Thermal storage requirements for parabolic dish solar power plants

The cost effectiveness of a high temperature thermal storage system is investigated for a representative parabolic dish solar power plant. The plant supplies electrical power in accordance with a specific, seasonally varying demand profile. The solar power received by the plant is supplemented by power from fuel combustion. The cost of electricity generated by the solar power plant is calculated, using the cost of mass-producible subsystems (specifically, parabolic dishes, receivers, and power conversion units) now being designed for this type of solar plant. The trade-off between fuel and thermal storage is derived in terms of storage effectiveness, the cost of storage devices, and the cost of fuel. Thermal storage requirements, such as storage capacity, storage effectiveness, and storage cost are established based on the cost of fuel and the overall objective of minimizing the cost of the electricity produced by the system. As the cost of fuel increases at a rate faster than general inflation, thermal storage systems in the $40 to $70/kWthr range could become cost effective in the near future.

Wen, L.↗

High discharge rate characteristics of nickel-cadmium batteries for pulse load filtering

Several tests of specially fabricated nickel-cadmium batteries having circular disk type electrodes were considered. These batteries were evaluated as filter elements between a constant current power supply and a five hertz pulsed load demanding approximately twice the power supply current during the load on portion of the cycle. Short tests lasting 10,000 cycles were conducted at up to a 21 C rate and an equivalent energy density of over 40 Joules per pound. In addition, two batteries were subjected to 10 to the 7 charge/discharge cycles, one at a 6.5 C rate and the other at a 13 C rate. Assuming an electrode to battery weight ratio of 0.5, these tests represent an energy density of about 7 and 14 Joules per pound respectively. Energy density, efficiency, capacitance, average voltage, and available capacity were tracked during these tests. After 10 to the 7 cycles, capacity degradation was negligible for one battery and about 20% for the other. Cadmium electrode failure may be the factor limiting lifetime at extremely low depth of discharge cycling. The output was examined and a simple equivalent circuit was proposed.

Gearing, G. M.↗

CLIC RF High Power Production Testing Program

The CLIC Power Extraction and Transfer Structure (PETS) is a passive microwave device in which bunches of the drive beam interact with the impedance of the periodically loaded waveguide and generate RF power for the main linac accelerating structure. The demands on the high power production ({approx} 150 MW) and the needs to transport the 100 A drive beam for about 1 km without losses, makes the PETS design rather unique and the operation very challenging. In the coming year, an intense PETS testing program will be implemented. The target is to demonstrate the full performance of the PETS operation. The testing program overview and test results available to date are presented.

43 PARTICLE ACCELERATORS↗

Backup power or bill savings? How electricity tariffs impact residential solar-plus-storage usage in the United States

Adoption of paired solar-plus-storage systems has accelerated in recent years, driven by both the demand for backup power and a desire to manage utility bills. Tradeoffs between those two uses can arise through the reserve setting on the battery storage system, which serves to maintain a minimum state of charge in case of a power interruption. Our paper applies an economic framework to evaluate this tradeoff in terms of changes in bill savings and customer reliability value across reserve levels, considering how those tradeoffs depend on the underlying electricity rate structure and levels. The analysis is based on a representative set of load profiles, solar profiles, tariff designs, and stochastic power interruption events across ten different regions in the United States. We find that the opportunity cost of holding storage capacity in reserve, in terms of foregone bill reductions, outweighs any gains in reliability value from mitigated power interruptions in the majority of customer situations. Higher storage reserve levels increase total customer value only in specific circumstances, such as for customers with inferior reliability (10x average interruptions), with a very high value of lost load ($50/kWh), and with tariff or interconnection rules that disallow grid charging. However, even this result is dampened when considering tariff designs with higher price differentials that increase the opportunity cost of holding storage in reserve (e.g. import/export or time-of-use rates). Allowing grid charging in tariffs essentially eliminates the necessity to hold any storage in reserve in all sensitivity cases explored.

Electric resilience↗

Ten questions concerning reinforcement learning for building energy management

As buildings account for approximately 40% of global energy consumption and associated greenhouse gas emissions, their role in decarbonizing the power grid is crucial. The increased integration of variable energy sources, such as renewables, introduces uncertainties and unprecedented flexibilities, necessitating buildings to adapt their energy demand to enhance grid resiliency. Consequently, buildings must transition from passive energy consumers to active grid assets, providing demand flexibility and energy elasticity while maintaining occupant comfort and health. This fundamental shift demands advanced optimal control methods to manage escalating energy demand and avert power outages. Reinforcement learning (RL) emerges as a promising method to address these challenges. Here, in this paper, we explore ten questions related to the application of RL in buildings, specifically targeting flexible energy management. We consider the growing availability of data, advancements in machine learning algorithms, open-source tools, and the practical deployment aspects associated with software and hardware requirements. Our objective is to deliver a comprehensive introduction to RL, present an overview of existing research and accomplishments, underscore the challenges and opportunities, and propose potential future research directions to expedite the adoption of RL for building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Materials for Power Transmission in Extreme Environments

NASA’s goal for a sustained human presence on the Moon and a future Lunar economy requires the development of novel power transmission materials for extreme environments. As an increasing number of public and private entities set their sights towards a future on the Moon, the demand for surface power will dramatically increase – potentially up to megawatt levels. A Lunar economy is envisioned to include a human habitat, manned and unmanned science exploration assets, excavation rovers and systems, and large-scale infrastructure construction such as solar arrays and power grids. A NASA trade study estimated that 1 to 3 km of power transmission lines (1 to 3 KV ac and dc) will be needed over time. Current high power and voltage SOA cables/wire can easily exceed 1 kg/m where mass is not as critical. Connectors, deployment spools and robots further increase the subsystem mass significantly increasing costs. On the other hand, advances in aeronautics provides path towards space missions. The operating environment on the Moon presents substantial risk to safe and reliable power transmission due to space weathering and degradation. These challenges include cosmic and UV radiation, extreme temperatures swings, the electrostatic Lunar exosphere, and the electrostatic and abrasive lunar regolith. The critical need for lightweight, safe and reliable power cables/wires materials is evident. In this presentation, the extreme high altitude and lunar environments and recent materials development from NASA Glenn Research Center’s High Voltage Materials team towards meeting NASA’s objectives and goals for aeronautics and space missions.

Cu/CNT conductors↗

Coordinated operation of pumped-storage hydropower with power and water distribution systems

Small pumped-storage hydropower (PSH) units have gained popularity as distributed energy storage options that can provide flexibility to the operation of power distribution systems. Optimal operation of small PSH units is not only dependent on the energy storage provided to power distribution system, but also on the inflow and outflow of water from and to the water distribution system. Here, in this context, this paper develops an optimization model for coordinated operation of PSH units with power and water distribution systems. The proposed model optimizes the operation of water tanks, variable-speed pumps and PSH in pumping and generating modes to minimize the operation cost of power distribution system, while respecting the power flow constraints of power distribution and hydraulic constraints of water distribution system. Appropriate electricity tariffs are implemented to avoid additional expenses in water distribution system that can be enforced by its coordinated operation in favor of power distribution system. The proposed model is implemented on a 33-bus and a 123-bus test power distribution system connected to a 16-node test water distribution system. Results demonstrate the effectiveness of proposed model in tapping PSH flexibility to reduce the operation cost of power and water distribution systems, while meeting the power and water demands.

13 HYDRO ENERGY↗

Efficient Customer Selection for Sustainable Demand Response in Smart Grids

Regulating the power consumption to avoid peaks in demand is a common practice. Demand Response(DR) is being used by utility providers to minimize costs or ensure system reliability. Although it has been used extensively there is a shortage of solutions dealing with dynamic DR. Past attempts focus on minimizing the load demand without considering the sustainability of the reduced energy. In this paper an efficient algorithm is presented which solves the problem of dynamic DR scheduling. Data from the USC campus micro grid were used to evaluate the efficiency as well as the robustness of the proposed solution. The targeted energy reduction is achieved with a maximum average approximation error of ≈ 0.7%. Sustainability of the reduced energy is achieved with respect to the optimal available solution providing a maximum average error less than 0.6%. It is also shown that a solution is provided with a low computational cost fulfilling the requirements of dynamic DR.

change making↗

Sparse Linear Solvers for Large-scale Electromagnetic Transient Simulations

Linear solvers form the basis for electromagnetic transient (EMT) simulations. There is a need to speed up EMT simulations as larger regions are analyzed using EMT simulations. For the same, the performance of linear solvers plays an important role. Exploiting the sparsity of the matrices generated in EMT simulations could assist with speed-up. Scalability is also crucial as power grids expand, demanding solutions capable of accommodating the increasing system size. Recent studies from the North American Electric Reliability Corporation (NERC) increasingly emphasize that EMT simulation models of the power grid will grow larger with the inclusion of power electronics components. Parallelisms in sparsity patterns exploit modern central processing units (CPUs), multi-core CPUs, and graphics processing units (GPUs) architectures in sparse solver designs. Therefore, this paper explores publicly available existing linear solvers and investigates their efficiency in large-scale power grid simulations. A large-scale power grid is developed by increasing the size of the IEEE 39 bus test system to up to 39000 bus systems.

Hsu, Kuan-Chieh↗

Modeling, Analysis, and Control of Demand Response Resources

While the traditional goal of an electric power system has been to control supply to fulfill demand, the demand-side can plan an active role in power systems via Demand Response (DR), defined by the Department of Energy (DOE) as “a tariff or program established to motivate changes in electric use by end-use customers in response to changes in the price of electricity over time, or to give incentive payments designed to induce lower electricity use at times of high market prices or when grid reliability is jeopardized” [29]. DR can provide a variety of benefits including reducing peak electric loads when the power system is stressed and fast timescale energy balancing. Therefore, DR can improve grid reliability and reduce wholesale energy prices and their volatility. This dissertation focuses on analyzing both recent and emerging DR paradigms. Recent DR programs have focused on peak load reduction in commercial buildings and industrial facilities (C&I facilities). We present methods for using 15-minute-interval electric load data, commonly available from C&I facilities, to help building managers understand building energy consumption and ‘ask the right questions’ to discover opportunities for DR. Additionally, we present a regression-based model of whole building electric load, i.e., a baseline model, which allows us to quantify DR performance. We use this baseline model to understand the performance of 38 C&I facilities participating in an automated dynamic pricing DR program in California. In this program, facilities are expected to exhibit the same response each DR event. We find that baseline model error makes it difficult to precisely quantify changes in electricity consumption and understand if C&I facilities exhibit event-to-event variability in their response to DR signals. Therefore, we present a method to compute baseline model error and a metric to determine how much observed DR variability results from baseline model error rather than real variability in response. We find that, in general, baseline model error is large. Though some facilities exhibit real DR variability, most observed variability results from baseline model error. In some cases, however, aggregations of C&I facilities exhibit real DR variability, which could create challenges for power system operation. These results have implications for DR program design and deployment. Emerging DR paradigms focus on faster timescale DR. Here, we investigate methods to coordinate aggregations of residential thermostatically controlled loads (TCLs), including air conditioners and refrigerators, to manage frequency and energy imbalances in power systems. We focus on opportunities to centrally control loads with high accuracy but low requirements for sensing and communications infrastructure. Specifically, we compare cases when measured load state information (e.g., power consumption and temperature) is 1) available in real time; 2) available, but not in real time; and 3) not available. We develop Markov Chain models to describe the temperature state evolution of heterogeneous populations of TCLs, and use Kalman filtering for both state and joint parameter/state estimation. We present a look-ahead proportional controller to broadcast control signals to all TCLs, which always remain in their temperature dead-band. Simulations indicate that it is possible to achieve power tracking RMS errors in the range of 0.26–9.3% of steady state aggregated power consumption. Results depend upon the information available for system identification, state estimation, and control. We find that, depending upon the performance required, TCLs may not need to provide state information to the central controller in real time or at all. We also estimate the size of the TCL potential resource; potential revenue from participation in markets; and break-even costs associated with deploying DR-enabling technologies. We find that current TCL energy storage capacity in California is 8–11 GWh, with refrigerators contributing the most. Annual revenues from participation in regulation vary from $10 to $220 per TCL per year depending upon the type of TCL and climate zone, while load following and arbitrage revenues are more modest at $2 to $35 per TCL per year. These results lead to a number of policy recommendations that will make it easier to engage residential loads in fast timescale DR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New York Solar Smart DG Hub-Resilient Solar Project: Economic and Resiliency Impact of PV and Storage on New York Critical Infrastructure

Resilient PV, which is solar paired with storage ('solar-plus-storage'), provides value both during normal grid operation and power outages as opposed to traditional solar PV, which functions only when the electric grid is operating. During normal grid operations, resilient PV systems help host sites generate revenue and/or reduce electricity bill charges. During grid outages, resilient PV provides critical emergency power that can help people in need and ease demand on emergency fuel supplies. The combination of grid interruptions during recent storms, the proliferation of solar PV, and the growing deployment of battery storage technologies has generated significant interest in using these assets for both economic and resiliency benefits. This report analyzes the technical and economic viability for resilient PV on three critical infrastructure sites in New York City (NYC): a school that is part of a coastal storm shelter system, a fire station, and a NYCHA senior center that serves as a cooling center during heat emergencies. This analysis differs from previous solar-plus-storage studies by placing a monetary value on resiliency and thus, in essence, modeling a new revenue stream for the avoided cost of a power outage. Analysis results show that resilient PV is economically viable for NYC's critical infrastructure and that it may be similarly beneficial to other commercial buildings across the city. This report will help city building owners, managers, and policymakers better understand the economic and resiliency benefits of resilient PV. As NYC fortifies its building stock against future storms of increasing severity, resilient PV can play an important role in disaster response and recovery while also supporting city greenhouse gas emission reduction targets and relieving stress to the electric grid from growing power demands.

14 SOLAR ENERGY↗

PASP: A high voltage array experiment

In the near future, Air Force mission payloads will require significant increases in power. Sophisticated sensing systems such as infrared focal plane detector arrays and radar will be employed by the Air Force to fulfill its strategic objectives. These payloads will demand that the power subsystem provide up to 50 kW at the end of mission life, more than an order of magnitude greater than is currently required. Some of these payloads must be flown in low-Earth polar orbits to satisfy mission objectives, and it is likely that large (500 to 600 sq m) solar photovoltaic arrays will operate in the low-Earth polar environment. The standard 28 volt power subsystem is not weight efficient for the array power levels being considered. The impact of the solar array operating voltage on the total weight of the array and the subsystem power conditioning and distribution components is illustrated. In the interest of reducing power subsystem weight, higher array operating voltages are considered. The problems which the higher array voltage present to the array designer are discussed. In order to provide a maximum return on the tremendous investment of resources required to develop and place these assets in orbit, they must be designed to operate effectively for extended periods of time. To achieve this, the system must be able to function in the threat-induced and natural space environment.

Scott-Monck, J.↗

DS-GL: Advancing Graph Learning via Harnessing the Power of Nature within Dynamic Systems

With the rapid digitization of the world, an increasing number of real-world applications are turning to nonEuclidean data, modeled as graphs. Due to their intrinsic high complexity and irregularity, learning from graph data demands tremendous computational power. Recently, CMOS-compatible Ising machines, i.e., dynamic systems composed of CMOS components, have emerged as a new approach that harnesses the inherent power of natural annealing within dynamic systems to efficiently resolve binary optimization problems and have been adopted for traditional graph computation, such as max-cut. However, when performing complex Graph Learning (GL) tasks, Ising machines face significant hurdles: (i) they are inherently binary and thus ill-suited for real-valued problems; (ii) their expensive all-to-all coupling network that guarantees effective natural annealing poses daunting scalability concerns. To address these challenges, this paper proposes a nature-powered graph learning framework dubbed DS-GL, which is the first effort to transform the process of solving graph learning problems into the natural annealing process within a parameterized dynamic system embodied as a CMOS chip. To tackle the two major hurdles, DS-GL first augments the Ising machine architecture to modify the self-reaction term of its Hamiltonian function from linear to quadratic, effectively serving as an energy regulator. This adjustment maintains the system’s original physical interpretation while enabling it to process continuous, real-valued data. Second, to address the scaling issue, DS-GL further upgrades the real-valued dense Ising machine by decomposing it into a mesh-based multi-PE dynamic system that supports efficient distributed spatial-temporal co-annealing across different PEs through sparse interconnects. By exploiting the inherent sparsity and component structures in real-world graphs, DS-GL is able to map complex graph learning tasks onto the scalable dynamic system while maintaining high accuracy. Evaluations with three diverse GL applications across six real-world datasets, including traffic flow and COVID-19 prediction, show that DS-GL can deliver from 102× to 106× speedups and 500× energy reduction over Graph Neural Networks on GPUs, with 5% - 20% accuracy enhancement.

Song, Ruibing↗

Intelligent load pattern modeling and denoising using improved variational mode decomposition for various calendar periods

This paper proposes a novel approach to identify the load patterns considering calendar impact and denoising process, which advances the state of art of load identification and load forecasting to a more flexible and adaptive extent by revealing the correlation between load profile and the substantial influence factors. With the rapid development and the promising application of energy intemet and grid modernization, the accurate load modeling and forecasting especially by load pattern modeling (LPM) have become more and more critical to observe and estimate load profile so as to optimize the operation efficiency of the power grid. Traditional methods mostly focus on the static LPM itself which are unable to account the non-linear and highly dynamic load fluctuations in order to balance the demand of the power grid during various calendar period (VCP) scheduling. In this paper, a load pattern modeling method for power grid considering the impact of typical calendar effects is proposed using a combination of improved variational mode decomposition (IVMD) and deep belief network (DBN) algorithm. Firstly, an index of load curve curvature (LCC) is proposed to improve the selection of value K in the conventional VMD algorithm. The value K of the intrinsic modality is determined by adopting LCC to better quantify the average instantaneous frequency of the modal decomposition of the VMD and to reduce the elevated stochasticity of k. Secondly, an optimization formulation is developed based on adaptive segmented loop decomposition of the typical correlation coefficient to suppress the edge effect in VMD decomposition, which would enable the reconstructed curve to incorporate the variabilities from the initial data. Finally, the IVMD and DBN algorithms are jointly implemented to optimize the accuracy of VCP load pattern modeling curve regression. Numerical examples have been performed with the results proving that the proposed method significantly outperforms the state-of-art in reducing the modeling error of VCP load curve, improving the overall forecasting accuracy, and reducing load dispatching cost.

deep belief network↗

An economical approach to space power systems

Projected energy demand for all NASA, DoD and civil missions for the time span 1981 to 1995 are illustrated. Typical energy cost range from about $300 to $2000 per kW-hr, with an average of about $800 per kW-hr for long-duration missions. At these levels, the cost of the required energy would be several billion dollars per year by about 1985 and might constrain the number and types of NASA programs to be carried out. NASA is extensively pursuing approaches for reducing nonrecurring costs. Two programs are presented for the development of an economical approach to space power systems. They are: (1) Economical Orbital Power (ECOP) with the objective to demonstrate the applicability of a commercial approach to the development of a low cost photovoltaic space power system; and (2) Space Power Experiment (SPEX) which has the objective to demonstrate the application of industrial hardware for space power systems.

Teren, F.↗

Multicomponent adsorption of radioactive iodine and krypton using ETS-10 supported carbon nano-polyhedrons

Over 13% of the world's energy demand is supplied by nuclear power plants in 31 countries. This demand is growing; by 2030 the IAEA predicts a 100% increase in the demand for nuclear energy. The increase in nuclear energy production imposes a growing strain on the uranium fuel supply. At current consumption rates the world's supply of uranium is projected to last ∼100 years. Following the IAEA's prediction for increased nuclear energy, uranium supplies will dwindle even more quickly. However, this consequence can be limited as ∼95% of uranium is left in used nuclear fuel (UNF). Reprocessing of UNF will utilize this remaining uranium and extend the lifetime of the world's uranium supply. One of the concerns with nuclear reprocessing is that it frees radionuclides created by the fission of uranium to be released into the atmosphere through off-gas. The major constituents of off-gas include: {sup 85}Kr, {sup 129}I, {sup 14}C, {sup 3}H, and various Xe isotopes. {sup 85}Kr and {sup 129}I present the largest threat due to their harmful environmental effects and abundance. They are the most practical contaminants to be removed to meet requirements for radionuclide release. Removal of these contaminants has been a challenge since the 1950's, and several methods including cryogenic distillation, fluorocarbon absorption, wet scrubbing, and adsorption have been employed. Currently, adsorption on porous solid sorbents shows the most promising results. Until now, several sorbents such as silver impregnated mordenite, silver Engelhard titanosilicate 10, chalcogen based aerogels, and metal organic framework, MOFs have been investigated for this purpose. Despite these advances, development of economical and highly active sorbents for complete removal and immobilization of volatile radioactive gases remains a key challenge in realizing advanced fuel cycles. This work is focused on the multicomponent of {sup 85}Kr and {sup 129}I from a simulated off-gas with an Engelhard titanosilicate 10 (ETS-10) supported carbon nano-polyhedron sorbent. Adsorption studies were performed to determine iodine sorption capacity as a function of temperature and iodine inlet concentration. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of wind generation within adequacy calculations and capacity markets for different power systems

The integration of renewable energy sources, including wind power, in the adequacy assessment of electricity generation capacity becomes increasingly important as renewable energy generation increases in volume and replaces conventional power plants. The contribution of wind power to cover the electricity demand is less certain than conventional power sources; therefore, the capacity value of wind power is smaller than that of conventional plants. This article presents an overview of the adequacy challenge, how wind power is handled in the regulation of capacity adequacy, and how wind power is treated in a selection of jurisdictions. The jurisdictions included in the overview are Sweden, Great Britain, France, Ireland, United States (PJM and ERCOT), Finland, Portugal, Spain, Norway, Denmark, Belgium, Germany, Italy and the Netherlands.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Moisture on the Adsorption of Iodine and Krypton in Multicomponent Streams on the 10 WT% C/ETS-10 Sorbent

Over 13% of the world's energy demand is supplied by nuclear power plants in 31 countries. This demand is growing; by 2030 the IAEA predicts a 100% increase in the demand for nuclear energy. The increase in nuclear energy production imposes a growing strain on the uranium fuel supply. At current consumption rates the world's supply of uranium is projected to last ∼200 years. With the growing energy consumption, uranium supplies will dwindle even more quickly. However, ∼95% of uranium is left in used nuclear fuel (UNF) and may be utilized through reprocessing. A main concern with reprocessing is the release of off-gas. The major constituents of off-gas include {sup 85}Kr, {sup 129}I, {sup 14}C, {sup 3}H, and various Xe isotopes. {sup 85}Kr and {sup 129}I present the largest threat due to their harmful environmental effects and abundance. Several methods have been studied for the removal of these contaminants, including cryogenic distillation, fluorocarbon absorption, wet scrubbing, and adsorption have been employed. Adsorption on porous solid sorbents has the advantages of being simple, effective, and economic. Thus many studies have been performed investigating several sorbents such as silver impregnated mordenite, silver Engelhard titanosilicate 10, chalcogen-based aerogels, and metal organic frameworks. Despite these advances, many of these studies have been conducted under ideal conditions: cryogenic temperature, helium as a carrier gas, and single component adsorption. The need for investigating adsorption under conditions more representative of practical use is needed. Thus our work has been devoted to the study of adsorption of {sup 85}Kr and {sup 129}I from a simulated off-gas on an Engelhard titanosilicate 10 (ETS-10) supported carbon nanopolyhedron sorbent (C/ETS-10) in a multicomponent system at ambient temperatures. Previously we have reported sorption capacities of C/ETS-10 for single component krypton, and iodine. The effects multi-contaminant iodine and krypton and their respective inlet concentrations on the sorption capacity of 10 wt% C/ETS-10 have also been studied. Investigations into the effect of the presence of moisture in the multicomponent gas mixture on the sorption on 10 wt% C/ETS-10 are described in this paper.

36 MATERIALS SCIENCE↗