Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Propellant saturation test, 2 February - 3 May 1966

The objective of this test program was to determine the behavior of gas-saturated water and nitrogen tetroxide under various flow and pressure drop conditions. A second part of the test program is to be conducted at a later time to determine the rate of gas diffusion into propellants. The test program was conducted by the Fluid Systems Test Section of the Thermochemical Test Branch for the Auxiliary Propulsion and Pyrotechnics Branch, Propulsion and Power Division. Testing was accomplished at the Fluid Systems Test Facility during the period from February 2, 1966, to May 3, 1966.

Nitrogen compound↗

Airflow Simulations around OA Intake Louver with Electronic Velocity Sensors

It is important to control outdoor airflow rates into HVAC systems in terms of energy conservation and healthy indoor environment. Technologies are being developed to measure outdoor air (OA) flow rates through OA intake louvers on a real time basis. The purpose of this paper is to investigate the airflow characteristics through an OA intake louver numerically in order to provide suggestions for sensor installations. Airflow patterns are simulated with and without electronic air velocity sensors within cylindrical probes installed between louver blades or at the downstream face of the louver. Numerical results show quite good agreements with experimental data, and provide insights regarding measurement system design. The simulations indicate that velocity profiles are more spatially uniform at the louver outlet relative to between louver blades, that pressure drops imposed by the sensor bars are smaller with sensor bars at the louver outlet, and that placement of the sensor bars between louver blades substantially increases air velocities inside the louver. These findings suggest there is an advantage to placing the sensor bars at the louver outlet face.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A fully integrated 3D CFD model of the flow and heat transfer in a packed bed reactor - 18578

The physical phenomena associated with the modes of heat transfer within a packed pebble bed can be modelled by explicitly solving the associated partial differential equations using a finite volume method approach. Convection from the spheres to coolant, conduction inside and between spheres as well as radiation between various components of a packed bed reactor are the main modes of heat transfer, with several lesser, albeit contributing, phenomena also present. Advances both in software and computing power allow for a larger portion of a packed bed to be modeled with greater accuracy by integrating all applicable physics models in one simulation. A representative unstructured packed bed of uniform spheres was generated with a discrete element method (DEM) and the flow domain modelled using the CFD software package Star-CCM+, taking into account all primary modes of heat transfer as well as a user-specified approach to take secondary effects into account. Effects in the bulk, near-wall and wall-contact regions were investigated. By using such a fully integrated explicit model, a deeper understanding can be can be gained into the role of the underlying phenomena and their respective contributions to the overall heat transfer process. Fuel spheres were modeled explicitly with the conduction between spheres, bed and reflectors being prescribed by contact heat transfer theory as a function of temperature and compressive forces within the bed. The effective thermal conductivity (k{sub eff}), flow pressure drop, as well as temperature distributions in the spheres and coolant were calculated and compared with experimental results from published literature. Good agreement was found with experimental results and the significant contribution of radiation as well as inter-pebble conduction to the effective thermal conductivity could be observed from the results. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An experimental study of the flow and heat transfer between enhanced heat transfer plates for PHEs

The flow and heat transfer between inclined discrete rib plates for plate heat exchangers have been experimentally studied. Dye injection method is used to visualize the flow structures. The visualization results show that front vortex, rear vortex and main vortex are formed between the plates. The rib parameter influence is also studied using visualization method. The pressure drop and heat transfer between the inclined discrete rib plates as well as that between inclined continuous rib plates and smooth plates are also measured. The measured results show that the inclined discrete rib plate can enhanced heat transfer 20-25% at the same pumping power compared with the commonly used inclined continuous rib plates. (author)

42 ENGINEERING↗

GEOMETRY, HEAT REMOVAL AND KINETICS SCOPING MODELS FOR HYDROGEN STORAGE SYSTEMS

It is recognized that detailed models of proposed hydrogen storage systems are essential to gain insight into the complex processes occurring during the charging and discharging processes. Such insight is an invaluable asset for both assessing the viability of a particular system and/or for improving its design. The detailed models, however, require time to develop and run. Clearly, it is much more efficient to begin a modeling effort with a good system design and to progress from that point. To facilitate this approach, it is useful to have simplified models that can quickly estimate optimal loading and discharge kinetics, effective hydrogen capacities, system dimensions and heat removal requirements. Parameters obtained from these models can then be input to the detailed models to obtain an accurate assessment of system performance that includes more complete integration of the physical processes. This report describes three scoping models that assess preliminary system design prior to invoking a more detailed finite element analysis. The three models address the kinetics, the scaling and heat removal parameters of the system, respectively. The kinetics model is used to evaluate the effect of temperature and hydrogen pressure on the loading and discharge kinetics. As part of the kinetics calculations, the model also determines the mass of stored hydrogen per mass of hydride (in a particular reference form). As such, the model can determine the optimal loading and discharge rates for a particular hydride and the maximum achievable loading (over an infinite period of time). The kinetics model developed with the Mathcad{reg_sign} solver, runs in a mater of seconds and can quickly be used to identify the optimal temperature and pressure for either the loading or discharge processes. The geometry scoping model is used to calculate the size of the system, the optimal placement of heat transfer elements, and the gravimetric and volumetric capacities for a particular geometric configuration and hydride. This scoping model is developed in Microsoft Excel{reg_sign} and inputs the mass of hydrogen to be stored, mass of stored hydrogen to mass of hydride (from the kinetics model), component densities, etc. The heat removal scoping model is used to calculate coolant flowrates, pressure drops and temperature increases over the length of the cooling channels. The model also calculates the convection heat transfer coefficient required to remove the heat of reaction associated with hydrogen uptake. The heat removal model inputs dimensions and the mass of hydrogen to be stored directly from the geometry scoping model. Additionally, the model inputs the heats of reaction, the thermal properties of the coolant and the time required to charge the bed.

08 HYDROGEN↗

Evidence of sublaminar drag naturally occurring in a curved pipe

Steady and unsteady flows in a mildly curved pipe for a wide range of Reynolds numbers are examined with direct numerical simulation. It is shown that in a range of Reynolds numbers in the vicinity of Re{sub b} ≈ 3400, based on bulk velocity and pipe diameter, a marginally turbulent flow is established in which the friction drag naturally reduces below the laminar solution at the same Reynolds number. The obtained values for friction drag for the laminar and turbulent (sublaminar) flows turn out to be in excellent agreement with experimental measurements in the literature. Our results are also in agreement with Fukagata et al. [“On the lower bound of net driving power in controlled duct flows,” Phys. D 238, 1082 (2009)], as the lower bound of net power required to drive the flow, i.e., the pressure drop of the Stokes solution, is still lower than our marginally turbulent flow. A large-scale traveling structure that is thought to be responsible for that behaviour is identified in the instantaneous field. This mode could also be extracted using proper orthogonal decomposition. The effect of this mode is to redistribute the mean flow in the circular cross section which leads to lower gradients at the wall compared to the laminar flow.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Loading and Regeneration Analysis of a Diesel Particulate Filter with a Radio Frequency-Based Sensor

Accurate knowledge of diesel particulate filter (DPF) loading is critical for robust and efficient operation of the combined engine-exhaust aftertreatment system. Furthermore, upcoming on-board diagnostics regulations require on-board technologies to evaluate the status of the DPF. This work describes the application of radio frequency (RF) based sensing techniques to accurately measure DPF soot levels and the spatial distribution of the accumulated material. A 1.9L GM turbo diesel engine and a DPF with an RF-sensor were studied. Direct comparisons between the RF measurement and conventional pressure-based methods were made. Further analysis of the particulate matter loading rates was obtained with a mass-based soot emission measurement instrument (TEOM). Comparison with pressure drop measurements show the RF technique is unaffected by exhaust flow variations and exhibits a high degree of sensitivity to DPF soot loading and good dynamic response. Additional computational and experimental work further illustrates the spatial resolution of the RF measurements. Based on the experimental results, the RF technique shows significant promise for improving DPF control enabling optimization of the combined engine-aftertreatment system for improved fuel economy and extended DPF service life.

33 ADVANCED PROPULSION SYSTEMS↗

CFD-Informed Spacer Grid Models in the Subchannel Code CTF

Data from computational fluid dynamics (CFD) simulations can be utilized to improve the predictive capabilities of the subchannel code CTF. Past work incorporating CFD results into CTF has included accounting for directed crossflow and turbulent mixing between adjacent subchannels. Spacer grids impact fluid flow in various ways, and this work focuses on four spacer grid effects, namely: 1. Directed crossflow; 2. Turbulent mixing; 3. Enhanced downstream heat transfer; 4. Pressure drop correlation. Heat transfer augmentation occurs partially due to the disturbances in the developed flow and from the additional turbulence generated by the presence of obstructions in the fluid flow's path. The boundary layer disruption is caused in part by the newly-directed flow just downstream of the spacer grid vanes. This effect lessens as the distance from the grid increases and the flow returns to its developed state, closer to what would be expected in a bare subchannel. Current plans of this work are to develop a method for incorporating the effects of spacer grids on the heat transfer calculation within CTF. Proposed techniques include the addition of an enhancement factor to the local heat transfer coefficient. The inclusion of CFD data from properly-designed simulations will allow CTF to better predict parameters such as fluid temperatures near spacer grids. Improved pressure loss coefficients for each grid can also be generated using CFD simulations. The heat transfer modification has been studied, with other authors noting correlations which are dependent on grid properties such as the blockage ratio. Parameters considered in this study are the turbulent kinetic energy (TKE) and vorticity. There are currently no models to calculate or store either of these parameters within CTF. When accounting for spacer grid effects in CTF, it is important to not double-count the effects towards two different CTF models. This requires carefully designing CFD simulations around capturing specific phenomena from the grids and being able to apply these CFD results to all appropriate flow conditions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modelling of the Nuclear Propulsion Rocket

Nuclear power propulsion rockets are used for the long distance missions in space. National Aeronautical and Space Administration (NASA) has developed several nuclear propulsion rockets since 1950. Especially Nuclear Engine for Rocket Vehicle Application (NERVA) program focused on long term missions in NASA. Planned/unplanned transients on nuclear thermal rockets have to be investigated for these rockets to be sure that they can be utilized for long term missions. This work demonstrates the modelling of nuclear propulsion rocket. By using this new model based on RELAP5 system code, corrosion induced blockages on radiation heat transfer has been investigated for the Pewee I rocket. The blockage locations in the coolant system have been defined based on the experimental data which is available in the literature to use in the computational models. To capture the 3 dimensional (3D) heat transfer modes in the reactor core of Pewee I, a detailed 3D system model has been developed to identify specifically the effect of corrosion on the radiation heat transfer. It was concluded that the pressure drop across the peripheral fuel element coolant holes was also larger than other channels. In addition, it was noticed that radiation heat transfer rate for the channels undergoing blockages increases when the radiation heat transfer rate in their neighbor channels decrease. The temperature of the peripheral fuel elements will gradually get closer to the melting point of Uranium Carbide, especially when the coolant channels undergo the most severe blockage.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary engineering design of sodium-cooled CANDLE core

The CANDLE burning process is characterized by the autonomous shifting of burning region with constant reactivity and constant spacial power distribution. Evaluations of such critical burning process by using widely used neutron diffusion and burning codes under some realistic engineering constraints are valuable to confirm the technical feasibility of the CANDLE concept and to put the idea into concrete core design. In the first part of this paper, it is discussed that whether the sustainable and stable CANDLE burning process can be reproduced even by using conventional core analysis tools such as SLAROM and CITATION-FBR. As a result, it is certainly possible to demonstrate it if the proper core configuration and initial fuel composition required as CANDLE core are applied to the analysis. In the latter part, an example of a concrete image of sodium cooled, metal fuel, 2000MWt rating CANDLE core has been presented by assuming an emerging inevitable technology of recladding. The core satisfies engineering design criteria including cladding temperature, pressure drop, linear heat rate, and cumulative damage fraction (CDF) of cladding, fast neutron fluence and sodium void reactivity which are defined in the Japanese FBR design project. It can be concluded that it is feasible to design CANDLE core by using conventional codes while satisfying some realistic engineering design constraints assuming that recladding at certain time interval is technically feasible.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Systems Modeling of Chemical Hydride Hydrogen Storage Materials for Fuel Cell Applications

A fixed bed reactor was designed, modeled and simulated for hydrogen storage on-board the vehicle for PEM fuel cell applications. Ammonia Borane (AB) was selected by DOE's Hydrogen Storage Engineering Center of Excellence (HSECoE) as the initial chemical hydride of study because of its high hydrogen storage capacity (up to {approx}16% by weight for the release of {approx}2.5 molar equivalents of hydrogen gas) and its stability under typical ambient conditions. The design evaluated consisted of a tank with 8 thermally isolated sections in which H2 flows freely between sections to provide ballast. Heating elements are used to initiate reactions in each section when pressure drops below a specified level in the tank. Reactor models in Excel and COMSOL were developed to demonstrate the proof-of-concept, which was then used to develop systems models in Matlab/Simulink. Experiments and drive cycle simulations showed that the storage system meets thirteen 2010 DOE targets in entirety and the remaining four at greater than 60% of the target.

08 HYDROGEN↗

Implications of Low Particulate Matter Emissions on System Fuel Efficiency for High Efficiency Clean Combustion

Advanced diesel combustion regimes such as High Efficiency Clean Combustion (HECC) offer the benefits of reduced engine out NOX and particulate matter (PM) emissions. Lower PM emissions during advanced combustion reduce the demand on diesel particulate filters (DPFs) and can, thereby, reduce the fuel penalty associated with DPF regeneration. In this study, a SiC DPF was loaded and regenerated on a 1.7-liter 4-cylinder diesel engine operated in conventional and advanced combustion modes at different speed and load conditions. A diesel oxidation catalyst (DOC) and a lean NOX trap (LNT) were also installed in the exhaust stream. Five steady-state speed and load conditions were weighted to estimate Federal Test Procedure (FTP) fuel efficiency. The DPF was loaded using lean-rich cycling with frequencies that resulted in similar levels of NOX emissions downstream of the LNT. The pressure drop across the DPF was measured at a standard point (1500 rpm, 5.0 bar) before and after loading, and a P rise rate was determined for comparison between conventional and advanced combustion modes. Higher PM emissions in conventional combustion resulted in a higher rate of backpressure rise across the DPF at all of the load points leading to more frequent DPF regenerations and higher fuel penalty. The fuel penalty during conventional combustion was 4.2% compared with 3.1% for a mixture of conventional and advanced modes.

33 ADVANCED PROPULSION SYSTEMS↗

Effect of Mach number on the efficiency of microwave energy deposition in supersonic flow

The article is devoted to experimental and numerical studies of the efficiency of microwave energy deposition into a supersonic flow around the blunt cylinder at different Mach numbers. Identical conditions for energy deposition have been kept in the experiments, thus allowing to evaluate the pure effect of varying Mach number on the pressure drop. Euler equations are solved numerically to model the corresponding unsteady flow compressed gas. The results of numerical simulations are compared to the data obtained from the physical experiments. It is shown that the momentum, which the body receives during interaction of the gas domain modified by microwave discharge with a shock layer before the body, increases almost linearly with rising of Mach number and the efficiency of energy deposition also rises.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adsorption Model for Off-Gas Separation

The absence of industrial scale nuclear fuel reprocessing in the U.S. has precluded the necessary driver for developing the advanced simulation capability now prevalent in so many other countries. Thus, it is essential to model complex series of unit operations to simulate, understand, and predict inherent transient behavior and feedback loops. A capability of accurately simulating the dynamic behavior of advanced fuel cycle separation processes will provide substantial cost savings and many technical benefits. The specific fuel cycle separation process discussed in this report is the off-gas treatment system. The off-gas separation consists of a series of scrubbers and adsorption beds to capture constituents of interest. Dynamic models are being developed to simulate each unit operation involved so each unit operation can be used as a stand-alone model and in series with multiple others. Currently, an adsorption model has been developed in gPROMS software. Inputs include gas stream constituents, sorbent, and column properties, equilibrium and kinetic data, and inlet conditions. It models dispersed plug flow in a packed bed under non-isothermal and non-isobaric conditions for a multiple component gas stream. The simulation outputs component concentrations along the column length as a function of time from which the breakthrough data is obtained. It also outputs temperature along the column length as a function of time and pressure drop along the column length. Experimental data will be input into the adsorption model to develop a model specific for iodine adsorption on silver mordenite as well as model(s) specific for krypton and xenon adsorption. The model will be validated with experimental breakthrough curves. Another future off-gas modeling goal is to develop a model for the unit operation absorption. The off-gas models will be made available via the server or web for evaluation by customers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bed inventory overturn in a circulating fluid bed riser with pant-leg structure

The special phenomenon, nominated as bed inventory overturn, in circulating fluid bed (CFB) riser with pant-leg structure was studied with model calculation and experimental work. A compounded pressure drop mathematic model was developed and validated with the experimental data in a cold experimental test rig. The model calculation results agree well with the measured data. In addition, the intensity of bed inventory overturn is directly proportional to the fluidizing velocity and is inversely proportional to the branch point height. The results in the present study provide significant information for the design and operation of a CFB boiler with pant-leg structure. 15 refs., 10 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Ultra high pressure liquid chromatography column permeability and changes of the eluent properties

The behavior of four similar liquid chromatography columns (2.1 mm i.d. x30, 50, 100, and 150 mm, all packed with fine particles, average d{sub p} {approx} 1.7 {micro}m, of bridged ethylsiloxane/silica hybrid-C{sub 18}, named BEH-C{sub 18}) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of C in still air and C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144 {+-} 3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured {Delta}T = 25-30 K, ({Delta}{eta}/{eta}) {approx_equal} 100%, and ({Delta}{rho}/{rho}) {approx_equal} 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in UPLC is discussed.

36 MATERIALS SCIENCE↗

Investigation of similarity metrics for simulation based scaling analysis

Scaling analysis is a technique for characterizing degree of similarity between processes to occur in a real prototypic system and those to occur in its reduced scale (experimental) analog. In the context of nuclear reactor thermal-hydraulics and safety, scaling analysis is instrumental in assessing the applicability of data obtained from a scaled test facility for calibration of models and validation of simulation codes. Quantification of scale-related distortions is the key element in scaling analysis. In this work, we examine an approach for scaling analysis using computer simulation codes. Similarity analysis using information-theoretic approach is performed by comparing performance of experiment and application to variation of system conditions. Three different information theoretic measures namely mutual information, Kullback-Leibler divergence and overlap coefficient are selected for their potential use as metric for similarity analysis. We test the metrics by comparing them against physics-based scaling ratios, which are well known in fundamental thermal-hydraulic processes. In this exploratory analysis, a case of pressure drop of a steady-state flow through a channel is employed to test the proposed approach. It was found that in the absence of model uncertainties, mutual information serve as an effective measure of the scale effects present in the experiment. However, model uncertainty can significantly impact the quality of similarity analysis. Our analysis indicates that model uncertainties can have significant impact on the information theoretic metrics used for scaling analysis. Furthermore, if the model uncertainties exceeds beyond a critical value, the scale effect present in the experiment cannot be adequately evaluated. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transient PVT measurements and model predictions for vessel heat transfer. Part II.

Part I of this report focused on the acquisition and presentation of transient PVT data sets that can be used to validate gas transfer models. Here in Part II we focus primarily on describing models and validating these models using the data sets. Our models are intended to describe the high speed transport of compressible gases in arbitrary arrangements of vessels, tubing, valving and flow branches. Our models fall into three categories: (1) network flow models in which flow paths are modeled as one-dimensional flow and vessels are modeled as single control volumes, (2) CFD (Computational Fluid Dynamics) models in which flow in and between vessels is modeled in three dimensions and (3) coupled network/CFD models in which vessels are modeled using CFD and flows between vessels are modeled using a network flow code. In our work we utilized NETFLOW as our network flow code and FUEGO for our CFD code. Since network flow models lack three-dimensional resolution, correlations for heat transfer and tube frictional pressure drop are required to resolve important physics not being captured by the model. Here we describe how vessel heat transfer correlations were improved using the data and present direct model-data comparisons for all tests documented in Part I. Our results show that our network flow models have been substantially improved. The CFD modeling presented here describes the complex nature of vessel heat transfer and for the first time demonstrates that flow and heat transfer in vessels can be modeled directly without the need for correlations.

42 ENGINEERING↗