Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA DENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Standing hydromagnetic waves observed by ISEE 1 and 2 - Radial extent and harmonic

Direct measurements of the spatial extent of the resonant hydromagnetic waves associated with Pc 4 and 5 magnetic pulsations made by the closely spaced ISEE 1 and 2 satellites are presented together with ISEE 1 determinations of the harmonic of the resonant waves. The use of two satellites in similar orbits, which makes it possible to distinguish between spatial and temporal features, has shown the resonant region widths to extend over about 0.2 to 1.6 L shells for three events detected on the dayside between L = 4 and L = 7. The two events for which plasma density data was available occurred at plasma density gradients in the vicinity of the plasmapause. The standing wave harmonic was determined by the combination of two techniques: the comparison of the observed wave period with that predicted by standing wave theory, and the comparison of the phases of the observed wave electric and magnetic field. The two events analyzed are found to be second harmonic oscillations, suggesting internal generation in the magnetosphere by a bounce resonant mechanism.

Singer, H. J.↗

Two dimensional density and its fluctuation measurements by using phase imaging method in GAMMA 10

Two dimensional (2D) plasma image analysis is useful to study the improvement of plasma confinement in magnetically confined fusion plasmas. We have constructed a 2D interferometer system with phase imaging method for studying 2D plasma density distribution and its fluctuation measurement in the tandem mirror GAMMA 10. 2D profiles of electron density and its fluctuation have been successfully obtained by using this 2D phase imaging system. We show that 2D plasma density and fluctuation profiles clearly depends on the axial confining potential formation with application of plug electron cyclotron heating in GAMMA 10.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser red shifting based characterization of wakefield excitation in a laser-plasma accelerator

Optical spectra of a drive laser exiting a channel guided laser-plasma accelerator (LPA) are analyzed through experiments and simulations to infer the magnitude of the excited wakefields. The experiments are performed at sufficiently low intensity levels and plasma densities to avoid electron beam generation via self-trapping. Spectral redshifting of the laser light is studied as an indicator of the efficiency of laser energy transfer into the plasma through the generation of coherent plasma wakefields. Influences of input laser energy, plasma density, temporal and spatial laser profiles, and laser focal location in a plasma channel are analyzed. Energy transfer is found to be sensitive to details of laser pulse shape and focal location. The experimental conditions for these critical parameters are modeled and included in particle-in-cell simulations. Simulations reproduce the redshift of the laser within uncertainties of the experiments and produce an estimate of the wake amplitudes in the experiments as a function of amount of redshift. The results support the practical use of laser redshifting to quantify the longitudinally averaged accelerating field that a particle would experience in an LPA powered below the self-trapping limit.

43 PARTICLE ACCELERATORS↗

Laser-heated capillary discharge waveguides as tunable structures for laser-plasma acceleration

Laser-heated capillary discharge waveguides are novel, low plasma density guiding structures able to guide intense laser pulses over many diffraction lengths and have recently enabled the acceleration of electrons to 7.8 GeV by using a laser-plasma accelerator (LPA). These devices represent an improvement over conventional capillary discharge waveguides, as the channel matched spot size and plasma density can be tuned independently of the capillary radius. This has allowed the guiding of petawatt-scale pulses focused to small spot sizes within large diameter capillaries, preventing laser damage of the capillary structure. High performance channel-guided LPAs require control of matched spot size and density, which experiments and simulations reported here show can be tuned over a wide range via initial discharge and laser parameters. In this paper, measurements of the matched spot size and plasma density in laser-heated capillary discharges are presented, which are found to be in excellent agreement with simulations performed using the MHD code MARPLE. Strategies for optimizing accelerator performance are identified based on these results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluid simulation of the bias effect in inductive/capacitive discharges

Computer simulations are performed for an argon inductively coupled plasma (ICP) with a capacitive radio-frequency bias power, to investigate the bias effect on the discharge mode transition and on the plasma characteristics at various ICP currents, bias voltages, and bias frequencies. When the bias frequency is fixed at 13.56 MHz and the ICP current is low, e.g., 6 A, the spatiotemporal averaged plasma density increases monotonically with bias voltage, and the bias effect is already prominent at a bias voltage of 90 V. The maximum of the ionization rate moves toward the bottom electrode, which indicates clearly the discharge mode transition in inductive/capacitive discharges. At higher ICP currents, i.e., 11 and 13 A, the plasma density decreases first and then increases with bias voltage, due to the competing mechanisms between the ion acceleration power dissipation and the capacitive power deposition. At 11 A, the bias effect is still important, but it is noticeable only at higher bias voltages. At 13 A, the ionization rate is characterized by a maximum at the reactor center near the dielectric window at all selected bias voltages, which indicates that the ICP power, instead of the bias power, plays a dominant role under this condition, and no mode transition is observed. Indeed, the ratio of the bias power to the total power is lower than 0.4 over a wide range of bias voltages, i.e., 0–300 V. Besides the effect of ICP current, also the effect of various bias frequencies is investigated. It is found that the modulation of the bias power to the spatiotemporal distributions of the ionization rate at 2 MHz is strikingly different from the behavior observed at higher bias frequencies. Furthermore, the minimum of the plasma density appears at different bias voltages, i.e., 120 V at 2 MHz and 90 V at 27.12 MHz.

42 ENGINEERING↗

Scattering of electromagnetic waves by vortex density structures associated with interchange instability: Analytical and large scale plasma simulation results

The presence of plasma turbulence can strongly influence propagation properties of electromagnetic signals used for surveillance and communication. In particular, we are interested in the generation of low frequency plasma density irregularities in the form of coherent vortex structures. Interchange or flute type density irregularities in magnetized plasma are associated with Rayleigh-Taylor type instability. These types of density irregularities play an important role in refraction and scattering of high frequency electromagnetic signals propagating in the earth ionosphere, in high energy density physics, and in many other applications. We will discuss scattering of high frequency electromagnetic waves on low frequency density irregularities due to the presence of vortex density structures associated with interchange instability. We will also present particle-in-cell simulation results of electromagnetic scattering on vortex type density structures using the large scale plasma code LSP and compare them with analytical results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The radio-frequency fluctuation effect on the floating harmonic method

The radio-frequency (RF) plasma diagnostics with an electrical probe facing a challenge, because the RF fluctuation oscillates the plasma potential and distorts the current-voltage (I-V) curve. As Langmuir probe is widely used in plasma diagnostics, many researchers have been studying the effect of RF fluctuation on probe and compensation methods. On the other hand, there have not been enough studies on the fluctuation effect on the floating harmonic method. Therefore, we investigated the impact of RF fluctuation on the floating harmonic method theoretically and experimentally. When the electrons are in ideal Maxwellian distribution, the floating potential is negatively shifted by the RF fluctuation, but the fluctuation does not distort I-V curve around the floating potential. However, in practical plasmas, the I-V curve and their harmonic components are distorted. This RF fluctuation effect becomes more significant in a low density plasma with a high impedance sheath. The second harmonic current decreases with the RF fluctuation while the first harmonic current is merely affected. Therefore, the electron temperatures measured with the floating harmonic method under low density plasma with uncompensated probe are overestimated than the results obtained with the compensated probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tomographic inversion techniques incorporating physical constraints for line integrated spectroscopy in stellarators and tokamaks

Accurate tomographic inversion is important for diagnostic systems on stellarators and tokamaks which rely on measurements of line integrated emission spectra. A tomographic inversion technique based on spline optimization with enforcement of constraints is described that can produce unique and physically relevant inversions even in situations with noisy or incomplete input data. This inversion technique is routinely used in the analysis of data from the x-ray imaging crystal spectrometer (XICS) installed at the Large Helical Device. The XICS diagnostic records a 1D image of line integrated emission spectra from impurities in the plasma. Through the use of Doppler spectroscopy and tomographic inversion, XICS can provide profile measurements of the local emissivity, temperature, and plasma flow. Tomographic inversion requires the assumption that these measured quantities are flux surface functions, and that a known plasma equilibrium reconstruction is available. In the case of low signal levels or partial spatial coverage of the plasma cross-section, standard inversion techniques utilizing matrix inversion and linear-regularization often cannot produce unique and physically relevant solutions. The addition of physical constraints, such as parameter ranges, derivative directions, and boundary conditions, allow for unique solutions to be reliably found. The constrained inversion technique described here utilizes a modified Levenberg-Marquardt optimization scheme, which introduces a condition avoidance mechanism by selective reduction of search directions. The constrained inversion technique also allows for the addition of more complicated parameter dependencies, for example, geometrical dependence of the emissivity due to asymmetries in the plasma density arising from fast rotation. The accuracy of this constrained inversion technique is discussed, with an emphasis on its applicability to systems with limited plasma coverage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic measurements of the parameters of the helium plasma jets generated in the plasma focus discharge at the PF-3 facility

The spectroscopic technique used to measure the parameters of the plasma jets generated in the plasma focus discharge and those of the plasma of the immobile gas through which these jets propagate is described. The time evolution of the intensities and shapes of spectral lines in experiments carried out with helium at the PF-3 facility was studied by means of electron-optical streak cameras. The plasma electron temperature, T ≈ 4–5 eV, was determined from the intensity ratio of two spectral lines, one of which (λ{sub 1} = 5876 Å) belongs to neutral helium, while the other (λ{sub 2} = 4686 Å), to hydrogen-like helium ions. The plasma density at different time instants was determined from the Stark broadening of these lines in the electric fields of different nature. The plasma density is found to vary from 4 × 10{sup 14} to 2 × 10{sup 17} cm{sup −3}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High intensity electron cyclotron resonance proton source for low energy high intensity proton accelerator

Electron cyclotron resonance (ECR) proton source at 50 keV, 50 mA has been designed, developed, and commissioned for the low energy high intensity proton accelerator (LEHIPA). Plasma characterization of this source has been performed. ECR plasma was generated with 400-1100 W of microwave power at 2.45 GHz, with hydrogen as working gas. Microwave was fed in the plasma chamber through quartz window. Plasma density and temperature was studied under various operating conditions, such as microwave power and gas pressure. Langmuir probe was used for plasma characterization using current voltage variation. The typical hydrogen plasma density and electron temperature measured were 7x10{sup 11} cm{sup -3} and 6 eV, respectively. The total ion beam current of 42 mA was extracted, with three-electrode extraction geometry, at 40 keV of beam energy. The extracted ion current was studied as a function of microwave power and gas pressure. Depending on source pressure and discharge power, more than 30% total gas efficiency was achieved. The optimization of the source is under progress to meet the requirement of long time operation. The source will be used as an injector for continuous wave radio frequency quadrupole, a part of 20 MeV LEHIPA. The required rms normalized emittance of this source is less than 0.2 {pi} mm mrad. The simulated value of normalized emittance is well within this limit and will be measured shortly. This paper presents the study of plasma parameters, first beam results, and the status of ECR proton source.

43 PARTICLE ACCELERATORS↗

Polarimetry diagnostic on OMEGA EP using a 10-ps, 263-nm probe beam

A polarimetry diagnostic was built and characterized for magnetic-field measurements in laser-plasma experiments on the OMEGA EP laser. This diagnostic was built into the existing 4ω (263-nm) probe system that employs a 10-ps laser pulse collected with an f/4 imaging system. The diagnostic measures the rotation of the probe beam's polarization. The polarimeter uses a Wollaston prism to split the probe beam into orthogonal polarization components. Spatially localized intensity variations between images indicate polarization rotation. Magnetic fields can be calculated by combining the polarimetry data with the measured plasma density profile obtained from angular filter refractometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam-driven acceleration in ultra-dense plasma media

Accelerating parameters of beam-driven wakefield acceleration in an extremely dense plasma column has been analyzed with the dynamic framed particle-in-cell plasma simulator, and compared with analytic calculations. In the model, a witness beam undergoes a TeV/m scale alternating potential gradient excited by a micro-bunched drive beam in a 10{sup 25 }m{sup −3} and 1.6 × 10{sup 28 }m{sup −3} plasma column. The acceleration gradient, energy gain, and transformer ratio have been extensively studied in quasi-linear, linear-, and blowout-regimes. The simulation analysis indicated that in the beam-driven acceleration system a hollow plasma channel offers ∼20% higher acceleration gradient by enlarging the channel radius (r) from 0.2 λ{sub p} to 0.6 λ{sub p} in a blowout regime. This paper suggests a feasibility of TeV/m scale acceleration with a hollow crystalline structure (e.g., nanotubes) of high electron plasma density.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scattering of electromagnetic waves from a magnetized plasma column at oblique incidence

Scattering of electromagnetic waves from a magnetized plasma column is investigated using Maxwell's equations and applying boundary conditions. Backscattering cross section is evaluated by analytic solution of electric fields inside and outside of plasma column. Plots of backscattering cross section versus frequency, for the range up to J band, reveal two main peaks and two sidebands. Effects of plasma density and radius, as main parameters determining the characteristics of plasma column, on backscattering are discussed. Furthermore, the effect of electromagnetic wave incidence angle on backscattering of plasma column is included in the analysis. The influence of wave incidence angle and frequency, as well as, plasma density and radius on scattering pattern, which is an indicator of the distribution of scattered power in different azimuthal angles, is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Initial Results from the Vector Electric Field Investigation on the C/NOFS Satellite

Initial results are presented from the Vector Electric Field Investigation (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. The VEFI instrument includes a vector DC electric field detector, a fixed-bias Langmuir probe operating in the ion saturation regime, a flux gate magnetometer, an optical lightning detector, and associated electronics including a burst memory. The DC electric field detector has revealed zonal and meridional electric fields that undergo a diurnal variation, typically displaying eastward and outward-directed fields during the day and westward and downward-directed fields at night. In general, the measured DC electric field amplitudes are in the 0.5-2 mV/m range, corresponding to I3 x B drifts of the order of 30-150 m/s. What is surprising is the high degree of large-scale (10's to 100's of km) structure in the DC electric field, particularly at night, regardless of whether well-defined spread-F plasma density depletions are present. The spread-F density depletions and corresponding electric fields that have been detected thus far have displayed a preponderance to appear between midnight and dawn. Associated with the narrow plasma depletions that are detected are broad spectra of electric field and plasma density irregularities for which a full vector set of measurements is available for detailed study. On some occasions, localized regions of low frequency (< 8 Hz) magnetic field broadband irregularities have been detected, suggestive of filamentary currents, although there is no one-to-one correspondence of these waves with the observed plasma density depletions, at least within the data examined thus far. Finally, the data set includes a wide range of ELF/VLF/HF waves corresponding to a variety of plasma waves, in particular banded ELF hiss, whistlers, and lower hybrid wave turbulence triggered by lightning-induced sferics. The VEFI data set represents a treasure trove of measurements that are germane to numerous fundamental aspects of the electrodynamics and irregularities inherent to the Earth's low latitude ionosphere.

Pfaff, R.↗

Ion focusing in enhanced glow discharge plasma immersion ion implantation of hydrogen and nitrogen into silicon

Ion focusing in enhanced glow discharge plasma immersion ion implantation (EGD-PIII) of hydrogen into silicon affects the lateral ion fluence uniformity. The phenomenon and its effects are investigated experimentally and theoretically under different conditions and compared to those in nitrogen EGD-PIII. Consistent results are obtained from experiments and numerical simulation disclosing that the lower the plasma density, the more severe is the ion focusing effect. The influence of the negative high voltage on the ion focusing effect is small compared to that of the plasma density.

36 MATERIALS SCIENCE↗

Double layer in a cylindrical hollow-cathode discharge

A dc cylindrical coaxial glow discharge with an inner grid anode has been studied. The region between the two electrodes is seen dark, while a brightly glowing region forms inside the grid anode up to the center. The current-voltage characteristic of a dc cylindrical glow discharge in nitrogen is similar to that of a normal glow discharge, while the normal glow discharge voltage decreases with increasing pressure. The minimum plasma potentials are observed in the hollow cathode region due to the accumulation of electrons at the back of the grid anode. At the center, some of the passed electrons are converged, so their potential is decreased. These electrons have a sufficient time to be redistributed to form one group with a Maxwellian electron energy distribution function. The electron temperature measured by electric probes varies from 1.6 to 3.6 eV, while the plasma density varies from 3.9 x 10{sup 16} to 7 x 10{sup 13} m{sup -3}, depending on the discharge current and probe position. The plasma density increases as the electrons move radially from the grid toward the central region, while their temperature decreases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Fiber Interferometer for the Magnetized Shock Experiment

The Magnetized Shock Experiment (MSX) at Los Alamos National Laboratory requires remote diagnostics of plasma density. Laser interferometry can be used to determine the line-integrated density of the plasma. A multi-chord heterodyne fiber optic Mach-Zehnder interferometer is being assembled and integrated into the experiment. The advantage of the fiber coupling is that many different view chords can be easily obtained by simply moving transmit and receive fiber couplers. Several such fiber sets will be implemented to provide a time history of line-averaged density for several chords at once. The multiple chord data can then be Abel inverted to provide radially resolved spatial profiles of density. We describe the design and execution of this multiple fiber interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental characterization of discharge plasma dynamics in a square capillary for prospective applications in laser wakefield acceleration

Research on plasma generated by electrical discharge in gas-filled capillaries plays an important role in advancing laser wakefield accelerators. We present a comprehensive study of the temporal and spatial distribution of plasma density within a short, 1 cm long, square-shaped capillary filled with hydrogen gas. Two transverse capillary sizes, 500 μm and 300 μm, were investigated achieving peak plasma densities of 0.9 × 10 18 cm −3 and 2.5 × 10 18 cm −3 , respectively, at the capillary center. In addition, we explore how these distributions depend on discharge parameters, specifically discharge current and gas flow through the capillary. Plasma density was determined by analyzing the Stark broadening of the hydrogen Balmer-alpha line. The results obtained were compared with the theoretical models and simulations. The comparison between the model predictions and the experimental data at the transient ionization stage of the discharge reveals a discrepancy of a factor of ∼1.3–2.1, depending on the capillary size, which is thoroughly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗