Ultrafast Laser-Excited Optical Emission of Xe under Loose-Focusing Conditions

The optical filament-based radioxenon sensing can potentially overcome the constraints of conventional detection techniques that are relevant for nuclear security applications. This study investigates the spectral signatures of pure xenon (Xe) when excited by ultrafast laser filaments at near-atmosphericpressure and in short and loose-focusing conditions. The two focusing conditions lead to laser intensity differences of several orders of magnitude and different plasma transient behavior. The gaseous sample was excited at atmospheric pressure using ∼7 mJ pulses with a 35 fs pulse duration at 800 nm wavelength. The optical signatures were studied by time-resolved spectrometry and imaging in orthogonal light collection configurations in the ∼400 nm (VIS) and ∼800 nm (NIR) spectral regions. The most prominent spectral lines of atomic Xe are observable in both focusing conditions. An on-axis light collection from an atmospheric air–Xe plasma mixture demonstrates the potential of femtosecond filamentation for the remote sensing of noble gases.

47 OTHER INSTRUMENTATION↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas

Bolometers measure the plasma radiation and provide essential diagnostic information both for safe, sustainable operation of magnetic-confinement fusion (MCF) devices and for study of the relevant physics. The fusion community has been replying on resistive bolometers for plasma radiation measurement. However, their performance is greatly compromised by the strong electromagnetic interference present in MCF devices. Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. In this project, we study the performance of the fiber-optic bolometer in a simulated MCF environment and improved the sensitivity through a novel sensor design. Part of the work reported here was performed between 09/01-12/31/2017 when the PI was with University of Nebraska-Lincoln under the same project but with a different award number (DE-SC0018273).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revisiting the Detection of Optical Lightning Superbolts

This study uses Fast On-Orbit Detection of Transient Events (FORTE) satellite observations to identify superbolt-class optical lightning events and evaluate their origins. Superbolts have been defined by Turman as lightning pulses whose peak optical power exceeds 1011 W. However, it has been unclear whether superbolts resulted from particular types of high-energy lightning process or whether they were the result of measurement bias. In the latter case, any decently bright lightning process could be recorded as a superbolt if the sensor had a particularly clear sight line to the hot channel without thick clouds diluting the optical signals. Here, our 12-year analysis of FORTE superbolt detections indicates that the lower optical superbolt energy range (~100 GW) is dominated by normal lightning, but brighter cases are predominantly strong +CG strokes that originate from specific types of storms. Oceanic storm systems, particularly during the winter, and especially those located around Japan are shown to produce these intense superbolts. We suggest that some optical superbolts result from favorable viewing conditions and would not be identified as such by another instrument located elsewhere and that others are associated with a unique set of physics that may merit the “superbolt” distinction.

54 ENVIRONMENTAL SCIENCES↗

Non-linear enhancement of ultrafast X-ray diffraction through transient resonances

Diffraction-before-destruction imaging with ultrashort X-ray pulses can visualize non-equilibrium processes, such as chemical reactions, with sub-femtosecond precision in the native environment. Here, a nanospecimen diffracts a single X-ray flash before it disintegrates. The sample structure can be reconstructed from the coherent diffraction image (CDI). State-of-the-art X-ray snapshots lack high spatial resolution because of weak diffraction signal. Bleaching effects from photo-ionization significantly restrain image brightness scaling. We find that non-linear transient ion resonances can overcome this barrier if X-ray laser pulses are shorter than in most experiments. We compared snapshots from individual ≈ 100 nm Xe nanoparticles as a function of pulse duration and incoming X-ray fluence. Our experimental results and Monte Carlo simulations suggest that transient resonances can increase ionic scattering cross sections significantly beyond literature values. This provides a novel avenue towards substantial improvement of the spatial resolution in CDI in combination with sub-femtosecond temporal precision at the nanoscale.

47 OTHER INSTRUMENTATION↗

Real-time laser ultrasonic monitoring of laser-induced thermal processes

Abstract Intra- and inter-layer integrity of components fabricated with advanced manufacturing techniques, such as laser powder bed fusion, is dependent upon rapid heating, melting, and solidification processes. There is a need for new techniques to provide in situ feedback of these processes. Here a laser-based ultrasonic technique to probe thermal effects induced by a high-power continuous wave laser in titanium samples is described. Numerical simulations were performed to show that, for a spatially uniform heating beam, laser-induced surface acoustic waves are strongly influenced by surface heating conditions, are dispersive in the case of rapid heating, and that an abrupt velocity reduction happens upon the onset of surface melting. Furthermore, laser-based ultrasound experimental results which monitor the transient change of surface wave travel time associated with high power laser surface heating are provided. A pulsed laser is used to generate high frequency surface acoustic waves that propagate through the laser-heated region and are detected using a photorefractive crystal-based interferometer. Qualitative agreement is observed between theory and experiment with both showing a rapid reduction in the surface wave velocity at the onset of illumination and further decrease in surface wave velocity associated with melting. It is demonstrated that changes in the surface wave velocity can be used to track local heating and detect the onset of surface melting in real time.

36 MATERIALS SCIENCE↗

Charge exchange recombination spectroscopy at Wendelstein 7-X

The Charge Exchange Recombination Spectroscopy (CXRS) diagnostic has become a routine diagnostic on almost all major high temperature fusion experimental devices. For the optimized stellarator Wendelstein 7-X (W7-X), a highly flexible and extensive CXRS diagnostic has been built to provide high-resolution local measurements of several important plasma parameters using the recently commissioned neutral beam heating. This paper outlines the design specifics of the W7-X CXRS system and gives examples of the initial results obtained, to include typical ion temperature profiles for several common heating scenarios, toroidal flow and radial electric field derived from velocity measurements, beam attenuation via beam emission spectra, and normalized impurity density profiles under some typical plasma conditions.

47 OTHER INSTRUMENTATION↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

Monte Carlo N-Particle forward modeling for density reconstruction of double shell capsule radiographs

In the Double Shell Inertial Confinement Fusion concept, characterizing the shape asymmetry of imploding metal shells is vital for understanding energy-efficient compression and radiative losses of the thermonuclear fuel. The Monte Carlo N-Particle MCNP® code forward models radiography of Double Shell capsule implosions using the Advanced Radiographic Capability at the National Ignition Facility. A procedure is developed for using MCNP to reconstruct density profiles from the radiograph image intensity. For a given Double Shell imploding target geometry, MCNP radiographs predict image contrast, which can help guide experimental design. Finally, in future work, the calculated MCNP synthetic radiographs will be compared with experimental radiographs to determine the radial and azimuthal density profiles of the Double Shell capsules.

47 OTHER INSTRUMENTATION↗

Density of molten oxides measured in an aero-acoustic levitator

Knowing the thermophysical properties of high-temperature melts can aid the design of melt processes and validate atomic structural models, such as those used in studying glass formation. Property measurements on such melts are challenging, however, due to container-related contamination and heterogeneous nucleation. Containerless processing techniques that employ levitation can be used to avoid these obstacles. In that context, we demonstrate here the application of silhouette imaging to measure the density of molten oxides in an aero-acoustic levitation instrument (AAL). The AAL combines gas jet levitation with actively controlled acoustic positioning to enable full optical access to samples ca. 2–4 mm in diameter, which are laser beam heated and melted. The cross sections of molten drops are imaged using a monochromatic light source and narrowband-filtered camera. Melt volume is calculated from the cross sections and used to find density at several temperatures ranging 1530–1920 K, including up to 350 K of supercooling. We report densities for CaAl 2 O 4 , Ca 12 Al 14 O 33 , CaSiO 3 , their Fe 2 O 3 -bearing analogs, and 83TiO 2 -17RE 2 O 3 (RE = La or Nd). These provide important benchmarks of the capabilities, measurement uncertainties, and future outlook for this technique.

36 MATERIALS SCIENCE↗

Editorial announcements and information — ICFA Beam Dynamics Newsletter No. 81

This is a general information article of the ICFA Beam Dynamics Newsletter No. 81. Thus, it contains two forewords from the Editor-in-Chief and the issue editor, a workshop and conference report section, a recent Ph.D. thesis section, a forthcoming beam dynamics events section, and a section of announcements from the beam dynamics panel.

47 OTHER INSTRUMENTATION↗

Near-Threshold Photoemission from Graphene-Coated Cu(110)

In this article, the brightness of electron beams emitted from photocathode sources plays a critical role in determining the performance of x-ray free-electron lasers and ultrafast electron-diffraction applications. In order to achieve the maximum brightness, the electrons need to be emitted from a photocathode with the lowest-possible mean transverse energy (MTE). Recent investigations have shown that capping a Cu(110) photocathode with a monolayer of graphene can protect the quantum efficiency (QE) from long-term exposure to varying vacuum conditions. However, there have been no studies that investigate the effects that a monolayer of graphene has on the MTE. Here, we report on measurements of a graphene-coated Cu(110) single crystal near the photoemission threshold for room and liquid-nitrogen temperatures. At room temperature, a minimum MTE of 25 meV is measured at 295 nm. At liquid-nitrogen temperatures, a minimum MTE of 9 meV is measured at the photoemission threshold of 290 nm.

36 MATERIALS SCIENCE↗

Bayesian Optimization of a Free-Electron Laser

The Linac Coherent Light Source X-ray free-electron laser is a complex scienti c apparatus which changes con gurations multiple times per day, necessitating fast tuning strategies to reduce setup time for successive experiments. To this end, we employ a Bayesian approach to maximizing X- ray laser pulse energy by controlling groups of quadrupole magnets. A Gaussian process model provides probabilistic predictions for the machine response with respect to control parameters, enabling a balance of exploration and exploitation in the search for the global optimum. We show that the model parameters can be learned from archived scans, and correlations between devices can be extracted from the beam transport. Furthermore, the result is a sample-e cient optimization routine, combining both historical data and knowledge of accelerator physics to signi cantly outperform existing optimizers.

47 OTHER INSTRUMENTATION↗

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.

47 OTHER INSTRUMENTATION↗

Differently Structured Fabry-Perot Interferometers for Gas Pressure Monitoring

In this study, we present an experimental comparison of gas pressure sensors based on differently structured extrinsic Fabry-Pérot interferometers (FPIs). Different fabrication techniques were adopted to foster the practical realization of these sensors. A novel photonic crystal fiber (PCF) based FPI with an angle cleaved end face that enables gas to easily flow in and out of the cavity while also avoiding the mixed signal from the cascaded structure is also presented. We measured helium gas pressure from 0.1 MPa (atmospheric pressure) to 5 MPa at room temperature and obtained a gas pressure sensitivity coefficient of 0.5±0.01 nm/MPa. Furthermore, the gas pressure sensitivities are numerically analyzed to validate the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Sapphire Fiber Bragg Gratings Based Thermal Profiling of Submerged Entry Nozzles

This research focuses on the application of sapphire fiber Bragg gratings (FBGs) for instrumentation in submerged entry nozzles (SEN) within the steelmaking industry. The SEN is pivotal for transferring molten steel from a tundish to a mold, while preventing the infiltration of oxygen and nitrogen from the surrounding environment. Maintaining optimal flow conditions in the mold is crucial for ensuring casting process stability and maintaining high quality steel. Sapphire FBG sensors have been instrumented in SENs to enable distributed thermal mapping for monitoring the health of the SEN. The optical sensor comprises three cascaded sapphire FBGs inscribed using femtosecond laser technology into a one-meter-long sapphire crystalline fiber. The sensor underwent characterization in a laboratory setting up to 1600°C and was tested for long-term stability over 40 hours under extreme environmental conditions. The coupling between silica and sapphire fibers was investigated and implemented during sensor packaging. Here, the sensor successfully captured the pre-heat sequence of the SEN in real-world steelmaking operations. Compared to conventional thermocouples, sapphire FBG sensors demonstrated exceptional efficiency and precision. They offer potential benefits such as increased productivity, reduced energy consumption, and minimized carbon footprint in the steel industry.

Sapphire Fiber Bragg Grating↗

Line Emission Mapper: an X-ray probe mission concept to study the cosmic ecosystems and the physics of galaxy formation

In the 2020 Astrophysics Decadal Survey, the National Academies identified cosmic feedback and structure formation as a key question that should drive research in the upcoming decade. In response to this recommendation, NASA released a call for X-ray and IR probe-class missions, with a $\$$1B cost cap. The line emission mapper (LEM) is a mission concept designed in response to this call. LEM is a single-instrument X-ray telescope that consists of a Wolter–Schwarzschild type I X-ray optic with a 4 m focal length, coupled with an X-ray microcalorimeter with a 30' field of view (FoV), 15" angular resolution, and 2.5 eV energy resolution [full-width half maximum (FWHM)], with a 1.3 eV FWHM energy resolution central subarray. The high throughput X-ray mirror combined with the large FoV and excellent energy resolution allows for efficient mapping of extended emission-line dominated astrophysical objects from megaparsecs to sub-pc scales to study cosmic ecosystems and unveil the physical drivers of galaxy formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗