Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Evaluating Resilience of Water Distribution Networks to Operational Failures from Cyber-Physical Attacks

Water cyber-physical systems (CPSs) have gained increasing interest to improve operational efficiency and reliability. However, due to growing exposure to cyber-physical attacks, cybersecurity and resilience against the attacks have become significant concerns. There have been efforts to improve cybersecurity in water CPSs, yet few attempts to investigate resilience against cyber-physical attacks. This study contributes to characterizing resilience of a water CPS and investigating potential resilience strategies. An advanced resilience measure integrating withstanding, absorptive, adaptive, and restorative capability of a system is proposed and applied to the C-town water distribution network (WDN) for 15 failure set scenarios with a pressure-driven hydraulic simulation. The results provide identification of failure sets and unfavorable operational conditions that make the system more vulnerable to the cyber-physical attacks and in turn produce low resilience and capabilities. It is also found that, after recovery of a disrupted component, adjustment of overall operational interactions across system components is needed for complete restoration of disrupted functionality. The findings provide insights on infrastructure investment with resilience strategies in cyber and physical water system domains.

Shin, Sangmin↗

PhysBERT: A text embedding model for physics scientific literature

The specialized language and complex concepts in physics pose significant challenges for information extraction through Natural Language Processing (NLP). Central to effective NLP applications is the text embedding model, which converts text into dense vector representations for efficient information retrieval and semantic analysis. In this work, we introduce PhysBERT, the first physics-specific text embedding model. Pre-trained on a curated corpus of 1.2 × 106 arXiv physics papers and fine-tuned with supervised data, PhysBERT outperforms leading general-purpose models on physics-specific tasks, including the effectiveness in fine-tuning for specific physics subdomains.

Hellert, Thorsten (ORCID:0000000227970926)↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New physics search at the CEPC: a general perspective

A next generation, high-intensity electron-positron collider “Higgs factory”, such as the Circular Electron-Positron Collider (CEPC), is among the highest priority for the global high energy collider physics community. The CEPC can provide unprecedented opportunities for making fundamental discoveries and providing decisive insights in the quest for a “New Standard Model (SM)” of nature’s fundamental interactions. The CEPC could: 1) Identify the origin of matter, especially the mechanism related to the first-order phase transition in the early Universe, which could produce a detectable gravitational wave signal. 2) Discover dark matter, particularly dark matter particles with a mass between one tenth and 100 times the proton mass. 3) Observe an array of new physics smoking guns, with sensitivities orders of magnitude better than those of existing facilities. The SM of Particle Physics is a triumph of the past half a century, as it predicts and interprets almost all the phenomena observed in experiments from the highest energies with colliders to low energy “tabletop” studies. On the other hand, deep mysteries exist concerning the most fundamental interactions of matter and the space-time fabric of the Universe, including the nature of dark matter, the origin of “visible” matter, the vast hierarchy of elementary particle masses, the quantum nature of gravity, and the mechanism of inflation. These mysteries challenge us to look for “new physics” beyond the SM and General Relativity. Indeed, physicists believe that the SM is simply a low-energy effective theory that reflects aspects of the more profound theory that answers the aforementioned mysteries. Uncovering this “New SM”, the profound theory who supports the SM is the primary mission for particle physics in the post-Higgs boson era.

Ai 艾, Xiaocong 小聪 [Zhengzhou University (China); e↗

Explainable physics-based constraints on reinforcement learning for accelerator optimization

We present a reinforcement learning (RL) framework for optimizing particle accelerator experiments that builds explainable physics-based constraints on agent behavior. The goal is to increase transparency and trust by letting users verify that the agent’s decision-making process incorporates suitable physics. Our algorithm uses a learnable surrogate function for physical observables, such as energy, and uses them to fine-tune how actions are chosen. This surrogate can be represented by a neural network or by an interpretable sparse dictionary model. We test our algorithm on a range of particle accelerator optimization environments designed to emulate the Continuous Electron Beam Accelerator Facility at Jefferson Lab. By examining the mathematical form of the learned constraint function, we are able to confirm the agent has learned to use the established physics of each environment. In addition, we find that the introduction of a physics-based surrogate enables our RL algorithms to reliably converge for difficult high-dimensional accelerator optimization environments.

explainability↗

Modelling baryonic physics in future weak lensing surveys

Modifications of the matter power spectrum due to baryonic physics are one of the major theoretical uncertainties in cosmological weak lensing measurements. Developing robust mitigation schemes for this source of systematic uncertainty increases the robustness of cosmological constraints, and may increase their precision if they enable the use of information from smaller scales. Here we explore the performance of two mitigation schemes for baryonic effects in weak lensing cosmic shear: the principal component analysis (PCA) method and the halo-model approach in hmcode. We construct mock tomographic shear power spectra from four hydrodynamical simulations, and run simulated likelihood analyses with cosmolike assuming LSST-like survey statistics. With an angular scale cut of ℓmax < 2000, both methods successfully remove the biases in cosmological parameters due to the various baryonic physics scenarios, with the PCA method causing less degradation in the parameter constraints than hmcode. For a more aggressive ℓmax = 5000, the PCA method performs well for all but one baryonic physics scenario, requiring additional training simulations to account for the extreme baryonic physics scenario of Illustris; hmcode exhibits tensions in the 2D posterior distributions of cosmological parameters due to lack of freedom in describing the power spectrum for $k \gt 10\ h^{-1}\, \mathrm{Mpc}$. We investigate variants of the PCA method and improve the bias mitigation through PCA by accounting for the noise properties in the data via Cholesky decomposition of the covariance matrix. Our improved PCA method allows us to retain more statistical constraining power while effectively mitigating baryonic uncertainties even for a broad range of baryonic physics scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Learning from metastable symmetric-tilt grain boundaries using physics-based descriptors

Grain boundaries (GBs) govern critical properties of polycrystalline materials. Although significant advancements have been made in characterizing minimum energy and ordered GBs, real GBs are seldom found in such well-defined states. This diversity of atomic arrangements in metastable states makes it challenging to establish structure-property relationships with physical insights. Here, to address this challenge, we use data-driven methods to explore these relationships and examine the underlying physics. In this study, we utilize a large atomistic database (~5000) of minimum energy and metastable states of symmetric-tilt copper GBs, combined with physically motivated local atomic environment (LAE) descriptors [strain functional descriptors (SFDs)], to predict GB properties and gain physical insights. Our regression models exhibit robust predictive capabilities using only 19 descriptors, generalizing to atomic environments in nanocrystals. A significant highlight of our work is the integration of an unsupervised method with SFDs to elucidate LAEs at GBs and their role in determining properties. The model, trained on these minimum energy and metastable GBs using SFDs, predicts the properties of unseen nanocrystals with good accuracy. Our research underscores the role of a physics-based representation of LAEs and the efficacy of data-driven methods in establishing GB structure-property relationships.

36 MATERIALS SCIENCE↗

Real-Time Cyber-Physical False Data Attack Detection in Smart Grids Using Neural Networks

Attacks on cyber-physical systems have recently increased in frequency, impact, and publicity. In this paper, a cyber-physical false data attack detection mechanism is proposed to protect the operation of power transmission and distribution systems by automatically inferring underlying physical relationships using cross-sensor analytics in order to detect sensor failures, replay attacks, and other data integrity issues in real-time. We investigate a neural network based mechanism acting on voltage and current readings resulting from a wide variety of load conditions on the IEEE 30-bus power system standard and compare its performance with a support vector machine based mechanism. Experiments showed that 99% detection accuracy of replay attacks was achieved using the proposed neural network mechanism. More importantly, we showed that the best approach was to not create physics-based features using what we knew about the system, but rather to use a neural network to automatically learn the laws, and then use the outputs of that to build a classifier to identify whether and where data spoofing occurs. Thus, it is preferable to infer and exploit the physics using a single machine learning solution

Ferragut, Erik M.↗

Electromagnetic design, engineering development and magnetic qualification of a horizontal layered scaled magnet for physics experiments

Neutrino detectors around the world have shown evidence that these weakly interacting, little-understood particles are not really mass less, as was thought so far. Not only do they have non-zero masses, different species (or flavors) of neutrinos seem to mix and oscillate into one another as they traverse through the cosmos. If this is true, this is not only one of the first pieces of evidence for physics beyond the so-called Standard Model of Particle Physics, but would also have great impact on diverse fields such as nuclear and particle physics, astrophysics and cosmology. It is thus imperative to study the details of the interactions of these particles. These will be detected by means of an iron calorimeter (ICAL), comprising detectors sandwiched in alternate layers of soft magnetic iron. The iron core is magnetized to allow bending of the charged particles. The direction and the energy of the original incoming neutrino, that caused the interaction, can then be accurately determined. Racetrack coils through slots cut in the iron core create a uniform magnetic field in the iron core. A highly uniform magnetic field in the soft iron core is required to accurately determine the mass and energy of incident particle. The charged particles bend in this magnetic field; oppositely charged particles bending in opposite directions. The charge, energy and momentum of the emitted particle is thus determined. An electromagnet was designed as a laboratory facility for conducting experimental studies in particle physics. This paper discusses the electromagnetic design, development, fabrication, magnetic qualification and magnetic measurement issues of an electromagnet developed for physics studies. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting Sensors and Inferring their Relations at Level-0 in Industrial Cyber-Physical Systems

While there exist tools and techniques to discover, identify, map, and analyze cyber physical components at higher levels of the cyber space, there is a lack of capabilities to reach down to the sensors at the bottom-most levels, such as levels 0 and 1 of the Purdue Enterprise Reference Model for cyber-physical systems (CPS). Conventional information technology (IT)-based tools reach as far as the network-side of programmable logic controllers, but are inadequate to access and analyze the physical side of the CPS infrastructure that directly interfaces with the actual physical processes and systems. In this paper, we present our research and development efforts aimed at addressing this gap, by building a system called Deep-cyberia (Deep Cyber-Physical System Interrogation and Analysis) that incorporates algorithms and interfaces aimed at uncovering sensors and computing estimates of correlations among them.

Perumalla, Kalyan↗

A Computational Framework for Control Co-Design of Resilient Cyber–Physical Systems With Applications to Microgrids

Critical infrastructure networks, such as power and transportation networks, can be modelled as cyber-physical systems. As the complexity of such systems grow, there is need for developing metrics and design tools that will co-optimize the physical components of the system and the control policies to guarantee resilience against cyber and natural threats. To that end, we develop a simulation-based control co-design computational framework that will concurrently determine the system and control parameters of a cyber-physical system to meet pre-specified resilience, operational and economic objectives. Here, the capabilities of the developed co-design engine is demonstrated by designing the physical components and control parameters of a microgrid system that will meet its resiliency objectives when subjected to various cyber and physical threats.

97 MATHEMATICS AND COMPUTING↗

Select Advances in Computational Accelerator Physics

Computational accelerator physics has changed and broadened over the last decade or so. Part of the change is due to the advent of multiple ways of parallel computing. Another part comes from algorithmic developments. The multiple ways of parallel computing include distributed memory parallelism and on-chip parallelism, with the latter coming from architectures (CPU and GPU) having multiple processing elements (cores or streaming multiprocessors) and wide vector (SIMD) instruction units. The basics of these new architectures and their application to computational accelerator physics are briefly reviewed. Algorithmic advances in the select areas of spin tracking, cavity calculations, plasma acceleration, and electron cooling are also reviewed. In some cases the algorithms provide increased fidelity improving the overall accuracy, while in other cases, such as controlled dispersion, the algorithms provide increased fidelity by better modeling the essential physical interaction. Finally, the use of computational frameworks, which provide the basic computational infrastructure, while allowing the capability developer to concentrate on the math and physics, is reviewed in the context of the Vorpal application, which has found use across accelerator physics and many other fields.

Engineering↗

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

SU-E-T-562: Scanned Percent Depth Dose Curve Discrepancy for Photon Beams with Physical Wedge in Place (Varian IX) Using Different Sensitive Volume Ion Chambers

Purpose: To investigate and report the discrepancy of scanned percent depth dose (PDD) for photon beams with physical wedge in place when using ion chambers with different sensitive volumes. Methods/Materials: PDD curves of open fields and physical wedged fields (15, 30, 45, and 60 degree wedge) were scanned for photon beams (6MV and 10MV, Varian iX) with field size of 5x5 and 10x10 cm using three common scanning chambers with different sensitive volumes - PTW30013 (0.6cm3), PTW23323 (0.1cm3) and Exradin A16 (0.007cm3). The scanning system software used was OmniPro version 6.2, and the scanning water tank was the Scanditronix Wellhoffer RFA 300.The PDD curves from the three chambers were compared. Results: Scanned PDD curves of the same energy beams for open fields were almost identical between three chambers, but the wedged fields showed non-trivial differences. The largest differences were observed between chamber PTW30013 and Exradin A16. The differences increased as physical wedge angle increased. The differences also increased with depth, and were more pronounced for 6MV beam. Similar patterns were shown for both 5x5 and 10x10 cm field sizes. For open fields, all PDD values agreed with each other within 1% at 10cm depth and within 1.62% at 20 cm depth. For wedged fields, the difference of PDD values between PTW30013 and A16 reached 4.09% at 10cm depth, and 5.97% at 20 cm depth for 6MV with 60 degree physical wedge. Conclusion: We observed a significant difference in scanned PDD curves of photon beams with physical wedge in place obtained when using different sensitive volume ion chambers. The PDD curves scanned with the smallest sensitive volume ion chamber showed significant difference from larger chamber results, beyond 10cm depth. We believe this to be caused by varying response to beam hardening by the wedges.

07 ISOTOPE AND RADIATION SOURCES↗

MO-E-18C-04: Advanced Computer Simulation and Visualization Tools for Enhanced Understanding of Core Medical Physics Concepts

Purpose: Most medical physics programs emphasize proficiency in routine clinical calculations and QA. The formulaic aspect of these calculations and prescriptive nature of measurement protocols obviate the need to frequently apply basic physical principles, which, therefore, gradually decay away from memory. E.g. few students appreciate the role of electron transport in photon dose, making it difficult to understand key concepts such as dose buildup, electronic disequilibrium effects and Bragg-Gray theory. These conceptual deficiencies manifest when the physicist encounters a new system, requiring knowledge beyond routine activities. Methods: Two interactive computer simulation tools are developed to facilitate deeper learning of physical principles. One is a Monte Carlo code written with a strong educational aspect. The code can “label” regions and interactions to highlight specific aspects of the physics, e.g., certain regions can be designated as “starters” or “crossers,” and any interaction type can be turned on and off. Full 3D tracks with specific portions highlighted further enhance the visualization of radiation transport problems. The second code calculates and displays trajectories of a collection electrons under arbitrary space/time dependent Lorentz force using relativistic kinematics. Results: Using the Monte Carlo code, the student can interactively study photon and electron transport through visualization of dose components, particle tracks, and interaction types. The code can, for instance, be used to study kerma-dose relationship, explore electronic disequilibrium near interfaces, or visualize kernels by using interaction forcing. The electromagnetic simulator enables the student to explore accelerating mechanisms and particle optics in devices such as cyclotrons and linacs. Conclusion: The proposed tools are designed to enhance understanding of abstract concepts by highlighting various aspects of the physics. The simulations serve as virtual experiments that give deeper and long lasting understanding of core principles. The student can then make sound judgements in novel situations encountered beyond routine clinical activities.

60 APPLIED LIFE SCIENCES↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

WE-E-12A-01: Medical Physics 1.0 to 2.0: MRI, Displays, Informatics

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidence-based medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. MRI 2.0: This presentation will look into the future of clinical MR imaging and what the clinical medical physicist will need to be doing as the technology of MR imaging evolves. Many of the measurement techniques used today will need to be expanded to address the advent of higher field imaging systems and dedicated imagers for specialty applications. Included will be the need to address quality assurance and testing metrics for multi-channel MR imagers and hybrid devices such as MR/PET systems. New pulse sequences and acquisition methods, increasing use of MR spectroscopy, and real-time guidance procedures will place the burden on the medical physicist to define and use new tools to properly evaluate these systems, but the clinical applications must be understood so that these tools are use correctly. Finally, new rules, clinical requirements, and regulations will mean that the medical physicist must actively work to keep her/his sites compliant and must work closely with physicians to ensure best performance of these systems. Informatics Display 1.0 to 2.0: Medical displays are an integral part of medical imaging operation. The DICOM and AAPM (TG18) efforts have led to clear definitions of performance requirements of monochrome medical displays that can be followed by medical physicists to ensure proper performance. However, effective implementation of that oversight has been challenging due to the number and extend of medical displays in use at a facility. The advent of color display and mobile displays has added additional challenges to the task of the medical physicist. This informatics display lecture first addresses the current display guidelines (the 1.0 paradigm) and further outlines the initiatives and prospects for color and mobile displays (the 2.0 paradigm). Informatics Management 1.0 to 2.0: Imaging informatics is part of every radiology practice today. Imaging informatics covers everything from the ordering of a study, through the data acquisition and processing, display and archiving, reporting of findings and the billing for the services performed. The standardization of the processes used to manage the information and methodologies to integrate these standards is being developed and advanced continuously. These developments are done in an open forum and imaging organizations and professionals all have a part in the process. In the Informatics Management presentation, the flow of information and the integration of the standards used in the processes will be reviewed. The role of radiologists and physicists in the process will be discussed. Current methods (the 1.0 paradigm) and evolving methods (the 2.0 paradigm) for validation of informatics systems function will also be discussed. Learning Objectives: Identify requirements for improving quality assurance and compliance tools for advanced and hybrid MRI systems. Identify the need for new quality assurance metrics and testing procedures for advanced systems. Identify new hardware systems and new procedures needed to evaluate MRI systems. Understand the components of current medical physics expectation for medical displays. Understand the role and prospect fo medical physics for color and mobile display devices. Understand different areas of imaging informatics and the methodology for developing informatics standards. Understand the current status of informatics standards and the role of physicists and radiologists in the process, and the current technology for validating the function of these systems.

07 ISOTOPE AND RADIATION SOURCES↗

TU-A-210-01: HIFU Physics and Delivery

High-intensity focused ultrasound (HIFU) has developed rapidly in recent years and is used frequently for clinical treatments in Asia and Europe with increasing clinical use and clinical trial activity in the US, making it an important medical technology with which the medical physics community must become familiar. Akin to medical devices that deliver treatments using ionizing radiation, HIFU relies on emitter geometry to non-invasively form a tight focus that can be used to affect diseased tissue while leaving healthy tissue intact. HIFU is unique in that it does not involve the use of ionizing radiation, it causes thermal necrosis in 100% of the treated tissue volume, and it has an immediate treatment effect. However, because it is an application of ultrasound energy, HIFU interacts strongly with tissue interfaces, which makes treatment planning challenging. In order to appreciate the advantages and disadvantages of HIFU as a thermal therapy, it is important to understand the underlying physics of ultrasound tissue interactions. The first lecture in the session will provide an overview of the physics of ultrasound wave propagation; the mechanism for the accumulation of heat in soft-tissue; image-guidance modalities including temperature monitoring; current clinical applications and commercial devices; active clinical trials; alternate mechanisms of action (future of FUS). The second part of the session will compare HIFU to existing ionization radiation techniques. The difficulties in defining a clear concept of absorbed dose for HIFU will be discussed. Some of the technical challenges that HIFU faces will be described, with an emphasis on how the experience of radiation oncology physicists could benefit the field. Learning Objectives: Describe the basic physics and biology of HIFU, including treatment delivery and image guidance techniques. Summarize existing and emerging clinical applications and manufacturers for HIFU. Understand that thermal ablation with HIFU is likely the first of several applications of the technology Learn about some similarities and differences between HIFU and ionizing radiation in terms of physics and biological effects. Learn about some of the technical challenges HIFU faces that might benefit from the experience of radiation oncology physicists including treatment planning improvements, quality assurance procedures, and treatment risk analysis. David Schlesinger receives research support from Elekta Instruments, AB. Matt Eames is an employee of the Focused Ultrasound Foundation which supports research and clinical trials. Dr. Eames conducts research which is supported by the Focused Ultrasound Foundation.

60 APPLIED LIFE SCIENCES↗