Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Study of acoustic emission during mechanical tests of large flight weight tank structure

A PPO-insulated, flight-weight, subscale, aluminum tank was monitored for acoustic emissions during a proof test and during 100 cycles of environmental test simulating space flights. The use of a combination of frequency filtering and appropriate spatial filtering to reduce background noise was found to be sufficient to detect acoustic emission signals of relatively small intensity expected from subcritical crack growth in the structure. Several emission source locations were identified, including the one where a flaw was detected by post-test x-ray inspections. For most source locations, however, post-test inspections did not detect flaws; this was partially attributed to the higher sensitivity of the acoustic emission technique than any other currently available NDT method for detecting flaws. For these non-verifiable emission sources, a problem still remains in correctly interpreting observed emission signals.

Mccauley, B. O.↗

Caution and warning system

Battery-operated, biomedical-monitoring and display network is used for intensive-care and patient monitoring. Digital, bus-oriented design enhances simplicity, flexibility, and noise immunity advantages. Network is 100 percent reprogramable. Malfunctions are immediately displayed, accompanied by proper corrective procedures.

Mcclung, T. M.↗

A precision star tracker utilizing advanced techniques and materials

An image dissector star tracker has been developed which operates in the photon counting mode making it possible to utilize all digital electronics. A unique pulse processing circuit allows bright stars to be tracked as well as dim stars. Thermal mechanical stability has been greatly enhanced by fabricating a housing with graphite/epoxy composite material with a linear coefficient of thermal expansion near zero. Test results indicate the +10 Mv stars can be acquired and tracked, while position variation with star intensity is less than 2 arc seconds from 2.5 Mv to +10 Mv. The noise equivalent angle for a +8 Mv star is 3 arc seconds. Polynominal correction for remaining cross-coupling and nonlinearity reduced error over total 1 x 1 deg field to 1.5 arc seconds.

Gates, R. F.↗

Particle and field characteristics of the high-latitude plasma sheet boundary layer

Particle and field data obtained by eight ISEE spacecraft experiments are used to define more precisely the characteristics of the high-latitude boundary region of the plasma sheet. A region immediately adjacent to the high-latitude plasma sheet boundary has particle and field characteristics distinctly different from those observed in the lobe and deeper in the central plasma sheet. Electrons over a broad energy interval are 'field-aligned' and bidirectional, whereas in the plasma sheet the distributions are more isotropic. The region supports intense ion flows, large-amplitude electric fields, and enhanced broad-band electrostatic noise.

Parks, G. K.↗

First plasma wave observations of Uranus

Plasma wave data collected by instrumentation on Voyager 2 as it passed Uranus magnetosphere are discussed. Radio signals at 31.1 and 56.2 kHz were detected 5 days from closest approach and were buried in a burst of electrostatic noise as the spacecraft crossed the bow shock 10 hr before closest approach. The noise arose from electrons escaping the bow shock into the solar wind. Electric field intensities downstream of the shock were reduced, a situation similar to those observed around Saturn and Jupiter. Whistler-mode hiss and chorus emissions were prominent within the magnetosphere at less than 8 Uranus radii, a region where particle detectors registered intense energetic electron fluxes. Also, micron-sized particle impacts at a rate of 30-50 impacts/sec occurred when passing through the ring plane. The duration of the micro-impact phase was sufficient to estimate the ring thickness as about 4000 km.

Gurnett, D. A.↗

The lobe to plasma sheet boundary layer transition - Theory and observations

The lobe and the plasma sheet boundary layer in the earth's magnetotail are regions of different plasma conditions and share a common interface. The transition from the lobe to the plasma sheet boundary layer is examined here using AMPTE/IRM data. When the satellite crossed from the lobe to the plasma sheet boundary layer, intense narrow-banded wave bursts at 1 kHz were observed and broadband electrostatic noise (BEN) immediately followed. Simultaneous with the onset of BEN, high energy earthward streaming proton beams at more than 40 keV (more than 2700 km/s) were detected. These results are used as input into a numerical simulation to study ion beam instabilities in the PSBL.

Schriver, D.↗

A comparative analysis of XV-15 tiltrotor hover test data and WOPWOP predictions incorporating the fountain effect

Acoustic measurements from a hovering full scale XV-15 tilt rotor with the advanced technology blades are presented which show the directionality of fountain effect noise. Predicted acoustic directivity results are also presented which show agreement with the measured data. The aeroacoustic code, WOPWOP, was used in conjunction with a mathematical model which simulated the fountain recirculation aerodynamic effect on the rotor blade surface pressures. The predictions were used to identify the spike character in the measured data as fountain effect associated noise. The directivity of the fountain effect noise was observed to be dominant at the rear of the aircraft with increased intensities 45 degrees below the rotor disk planes.

Rutledge, Charles K.↗

A comparative analysis of XV-15 tiltrotor hover test data and WOPWOP predictions incorporating the fountain effect

Acoustic measurements from a hovering full-scale XV-15 tiltrotor with the advanced technology blades are presented which show the directionality of fountain effect noise. Predicted activity directivity results are also presented which show agreement with the measured data. The aeroacoustic code, WOPWOP, was used in conjunction with a mathematical model which simulated the fountain/recirculation aerodynamic effect on the rotors' blade surface pressures. The predictions were used to identify the spike character in the measured data as fountain effect associated noise. The directivity of the fountain effect noise was observed to be dominant at the rear of the aircraft with increased intensities 45 degrees below the rotor disk planes.

Rutledge, Charles K.↗

EMPIRICAL DETERMINATION OF EINSTEIN A-COEFFICIENT RATIOS OF BRIGHT [Fe II] LINES

The Einstein spontaneous rates (A-coefficients) of Fe{sup +} lines have been computed by several authors with results that differ from each other by up to 40%. Consequently, models for line emissivities suffer from uncertainties that in turn affect the determination of the physical conditions at the base of line excitation. We provide an empirical determination of the A-coefficient ratios of bright [Fe II] lines that would represent both a valid benchmark for theoretical computations and a reference for the physical interpretation of the observed lines. With the ESO-Very Large Telescope X-shooter instrument between 3000 Å and 24700 Å, we obtained a spectrum of the bright Herbig-Haro object HH 1. We detect around 100 [Fe II] lines, some of which with a signal-to-noise ratios ≥100. Among these latter lines, we selected those emitted by the same level, whose dereddened intensity ratios are direct functions of the Einstein A-coefficient ratios. From the same X-shooter spectrum, we got an accurate estimate of the extinction toward HH 1 through intensity ratios of atomic species, H I recombination lines and H{sub 2} ro-vibrational transitions. We provide seven reliable A-coefficient ratios between bright [Fe II] lines, which are compared with the literature determinations. In particular, the A-coefficient ratios involving the brightest near-infrared lines (λ12570/λ16440 and λ13209/λ16440) are in better agreement with the predictions by the Quinet et al. relativistic Hartree-Fock model. However, none of the theoretical models predict A-coefficient ratios in agreement with all of our determinations. We also show that literature data of near-infrared intensity ratios better agree with our determinations than with theoretical expectations.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase-noise induced limitations on cooling and coherent evolution in optomechanical systems

We present a detailed theoretical discussion of the effects of ubiquitous laser noise on cooling and the coherent dynamics in optomechanical systems. Phase fluctuations of the driving laser induce modulations of the linearized optomechanical coupling as well as a fluctuating force on the mirror due to variations of the mean cavity intensity. We first evaluate the influence of both effects on cavity cooling and find that for a small laser linewidth, the dominant heating mechanism arises from intensity fluctuations. The resulting limit on the final occupation number scales linearly with the cavity intensity both under weak- and strong-coupling conditions. For the strong-coupling regime, we also determine the effect of phase noise on the coherent transfer of single excitations between the cavity and the mechanical resonator and obtain a similar conclusion. Our results show that conditions for optical ground-state cooling and coherent operations are experimentally feasible and thus laser phase noise does pose a challenge but not a stringent limitation for optomechanical systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-A-18C-10: Dynamic Intensity Weighted Region of Interest Imaging

Purpose: For image guidance tasks full image quality is not required throughout the entire image. With dynamic filtration of the kV imaging beam the noise properties of the CT image can be locally controlled, providing a high quality image around the target volume with a lower quality surrounding region while providing substantial dose sparing to the patient as well as reduced scatter fluence on the detector. Methods: A dynamic collimation device with 3mm copper blades has been designed to mount in place of the bowtie filter on the On-Board Imager (Varian Medical Systems). The beam intensity is reduced by 95% behind the copper filters and the aperture is controlled dynamically to conformally illuminate a given ROI during a standard cone-beam CT scan. A data correction framework to account for the physical effects of the collimator prior to reconstruction was developed. Furthermore, to determine the dose savings and scatter reduction a monte carlo model was built in BEAMnrc with specifics from the Varian Monte Carlo Data Package. The MC model was validated with Gafchromic film. Results: The reconstructed image shows image quality comparable to a standard scan in the specified ROI, with higher noise and streaks in the outer region but still sufficient information for alignment to high contrast structures. The monte carlo modeling showed that the scatter-to-primary ratio was reduced from 1.26 for an unfiltered scan to 0.45 for an intensity weighted scan, suggesting that image quality may be improved in the inner ROI. Dose in the inner region was reduced 10–15% due to reduced scatter and by as much as 75% in the outer region. Conclusion: Dynamic intensity-weighted ROI imaging allows reduction of imaging dose to sensitive organs away from the target region while providing images that retain their utility for patient setup and procedure guidance. Funding was provided in part by Varian Medical Systems and NIH Grants 1RO1CA120540, T32EB002103, S10 RR021039 and P30 CA14599. The contents of this work are solely the responsibility of the authors and do not necessarily represent the official views of any of the supporting organizations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical communication noise rejection using corelated photons

This paper describes a completely new way to perform noise rejection using photons correlated through quantum entanglement to improve an optical communications link in the presence of uncorrelated noise. In particular, a detailed analysis is made of the case where a classical link would be saturated by an intense background, such as when a satellite is in front of the sun, and identifies where the quantum correlating system has superior performance.

signal to noise enhancement↗

The methods of paired comparisons and magnitude estimation in judging the noisiness of aircraft

The point of subjective equality in regard to perceived noisiness for each of 14 pairs of aircraft noises was obtained using both magnitude estimation technique and the method of paired comparisons. Both methods gave approximately the same estimates of the points of subjective equality for the noise pairs, and both showed similar correspondence to predictive physical measures. Nevertheless, the two methods appear to have greater face validity to the listeners. However, the magnitude estimation technique appears to be more efficient; for a given level of reliability it requires approximately 50% of the testing time required by the paired comparison method. The functions relating physical intensity to the estimated magnitude of subjective noisiness had slopes ranging from about .61 to .29 for the aircraft noises employed in this study, indicating a required change of about 5 to 10 db for a doubling in subjective magnitude. Some physical units of noise measurement were found to be very predictive (standard errors of estimate as low as 1.9 db) of the subjective judgements of noisiness.

Clarke, F. R.↗

A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors

Purpose: One of the benefits of photon counting (PC) detectors over energy integrating (EI) detectors is the absence of many additive noise sources, such as electronic noise and secondary quantum noise. The purpose of this work is to demonstrate that thresholding voltage gains to detect individual x rays actually generates an unexpected source of white noise in photon counters. Methods: To distinguish the two detector types, their point spread function (PSF) is interpreted differently. The PSF of the energy integrating detector is treated as a weighting function for counting x rays, while the PSF of the photon counting detector is interpreted as a probability. Although this model ignores some subtleties of real imaging systems, such as scatter and the energy-dependent amplification of secondary quanta in indirect-converting detectors, it is useful for demonstrating fundamental differences between the two detector types. From first principles, the optical transfer function (OTF) is calculated as the continuous Fourier transform of the PSF, the noise power spectra (NPS) is determined by the discrete space Fourier transform (DSFT) of the autocovariance of signal intensity, and the detective quantum efficiency (DQE) is found from combined knowledge of the OTF and NPS. To illustrate the calculation of the transfer functions, the PSF is modeled as the convolution of a Gaussian with the product of rect functions. The Gaussian reflects the blurring of the x-ray converter, while the rect functions model the sampling of the detector. Results: The transfer functions are first calculated assuming outside noise sources such as electronic noise and secondary quantum noise are negligible. It is demonstrated that while OTF is the same for two detector types possessing an equivalent PSF, a frequency-independent (i.e., ''white'') difference in their NPS exists such that NPS{sub PC}{>=}NPS{sub EI} and hence DQE{sub PC}{<=}DQE{sub EI}. The necessary and sufficient condition for equality is that the PSF is a binary function given as zero or unity everywhere. In analyzing the model detector with Gaussian blurring, the difference in NPS and DQE between the two detector types is found to increase with the blurring of the x-ray converter. Ultimately, the expression for the additive white noise of the photon counter is compared against the expression for electronic noise and secondary quantum noise in an energy integrator. Thus, a method is provided to determine the average secondary quanta that the energy integrator must produce for each x ray to have superior DQE to a photon counter with the same PSF. Conclusions: This article develops analytical models of OTF, NPS, and DQE for energy integrating and photon counting digital x-ray detectors. While many subtleties of real imaging systems have not been modeled, this work is illustrative in demonstrating an additive source of white noise in photon counting detectors which has not yet been described in the literature. One benefit of this analysis is a framework for determining the average secondary quanta that an energy integrating detector must produce for each x ray to have superior DQE to competing photon counting technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Whistler mode noise in Jupiter's inner magnetosphere

A study is made of the amplitude and spectral extent of whistler mode noise in the inner magnetosphere of Jupiter. It is found that the 'hat-shaped' pitch angle distributions of energetic electrons (21 and 31 MeV at L=3) are consistent with those predicted in the presence of a band-limited spectrum of whistler mode noise. The equatorial maximum linear growth rate of parallel propagating whistlers are consistent with those necessary to limit the energetic electron intensities by the whistler mode instability. It is noted that the wave phase speeds before wave reflection can occur at high latitudes and that wave growth is limited to a disk-like region centered around the magnetic equator. The frequency extent of the whistler mode noise spectrum may be estimated by the range of frequencies maximally unstable to equatorial linear growth. A value is found for the spectral density of the broadband whistler mode noise necessary to balance radial diffusion of energetic electrons above the critical range, and an expression is derived for the energetic electron system response to fluctuations about the limiting flux value.

Sentman, D. D.↗

Fluctuation localization imaging-based fluorescence in situ hybridization (fliFISH) for accurate detection and counting of RNA copies in single cells

Here, quantitative gene expression analysis in intact single cells can be achieved using single molecule-based fluorescence in situ hybridization (smFISH). This approach relies on fluorescence intensity to distinguish between true signals, emitted from an RNA copy hybridized with multiple oligonucleotide probes, and background noise. Thus, the precision in smFISH is often compromised by partial or nonspecific probe binding and tissue autofluorescence, especially when only a small number of probes can be fitted to the target transcript. Here we provide an accurate approach for setting quantitative thresholds between true and false signals, which relies on on-off duty cycles of photoswitchable dyes. This fluctuation localization imaging-based FISH (fliFISH) uses on-time fractions (measured over a series of exposures) collected from transcripts bound to as low as 8 probes, which are distinct from on-time fractions collected from nonspecifically bound probes or autofluorescence. Using multicolor fliFISH, we identified radial gene expression patterns in mouse pancreatic islets for insulin, the transcription factor, NKX2-2 and their ratio ( Nkx2 - 2/Ins2 ). These radial patterns, showing higher values in β cells at the islet core and lower values in peripheral cells, were lost in diabetic mouse islets. In summary, fliFISH provides an accurate, quantitative approach for detecting and counting true RNA copies and rejecting false signals by their distinct on-time fractions, laying the foundation for reliable single-cell transcriptomics.

59 BASIC BIOLOGICAL SCIENCES↗

The upgrade of the Thomson scattering system for measurement on the C-2/C-2U devices

The C-2/C-2U Thomson scattering system has been substantially upgraded during the latter phase of C-2/C-2U program. A Rayleigh channel has been added to each of the three polychromators of the C-2/C-2U Thomson scattering system. Onsite spectral calibration has been applied to avoid the issue of different channel responses at different spots on the photomultiplier tube surface. With the added Rayleigh channel, the absolute intensity response of the system is calibrated with Rayleigh scattering in argon gas from 0.1 to 4 Torr, where the Rayleigh scattering signal is comparable to the Thomson scattering signal at electron densities from 1 × 10{sup 13} to 4 × 10{sup 14} cm{sup −3}. A new signal processing algorithm, using a maximum likelihood method and including detailed analysis of different noise contributions within the system, has been developed to obtain electron temperature and density profiles. The system setup, spectral and intensity calibration procedure and its outcome, data analysis, and the results of electron temperature/density profile measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluence field optimization for noise and dose objectives in CT

Purpose: Selecting the appropriate imaging technique in computed tomography (CT) inherently involves balancing the tradeoff between image quality and imaging dose. Modulation of the x-ray fluence field, laterally across the beam, and independently for each projection, may potentially meet user-prescribed, regional image quality objectives, while reducing radiation to the patient. The proposed approach, called fluence field modulated CT (FFMCT), parallels the approach commonly used in intensity-modulated radiation therapy (IMRT), except ''image quality plans'' replace the ''dose plans'' of IMRT. This work studies the potential noise and dose benefits of FFMCT via objective driven optimization of fluence fields. Methods: Experiments were carried out in simulation. Image quality plans were defined by specifying signal-to-noise ratio (SNR) criteria for regions of interest (ROIs) in simulated cylindrical and oblong water phantoms, and an anthropomorphic phantom with bone, air, and water equivalent regions. X-ray fluence field patterns were generated using a simulated annealing optimization method that attempts to achieve the spatially-dependent prescribed SNR criteria in the phantoms while limiting dose (to the volume or subvolumes). The resulting SNR and dose distributions were analyzed and compared to results using a bowtie filtered fluence field. Results: Compared to using a fixed bowtie filtered fluence, FFMCT achieved superior agreement with the target image quality objectives, and resulted in integral dose reductions ranging from 39 to 52%. Prioritizing dose constraints for specific regions of interest resulted in a preferential reduction of dose to those regions with some tradeoff in SNR, particularly where the target low dose regions overlapped with regions where high SNR was prescribed. The method appeared fairly robust under increased complexity and heterogeneity of the object structure. Conclusions: These results support that FFMCT has the potential to meet prescribed image quality objectives, while decreasing radiation exposure to the patient. Tradeoffs between SNR and dose may not be eliminated, but might be more efficiently managed using FFMCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗