Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Objectives”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Ion velocity distributions in the sheath and presheath of a biased object in plasma

Ion velocity distributions in the vicinity of a spherical object with a negative potential with respect to collisionless, source-free plasma are studied with three-dimensional numerical simulations. The ion dynamics around the object leads to distorted radial velocity distributions in the presheath and the sheath edge region. Far in the sheath, an increase in the thermal velocity in the radial direction is observed. Different potentials of the object, ion temperatures, and ion masses are considered, as well as the role of spatial and temporal resolutions in laboratory measurements of ion velocity distributions. The simulations are carried out with the DiP3D, a three-dimensional particle-in-cell numerical code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication of nanoscale patterns in lithium fluoride crystal using a 13.5 nm Schwarzschild objective and a laser produced plasma source

Lithium fluoride (LiF) crystal is a radiation sensitive material widely used as EUV and soft x-ray detector. The LiF-based detector has high resolution, in principle limited by the point defect size, large field of view, and wide dynamic range. Using LiF crystal as an imaging detector, a resolution of 900 nm was achieved by a projection imaging of test meshes with a Schwarzschild objective operating at 13.5 nm. In addition, by imaging of a pinhole illuminated by the plasma, an EUV spot of 1.5 {mu}m diameter in the image plane of the objective was generated, which accomplished direct writing of color centers with resolution of 800 nm. In order to avoid sample damage and contamination due to the influence of huge debris flux produced by the plasma source, a spherical normal-incidence condenser was used to collect EUV radiation. Together with a description of experimental results, the development of the Schwarzschild objective, the influence of condenser on energy density and the alignment of the imaging system are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pure electron plasmas confined for 90 ms in a stellarator without electron sources or internal objects

We report on the creation and up to 90 ms sustainment of pure electron plasmas confined in a stellarator without internal objects. Injection of positrons into such plasmas is expected to lead to the creation of the first electron-positron plasma experiments. These newly created plasmas will also allow a study of pure electron plasmas without the perturbing presence of internal objects. The plasmas were created by thermionic emission of electrons from a heated, biased filament that was retracted in 20 ms. The confinement of these transient plasmas is different from that of steady state plasmas with internal objects and emissive filaments, and is generally shorter, limited by ion buildup. The decay time is increased by lowering the neutral pressure, lowering the electron plasma temperature, or operating with neutrals with high ionization energies (helium). These findings are all consistent with ion accumulation being the cause for the shorter than expected confinement times. The magnetic field strength also moderately increases the decay times. The deleterious effect of ions is not expected to imply a similar deleterious effect when introducing positrons, but it implies that ion accumulation must be avoided also in an electron-positron experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Invited Review Article: Methods for imaging weak-phase objects in electron microscopy

Contrast has traditionally been produced in electron-microscopy of weak phase objects by simply defocusing the objective lens. There now is renewed interest, however, in using devices that apply a uniform quarter-wave phase shift to the scattered electrons relative to the unscattered beam, or that generate in-focus image contrast in some other way. Renewed activity in making an electron-optical equivalent of the familiar “phase-contrast” light microscope is based in part on the improved possibilities that are now available for device microfabrication. There is also a better understanding that it is important to take full advantage of contrast that can be had at low spatial frequency when imaging large, macromolecular objects. In addition, a number of conceptually new phase-plate designs have been proposed, thus increasing the number of options that are available for development. The advantages, disadvantages, and current status of each of these options is now compared and contrasted. Experimental results that are, indeed, superior to what can be accomplished with defocus-based phase contrast have been obtained recently with two different designs of phase-contrast aperture. Nevertheless, extensive work also has shown that fabrication of such devices is inconsistent, and that their working lifetime is short. The main limitation, in fact, appears to be electrostatic charging of any device that is placed into the electron diffraction pattern. The challenge in fabricating phase plates that are practical to use for routine work in electron microscopy thus may be more in the area of materials science than in the area of electron optics.

36 MATERIALS SCIENCE↗

An algorithm to unveil the inner structure of objects concealed by beam divergence in radiographic image acquisition systems

Two main parameters rule the performance of an Image Acquisition System, namely, spatial resolution and contrast. For radiographic systems using cone beam arrangements, the farther the source, the better the resolution, but the contrast would diminish due to the lower statistics. A closer source would yield a higher contrast but it would no longer reproduce the attenuation map of the object, as the incoming beam flux would be reduced by unequal large divergences and attenuation factors. This work proposes a procedure to correct these effects when the object is comprised of a hull - or encased in it - possessing a shape capable to be described in analytical geometry terms. Such a description allows the construction of a matrix containing the attenuation factors undergone by the beam from the source until its final destination at each coordinate on the 2D detector. Each matrix element incorporates the attenuation suffered by the beam after its travel through the hull wall, as well as its reduction due to the square of distance to the source and the angle it hits the detector surface. When the pixel intensities of the original image are corrected by these factors, the image contrast, reduced by the overall attenuation in the exposure phase, are recovered, allowing one to see details otherwise concealed due to the low contrast. In order to verify the soundness of this approach, synthetic images of objects of different shapes, such as plates and tubes, incorporating defects and statistical fluctuation, have been generated, recorded for further comparison and afterwards processed to improve their contrast. The developed algorithm which, generates processes and plots the images has been written in Fortran 90 language. As the resulting final images exhibit the expected improvements, it therefore seemed worthwhile to carry out further tests with actual experimental radiographies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Image-based tracking system for vibration measurement of a rotating object using a laser scanning vibrometer

An image-based tracking system using laser scanning vibrometer is developed for vibration measurement of a rotating object. The proposed system unlike a conventional one can be used where the position or velocity sensor such as an encoder cannot be attached to an object. An image processing algorithm is introduced to detect a landmark and laser beam based on their colors. Then, through using feedback control system, the laser beam can track a rotating object.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long working distance objective lenses for single atom trapping and imaging

We present a pair of optimized objective lenses with long working distances of 117 mm and 65 mm, respectively, that offer diffraction limited performance for both Cs and Rb wavelengths when imaging through standard vacuum windows. The designs utilise standard catalog lens elements to provide a simple and cost-effective solution. Objective 1 provides NA = 0.175 offering 3 μm resolution whilst objective 2 is optimized for high collection efficiency with NA = 0.29 and 1.8 μm resolution. This flexible design can be further extended for use at shorter wavelengths by simply re-optimising the lens separations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online multi-objective particle accelerator optimization of the AWAKE electron beam line for simultaneous emittance and orbit control

Multi-objective optimization is important for particle accelerators where various competing objectives must be satisfied routinely such as, for example, transverse emittance vs bunch length. We develop and demonstrate an online multi-time scale multi-objective optimization algorithm that performs real time feedback on particle accelerators. We demonstrate the ability to simultaneously minimize the emittance and maintain a reference trajectory of a beam in the electron beamline in CERN’s Advanced Proton Driven Plasma Wakefield Acceleration Experiment.

43 PARTICLE ACCELERATORS↗

Self-imaging of transparent objects and structures in focusing of spatially phase-modulated laser radiation into a weakly absorbing medium

Self-imaging of transparent objects and structures in focusing of a spatially phase-modulated laser beam into an extended weakly absorbing medium is described. The laser power level that is necessary for effective imaging corresponds to the illuminating beam power when thermal self-defocusing starts evolving in the medium. The effect can be described in terms of the ideology of Zernike's classical phase-contrast method. Edge enhancement in visualised images of transparent objects is experimentally demonstrated. Self-imaging of a microscopic object in the form of transparent letters and long-lived refractive-index fluctuations in liquid glycerol is shown. Due to the adaptivity of the process under consideration, unlike the classical case, self-imaging occurs also in the situations where a beam is displaced (undergoes random walk) as a whole in the Fourier plane, for example, in the presence of thermal flows. (image processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental stand for studying the impact of laser-accelerated protons on biological objects

An original experimental stand is presented, aimed at studying the impact of high-energy protons, produced by the laser-plasma interaction at a petawatt power level, on biological objects. In the course of pilot experiments with the energy of laser-accelerated protons up to 25 MeV, the possibility is demonstrated of transferring doses up to 10 Gy to the object of study in a single shot with the magnetic separation of protons from parasitic X-ray radiation and fast electrons. The technique of irradiating the cell culture HeLa Kyoto and measuring the fraction of survived cells is developed. The ways of optimising the parameters of proton beams and the suitable methods of their separation with respect to energy and transporting to the studied living objects are discussed. The construction of the stand is intended for the improvement of laser technologies for hadron therapy of malignant neoplasms. (extreme laser radiation: physics and fundamental applications)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo simulation of a biological object with optical coherent tomography structural images using a voxel-based geometry of a medium

We describe a Monte Carlo algorithm for simulating an interference signal and constructing a structural image of a biological object using optical coherent tomography (OCT). The algorithm is specific in that the object geometry is described by using a three-dimensional array of voxels combined into parallelograms, and the border cross checking is carried out by using an improved Smith algorithm. The geometry of the simulated object is reconstructed based on the structure of real biological tissues obtained by OCT. The algorithm efficiency is estimated by comparing experimental and corresponding simulated images of a subcutaneous blood vessel and upper layer of human skin in vivo . (biophotonics)

60 APPLIED LIFE SCIENCES↗

Investigation of the effect of noise parameters of a 3D lidar on the error in estimating relief signatures of distant objects from 2D field intensity distributions of reflected radiation

We consider the influence of noise parameters of a 3D lidar and external background radiation on the error in estimating the relief signatures of distant objects from 2D field intensity distributions of the reflected radiation. A physical and mathematical model is developed to analyse the effect of noise. The dependence of the error in estimating the relief signatures at various signal-to-noise ratios is investigated taking into account the parameters of real multi-element photodetectors (MEPDs). The obtained results indicate the possibility of evaluating relief signatures of distant objects with high accuracy based on standard MEPDs simultaneously for a large number of points on the object’s surface with a signal-to-noise ratio of more than 4. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Objective Optimization of Uranium Target Assembly–3: A Comparison of Genetic and Traditional Methods

Commonly produced as a byproduct of uranium fission, 99 Mo is a key medical isotope that is in high demand in the United States. An international goal is to switch from medical isotope production technologies that require highly enriched uranium to medical isotope production technologies that require only low-enriched uranium. Niowave Inc. is contributing to this goal by developing an accelerator-driven subcritical assembly called the Uranium Target Assembly (UTA). This work compares the performance of Dakota’s Multi-Objective Genetic Algorithm (MOGA) against traditional sensitivity analysis in the neutronic optimization of the UTA-3 system. The design objectives are k-eigenvalue (k eff ) and natural uranium fission power, which are directly correlated with the amount of 99 Mo produced. Dakota:MOGA did not perform as well as human engineering ingenuity in optimization studies with high numbers of input parameters, such as fuel rod type selection and fuel rod placement. However, Dakota:MOGA did outperform traditional sensitivity analysis in optimization studies with fewer than 20 parameters and revealed the degree to which each parameter influences the optimal design space for k eff and natural uranium fission power (to a lesser extent). As the design model became more complex in the final stage of design, the computational resources required to calculate the design objective values in the Monte Carlo N-Particle transport code from selected input parameter combinations limited Dakota:MOGA’s performance, and, unfortunately, human intervention was required to discern the optimal design space. In conclusion, future work will attempt to reduce computational resource constraints by incorporating areduced-order neutronics model into the optimization cycle.

Accelerator-driven systems↗

Principles of stereo reconstruction of aerial objects using stationary cameras

An overview is given here of the principles and mathematics of stereo reconstruction of objects in the sky using stationary cameras with an emphasis on meteorological applications. Through its Atmospheric Radiation Measurement program, the Department of Energy has operated stereo-photogrammetric cameras since 2017 as part of an effort to measure the life-cycle properties of clouds. At the core of that technology is stereo reconstruction, which calculates the real-world position of an object from the location of the object’s image in two cameras’ photographs. Here, stereo reconstruction is stripped down to its basic elements and presented using conventions tailored to applications in atmospheric science. In addition, the resulting equations are used to illustrate the high sensitivity of reconstructed cloud positions to errors in the cameras’ Euler angles. The interested reader will find here a self-contained guide to performing stereo reconstructions using distortion-corrected images from a pair of calibrated, stationary cameras, as well as a demonstration of the need for high accuracy in the measurement of camera properties and orientations.

47 OTHER INSTRUMENTATION↗

SUPER-KEPLERIAN FREQUENCIES IN ACCRETION DISKS. IMPLICATIONS FOR MASS AND SPIN MEASUREMENTS OF COMPACT OBJECTS FROM X-RAY VARIABILITY STUDIES

The detection of fast quasi-periodic variability from accreting black holes and neutron stars has been used to constrain their masses, radii, and spins. If the observed oscillations are linear modes in the accretion disks, then bounds can be placed on the properties of the central objects by assuming that these modes are locally sub-Keplerian. If, on the other hand, the observed oscillations correspond to nonlinear resonances between disk modes, then the properties of the central objects can be measured by assuming that the resonant modes are excited at the same radial annulus in the disk. In this paper, we use numerical simulations of vertically integrated, axisymmetric hydrodynamic accretion disks to provide examples of situations in which the assumptions implicit in both methods are not satisfied. We then discuss our results for the robustness of the mass and spin measurements of compact objects from variability studies.

79 ASTRONOMY AND ASTROPHYSICS↗

MICROLENSING-BASED ESTIMATE OF THE MASS FRACTION IN COMPACT OBJECTS IN LENS GALAXIES

We estimate the fraction of mass that is composed of compact objects in gravitational lens galaxies. This study is based on microlensing measurements (obtained from the literature) of a sample of 29 quasar image pairs seen through 20 lens galaxies. We determine the baseline for no microlensing magnification between two images from the ratios of emission line fluxes. Relative to this baseline, the ratio between the continua of the two images gives the difference in microlensing magnification. The histogram of observed microlensing events peaks close to no magnification and is concentrated below 0.6 mag, although two events of high magnification, DELTAm approx 1.5, are also present. We study the likelihood of the microlensing measurements using frequency distributions obtained from simulated microlensing magnification maps for different values of the fraction of mass in compact objects, alpha. The concentration of microlensing measurements close to DELTAm approx 0 can be explained only by simulations corresponding to very low values of alpha (10% or less). A maximum likelihood test yields alpha = 0.05{sup +0.09}{sub -0.03} (90% confidence interval) for a quasar continuum source of intrinsic size r{sub s{sub 0}}approx2.6x10{sup 15} cm. This estimate is valid in the 0.1-10 M {sub sun} range of microlens masses. We study the dependence of the estimate of alpha with r{sub s{sub 0}}, and find that alpha approx< 0.1 for r{sub s{sub 0}}approx<1.3x10{sup 16} cm. High values of alpha are possible only for source sizes much larger than commonly expected (r{sub s{sub 0}}>>2.6x10{sup 16} cm). Regarding the current controversy about Milky Way/LMC and M31 microlensing studies, our work supports the hypothesis of a very low content in MACHOS (Massive Compact Halo Objects). In fact, according to our study, quasar microlensing probably arises from the normal star populations of lens galaxies and there is no statistical evidence for MACHOS in the dark halos.

79 ASTRONOMY AND ASTROPHYSICS↗

MULTIPLE SCATTERING POLARIZATION OF SUBSTELLAR-MASS OBJECTS: T DWARFS

While there have been multiple observational programs aimed at detecting linear polarization of optical radiation emitted by ultracool dwarfs, there has been comparatively less rigorous theoretical analysis of the problem. The general expectation has been that the atmospheres of those substellar-mass objects with condensate clouds would give rise to linear polarization due to scattering. Because of rotation-induced non-sphericity, there is expected to be incomplete cancellation of disk-integrated net polarization and thus a finite polarization. For cloudless objects, however, only molecular Rayleigh scattering will contribute to any net polarization and this limit has not been well studied. Hence in this paper we present a detailed multiple scattering analysis of the polarization expected from those T-dwarfs whose spectra show absence of condensates. For this, we develop and solve the full radiative transfer equations for linearly polarized radiation. Only atomic and molecular Rayleigh scattering are considered to be the sources of polarization. We compute the local polarization at different angular directions in a plane-parallel atmosphere calculated for the range of effective temperatures of T dwarfs and then average over the whole surface of the object. The effects of gravity and limb darkening as well as rotation induced non-sphericity are included. It is found that the amount of polarization decreases with the increase in effective temperature. It is also found that significant polarization at any local point in the atmosphere arises only in the optical (B band). However, the disk integrated polarization-even in the B band-is negligible. Hence we conclude that, unlike the case for cloudy L dwarfs, polarization of cloudless T dwarfs by atomic and molecular scattering may not be detectable. In the future we will extend this work to cloudy L and T dwarf atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

IDENTIFICATION OF THE EARLY FERMI/LAT GAMMA-RAY BRIGHT OBJECTS WITH EXTRAGALACTIC VLBI SOURCES

A list of 205 gamma-ray strong objects was reported recently as a result of a three-month integration with the Large Area Telescope on board the Fermi Gamma-Ray Space Telescope. We attempted identification of these objects, cross-correlating the gamma-ray positions with very long baseline interferometry (VLBI) positions of a large all-sky sample of extragalactic radio sources selected on the basis of their parsec-scale flux density. The original associations reported by the Fermi team are confirmed, and six new identifications are suggested. A Monte Carlo analysis shows that the fraction of chance associations in our analysis is less than 5%, and confirms that the vast majority of gamma-ray bright extragalactic sources are radio-loud blazars with strong parsec-scale jets. A correlation between the parsec-scale radio and gamma-ray flux is supported by our analysis of a complete VLBI flux-density-limited sample of extragalactic jets. The effectiveness of using a VLBI catalog to find associations between gamma-ray detections and compact extragalactic radio sources, especially near the Galactic plane, is demonstrated. It is suggested that VLBI catalogs should be used for future identification of Fermi/LAT objects.

79 ASTRONOMY AND ASTROPHYSICS↗