Low Level Radioactive Xenon Monitoring by Phoswich Detector System
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Squeeze a material hard enough, and its structure and properties will change, sometimes dramatically so. With enough heat and pressure, scientists can turn pencil lead (graphite), one of Earth’s softest materials, into diamond, one of its hardest. Apply even more pressure—such as might be found in explosions, detonating nuclear weapons, laser fusion experiments, meteorite impacts, or the hearts of stars and planets—and materials can take stranger forms. Deep in Jupiter’s core, for instance, where pressures likely reach 50 to 100 million times that of Earth’s atmosphere, hydrogen is predicted to be a metallic liquid rather than the familiar transparent gas.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
The purpose of this research was to produce a measurable quantity of radioactive argon-37 through photonuclear production methods. The detection of argon-37, above background levels, uniquely and clearly indicates the underground detonation of a nuclear device.
Explore the source record for details and available documents.
A handheld system developed to digitize a contextual understanding of the scene at a chemical, biological, radiological, nuclear and/or explosives (CBRNE) events is described. The system uses LiDAR and cameras to create a colorized 3D model of the environment, which helps domain experts that are supporting responders in the field. To generate the digitized model, a responder scans any suspicious objects and the surroundings by carrying the system through the scene. The scanning system provides a real-time user interface to inform the user about scanning progress and to indicate any areas that may have been missed either by the LiDAR sensors or the cameras. Currently, the collected data are post-processed on a different device, building a colorized triangular mesh of the encountered scene, with the intention of moving this pipeline to the scanner at a later point. The mesh is sufficiently compressed to be sent over a reduced bandwidth connection to a remote analyst. Furthermore, the system tracks fiducial markers attached to diagnostic equipment that is placed around the suspicious object. The resulting tracking information can be transmitted to remote analysts to further facilitate their supporting efforts. The paper will discuss the system's design, software components, the user interface used for scanning a scene, the necessary procedures for calibration of the sensors, and the processing steps of the resulting data. The discussion will close by evaluating the system's performance on 11 scenes.
The Underground Test Area (UGTA) activity is responsible for assessing and evaluating the effects of the underground nuclear weapons tests on groundwater at the Nevada National Security Site (NNSS), formerly the Nevada Test Site (NTS), and implementing a corrective action closure strategy. The UGTA strategy is based on a combination of characterization, modeling studies, monitoring, and institutional controls (i.e., monitored natural attenuation). The closure strategy verifies through appropriate monitoring activities that contaminants of concern do not exceed the SDWA at the regulatory boundary and that adequate institutional controls are established and administered to ensure protection of the public. Other programs conducted at the NNSS supporting the environmental mission include the Routine Radiological Environmental Monitoring Program (RREMP), Waste Management, and the Infrastructure Program. Given the current programmatic and operational demands for various water-monitoring activities at the same locations, and the ever-increasing resource challenges, cooperative and collaborative approaches to conducting the work are necessary. For this reason, an integrated sampling plan is being developed by the UGTA activity to define sampling and analysis objectives, reduce duplication, eliminate unnecessary activities, and minimize costs. The sampling plan will ensure the right data sets are developed to support closure and efficient transition to long-term monitoring. The plan will include an integrated reporting mechanism for communicating results and integrating process improvements within the UGTA activity as well as between other U.S. Department of Energy (DOE) Programs. (authors)
Low-level tritium was unexpectedly detected in 2010 in a monitoring well located more than three kilometers (km) down-gradient of an area formerly used for underground nuclear testing. The approach used by the U.S. Department of Energy (DOE) to investigate potential sources for the tritium is an exemplary case study of corrective action investigation at the Nevada National Security Site (NNSS). Multiple challenges presented themselves during the course of the investigation, ranging from difficulties associated with confirming the presence tritium within the well to a field site characterized by remote, rugged terrain, high elevation, inclement weather, great depths to groundwater, complex geology, and residual surficial contamination originating from the near-surface detonations of two large-scale nuclear plowshare tests. Limited resources required a judicious process for evaluating competing conceptual models. Timely communication of monitoring results to stakeholders and early involvement of regulatory authorities in the planning process were critical components of the overall investigation. (authors)
Three applications were completed using the Advanced Simulation Capability for Environmental Management (ASCEM), supported by the U.S. Department of Energy's Office of Environmental Management. These analyses were performed for the Savannah River Site (SRS) F-Area, the Los Alamos National Laboratory (LANL) Site, and the Nevada National Security Site (NNSS). At the SRS F-Area, ASCEM simulations were used to help develop cost-effective, long-term monitoring approaches for science-based site closure and management. The simulation results were used to develop a mechanistic understanding of correlations between contaminant concentrations and master variables that can be used for monitoring. At LANL, the ASCEM simulator Amanzi was integrated with a LANL-based decision support tool for the LANL onsite program. A saturated-zone site model focused on a key area of interest was developed and calibrated to measured data. This model was applied to quantify uncertainty and provide decision support to inform chromium remediation efforts. To support assessment of groundwater contamination at NNSS, ASCEM was used to calibrate hydrologic properties and flow directions using water levels observed under steady-state conditions and during four different pump tests on Pahute Mesa. The flow fields generated from these pump tests will be used to simulate transport pathways from underground nuclear tests to compare with field observations and to test alternative conceptual models of transport, which will ultimately facilitate better placement of monitoring wells. (authors)
Rainier Mesa (RM) is a tuffaceous, high-elevation plateau on the Nevada Test Site (NTS) that has been subjected to numerous nuclear tests between 1957 and 1992. Unlike other tests on the NTS located within or just above the saturated zone, tests at the RM T-tunnel complex were conducted within a variably saturated sequence of bedded and non-welded vitric and zeolitized tuff units, located approximately 500 m above the regional groundwater flow system. The low permeability and high porosity of the underlying zeolitized tuff units suggest the downward transport of radionuclides released from these tests are minimal through the tuff matrix. However, numerous faults observed to discharge water into tunnel drifts may serve as preferential pathways for radionuclide migration. Data collected from tunnel drifts indicate that faulting within the zeolitized tuff units is sparse with fractal clustering, and that connectivity between adjacent fault clusters is often weak to non-existent. The sparse fault density at RM, in conjunction with the extreme variability in the spatial distribution of faults, poses challenges not readily addressed by existing upscaling methods that upscale fracture properties as equivalent grid tensors. The unique fault statistics at RM has led to the development of a fracture continuum method designed to faithfully preserve flow and transport properties of the sparse fault networks. This method is based on selective mapping and upscaling of fault hydraulic and transport properties onto a continuum grid in support of dual-permeability simulations. Comparisons of global flow and random walk particle breakthrough between two-dimensional discrete fracture network and fracture continuum simulations demonstrate the utility of this method.
With the continued population of the International Monitoring System (IMS) network and the certification of radioxenon laboratory systems it has become necessary to calibrate and test these systems using as many of the radioxenon isotopes as possible. Several very promising techniques have been explored recently that allow for convenient production of Xe-133, Xe-131m, the short-lived isotope Xe-135, and even the difficult to obtain Xe-133m. IMS national and international laboratories have traditionally obtained Xe-133 from medical isotope suppliers. The activity of these medical dose samples is extremely high (~ 740 MBq) and requires very careful fume hood work to dilute down to appropriate levels (~ 10 Bq). By waiting for 10 or more half-lives it is possible to reduce the handling regimen considerably, while also obtaining a strong Xe-131m signature due to its longer half-life (11.9 days). The short-lived isotope Xe-135 (9.14 hrs) and the longer lived parent nuclide Xe-133m (2.2 day half-life) are never present in these samples. To obtain these isotopes another source or technique is required. This paper will discuss the two techniques developed and implemented at Pacific Northwest National Lab (PNNL) and show the results obtained from each technique. The first is an in-house method that allows for on demand production of two of these isotopes, Xe-133 and Xe-135, using HEU and a modest flux neutron source. The second method uses a research reactor at the Pullman campus of Washington State University to produce Xe-133, Xe-133m and Xe-135.
Two classical verification problems from shock hydrodynamics are adapted for verification in the context of ideal magnetohydrodynamics (MHD) by introducing strong transverse magnetic fields, and simulated using the finite element Lagrange-remap MHD code ALEGRA for purposes of rigorous code verification. The concern in these verification tests is that inconsistencies related to energy advection are inherent in Lagrange-remap formulations for MHD, such that conservation of the kinetic and magnetic components of the energy may not be maintained. Hence, total energy conservation may also not be maintained. MHD shock propagation may therefore not be treated consistently in Lagrange-remap schemes, as errors in energy conservation are known to result in unphysical shock wave speeds and post-shock states. That kinetic energy is not conserved in Lagrange-remap schemes is well known, and the correction of DeBar has been shown to eliminate the resulting errors. Here, the consequences of the failure to conserve magnetic energy are revealed using order verification in the two magnetized shock-hydrodynamics problems. Further, a magnetic analog to the DeBar correction is proposed and its accuracy evaluated using this verification testbed. Results indicate that only when the total energy is conserved, by implementing both the kinetic and magnetic components of the DeBar correction, can simulations in Lagrange-remap formulation capture MHD shock propagation accurately. Additional insight is provided by the verification results, regarding the implementation of the DeBar correction and the advection scheme.
Pacific Northwest National Laboratory (PNNL) is a key part in the international community in the detection of radioxenon. PNNL’s design of radioxenon detection systems have resulted in the need for multiple sources to be capable of producing high quality NaI and CsI well detectors. Testing of NaI and CsI detectors from multiple manufactures has resulted in the discovery of two issues. First, there is potential for a dead layer, due to the manufacturer handling of the crystal, to be present on both the CsI and NaI crystals. The second issue is an energy drift caused by incorrect mating of PMT and PMT base to the crystal. These two issues cause adverse effects on the measurement of radioxenon or any other radiological measurement. It is clear that additional handling and inspection procedures are necessary during the manufacturing process. This paper will discuss the matter in more detail and give evidence of the presence of these issues in PNNL purchased crystals. The paper will also propose procedures for handling and testing to high quality CsI and NaI crystals get delivered on future purchases.