Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

A novel Whole Air Sample Profiler (WASP) for the quantification of volatile organic compounds in the boundary layer

The emission and fate of reactive VOCs is of inherent interest to those studying chemical biosphere-atmosphere interactions. In-canopy VOC observations are obtainable using tower-based samplers, but the lack of suitable sampling systems for the full boundary 5 layer has limited the data characterizing the vertical structure of such gases above the canopy height and still in the boundary layer. This is the important region where many reactive VOCs are oxidized or otherwise removed. Here we describe an airborne sampling system designed to collect a vertical profile of air into a 3/800 OD tube 150m in length. The inlet ram air pressure is used to flow sampled air through the 10 tube, which results in a varying flow rate based on aircraft speed and altitude. Since aircraft velocity decreases during ascent, it is necessary to account for the variable flow rate into the tube. This is accomplished using a reference gas that is pulsed into the air stream so that the precise altitude of the collected air can be reconstructed post-collection. The pulsed injections are also used to determine any significant effect 15 from diffusion/mixing within the sampling tube, either during collection or subsequent extraction for gas analysis. This system has been successfully deployed, and we show some measured vertical profiles of isoprene and its oxidation products methacrolein and methyl vinyl ketone from a mixed canopy near Columbia, Missouri.

Mak, J. E.↗

SCILLA nitrogen oxide (NOx) airborne data

Nitrogen oxides mixing ratios in ppb are measured using a Teledyne API Model T200UP. The analyzer uses chemiluminescence to determine NO concentration. Alternating measurement of the concentrations of total NOx (NO + NO2) and just NO are made by directing the sample through a blue light converter that photolyzes NO2 to NO and bypassing it, respectively, with the NO2 concentration calculated as the difference between the two. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, O3, and H2O) and an oxidation flow reactor. The NO, NO2, and NOx mixing ratios were recorded once per minute.

NOx concentration↗

SCILLA ozone (O3) airborne data

Ozone mixing ratios in ppb are measured using a Teledyne API Model T400U. The analyzer uses UV absorption at 254 nm to determine O3 concentration. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between several other gas analyzers (CO, NOx, and H2O) and an oxidation flow reactor. The data were recorded at 0.1 Hz.

Ozone concentration↗

SCILLA Secondary Aerosol Volume Concentration Airborne Data

This data set contains secondary aerosol volume concentration in cubic micrometers per cubic centimeter (um^3/cm^3). The aerosol was generated in an oxidation flow reactor (OFR) and its volume concentration measured with a scanning mobility particle sizer (SMPS). Both components were designed and built at the University of California Riverside. Ambient particles were removed with a Teflon filter upstream of the OFR and then pure ammonium sulfate particles were added to create a stable aerosol surface area on which low-volatility oxidation products condense. High concentrations of hydroxyl radical (OH) formed inside the OFR accelerate the oxidative chemistry that would typically occur over a period of several days in the atmosphere, resulting in the production of secondary aerosol from precursor gases present in the ambient air. Concentrations of added ozone and water vapor were controlled to produce the desired and approximately constant level of photochemical aging. The reactor temperature was controlled, while the pressure was not, and was always slightly lower than that of the sampled outside air. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between the OFR and several gas analyzers (NOx, CO, O3, and H2O). Though not contained in these files, data from an aerosol mass spectrometer intermittently operated downstream of the OFR are also available.

{"secondary aerosol concentration",aerosol_concent↗

Test of 50-kw heat-pipe radiator.

A heat pipe radiator consisting of 100 sodium-filled, 1.91-cm OD, stainless steel heat pipes has been tested at temperatures up to 760 C. This radiator was initially designed to have a heat pipe temperature of 740 C with a central coolant channel temperature of 771 C. The as-fabricated radiator heat pipe temperatures varied from 605 C to 700 C when the central coolant channel average temperature was 740 C. The heat pipes operated at 25 C to 110 C lower-than-expected temperatures, resulting in a 43 kW heat rejection capability vs the 50 kW design goal and the 65 kW ultimate capability of the radiator. The 43 kW heat rejection yields a mass/heat rejection ratio of 0.182 kg/kWt which is good for this early state-of-the-art heat pipe radiator. An end-of-mission life specific weight of 0.154 kg/kW is apparently achievable with improvements in radiator fabrication and brazing techniques.

Kikin, G. M.↗

Development of a self-priming high-capacity heat pipe for flight on OAO-C.

This paper describes the development of a 0.500-inch OD heat pipe with a spiral artery designed to fill under surface tension forces in a one-g field. Capacities in excess of 12,000 watt-inches have been achieved with ammonia as the working fluid. The paper presents the analysis, design, and test of the three-foot-long development models. Also included are some design and fabrication details, along with qualification ground test data for a 12-foot-long spiral artery isothermalizer type heat pipe that is installed on the Orbiting Astronomical Observatory C Model scheduled for launch in 1972.

Edelstein, F.↗

Development of a thermal diode heat pipe for the advanced thermal control flight experiment /ATFE/.

Description of the analysis, design, fabrication, and test of the engineering model of the ATFE diode. Included is a review of several diode concepts that led to selection of the liquid blockage technique for shut-off. The diode is made of stainless steel, 26 in. long, 0.375-in. nominal OD, with self-filling spiral artery wick and ammonia working fluid. In the normal heat pipe mode, at ambient temperatures, the diode capacity is 85 W. For flight, the pipe will deliver 20 W with a 9 F temperature difference between the external evaporator and condenser surfaces. Reverse mode conduction is less than 1.5 W with a 260 F temperature difference.

Swerdling, B.↗

Design of an external-fueled thermionic diode for in-pile testing.

Description of an external-fueled thermionic diode suitable for in-pile testing in a research reactor. The active electrode area is 94 sq cm. The 10-in. long, 1.5-in.-OD emitter body is tungsten 2% thoria. The fuel is contained in six 0.4-in.-diam holes equally spaced about the 0.5-in. central emitter hole. The collector is niobium-1% zirconium. The expected diode performance is 6 W/sq cm at 2000 K. In addition to following the constraints imposed by the in-pile testing and the electrically heated performance mapping prior to insertion in-pile, the diode will have end configurations prototypical of those anticipated for a flow-through, NaK-cooled, external-fuel thermionic reactor.

Ernst, D. M.↗

Design and testing a high fuel volume fraction, externally finned, thermionic emitter.

A prototypical, high fuel volume fraction, thermionic emitter body was designed and tested. The emitter body is all tungsten, with a 1.40-cm ID, a 3.23-cm OD, and eight full-length axial fins. The emitter thickness is 0.15 cm while the fins and outer clad are 0.075 cm thick. Different methods of fabrication were used in making the test samples. Stress analysis was performed with a three-dimensional elastic code. Thermal testing of the samples, duplicating calculated radial temperature gradients, heatup and cooldown rates, and emitter body temperatures in operation, was performed with no structural failures noted (six heatup and cooldown cycles per sample). Further emitter analysis and testing is planned.

Peelgren, M. L.↗

DONAR - A computer processing system to extend ultrasonic pulse-echo testing.

A dedicated general purpose digital computer has been built on the principle of a sampled-data system to run an ultrasonic subsystem under programmed control. A most significant application is the ability to extract a signal from an interfering background. As illustrated in the paper, a 1 mm diameter transducer was used to measure the diameter of a 2.5 mm OD plastics tube with 0.4 mm wall thickness. Echoes from all four surfaces were displayed and the measurements indicated an uncertainty of less than 0.1 mm.

Lees, S.↗

Satellite orbit determination

A historic account of the activities of the Satellite OD Group during the MM'71 mission is given along with an assessment of the accuracy of the determined orbit of the Mariner 9 spacecraft. Preflight study results are reviewed, and the major error sources described. Tracking and data fitting strategy actually used in the real time operations is itemized, and Deep Space Network data available for orbit fitting during the mission and the auxiliary information used by the navigation team are described. A detailed orbit fitting history of the first four revolutions of the satellite orbit of Mariner 9 is presented, with emphasis on the convergence problems and the delivered solution for the first orbit trim maneuver. Also included are a solution accuracy summary, the history of the spacecraft orbit osculating elements, the results of verifying the radio solutions with TV imaging data, and a summary of the normal points generated for the relativity experiment.

Jordan, J. F.↗

Experimental evaluation of stresses in cylindrically hollow (drilled) balls

An experimental stress analysis was undertaken to evaluate stresses within cylindrically hollow (drilled) bearing balls proportioned for 40, 50, and 60 percent mass reductions. Strain gage rosettes were used to determine principal strains and stresses in the steel ball models statically loaded in various orientations. Results are reported for 127 mm OD balls under 44,500 N loads. Similitude considerations permit these results to be applied to calculate stresses in actual size drilled bearing balls proportioned to these mass reductions.

Nypan, L. J.↗

Deformation and annealing study of Nicraly

Extensive experiments were carried out on the ODS alloy Nicraly, (an alloy prepared by mechanical alloying and consolidating a powder blend consisting of 16% chromium, 4% aluminum, 2-3% yttria, balance nickel), in efforts to develop methods of controlling the grain size and grain shape of the material. The experiments fell into two general categories: variations in the annealing parameters using the as-extruded material as it was received, and various thermomechanical processing schedules (various combinations of cold work and annealing). Success was achieved in gaining grain size and grain shape control by annealing of the as-extruded material. By proper selection of annealing temperature and cooling rates, the grain size of the as-received material was increased almost two orders of magnitude (from an average grain dimension of 0.023 mm to 1.668 mm) while the aspect ratio was increased by some 50% (from 20:1 to 30:1). No success was achieved in gaining significant control of the grain size and shape of the material by thermo-mechanical processing.

Trela, D. M.↗

Cryogenic heat pipe experiment - Flight performance onboard a sounding rocket

Flight data from a 15.8 mm OD, 760 mm long, axial-groove, methane cryogenic heat pipe verified successful priming and operation during six min of zero-g time. The nominal power applied to the evaporator was 60-w for the first 60 sec of zero-g time, 14 w for the next 270 sec, and 25 w for the last 20 sec of flight. The heat pipe condenser was mounted into an aluminum heat sink which was cooled to 103 K at launch and increased in temperature to 128 K by the end of the flight. Ground test data obtained for the flight heat pipe, together with theoretical predictions, indicate a zero-g heat transport capability of 3500 to 4000 w-cm in the 100-125 K temperature range.

Harwell, W.↗

Development of a thermal diode heat pipe for cryogenic applications

The paper describes the development of a cryogenic thermal diode heat pipe for space flight applications. The diode has ethane working fluid, and uses the liquid blockage technique with an internal blocking orifice, to accomplish shutoff in the reverse mode. The pipe is 0.635 cm OD by 75.82 cm long including a 2.54 cc excess liquid reservoir. Experimental data are presented for forward mode throughput vs tilt, film coefficients, and reverse mode characteristics. Transport capacity is 1000 w-cm at 2.5 cm tilt. Evaporator and condenser film coefficients were 0.92 and 1.64 w/sq cm K, respectively.

Quadrini, J. A.↗

Cost/benefit analysis of advanced material technologies for small aircraft turbine engines

Cost/benefit studies were conducted on ten advanced material technologies applicable to small aircraft gas turbine engines to be produced in the 1985 time frame. The cost/benefit studies were applied to a two engine, business-type jet aircraft in the 6800- to 9100-Kg (15,000- to 20,000-lb) gross weight class. The new material technologies are intended to provide improvements in the areas of high-pressure turbine rotor components, high-pressure turbine rotor components, high-pressure turbine stator airfoils, and static structural components. The cost/benefit of each technology is presented in terms of relative value, which is defined as a change in life cycle cost times probability of success divided by development cost. Technologies showing the most promising cost/benefits based on relative value are uncooled single crystal MAR-M 247 turbine blades, cooled DS MAR-M 247 turbine blades, and cooled ODS 'M'CrAl laminate turbine stator vanes.

Comey, D. H.↗

A re-entrant groove hydrogen heat pipe

This paper extends the development of reentrant groove technology to hydrogen heat pipes. Parametric analyses are presented which optimize the theoretical design while considering the limitations of state-of-the-art extrusion technology. Acceptable production-type runs of extruded lengths (over 300 m) could only be achieved at the expense of a wider nominal groove opening than specified (0.33 mm vs. 0.20 mm). However, dimensional variations of other critical dimensions were within 0.05 mm, which exceeded expectations. The 6063-T6 aluminum extrusion is 14.6 mm OD with a wall thickness of 1.66 mm and contains 20 axial grooves which surround a central 9.3-mm-diam vapor core. Each axial groove is 0.775-mm-diam with a 0.33 mm opening. An excess vapor reservoir is provided at the evaporator to minimize the pressure containment hazard during ambient storage. Details of the instrumentation and helium-cooled test installation are also presented.

Alario, J.↗

Design, fabrication and test of a hydrogen heat pipe

Re-entrant groove technology was extended to hydrogen heat pipes. Parametric analyses are presented which optimize the theoretical design while considering the limitations of state-of-the-art extrusion technology. The 6063-T6 aluminum extrusion is 14.6 mm OD with a wall thickness of 1.66 mm and contains 20 axial grooves which surround a central 9.3 mm diameter vapor core. Each axial groove is 0.775 mm diameter with a 0.33 mm opening. An excess vapor reservoir is provided at the evaporator to minimize the pressure containment hazard during ambient storage. Modifications to the basic re-entrant groove profile resulted in improved overall performance. While the maximum heat transport capacity decreased slightly to 103 w-m the static wicking height increased markedly to 4.5 cm. The heat pipe became operational between 20 and 30 K after a cooldown from 77 K without any difficulty. Steady state performance data taken over a 19 to 23 K temperature range indicated: (1) maximum heat transport capacity of 5.4 w-m; (2) static wicking height of 1.42 cm; and (3) overall heat pipe conductance of 1.7 watts/deg C.

Alario, J.↗