At least 757 records · Page 42

Project PARAS: Phased array radio astronomy from space

An orbiting radio telescope is proposed which, when operated in a very long baseline interferometry (VLBI) scheme, would allow higher than currently available angular resolution and dynamic range in the maps and the ability to observe rapidly changing astronomical sources. Using passive phased array technology, the proposed design consists of 656 hexagonal modules forming a 150-m diameter antenna dish. Each observatory module is largely autonomous, having its own photovoltaic power supply and low-noise receiver and processor for phase shifting. The signals received by the modules are channeled via fiber optics to the central control computer in the central bus module. After processing and multiplexing, the data are transmitted to telemetry stations on the ground. The truss frame supporting each observatory panel is a novel hybrid structure consisting of a bottom graphite/epoxy tubular triangle and rigidized inflatable Kevlar tubes connecting the top observatory panel and the bottom triangle. Attitude control and station keeping functions will be performed by a system of momentum wheels in the bus and four propulsion modules located at the compass points on the periphery of the observatory dish. Each propulsion module has four monopropellant thrusters and four hydrazine arcjets, the latter supported by either a photovoltaic array or a radioisotope thermoelectric generator. The total mass of the spacecraft is about 20,500 kg.

Nuss, Kenneth↗

High Temperature Calibration Furnace System user's guide

The High Temperature Calibration Furnace System (HTCFS) was developed by Summitec Corporation. It is a high precision instrument providing a constant temperature which can be used to calibrate high temperature thermocouples. Incorporating the many recent technological advances from the fields of optical fiber thermometry, material science, computer systems interfacing, and process control, the engineers at Summitec Corporation have been able to create a system that can reach a steady operating temperature of 1700 C. The precision for the system requires the measurement of temperature to be within 1 C in two hours and within 2 C in 24 hours. As documented, the experimental result shows that this system has been able to stay within .5 C in 5 hours. No other systems commercially available have been able to achieve such high temperature precision. This manual provides an overview of the system design, instructions for instrument setup, and operation procedures. Also included are a vendor list and the source codes for the custom-designed software.

Source record↗

Deep galaxy counts in the K band with the Kech telescope

We present deep galaxy counts in the K (lambda 2.2 micrometer) band, obtained at the W. M. Kech 10 m telescope. The data reach limiting magnitudes K approximately 24 mag, about 5 times deeper than the deepest published K-band images to date. The counts are performed in three small (approximately 1 min), widely separated high-latitude fields. Extensive Monte Carlo tests were used to derive the comleteness corrections and minimize photometric biases. The counts continue to rise, with no sign of a turnover, down to the limits of our data, with the logarithmic slope of d log N/dm = 0.315 +/- 0.02 between K = 20 and 24 mag. This implies a cumulative surface density of approximately 5 x 10(exp 5) galaxies/sq deg, or approximately 2 x 10(exp 10) over the entire sky, down to K = 24 mag. Our counts are in good agreement with, although slightly lower than, those from the Hawaii Deep Survey by Cowie and collaborators; the discrepancies may be due to the small differences in the aperture corrections. We compare our counts with some of the available theoretical predictions. The data do not require models with a high value of Omega(sub 0), but can be well fitted by models with no (or little) evolution, and cosmologies with a low value of Omega(sub 0). Given the uncertainties in the models, it may be premature to put useful constrains on the value of Omega(sub 0) from the counts alone. Optical-to-IR colors are computed, using CCD data obtaind previously at Palomar. We find a few red galaxies with (r-K) approximately greater than 5 mag, or (i-K) approximately greater than 5 mag; these may be ellipticals at z approximately 1. While the redshift distribution of galaxies in our counts is still unknown, the flux limits reached would allow us to detect unobscured L(sub *) galaxies out to substantial redshifts (z greater than 3?).

Djorgovski, S.↗

Airborne lidar observations of smoke haze during SCAR-B 1995

The Smoke, Clouds, Aerosol, and Radiation Brazil(SCAR-B) field campaign was conducted to study the effects that widespread and persistent biomass burning have upon radiative and chemical processes in the atmosphere. The radiative transfer characteristics of the atmosphere are altered by the introduction of particulate and gaseous materials which are the products of the combustion of vegetative material at ground level. These substances are transported and distributed horizontally and vertically by atmospheric dynamical processes which may be perturbed by the heat energy from the fires. As the pollutants disperse, their physical and chemical properties change substantially. A complete description of the effects of smoke requires that the evolution back to the natural situation be fully examined. A most important component of smoke haze investigation is finding its vertical and horizontal distribution in relation to the driving factors of dynamics and the related horizontal transport. In this presentation, we employ data from the Cloud Lidar System(CLS), carried aboard the NASA ER-2 aircraft, to provide a unique view of the particulate or aerosol loading produced by fires, especially with regard to the geometrical distribution of the aerosols in the vertical plane. The lidar has the ability to measure aerosol optical properties in a continuous fashion at quite fine vertical and horizontal resolution. The results from the lidar provide measurements that are largely independent of influences that corrupt passive instruments and thus it can serve to corroborate their results. The extended horizontal and vertical range of lidar results can also augment ground based and airborne in situ measurements which have limited horizontal and vertical scope. We present the results of our analysis of CLS observations taken during the SCAR-B field campaign. Observations of the the aerosol optical thickness from the Aerosol Robotic Network(AERONET) of solar photometers are employed in conjunction with CLS data to derive extinction to backscatter ratio values which are used to convert the lidar backscatter coefficient into extinction coefficient. The extinction coefficient is integrated vertically to find aerosol optical thickness along ER-2 flight tracks. We use images of the CLS derived extinction coefficient to depict its horizontal and vertical distribution. Multispectral photometer optical thickness is used to compute the Angstrom exponent. With these, we examine the hypothesis that the values of extinction to backscatter ratio can be related to the Anstrom coefficient since both of these would be a function of the refractive index and size distribution of the aerosols.

Hart, William D.↗

Thermal Balance in Dense Molecular Clouds: Radiative Cooling Rates and Emission-Line Luminosities

We consider the radiative cooling of fully shielded molecular astrophysical gas over a wide range of temperatures ( 10 K < T < 2500 K) and H2 densities ( 10(exp 3)/cc < n(H2) < 10(exp 10)/cc). Our model for the radiative cooling of molecular gas includes a detailed treatment of the interstellar chemistry that determines the abundances of important coolant molecules, and a detailed treatment of the excitation of the species H2, CO, H2O, HCl, O2, C, O, and their isotopic variants where important. We present results for the total radiative cooling rate and for the cooling rate due to individual coolant species, as a function of the gas temperature, density, and optical depth. We have also computed the individual millimeter, submillimeter, and far-infrared line strengths that contribute to the total radiative cooling rate, and we have obtained example spectra for the submillimeter emission expected from molecular cloud cores. Many of the important cooling lines will be detectable using the Infrared Space Observatory and the Submillimeter Wave Astronomy Satellite.

Neufeld, David A.↗

Multiwavelength Modeling of Nove Atmospheres

LMC 1988 #1 was a slow, CO type, dust forming classical nova. It was the first extragalactic nova to be observed with the IUE satellite. We have successfully fitted observed ultraviolet and optical spectra of LMC 1988 #1 taken within the first two months of its outburst (when the atmosphere was still optically thick) with synthetic spectra computed using PHOENIX nova model atmospheres. The synthetic spectra reproduce most of the features seen in the spectra and provide V band magnitudes consistent with the observed light curve. The fits are improved by increasing the CNO abundances to 10 times the solar values. The bolometric luminosity of LMC 1988 #1 was approximately constant at 2 x 10(exp 38) ergs per second at a distance of 47.3 kpc for the first 2 months of the outburst until the formation of the dust shell.

Huschildt, P. H.↗

Support of Integrated Health Management (IHM) through Automated Analyses of Flowfield-Derived Spectrographic Data

Flow-field analysis techniques under continuing development at NASA's Marshall Space Flight Center are the foundation for a new type of health monitoring instrumentation for propulsion systems and a vast range of other applications. Physics, spectroscopy, mechanics, optics, and cutting-edge computer sciences merge to make recent developments in such instrumentation possible. Issues encountered in adaptation of such a system to future space vehicles, or retrofit in existing hardware, are central to the work. This paper is an overview of the collaborative efforts results, current efforts, and future plans.

Patrick, Marshall C.↗

Using Science Driven Technologies for the Defense and Security Applications

For the past three decades, Earth science remote sensing technologies have been providing enormous amounts of useful data and information in broadening our understanding of our home planet as a system. This research, as it has expanded our learning process, has also generated additional questions. This has further resulted in establishing new science requirements, which have culminated in defining and pushing the state-of-the-art technology needs. NASA s Earth science program has deployed 18 highly complex satellites, with a total of 80 sensors, so far and is in a process of defining and launching multiple observing systems in the next decade. Due to the heightened security alert of the nation, researchers and technologists are paying serious attention to the use of these science driven technologies for dual use. In other words, how such sophisticated observing and measuring systems can be used in detecting multiple types of security concerns with a substantial lead time so that the appropriate law enforcement agencies can take adequate steps to defuse any potential risky scenarios. This paper examines numerous NASA technologies such as laser/lidar systems, microwave and millimeter wave technologies, optical observing systems, high performance computational techniques for rapid analyses, and imaging products that can have a tremendous pay off for security applications.

Habib, Shahid↗

GOES Satellite Data Validation Via Hand-held 4 LED Sun Photometer at Norfolk State University

Sun photometry is a passive means of measuring a quantity of light radiation. The GIFTS- IOMI/GLOBE Water Vapor/Haze Sun photometer contains four light emitting diodes (LEDs), which are used to convert photocurrent to voltage. The intensity of the incoming and outgoing radiation as detected on the Earth s surface can be affected by aerosols and gases in the atmosphere. The focus of this research is primarily on aerosol and water vapor particles that absorb and reemit energy. Two LEDs in the photometer correspond to light scattered at 530 nm (green spectrum) and 620 nm (red spectrum). They collect data pertaining to aerosols that scatter light. The other two LEDs detect the light scattered by water vapor at wavelengths of 820 nm and 920 nm. The water vapor measurements will be compared to data collected by the Geostationary Observation Environmental Satellite (GOES). Before a comparison can be made, the extraterrestrial constant (ET), which is intrinsic to each sun photometer, must be measured. This paper will present determination of the ET constant, from which the aerosol optical thickness (AOT) can be computed for comparison to the GOES satellite to ascertain the reliability of the sun photometer.

Reynolds, Arthur, Jr.↗

Biological imaging spectroscopy

Improved detectors, new electro-optical devices and vastly improved computational power for data analysis have fueled the recent interest in combining biology and spectroscopy.

biophotonics imaging spectroscopy↗

NASA Tech Briefs, May 2004

Topics include: Embedded Heaters for Joining or Separating Plastic Parts; Curing Composite Materials Using Lower-Energy Electron Beams; Aluminum-Alloy-Matrix/Alumina-Reinforcement Composites; Fibrous-Ceramic/Aerogel Composite Insulating Tiles; Urethane/Silicone Adhesives for Bonding Flexing Metal Parts; Scalable Architecture for Multihop Wireless ad Hoc Networks; Improved Thermoplastic/Iron-Particle Transformer Cores; Cooperative Lander-Surface/Aerial Microflyer Missions for Mars Exploration Dual-Frequency Airborne Scanning Rain Radar Antenna System Eight-Channel Continuous Timer Reduction of Phase Ambiguity in an Offset-QPSK Receiver Ambient-Light-Canceling Camera Using Subtraction of Frames Lightweight, Flexible, Thin, Integrated Solar-Power Packs Windows(Registered Trademark)-Based Software Models Cyclic Oxidation Behavior Software for Analyzing Sequences of Flow-Related Images Improved Ball-and-Socket Docking Mechanism Two-Stage Solenoid Ordered Nanostructures Made Using Chaperonin Polypeptides Low-Temperature Plasma Functionalization of Carbon Nanotubes Improved Cryostat for Cooling a Wide Panel Current Pulses Momentarily Enhance Thermoelectric Cooling Hand-Held Color Meters Based on Interference Filters Calculating Mass Diffusion in High-Pressure Binary Fluids Fresnel Lenses for Wide-Aperture Optical Receivers Increasing Accuracy in Computed Inviscid Boundary Conditions Higher-Order Finite Elements for Computing Thermal Radiation Radar for Monitoring Hurricanes from Geostationary Orbit Time-Transfer System for Two Orbiting Spacecraft

Source record↗

Atomic Data for the CHIANTI Database

The CHIANTI spectral code consists of an atomic database and a suite of computer programs to calculate the optically thin spectrum of astrophysical objects and to carry out spectroscopic plasma diagnostics. The database includes atomic energy levels, wavelengths, radiative transition rates, collisional excitation, ionization and recombination rate coefficients, as well as data to calculate free-free, free-bound and two-photon continuum emission. In recent years, we have been pursuing a program to calculate atomic data for ions whose lines have been observed in astrophysical spectra but have been neglected in the literature, and to provide CHIANTI with all the data necessary to predict line intensities. There are two types of such ions: those for which calculations are available for low-energy configurations but not for high-energy configurations (i.e., C-like, N-like, O-like systems), and ions that have never or only seldom been studied. This poster will summarize the current status of this project and indicate the future activities .

Bhatia, Anand K.↗

Vision Based Autonomous Robotic Control for Advanced Inspection and Repair

The advanced inspection system is an autonomous control and analysis system that improves the inspection and remediation operations for ground and surface systems. It uses optical imaging technology with intelligent computer vision algorithms to analyze physical features of the real-world environment to make decisions and learn from experience. The advanced inspection system plans to control a robotic manipulator arm, an unmanned ground vehicle and cameras remotely, automatically and autonomously. There are many computer vision, image processing and machine learning techniques available as open source for using vision as a sensory feedback in decision-making and autonomous robotic movement. My responsibilities for the advanced inspection system are to create a software architecture that integrates and provides a framework for all the different subsystem components; identify open-source algorithms and techniques; and integrate robot hardware.

sensory feedback↗

Heads up display for the Flight Simulator for Advanced Aircraft (FSAA)

A heads-up flight director display designed for a V/STOL lift-fan transport simulation study is described. The pilot's visual flight scene had the heads-up display optically superimposed over the usual out-the-window, video flight scene. The flight director display required the development and integration of a flexible, programmable display generator, graphics assembler, display driver, computer interface system, and special collimating optics for the pilot's flight scene. The optical overlay was realistic because both scenes appeared at optical infinity, and the flexibility of this display device establishes its value as a research tool for use in future flight simulation programs.

Brocker, D. H.↗

Electronic properties and optical spectra of donor–acceptor conjugated organic polymers

Organic semiconductors based on conjugated donor-acceptor (D–A) polymers are a unique platform for electronic, spintronic, and energy-harvesting devices. Understanding the electronic structure of D–A polymers with a small band gap is essential for developing next-generation technologies. Here, we investigate the electronic structure and optical spectra of cyclopentadithiophene-based closed/open-shell D–A polymers using density functional theory and the Bethe–Salpeter equation based on G 0 W 0 approximation. We explored the role of different acceptor units and chemical substitutions on the structural changes and, more importantly, electronic, optical, and dielectric behavior. We found that the computed first exciton peak of the polymers agreed well with the available experimentally measured optical gap. Furthermore, D–A polymers with open-shell character display higher dielectric constant than the closed-shell polymers. We show that the exceptional performance of polycyclopentadithiophene-thiophenylthiadiazoloquinoxaline (PCPDT-TTQ) as a scalable n-type material for Faradaic supercapacitors can be partly ascribed to its elevated dielectric constant. Consequently, these D–A polymers, characterized by their high dielectric constants, exhibit significant potential for various applications, including energy storage, organic electronics, and the production of dielectric films.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of blended rolled edge reflectors using numerical UTD

The uniform geometrical theory of diffraction (UTD) concept is used to predict the scattered fields in the target zones of compact-range blended rolled-edge reflectors. Since the necessary diffraction coefficients are not known in a closed form, a numerical method to calculate the diffraction coefficients is described. In the numerical method, the problem is reduced to two dimensions, and physical optics line integration is used to compute the diffraction coefficients. Thus, the method is computationally efficient. The method is used to analyze two compact-range reflectors. The results obtained using the numerical UTD show good agreement with the scattered fields obtained using a corrected physical optics surface integration.

Ellingson, Steven W.↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

N-type mercury-cadmium-telluride photoconductors in optical heterodyne communication systems.

Discussion of the performance of a photoconductive (Hg,Cd)Te detector/mixer in a carbon dioxide laser heterodyne communication system. The utility of computer simulation of the performance of an optical heterodyne detector/mixer is demonstrated. Certain unusual properties of this device are pointed out that, while having a substantial impact on device performance, have received little previous attention.

Cohen, S. C.↗