SEARCH · Engineering Papers
Results for “OPTICS DESIGN”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Phase-contrast tomography at the nanoscale using hard x rays
Synchrotron-based full-field tomographic microscopy established itself as a tool for noninvasive investigations. Many beamlines worldwide routinely achieve micrometer spatial resolution while the isotropic 100-nm barrier is reached and trespassed only by few instruments, mainly in the soft x-ray regime. We present an x-ray, full-field microscope with tomographic capabilities operating at 10 keV and with an isotropic resolution of 144 nm. Custom-designed optical components allow for ideal, aperture-matched sample illumination and very sensitive phase contrast imaging. We show here that the instrument has been successfully used for the nondestructive, volumetric investigation of single cells.
Designer Spatial Control of Interactions in Ultracold Gases
Designer optical control of interactions in ultracold atomic gases has wide applications, from creating new quantum phases to modeling the physics of black holes. We demonstrate wide tunability and spatial control of interactions in a two-component cloud of 6 Li fermions, using electromagnetically induced transparency. With two control fields detuned ≃1.5 THz from atomic resonance, megahertz changes in the frequency of one optical beam tune the measured scattering length over the full range achieved by magnetic control, with negligible (10 –6 ) effect on the net optical confining potential. A 1D “sandwich” of resonantly and weakly interacting regions is imprinted on the trapped cloud and broadly manipulated with sub-MHz frequency changes. Here, all of the data are in excellent agreement with our continuum-dressed state theoretical model of optical control, which includes both the spatial and momentum dependence of the scattering amplitude.
First-principles investigation of near-field energy transfer between localized quantum emitters in solids
We present a predictive and general approach to investigate near-field energy transfer processes between localized defects in semiconductors, which couples first-principles electronic structure calculations and a nonrelativistic quantum electrodynamics description of photons in the weak-coupling regime. The approach is general and can be readily applied to investigate broad classes of defects in solids. We apply our approach to investigate an exemplar point defect in an oxide, the F center in MgO, and we show that the energy transfer from a magnetic source, e.g., a rare-earth impurity, to the vacancy can lead to spin nonconserving long-lived excitations that are dominant processes in the near field, at distances relevant to the design of photonic devices and ultrahigh dense memories. We also define a descriptor for coherent energy transfer to predict geometrical configurations of emitters to enable long-lived excitations, that are useful to design optical memories in semiconductor and insulators. Published by the American Physical Society 2024
JBluIce-EPICS control system for macromolecular crystallography.
The trio of macromolecular crystallography beamlines constructed by the General Medicine and Cancer Institutes Collaborative Access Team (GM/CA-CAT) in Sector 23 of the Advanced Photon Source (APS) have been in growing demand owing to their outstanding beam quality and capacity to measure data from crystals of only a few micrometres in size. To take full advantage of the state-of-the-art mechanical and optical design of these beamlines, a significant effort has been devoted to designing fast, convenient, intuitive and robust beamline controls that could easily accommodate new beamline developments. The GM/CA-CAT beamline controls are based on the power of EPICS for distributed hardware control, the rich Java graphical user interface of Eclipse RCP and the task-oriented philosophy as well as the look and feel of the successful SSRL BluIce graphical user interface for crystallography. These beamline controls feature a minimum number of software layers, the wide use of plug-ins that can be written in any language and unified motion controls that allow on-the-fly scanning and optimization of any beamline component. This paper describes the ways in which BluIce was combined with EPICS and converted into the Java-based JBluIce, discusses the solutions aimed at streamlining and speeding up operations and gives an overview of the tools that are provided by this new open-source control system for facilitating crystallographic experiments, especially in the field of microcrystallography.
The ITER VIS/IR wide angle viewing system: Challenges and on-going R and D
The ITER tokamak is the next generation fusion device which will allow studying burning plasma obtained by a Deuterium-Tritium (D-T) fusion reaction during hundreds of seconds. ITER vacuum vessel real-time protection will be mandatory during plasma operation to avoid water leaks and critical plasma facing components degradation. The protection system will be based on a wide angle viewing system (WAVS) composed with 18 visible (VIS) and 18 infrared (IR) cameras covering 80 % of the vacuum vessel which will be one of the major imaging systems of ITER. Compared to protection systems routinely used on current tokamaks and based on imaging (VIS and/or IR), new constraints must be taken into account because of their influence on the system performance: the harsh environment (high neutron flux) and the metallic plasma facing components (both first wall and divertor). In this new demanding context, we have achieved three mandatory R and D studies starting from the understanding of the source of signals by using realistic photonic simulation up to real-time processing strategy taken into account first order optical design constraints to define what type of performance could be reached for ITER vacuum vessel protection. (authors)
Development of a Low-Cost, Sensitivity-Optimized Fluorescence Sensor for Visible Spectrum Analysis
This paper presents an economically viable, sensitivity-optimized fluorescence sensor for detecting low concentrations of fluorophores in the visible spectrum range. The sensor employs a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Instead of utilizing a general-purposed spectrometer optimized for high spectral resolution, the sensor strikes a balance between resolution and sensitivity by using an appropriate aperture size and optimized optical design tailored for the spectral characteristics of fluorophores. Here, the manuscript demonstrates measurements of ppb-level rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions. Through balanced design that optimizes collection of fluorescence emission without losing spectral information, this work shows the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensors with improved detection sensitivity when compared to bench-top commercial spectrofluorometers at far higher costs.
Scintillators with potential to supersede lanthanum bromide
New scintillators for high-resolution gamma ray spectroscopy have been identified, grown and characterized. Our development efforts have focused on two classes of high light yield materials: Europium-doped alkaline earth halides and Cerium-doped garnets. Of the halide single crystals we have grown by the Bridgman method - SrI{sub 2}, CaI{sub 2}, SrBr{sub 2}, BaI{sub 2} and BaBr{sub 2} - SrI{sub 2} is the most promising. SrI{sub 2}(Eu) emits into the Eu{sup 2+} band, centered at 435 nm, with a decay time of 1.2 {micro}s and a light yield of up to 115,000 photons/MeV. It offers energy resolution better than 3% FWHM at 662 keV, and exhibits excellent light yield proportionality. Transparent ceramics fabrication allows production of Gadolinium- and Terbium-based garnets which are not growable by melt techniques due to phase instabilities. While scintillation light yields of Cerium-doped ceramic garnets are high, light yield non-proportionality and slow decay components appear to limit their prospects for high energy resolution. We are developing an understanding of the mechanisms underlying energy dependent scintillation light yield non-proportionality and how it affects energy resolution. We have also identified aspects of optical design that can be optimized to enhance energy resolution.
New Trends in Microwave Imaging Diagnostics and Application to Burning Plasma
Microwave and millimeter-wave (mm-wave)-based diagnostics have proven invaluable in the understanding of magnetic confinement fusion plasma science and have found wide application at major fusion facilities, including DIII-D, EAST, ASDEX-U, HL-2A, KSTAR, and J-TEXT. This trend is expected to continue unabated in future burning plasma devices such as ITER and DEMO. Attractive features include their nonperturbing nature and relatively modest access requirements due to their short wavelength, as well as recent dramatic advances in the state of the technology. In this tutorial, we describe the basic principles of a number of microwave diagnostics measurements emphasizing imaging, recent technology advances including the so-called “system-on-chip (SoC)” technology, and “synthetic” diagnostics which simulate the response of diagnostics under actual experimental scenarios. In conclusion, the application of microwave diagnostics on reactor plasmas benefits immensely from the development of wide-bandgap electronics and advanced optics designs, both of which ameliorate the effects of the harsh environment.
Sequential, Progressive, Equal-Power Reflective Beam-Splitter Arrays
The equations to calculate equal-power reflectivity of a sequential series of beam splitters is presented. Non-sequential optical design examples are offered for uniform illumination using diode lasers. Objects created using Boolean operators and Swept Surfaces can create objects capable of reflecting light into predefined elevation and azimuth angles. Analysis of the illumination patterns for the array are also presented.
Raman spectroscopy of oxygen carrier particles in harsh environments
Fossil fuel combustion processes generate CO2, a greenhouse gas of considerable concern. To reduce this emission, the National Energy Technology Laboratory (NETL) is evaluating alternative combustion approaches, including chemical looping combustion (CLC). This technique generates relatively pure CO2, suitable for subsequent capture and storage. CLC uses oxygen-carrier particles (OCPs) such as iron oxides, copper oxides, calcium sulfates, etc. to provide oxygen for the combustion process. Optimization of the overall combustion process requires knowledge of the oxidation state (e.g., content of Fe2O3 vs. Fe3O4) of the OCPs during the different stages of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of OCPs in harsh environments is lacking and new sensors need to be developed. We are evaluating non-contact, stand-off Raman spectroscopy to determine the relative concentrations of the oxidized and reduced forms of OCPs at temperatures between 800 °C and 1000 °C, and pressures of about 10 atm. Using cw and pulsed Raman spectroscopy, in combination with a pressurized high-temperature sample chamber, we have optimized the operating parameters such as laser wavelength, laser intensity, collection optic design, focal spot size, etc. and measured Raman spectra of various OCP materials at high temperatures. To extract from the Raman spectra relevant information such as the concentration ratio of a material in different oxidation states, the measured data needs to be processed, and statistical modeling and multivariate calibration need to be performed.
Study and Considerations of Nanometer and Nano-radian Surface Profiler
A Nanometer and Nano-radian Surface Profiler (NSP) is under development at Brookhaven National Laboratory. Nanometer and nano-radian accuracy is required for newest state-of-the-art synchrotron radiation optics and highprecision optical measurement. This test accuracy must be maintained in larger angle test range. In order to reach this accuracy we have to remove all error sources as much as possible or to reduce them to nano-radian level. We present the approaches in optimized optical system designing, scanning optical head mode selection, non-tilted reference method, quality control of optical components, and temperature stabilization. Some considerations and preliminary measurements are presented.
SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: Spatial resolution
An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-Se) avalanche photoconductor called high-gain avalanche rushing amorphous photoconductor (HARP). The charge image created by the scintillator/HARP (SHARP) combination is read out by the electron beams emitted from the FEA. The proposed detector is called scintillator avalanche photoconductor with high resolution emitter readout (SAPHIRE). The programmable avalanche gain of HARP can improve the low dose performance of indirect FPI while the FEA can be made with pixel sizes down to 50 {mu}m. Because of the avalanche gain, a high resolution type of CsI (Tl), which has not been widely used in indirect FPI due to its lower light output, can be used to improve the high spatial frequency performance. The purpose of the present article is to investigate the factors affecting the spatial resolution of SAPHIRE. Since the resolution performance of the SHARP combination has been well studied, the focus of the present work is on the inherent resolution of the FEA readout method. The lateral spread of the electron beam emitted from a 50 {mu}mx50 {mu}m pixel FEA was investigated with two different electron-optical designs: mesh-electrode-only and electrostatic focusing. Our results showed that electrostatic focusing can limit the lateral spread of electron beams to within the pixel size of down to 50 {mu}m. Since electrostatic focusing is essentially independent of signal intensity, it will provide excellent spatial uniformity.
SU-E-I-11: Cascaded Linear System Model for Columnar CsI Flat Panel Imagers with Depth Dependent Gain and Blur
Purpose: To implement a depth dependent gain and blur cascaded linear system model (CLSM) for optimizing columnar structured CsI indirect conversion flat panel imager (FPI) for advanced imaging applications. Methods: For experimental validation, depth dependent escape efficiency, e(z), was extracted from PHS measurement of different CsI scintillators (thickness, substrate and light output). The inherent MTF and DQE of CsI was measured using high resolution CMOS sensor. For CLSM, e(z) and the depth dependent MTF(f,z), were estimated using Monte Carlo simulation (Geant4) of optical photon transport through columnar CsI. Previous work showed that Monte Carlo simulation for CsI was hindered by the non-ideality of its columnar structure. In the present work we allowed variation in columnar width with depth, and assumed diffusive reflective backing and columns. Monte Carlo simulation was performed using an optical point source placed at different depth of the CsI layer, from which MTF(z,f) and e(z) were computed. The resulting e(z) with excellent matching with experimental measurements were then applied to the CLSM, Monte Carlo simulation was repeated until the modeled MTF, DQE(f) also match experimental measurement. Results: For a 150 micron FOS HL type CsI, e(z) varies between 0.56 to 0.45, and the MTF at 14 cycles/mm varies between 62.1% to 3.9%, from the front to the back of the scintillator. The overall MTF and DQE(f) at all frequencies are in excellent agreement with experimental measurements at all frequencies. Conclusion: We have developed a CLSM for columnar CsI scintillators with depth dependent gain and MTF, which were estimated from Monte Carlo simulation with novel optical simulation settings. Preliminary results showed excellent agreement between simulation results and experimental measurements. Future work is aimed at extending this approach to optimize CsI screen optic design and sensor structure for achieving higher DQE(f) in cone-beam CT, which uses high kVp.
OptiMX
OptiMX is a GUI-oriented program with principal aim to be an easy to use, yet comprehensive, interactive accelerator optics design and analysis tool. It was originally developed starting in the 1990s as an MS Windows centric application using the commercial Borland OWL framework. In the spring of 2014, a decision was made to port OptiM to Qt, a modern, portable and open framework. As much as possible, the original interface was preserved.While a significant amount of refactoring was required, the underlying physics has been for the most, left unchanged. The custom plots of the original application have been replaced with functional equivalents based on a stable and well-established library (qwt). With very few minor exceptions the new refactored OptiMX should be a drop-in replacement for the original OWL version.
Modeling the hydrodynamic impact on the tool influence function during hemispherical subaperture optical polishing
To fabricate high-precision and accurate optics relative to the optical design surface, a high level of deterministic control of material removal (i.e., the tool influence function, TIF) during subaperture tool polishing is required. In this study, a detailed analysis of the pressure distribution, which is a key component of the TIF, has been performed using finite element analysis to couple together solid mechanics and fluid dynamics. Modeling experimental parameters of recently published work reveals that, when considering tool deformation, which in turn influences the fluid film thickness between the tool and workpiece, the effective pressure profile has a flat-top distribution. This flat-top pressure profile differs from the parabolic pressure distributions predicted by Hertzian mechanics. Furthermore, the shear contribution is shown here to be a key contributor to material removal, inducing the removal at the periphery of the contact edge and even outside the generally accepted contact area. Finally, the simulated fluid velocities provide evidence of mixed-mode contact polishing, supporting recent experimental findings that also suggest that onset of hydroplaning contributions lead to material removal drop-off.
Light absorption from particulate impurities in snow and ice determined by spectrophotometric analysis of filters
Light absorption by particulate impurities in snow and ice can affect the surface albedo and is important for the climate. The absorption properties of these particles can be determined by collecting and melting snow samples and extracting the particulate material by filtration of the meltwater. This paper describes the optical design and testing of a new instrument to measure the absorption spectrum from 400 to 750 nm wavelength of the particles collected on filters using an ''integrating-sandwich'' configuration. The measured absorption is shown to be unaffected by scattering of light from the deposited particulates. A set of calibration standards is used to derive an upper limit for the concentration of black carbon (BC) in the snow. The wavelength dependence of the absorption spectra from 450 to 600 nm is used to calculate an absorption Angstrom exponent for the aerosol. This exponent is used to estimate the actual BC concentration in the snow samples as well as the relative contributions of BC and non-BC constituents to the absorption of solar radiation integrated over the wavelength band 300 to 750 nm.