Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Analog Signal Multiplexing System for the Iota Proton Injector

The Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Operations is to commission the 2.5 MeV IOTA Proton Injector (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function correctors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103↗

Analog Signal Multiplexing System for the IOTA Proton Injector

he Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Opera-tions is to commission the 2.5 MeV IOTA Proton Injec-tor (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function cor-rectors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103↗

MICE Staging and Status

Ionization cooling will be a key technique for a high-intensity Neutrino Factory or Muon Collider. The Muon Ionization Cooling Experiment (MICE) is a high-precision, staged accelerator experiment being performed at Rutherford Appleton Laboratory in the UK. Its goal is the first demonstration, with 0.1% resolution, of the feasibility of reducing the transverse emittance of a beam of muons by ionization cooling in low-Z absorbers. MICE is being staged in the following steps: I. Creating and characterizing a beam of muons; II. Measuring their emittance; III. Systematic comparison of successive measurements; IV. Inserting absorber; V. Reaccelerating longitudinally; and VI. Complete '10%-cooling' test. Step I is currently in progress with Step II to commence next year; completion of Step VI is anticipated in approx2012.

43 PARTICLE ACCELERATORS↗

Neutron production using a pyroelectric driven target coupled with a gated field ionization source

A palm sized, portable neutron source would be useful for widespread implementation of detection systems for shielded, special nuclear material. We present progress towards the development of the components for an ultracompact neutron generator using a pulsed, meso-scale field ionization source, a deuterated (or tritiated) titanium target driven by a negative high voltage lithium tantalate crystal. Neutron production from integrated tests using an ion source with a single, biased tungsten tip and a 3 Multiplication-Sign 1 cm, vacuum insulated crystal with a plastic deuterated target are presented. Component testing of the ion source with a single tip produces up to 3 nA of current. Dielectric insulation of the lithium tantalate crystals appears to reduce flashover, which should improve the robustness. The field emission losses from a 3 cm diameter crystal with a plastic target and 6 cm diameter crystal with a metal target are compared.

43 PARTICLE ACCELERATORS↗

The Tandem-ALPI-PIAVE accelerator complex of LNL

Heavy ion beams are delivered at the Laboratori Nazionali di Legnaro by the accelerator complex Tandem-ALPI-PIAVE. The Tandem XTU is a Van de Graaff accelerator normally operated at terminal voltages of up to about 15 MV. The Tandem accelerator can be operated in stand-alone mode or as an injector for the linac booster ALPI. The linear accelerator ALPI is built of superconducting resonant cavities and consists of a low-beta branch, particularly important for the acceleration of the heavier mass ions, a medium-beta branch, and a high-beta branch. ALPI can be operated also with the PIAVE injector that consists of a superconducting linac and an ECR source. The PIAVE source was mainly used for the acceleration of intense noble gas beams but most recently also a first metallic beam was delivered to the users. The accelerator complex delivers beams of ions from protons to gold in three experimental areas on 11 different beam lines. A rich scientific activity is ongoing at the Tandem-ALPI-PIAVE accelerator complex, beam time being shared between nuclear physics research and applied and interdisciplinary physics research. An overview of the present status and perspectives of the Tandem-ALPI-PIAVE complex and its physics program is given in the present paper.

43 PARTICLE ACCELERATORS↗

A real-time intercepting beam-profile monitor for a medical cyclotron

There is a lack of real-time continuous beam-diagnostic tools for medical cyclotrons due to high power deposition during proton irradiation. To overcome this limitation, we have developed a profile monitor that is capable of providing continuous feedback about beam shape and current in real time while it is inserted in the beam path. This enables users to optimize the beam profile and observe fluctuations in the beam over time with periodic insertion of the monitor.

43 PARTICLE ACCELERATORS↗

Conceptual design of International Linear Collider damping ring wiggler based on a hybrid technology

A magnetic design of a failure-free damping ring wiggler with 100% duty factor, 55.6 mm gap, and field exceeding 1.6 T is proposed. The insertion device is based on permanent magnets and specially shimmed poles that capable to meet the requirements of the International Linear Collider (ILC) damping rings (including positron one), with field quality and gap comparable to that projected for ILC using superconducting wiggler. Performance improvement of the modified hybrid design is attained due to yoke reduction down to six separated strips and maximized packaging of the midgrade (or high-grade) parallelepiped magnet blocks surrounding the Permendur poles. Economical efficiency is demonstrated on the base of calculated amount of magnetic material. A cryogenic variant of the hybrid design may certainly provide good sustainability to harsh radiation environment and further enhancement of the design efficiency within the state of the art.

43 PARTICLE ACCELERATORS↗

Gamma-Beta-Neutron Detectors Set-Up at ALTO

A multi detection system consisted of 90 {sup 3}He counters, gamma detector and beta detector has been installed at beamline of the accelerator complex ALTO. The system allows performing direct measurements of probability of delayed neutron emission from spontaneous fission fragments. A trial experiment was carried out to test the detection system created.

43 PARTICLE ACCELERATORS↗

Improvement in Stability of SPring-8 Standard X-Ray Monochromators with Water-Cooled Crystals

SPring-8 standard double-crystal monochromators containing water-cooled crystals were stabilized to a sufficient level to function as a part of optics components to supply stable microfocused x-ray beams, by determining causes of the instability and then removing them. The instability was caused by two factors--thermal deformation of fine stepper stages in the monochromator, which resulted in reduction in beam intensity with time, and vibrations of coolant supply units and vacuum pumps, which resulted in fluctuation in beam intensity. We remodeled the crystal holders to maintain the stage temperatures constant with water, attached x-ray and electron shields to the stages in order to prevent their warming up, introduced accumulators in the water circuits to absorb pressure pulsation, used polyurethane tubes to stabilize water flow, and placed rubber cushions under scroll vacuum pumps. As a result, the intensity reduction rate of the beam decreased from 26% to 1% per hour and the intensity fluctuation from 13% to 1%. The monochromators were also modified to prevent radiation damage to the crystals, materials used as a water seal, and motor cables.

43 PARTICLE ACCELERATORS↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

A compact 10 kW, 476 MHz solid state radio frequency amplifier for pre-buncher cavity of free electron laser injector linear accelerator

A 10 kW, 476 MHz, 0.1% duty cycle solid state RF amplifier system for driving sub-harmonic, pre-buncher cavity of IR-FEL injector LINAC, has been developed at RRCAT. The 10 kW power is achieved by combining output of eight 1400 W amplifier modules using 8-way planar corporate combiner. The solid state amplifier modules have been developed using 50 V RF LDMOS transistors which although meant for push-pull operation are being used in single ended configuration with matching circuit developed on a thin (25 mils), high dielectric constant (9.7), low loss microwave laminate with an aim to have a compact structure. Ease of fabrication, modularity, small size, and low cost are the important features of this design which could be used as a template for low duty cycle medium to high pulsed power UHF amplifier system.

43 PARTICLE ACCELERATORS↗

Particle-in-cell techniques for the study of space charge effects in the Advanced Cryogenic Gas Stopper

The Facility for Rare Isotope Beams, FRIB, will significantly increase the rates and varieties of rare isotopes compared to those presently available at existing rare-isotope facilities. The production of stopped beams via the current generation of linear gas stopping devices available is not well matched to the beam intensities that will be available at FRIB. Many experiments that make use of reaccelerated beams, from the ReA facility, greatly benefit from having the highest-intensity, rare-isotope beams possible. Some experiments would also benefit greatly from stopped beams with improved purity. In this paper, the intensity bottlenecks of FRIB’s newest linear gas stopper are studied via experiment and simulation in support of a future detailed conceptual design of a next-generation linear gas stopper that can provide rare-isotope beams with rates of 10^8 pps, a factor of 50 higher than the current state-of-the-art system, with improved beam purity.

43 PARTICLE ACCELERATORS↗

MUSETT and the Spectroscopy of Heavy Elements at GANIL

The new MUSETT silicon-wall has been built to study and obtain detailed spectroscopic information on the transfermium and transactinide elements. MUSETT is located at GANIL at the detection plane of VAMOS, the latter coupled with the EXOGAM germanium array. Results from the in-beam commissioning are reported and an overview of our future experimental program will be given.

43 PARTICLE ACCELERATORS↗

A diagnosis of intense ion beam by CR-39 detectors analyzing the back scattered particles

A new diagnosis method has been developed utilizing back scattered particles for high energy intense ion beams. The CR-39 detector mounted on the uniform back-scatterer was irradiated with {sup 4}He{sup 2+} ions with an energy 25 MeV/n, which is never recorded as etchable track in CR-39. We found that it is possible to diagnose by analyzing the etch pits on the rear surface of CR-39 that directly contacted on the back-scatterers. It turns out that most of etch pits in the rear surface are made by the backscattered particles by investigating the growth pattern of each etch pit with multi-step etching technique. This method allows simple diagnosis of the ion beam profile and intensity distribution in mixed radiation field such as laser-driven ion acceleration experiments.

43 PARTICLE ACCELERATORS↗

R and D toward a compact high-brilliance X-ray source based on channeling radiation

X-rays have been valuable to a large number of fields including Science, Medicine, and Security. Yet, the availability of a compact high-spectral brilliance X-ray sources is limited. A technique to produce X-rays with spectral brilliance B{approx} 10{sup 12} photons.(mm-mrd){sup -2}. (0.1% BW){sup -1}.s{sup -1} is discussed. The method is based on the generation and acceleration of a low-emittance field-emitted electron bunches. The bunches are then focused on a diamond crystal thereby producing channeling radiation. In this paper, after presenting the overarching concept, we discuss the generation, acceleration and transport of the low-emittance bunches with parameters consistent with the production of high-brilliance X-rays through channeling radiation. We especially consider the example of the Advanced Superconducting Test Accelerator (ASTA) currently in construction at Fermilab where a proof-of-principle experiment is in preparation.

43 PARTICLE ACCELERATORS↗

ATLAS jet trigger update for the LHC run II

The CERN Large Hadron Collider is the biggest and most powerful particle collider ever built. It produces up to 40 million proton-proton collisions per second at unprecedented energies to explore the fundamental laws and properties of Nature. The ATLAS experiment is one of the detectors that analyses and records these collisions. It generates dozens of GB/s of data that has to be reduced before it can be permanently stored, the event selection is made by the ATLAS trigger system, which reduces the data volume by a factor of 105. The trigger system has to be highly configurable in order to adapt to changing running conditions and maximize the physics output whilst keeping the output rate under control. A particularly interesting pattern generated during collisions consists of a collimated spray of particles, known as a hadronic jet. To retain the interesting jets and efficiently reject the overwhelming background, optimal jet energy resolution is needed. Therefore the Jet trigger software requires CPU-intensive reconstruction algorithms. In order to reduce the resources needed for the reconstruction step, a partial detector readout scheme was developed, which effectively suppresses the low activity regions of the calorimeter. In this paper we describe the overall ATLAS trigger software, and the jet trigger in particular, along with the improvements made on the system. We then focus on detailed studies of the algorithm timing and the performance impact of the full and partial calorimeter readout schemes. We conclude with an outlook of the jet trigger plans for the next LHC data-taking period. (authors)

43 PARTICLE ACCELERATORS↗