide spectral discrimination. The electronics provide for photon counting mode for the point detectors and both photon counting and analog modes for the area detector. The area detector also serves as a target locating device for the point detectors. Topics discussed include: (1) electronic equipment requirements, (2) optical properties, (3) structural housing for the instrument, (4) motors and other mechanical components, (5) ground support equipment, and (6) environment control for the instrument. Engineering drawings and block diagrams are shown.

Source record↗

Instrumental technique in X-ray astronomy

A detailed review of the development of instruments for X-ray astronomy is given with major emphasis on nonfocusing high-sensitivity counter techniques used to detect cosmic photons in the energy range between 0.20 and 300 keV. The present status of X-ray astronomy is summarized together with significant results of the Uhuru observations, and photon interactions of importance for the detection of X-rays in space are noted. The three principal devices used in X-ray astronomy (proportional, scintillation, and solid-state counters) are described in detail, data-processing systems for these devices are briefly discussed, and the statistics of nuclear counting as applied to X-ray astronomy is outlined analytically. Effects of the near-earth X-ray environment and atmospheric gamma-ray production on X-ray detection by low-orbit satellites are considered. Several contemporary instruments are described (proportional-counter systems, scintillation-counter telescopes, modulation collimators), and X-ray astronomical satellite missions are tabulated.

Peterson, L. E.↗

Laser pulse detection method and apparatus

A sensor is described for detecting the difference in phase of a pair of returned light pulse components, such as two components of a light pulse of an optical gyro. In an optic gyro, the two light components have passed in opposite directions through a coil of optical fiber, with the difference in phase of the returned light components determining the intensity of light shining on the sensor. The sensor includes a CCD (charge coupled device) that receives the pair of returned light components to generate a charge proportional to the number of photons in the received light. The amount of the charge represents the phase difference between the two light components. At a time after the transmission of the light pulse and before the expected time of arrival of the interfering light components, charge accumulating in the CCD as a result of reflections from components in the system, are repeatedly removed from the CCD, by transferring out charges in the CCD and dumping these charges.

Goss, W.↗

Optimization of niobium tunnel junctions as X-ray detectors

We report on our ongoing work using Nb/Al/AlO(x)/Nb junctions for the detection of X-rays. Detectors based on superconducting tunneling junctions offer the prospect of resolution over an order of magnitude higher than is obtainable with the current generation of semiconductor-based detectors. Results of measurements taken at 1.85 K (a temperature achievable with current space flight technology) include the current-voltage (I-V) curve, subgap current vs temperature, the dependence of the superconducting current on the applied magnetic field (Fraunhofer pattern), X-ray pulses, and the spectra from a 6 keV X-ray source which gave an intrinsic device resolution of approximately 700 eV. The collection of more than 10 exp 5 electrons per 6 keV photon is established.

Saulnier, Gregory G.↗

A loophole-free Bell's inequality experiment

The proof of Nature's nonlocality through Bell-type experiments is a topic of longstanding interest. Nevertheless, no experiments performed thus far have avoided the so-called 'detection loophole,' arising from low detector efficiencies and angular-correlation difficulties. In fact, most, if not all, of the systems employed to date can never close this loophole, even with perfect detectors. In addition, another loophole involving the non-rapid, non-random switching of various parameter settings exists in all past experiments. We discuss a proposal for a potentially loophole-free Bell's inequality experiment. The source of the EPR-correlated pairs consists of two simultaneously-pumped type-2 phase-matched nonlinear crystals and a polarizing beam splitter. The feasibility of such a scheme with current detector technology seems high, and will be discussed. We also present a single-crystal version, motivated by other work presented at this conference. In a separate experiment, we have measured the absolute detection efficiency and time response of four single-photon detectors. The highest observed efficiencies were 70.7 plus or minus 1.9 percent (at 633 nm, with a device from Rockwell International) and 76.4 plus or minus 2.3 percent (at 702 nm, with an EG&G counting module). Possible efficiencies as high as 90 percent were implied. The EG&G devices displayed sub-nanosecond time resolution.

Kwiat, Paul G.↗

A high-speed photonic clock and carrier regenerator

As data communications rates climb toward 10 Gbits/s, clock recovery and synchronization become more difficult, if not impossible, using conventional electronic circuits. The high-speed photonic clock regenerator described in this article may be more suitable for such use. This photonic regenerator is based on a previously reported photonic oscillator capable of fast acquisition and synchronization. With both electrical and optical clock inputs and outputs, the device is easily interfaced with fiber-optic systems. The recovered electrical clock can be used locally and the optical clock can be used anywhere within a several kilometer radius of the clock/carrier regenerator.

Yao, X. S.↗

A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution for the readout while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest or by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest of by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

Laser pulse detection method and apparatus

A sensor is described for detecting the difference in phase of a pair of returned light pulse components, such as the two components of a light pulse of an optical gyro. In an optic gyro, the two light components have passed in opposite directions through a coil of optical fiber, with the difference in phase of the returned light components determining the intensity of light shining on the sensor. The sensor includes a CCD (charge coupled device) that receives the pair of returned light components to generate a charge proportional to the number of photons in the received light. The amount of the charge represents the phase difference between the two light components. At a time after the transmission of the light pulse and before the expected time of arrival of the interfering light components, charge accumulating in the CCD as a result of reflections from optical components in the system, are repeatedly removed from the CCD, by transferring out charges in the CCD and dumping these charges.

Goss, Willis C.↗

Real Time Optical Receiver Project

The goals for the Real Time Optical Receiver project are to Infuse Consultative Committee for Space Data Systems High Photon Efficiency standard into missions, such as Artemis and to provide a real time ground receiver solution (fiber device, detector, real time FPGA-based receiver) that is: (1) Scalable: data rate, atmosphere conditions, telescope aperture, etc., and (2) Uses COTS components when available and work with companies to move custom parts to COTS.

Katz, Evan J.↗

Godiva IER268 PDV Measurements

PowerPoint slides providing a quick-look of photon Doppler velocimetry (PDV) data taken during a series bursts using the Godiva machine located at the NNSS Device Assembly Facility. Vibrations, or ringing, of approximately 7.2 to 7.8 kHz were observed.

47 OTHER INSTRUMENTATION↗

X-ray single Photon Spectrometers

The research at Yale on superconducting tunnel junctions (STJs) focussed on x-ray detectors, using a 5.9 keV x-ray source. All the Yale tests were carried out at 0.21 K, in a two-stage helium 3 dewar. Careful attention was given to grounding and shielding. All current waveforms were digitially recorded and analyzed subsequently on computer. The imaging device geometry was studied. This allows imaging along the length of the tantalum (Ta) absorber, which is 600 nm thick to provide good x-ray absorption. The quasiparticles produced by single photon absorption rapidly cool to the Ta gap, E(sub g_Ta) = 1.4 meV, and then diffuse. They are trapped in the A1 traps at the two ends (E(sub g_A1) = 0.4 meV), to give two charges that tunnel out of the A1 traps, Q(sub 1) and Q(sub 2). The total charge is Q = Q(sub 1) + Q(sub 2). This lateral trapping is what allows imaging.

Prober, Daniel↗