Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Laboratory and Field Characterization of the Electrical Response of Modules Containing Configurable Current Cells (C3) Under Non-Optimal Conditions Such as Shading (Final Report)

This work is to be conducted in support of the American Made Challenges Solar Prize. The intent is to connect competitor teams with national laboratories that can help accelerate the development of innovative solutions and products. Teams who have won the Set! and Go! Contests are eligible to utilize vouchers at national laboratories to advance their ideas. Laboratory and field characterization of the electrical response of modules containing Configurable Current Cells (C3) under non-optimal conditions such as shading.

14 SOLAR ENERGY↗

Solar-battery integrated DC system

A DC bus is connected to a PV array, a battery or both, to power a grid connected inverter load on the bus. A system and method is described for controlling current flow on a DC bus regardless of the type of inverter. A converter receives a DC battery voltage. A switching module controls current flow through the converter. A current generator generates a reference current in response to a reference voltage. A comparator connected at the output of the current generator compares the reference current with a battery current and outputs a signal to a controller. The controller generates a reference value. A PWM generator modulates the switch module to control current flow and energy flow between the DC bus and the battery. The current from the DC bus to the inverter is controlled to allow proper grid-connected operation regardless of inverter type.

Atcitty, Stanley↗

CCM vs. CRM Design Optimization of a Boost-derived Parallel Active Power Decoupler for Microinverter Applications

Single-phase inverter or rectifier systems often make use of an auxiliary active power decoupler (APD) to balance the mismatch between steady DC power and fluctuating AC power. This paper deals with efficiency and size optimization of a parallel boost-type APD circuit for PV microinverter applications. Specifically, design of an eGaNFET-based, 400 W APD circuit, employing planar inductor and operating in either continuous conduction mode (CCM) or critical conduction mode (CRM) is considered. Available design variables including inductance value, inductor core geometry, capacitor voltage, switching frequency, and modulation scheme (CCM vs. CRM) are explored to identify Pareto-optimal configurations, which can achieve low California Energy Commission (CEC) efficiency drop while also reducing the footprint area of the inductor. The theoretical study predicts that the optimal CRM design can achieve 37% reduced inductor size, while operating with similar efficiency drop, compared to the optimal CCM design. Experimental results, obtained using two separate 40 V, 400 W hardware prototypes for CCM and CRM, are presented to verify the analyses.

14 SOLAR ENERGY↗

High-Fidelity Models and Fast EMT Simulation Algorithms for Isolated Multi-port Autonomous Reconfigurable Solar power plant (MARS)

The integration of hybrid photovoltaic (PV) and energy storage system (ESS) based plants has become a promising way of solving the intermittency of PV plants and providing frequency support to the power grid. The multi-port autonomous reconfigurable solar power plant (MARS) can integrate the PV systems and ESSs to an ac grid and dc lines. The proposed isolated MARS incorporates an isolated converter that connects to the PV arrays and is based on the dual active bridge (DAB) converter. The high frequency switching in the DAB and the means to control the DAB converter using delays between switching signals lead to the need for a small timestep in simulations. Moreover, several hundreds of modules that include a DAB converter are present in the MARS. The small timestep and the presence of several hundreds of modules lead to a significant rise in the overall simulation time. To address this issue, simulation algorithms like numerical stiffness-based hybrid discretization and the hysteresis relaxation technique are applied to the switched system model of isolated MARS. Additionally, an event-driven interpolating method is introduced to help increase the minimum timestep to simulate the conventional DAB converter model while maintaining high accuracy in the simulation results. The developed model is validated by comparison with its reference model built in the PSCAD/EMTDC and MATLAB software environments using library components.

Xia, Qian↗

On the uncertainty of estimating photovoltaic soiling using nearby soiling data

The accumulation of dust on the surface of photovoltaic modules can reduce their performance and affect the cost competitiveness of this technology. This phenomenon is known as soiling and can be mitigated through appropriate corrective and/or preventive actions. In order to maximize its effectiveness, it is important to plan the soiling mitigation strategy even before the PV system is operational. This is typically done through a nearest neighbor approach, by estimating soiling using data from the nearest operational photovoltaic system. This work focuses on understanding the uncertainty related to this practice. For this purpose, the semi-variance function is used to study the dissimilarity between the soiling losses of two locations in California depending on their distance. The results show that, when the soiling loss at a nearby system is used to estimate soiling of a site, the uncertainty can be approximated to increase linearly at a rate of 0.08-0.10%/km up to 60 or 80 km. After this distance, the use of a nearest neighbor approach is no longer justified, as it produces an uncertainty as big as the average soiling loss of the sites in the dataset used in this study. In some conditions, uncertainties > 0% are found also for sites located within 25 km, meaning that even close-by systems might soil differently.

14 SOLAR ENERGY↗

System-level performance and degradation of 21 GWDC of utility-scale PV plants in the United States

We assess the performance of a fleet of 411 utility-scale (i.e., >5 MWAC and ground-mounted) photovoltaic (PV) projects totaling 21.1 GWDC (16.3 GWAC) of capacity, which achieved commercial operations in the United States from 2007 to 2016. This fleet of projects contributed more than 50% of all solar electricity generated in the United States in 2017. Using detailed information on individual project characteristics, in conjunction with modeled irradiance data, we assess the extent to which actual first-year performance has lived up to both modeled and stated expectations. We then analyze system-level performance degradation in subsequent years by employing a “fixed effects” regression model to statistically isolate the impact of age on system performance. We find that this fleet of utility-scale PV projects has generally lived up to ex ante expectations for first-year performance but that subsequent system-level degradation—found to be −1.3%/year (±0.2%)—has, on average, been worse than both ex ante expectations (commonly −0.5%/year) and results from past studies (ranging from −0.8%/year to −1.0%/year). We emphasize that −1.3%/year is a system-level estimate that captures more than just module degradation (e.g., including soiling, balance of plant degradation, and downtime for maintenance and/or other events). A side analysis of a variety of project characteristics suggests that system-level degradation rates tend to be of lower magnitude among newer projects and larger projects and at sites with lower long-term average temperatures.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative (March 2020 Methodology Report)

Data for thousands of systems by multiple sources were transmitted to NREL for evaluation. Initial automated data quality assurance (QA) checks identified hundreds of systems (QA Tier 1) with high-quality meteorological and AC production data and hundreds of QA Tier 2 systems with adequate data quality. A standard RdTools analysis was conducted for these systems, evaluating performance loss on an annualized basis. To date with the systems evaluated so far, we find a median performance loss rate (aka Rd or degradation rates) for the entire fleet of -0.72%/year based on individual inverter data, which is in line with historical degradation rates previously published for modules and systems (-0.5% to -0.9% / yr, Jordan et al. 2016). A fleet-scale distribution based on revenue-grade meter data rather than inverter AC (alternating current) data yields a slightly different result. We are working to understand the difference between this result and the inverter-based result of -0.72%/year.

14 SOLAR ENERGY↗

A Review of Recent Thermophotovoltaic Energy Conversion Technology Development at NASA Lewis Research Center

NASA Lewis Research Center (LeRC) has had an ongoing research program in TPV since the late 1980's. This effort has included both in-house research programs on critical components such as photovoltaic cells (PV) and emitter materials, as well as an active contracting effort directed toward system, and component development. Of particular note is the in-house development of thin film selective emitters fabricated from rare-earth yttrium aluminum garnets (YAG). Also developed at LeRC is a Monolithic Interconnect Module (MIM) consisting of many small InGaAs cells series interconnected on a single InP substrate. An infrared reflector placed on the rear surface of the substrate returns unabsorbed photons to the emitter for recycling. The current contracted efforts include two TPV system developments by Tecogen, Inc., a solar powered TPV system development, a GaInAsSb cell development and several emitter development efforts (plasma-sprayed selective emitters, flexible SiC and a selective emitting light pipe).

Wilt, David M.↗

Assessing Machine Learning as a Tool to Explain Variance in Deployed Photovoltaic (PV) System Degradation

Degradation remains a large uncertainty in forecasting production for PV plants, creating significant risk for developers and financiers. This study aims to quantify the distribution and drivers of degradation across 10,000 PV systems deployed for distributed or utility generation by training a machine learning model to predict year-over-year degradation rates from metadata characteristics. A combination of K-Means clustering and random forest regressor were found to associate multiple metadata features as potential drivers of degradation, including module characteristics, system design, and climate features. From this, it is inferred that if machine learning is able to find complex patterns between metadata features and system performance loss, such methods can be employed to help developers and financiers make data-informed decisions when estimating long-term energy production forecasts in financial models.

Dunn, Jimmy C.↗

International Photovoltaic Modeling Intercomparison [Slides]

Irradiance transposition models seem to perform well, except the Isotropic with -11.25 W/m 2 underestimation. Most temperature models could not capture behavior when ΔΤ between module and ambient is negative. Uncertainties due to derate factors: modelers overbudgeted resulting in significant power underestimation; maybe ~10% is appropriate for commercial systems but not lab-scale? Most software and models cluster together showing good reproducibility among participants. Modeler’s skills seem to be more important than the PV model itself (flat efficiency with irradiance, positive power temperature coefficients, etc.). Results and best practices will be communicated in a journal article.

14 SOLAR ENERGY↗

Silicon-sheet and thin-film cell and module technology potential: Issue study

The development of high-efficiency low-cost crystalline silicon ribbon and thih-film solar cells for the energy national photovoltaics program was examined. The findings of an issue study conducted are presented. The collected data identified the status of the technology, future research needs, and problems experienced. The potentials of present research activities to meet the Federal/industry long-term technical goal of achieving 15 cents per kilowatt-hour levelized PV energy cost are assessed. Recommendations for future research needs related to crystalline silicon ribbon and thin-film technologies for flat-plate collectors are also included.

Shimada, K.↗

Component-based SHGC determination of BIPV glazing for product comparison

Building-integrated photovoltaic (BIPV) systems are intrinsically designed to generate electricity and to provide at least one building-related function. When BIPV modules act as glazing products in windows, skylights or curtain walls, their ability to control the transmission of solar energy into the building must be characterised by a Solar Heat Gain Coefficient (SHGC) or g value (also known as Total Solar Energy Transmittance – TSET – or “solar factor”). For the comparison of BIPV glazing products consisting of one PV laminate and possibly further, conventional glazing layers separated by gas-filled cavities, the procedures documented in international standards for architectural glazing (e.g. ISO 9050 and EN 410) form a suitable starting point. Easily implemented modifications to these procedures are proposed to take both optical inhomogeneity (if relevant) and extraction of electricity from BIPV glazing units into account. Geometrically complex glazing and shading devices, and light-scattering glazing layers, are outside the scope of the proposed methodology; SHGC determination for obliquely incident solar radiation is also excluded. For these cases, the experimental calorimetric approach documented in [ISO 19467:2017; ISO 19467-2:2021] is recommended. The paper also presents results and conclusions from an implementation exercise and sensitivity study carried out by participants of the IEA-PVPS Task 15 on BIPV. The cell coverage ratio in the PV laminate, the thermal resistance offered by the glazing configuration, the choice of boundary conditions and the effect of extracting electricity were all identified as parameters which significantly affect the SHGC value determined for a given type of BIPV glazing. A practicable approach to accommodate the great variety of dimensions typical for BIPV glazing is also proposed. These findings should pave the way for modifying the existing component-based standards for architectural glazing to take the specific features of BIPV glazing into account.

14 SOLAR ENERGY↗

Photovoltaic stand-alone modular systems, phase 2

The final hardware and system qualification phase of a two part stand-alone photovoltaic (PV) system development is covered. The final design incorporated modular, power blocks capable of expanding incrementally from 320 watts to twenty kilowatts (PK). The basic power unit (PU) was nominally rated 1.28 kWp. The controls units, power collection buses and main lugs, electrical protection subsystems, power switching, and load management circuits are housed in a common control enclosure. Photo-voltaic modules are electrically connected in a horizontal daisy-chain method via Amp Solarlok plugs mating with compatible connectors installed on the back side of each photovoltaic module. A pair of channel rails accommodate the mounting of the modules into a frameless panel support structure. Foundations are of a unique planter (tub-like) configuration to allow for world-wide deployment without restriction as to types of soil. One battery string capable of supplying approximately 240 ampere hours nominal of carryover power is specified for each basic power unit. Load prioritization and shedding circuits are included to protect critical loads and selectively shed and defer lower priority or noncritical power demands. The baseline system, operating at approximately 2 1/2 PUs (3.2 kW pk.) was installed and deployed. Qualification was successfully complete in March 1983; since that time, the demonstration system has logged approximately 3000 hours of continuous operation under load without major incident.

Naff, G. J.↗

Nafion Passivation of c-Si Surface and Edge for Electron Paramagnetic Resonance

Effective surface passivation of crystalline silicon (c-Si) surface by reducing the carrier recombination rate has led to modern c-Si solar cells with efficiencies > 25% in both laboratory and industrial settings. Typical mainstream surface passivation techniques include high-temperature silicon oxide (SiOx), amorphous silicon (a-Si:H), hydrogen-rich silicon nitride (SiNx), and aluminum oxide (Al2O3) [1]. They have demonstrated excellent surface recombination velocity of < 1 cm/s owing to both chemical passivation (via the hydrogen saturation of Si dangling bonds at the c-Si surface), and field-effect passivation (via the band bending from the fixed charge of the dielectric layers). Recently, several groups have studied solution-based organic materials for c-Si passivation, including bis(trifluoromethane)sulfonimide (TFSI), polystyrenesulfonate, and Nafion [2, 3] via spin or dip coating. All films were processed at ambient room temperature, and a high lifetime of 12 ms, as well as a low saturation current density (J0) of 16 fA/cm2, have been demonstrated using Nafion passivation [2]. However, despite the air instability, Nafion has several advantages when introduced to PV applications: (a) Wafer quality can be measured at high throughput after several process stages. (b) It is compatible with PL mapping, compared to HF liquid passivation which cannot be performed in room ambient. (c) Nafion process is fast and poses fewer constraints on process complexity, and cleanness, compared to Al2O3 and a-Si:H passivation. (d) Nafion is the ideal room temperature passivation, which can be applied onto a small fragment of a degraded module to investigate microscopic mechanisms when studying degradation mechanisms. Edge passivation is needed for advanced characterization tests such as Electron Paramagnetic Resonance (EPR), Electrically Detected Magnetic Resonance (EDMR), Deep Level Transient Spectroscopy (DLTS), local cell current-voltage (J-V), and Suns-Voc. In such cases, the laser-damaged minicell edges will obscure the true degradation mechanisms, and Nafion can effectively passivate them without causing further degradation through elevated-temperature processes. In this contribution, we show the passivation results of Nafion on bare nCz and compare it with a Al2O3 witness. We highlight the importance of edge pre-treatment before Nafion to achieve good passivation. We show that Nafion can reach decent passivation without undergoing high-temperature processes. We also explore the temperature dependency of Nafion through photoluminescence (PL) study and demonstrate the application of Nafion under cryogenic temperature (~6 K) through EPR. Our results reveal that Nafion can reduce surface and edge Si dangling bonds at low temperatures. Thus, it can be used as an effective room temperature passivation technique for advanced characterization methods.

c-Si↗

Creating a Universal PV Plug and Socket Standard

Photovoltaic connectors are designed to be quick and easy to install. Current connector qualification standards, such as UL 6703 and IEC 62852, are only intended to evaluate connectors from the same manufacturer and were recently changed to explicitly proscribe the mating of connectors from different manufacturers. Unfortunately, the industry has chosen to design connectors that will commonly connect together with those from other manufacturers. This is done to simplify installation avoiding the situations such as when the connectors on a microinverter, or other module level power electronics, do not match the connectors on the modules in the system. This rampant violation of electrical codes worldwide indicates that there is a strong desire and need to develop a universal connector standard. Here we present the initial approach and philosophy behind the formation of an IEC subgroup under TC82 WG2 looking at this problem. We intend to develop a standard where the materials and geometry of construction are specified to ensure compatibility and the design is intended to be of the highest quality. We expect that this connector will be more costly but especially in rooftop installations where power electronics requires matching components from several manufacturers, that this may still result in a net cost savings. These connectors must be of the highest quality because we wouldn’t want to develop a connector that precluded the manufacturing of a higher quality product, and because these will most commonly be used on rooftop installations where safety is more of a concern. Additionally, because we do not know which brands of connectors will be used together, we cannot simply rely on test results to ensure safety but must create a design that is as inherently safe as possible.

connectors↗

Photovoltaic fleet degradation insights

Abstract In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m 2 . Causes for this technology‐dependent behavior are under investigation.

14 SOLAR ENERGY↗