Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

An experimental investigation of the active control of sound transmission into a cylindrical enclosure

Preliminary results are reported from experiments involving the use of vibration sources in the active control of sound transmission into a cylindrical chamber (as in aircraft cabin-noise suppression). Electrodynamic shakers are used to provide vibrational excitation in a 3-m-high 900-mm-diameter cylindrical stainless-steel chamber with damped ends, subjected to single-frequency (384-Hz) sound from a horn driver located 150 mm from the cylinder midway along its length. When vibration is applied only diametrically opposite the source, rotation of the sound field occurs, but global attenuation is not achieved; with additional vibration applied at an angle of 225 deg to the source, moderate reduction of the global field is obtained. The need to identify and control all offending coupled structural/acoustic modes is indicated.

Snyder, S. D.↗

Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID

Purpose: The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. Methods: The APS has an active area of 5.4 x 5.4 cm and maximum full frame read-out rate of 20 frame s{sup -1}, with the option to read out a region-of-interest (ROI) at an increased rate. It was coupled to a 4 mm thick ZnWO4 scintillator which provided a quantum efficiency (QE) of 8% for a 6 MV x-ray treatment beam. The APS was compared with a standard iViewGT flat panel amorphous Silicon (a-Si) electronic portal imaging device (EPID), with a QE of 0.34% and a frame-rate of 2.5 frame s{sup -1}. To investigate the ability of the two systems to image markers, four gold cylinders of length 8 mm and diameter 0.8, 1.2, 1.6, and 2 mm were placed on a motion-platform. Images of the stationary markers were acquired using the APS at a frame-rate of 20 frame s{sup -1}, and a dose-rate of 143 MU min{sup -1} to avoid saturation. EPID images were acquired at the maximum frame-rate of 2.5 frame s{sup -1}, and a reduced dose-rate of 19 MU min{sup -1} to provide a similar dose per frame to the APS. Signal-to-noise ratio (SNR) of the background signal and contrast-to-noise ratio (CNR) of the marker signal relative to the background were evaluated for both imagers at doses of 0.125 to 2 MU. Results: Image quality and marker visibility was found to be greater in the APS with SNR {approx}5 times greater than in the EPID and CNR up to an order of magnitude greater for all four markers. To investigate the ability to image and track moving markers the motion-platform was moved to simulate a breathing cycle with period 6 s, amplitude 20 mm and maximum speed 13.2 mm s{sup -1}. At the minimum integration time of 50 ms a tracking algorithm applied to the APS data found all four markers with a success rate of {>=}92% and positional error {<=}90 {mu}m. At an integration time of 400 ms the smallest marker became difficult to detect when moving. The detection of moving markers using the a-Si EPID was difficult even at the maximum dose-rate of 592 MU min{sup -1} due to the lower QE and longer integration time of 400 ms. Conclusions: This work demonstrates that a fast read-out, high QE APS may be useful in the tracking of moving fiducial markers during radiotherapy. Further study is required to investigate the tracking of markers moving in 3D in a treatment beam attenuated by moving patient anatomy. This will require a larger sensor with ROI read-out to maintain speed and a manageable data-rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Analysis of Imaging and Measurements of Micrometer-Scale Fracture Aperture Fields Within a Heterogeneous Rock Using PET and X-ray CT

Knowledge of the spatial distribution of fracture apertures is essential for reliable characterization of flow and transport processes in fractured systems and for better understanding of physicochemical matrix–fracture interactions. Here, we propose and test two image-based methods, thereby extending the current experimental capabilities to characterize aperture size distribution in structurally heterogeneous geologic porous media noninvasively. The first approach utilizes an inversion method based on the dataset acquired from positron emission tomography (PET) and the second approach considers an extension of the classic missing attenuation technique that relies on clinical X-ray computed tomography (X-ray CT). Independent sets of imaging experiments are conducted on a fractured basalt core with heterogeneous matrix properties and aperture distributions to compare the two methodologies. A repeat of each experiment is conducted to verify the proposed workflows. The performance of these two imaging techniques is systematically evaluated through the analysis of signal-to-noise ratio, minimum fracture size detectability, and measurement errors. While both approaches provide a reliable estimation of fracture aperture distributions, PET yields a signal-to-noise ratio that is substantially higher than the corresponding X-ray CT measurements. Furthermore, uncertainties of the aperture values for PET are considerably lower ($\bar {\sigma}_{\text {d}} = 15\%$) compared to those obtained from X-ray CT ($\bar {\sigma}_{\text {d}} = 29\%$), allowing for the detection of minimum aperture sizes of 20 $\mu$m with 70% confidence level. Finally, these approaches provide key experimental tools for better understanding dynamic hydromechanical fracture properties in geologic systems.

58 GEOSCIENCES↗

Experimental determination of sound and high-speed flow interaction

An experimental facility for measuring the attenuation of sound at various frequencies and modes in a finite duct with high-speed flow (with or without an axial pressure gradient) is described. The facility consists of an anechoic chamber transonic compressor with inlets of different area variations (or axial gradients); sound of selected frequencies and modes is produced with eight circumferential acoustic drivers. The experimental results indicate that high Mach number inlets can increase noise propagation. In addition, an inlet with a constant axial gradient is found to have a better acoustic and aerodynamic performance than inlets of the same area ratio with steep gradients near the throat or exit.

Lumsdaine, E.↗

Status of the Olympus experiment at CRC

The status of the Olympus Propagation Experiment of the Communications Research Centre in Ottawa, Canada, is briefly summarized. Path attenuation measurements at multiple frequencies correlated with concurrent dual polarized radar data provide a unique method to investigate propagation effects. An experiment of this type is being implemented by the Communications Research Centre (CRC) on the grounds of the National Research Council of Canada in Ottawa. Beacon receivers monitor signals from the Olympus satellite at 12.5, 19.77, and 29.66 GHz at a path elevation angle of 14.2 deg. Sky noise radiometers operating near the same frequencies and pointed along the same path provide additional propagation information. A colocated dual-polarized 9.6-GHz radar probes the precipitation state on the path, permitting identification of precipitation regimes that cause the observed impairments. The Olympus experiment configuration is displayed pictorially. Information on path propagation phenomena can be deduced by correlating the radar, beacon, and sky noise data. Melting layer effects and propagation losses for higher time percentages are prime interests. Data collected by Diversitel Communications during equipment verification tests are presented.

Rogers, David V.↗

Further Development and Assessment of a Broadband Liner Optimization Process

The utilization of advanced fan designs (including higher bypass ratios) and shorter engine nacelles has highlighted a need for increased fan noise reduction over a broader frequency range. Thus, improved broadband liner designs must account for these constraints and, where applicable, take advantage of advanced manufacturing techniques that have opened new possibilities for novel configurations. This work focuses on the use of an established broadband acoustic liner optimization process to design a variable-depth, multi-degree of freedom liner for a high speed fan. Specifically, in-duct attenuation predictions with a statistical source model are used to obtain optimum impedance spectra over the conditions of interest. The predicted optimum impedance information is then used with acoustic liner modeling tools to design a liner aimed at producing impedance spectra that most closely match the predicted optimum values. The multi-degree of freedom design is carried through design, fabrication, and testing. In-duct attenuation predictions compare well with measured data and the multi-degree of freedom liner is shown to outperform a more conventional liner over a range of flow conditions. These promising results provide further confidence in the design tool, as well as the enhancements made to the overall design process.

Nark, Douglas M.↗

Electromagnetic Basis of Metabolism and Heredity

Living organisms control their cellular biological clocks to maintain functional oscillation of the redox cycle, also called the "metabolic cycle" or "respiratory cycle". Organization of cellular processes requires parallel processing on a synchronized time-base. These clocks coordinate the timing of all biochemical processes in the cell, including energy production, DNA replication, and RNA transcription. When this universal time keeping function is perturbed by exogenous induction of reactive oxygen species (ROS), the rate of metabolism changes. This causes oxidative stress, aging and mutations. Therefore, good temporal coordination of the redox cycle not only actively prevents chemical conflict between the reductive and oxidative partial reactions; it also maintains genome integrity and lifespan. Moreover, this universal biochemical rhythm can be disrupted by ROS induction in vivo. This in turn can be achieved by blocking the electron transport chain either endogenously or exogenously by various metabolites, e.g. hydrogen sulfide (H2S), highly diffusible drugs, and carbon monoxide (CO). Alternatively, the electron transport in vivo can be attenuated via a coherent or interfering transfer of energy from exogenous ultralow frequency (ULF) and extremely low frequency (ELF) electromagnetic (EM) fields, suggesting that-on Earth-such ambient fields are an omnipresent (and probably crucially important) factor for the time-setting basis of universal biochemical reactions in living cells. Our work demonstrated previously un-described evidence for quantum effects in biology by electromagnetic coupling below thermal noise at the universal electron transport chain (ETC) in vivo.

Electromagnetic↗

Optimizing signal-to-error ratio in standing wave ultrasonic measurements

Standing wave ultrasonic techniques for the measurement of very small changes in acoustic attenuation and phase velocity are discussed. Enhanced sensitivity to these small changes was achieved by making the specimen part of a composite ultrasonic resonator. It was found that a point of maximum sensitivity on the response of such an ultrasonic resonator need not coincide with a point of maximum signal-to-error ratio. A model is presented and analyzed which takes into account error due to long term (low frequency) noise effects such as gain drifts and dc level shifts. This model yields a quantitative value for the signal-to-error ratio in which the signal is defined as the ideal change in the monitored response and the error as the difference between the experimentally measured change and the signal. The specific frequency dependent forms for the ultrasonic response and the sensitivity enhancement factor were used to predict the operating point on a mechanical resonance corresponding to maximum signal-to-error ratio.

Brown, J. J.↗

A sea-level recorder for tectonic studies

In the past tide gauges have provided valuable information concerning the vertical ground deformation associated with major earthquakes. Although tide-gauge data contains numerous sources of noise, a spacing of less than 40 km between gauges is indicated for a useful study of dilatant behavior, and a spacing of less than 80 km may be adequate for the study of crustal downwarping in island arcs. An inexpensive tide gauge which is designed to provide a continuous record of sea level with a measurement precision of 1 mm is described. Hydraulic filtering is incorporated into the instrument to attenuate daily tides relative to longer period variations of sea level. The instrument is designed to operate from flashlight batteries for a year unattended and to withstand temporary submersion as might be caused by tsunamis. Several of these sea-level recorders have been installed in seismic gaps in the Aleutians and in the Caribbean.

Bilham, R.↗

Potential uses of vacuum bubbles in noise and vibration control

Vacuum bubbles are new acoustic elements which are dynamically more compliant than the gas volume they replace, but which are statically robust. They are made of a thin metallic shell with vacuum in their cavity. Consequently, they pose no danger in terms of contamination or fire hazard. The potential of the vacuum bubble concept for noise and vibration control was assessed with special emphases on spacecraft and aircraft applications. The following potential uses were identified: (1) as a cladding, to reduce sound radiation of vibrating surfaces and the sound excitation of structures, (2) as a screen, to reflect or absorb an incident sound wave, and (3) as a liner, to increase low frequency sound transmission loss of double walls and to increase the low frequency sound attenuation of muffler baffles. It was found that geometric and material parameters must be controlled to a very high accuracy to obtain optimal performance and that performance is highly sensitive to variations in static pressure. Consequently, it was concluded that vacuum bubbles have more potential in spacecraft applications where static pressure is controlled more than in aircraft applications where large fluctuations in static pressure are common.

Ver, Istvan L.↗

Advanced AE Techniques in Composite Materials Research

Advanced, waveform based acoustic emission (AE) techniques have been successfully used to evaluate damage mechanisms in laboratory testing of composite coupons. An example is presented in which the initiation of transverse matrix cracking was monitored. In these tests, broad band, high fidelity acoustic sensors were used to detect signals which were then digitized and stored for analysis. Analysis techniques were based on plate mode wave propagation characteristics. This approach, more recently referred to as Modal AE, provides an enhanced capability to discriminate and eliminate noise signals from those generated by damage mechanisms. This technique also allows much more precise source location than conventional, threshold crossing arrival time determination techniques. To apply Modal AE concepts to the interpretation of AE on larger composite specimens or structures, the effects of modal wave propagation over larger distances and through structural complexities must be well characterized and understood. To demonstrate these effects, measurements of the far field, peak amplitude attenuation of the extensional and flexural plate mode components of broad band simulated AE signals in large composite panels are discussed. These measurements demonstrated that the flexural mode attenuation is dominated by dispersion effects. Thus, it is significantly affected by the thickness of the composite plate. Furthermore, the flexural mode attenuation can be significantly larger than that of the extensional mode even though its peak amplitude consists of much lower frequency components.

Prosser, William H.↗

Evaluation of KDP Estimation Algorithm Performance in Rain Using a Known-Truth Framework

Accurate estimation of specific differential phase ( K DP ) is necessary for rain rate estimation, attenuation correction, and hydrometeor classification algorithms. There are numerous published methods to process polarimetric radar observations of propagation differential phase shift (Φ DP ) and estimate K DP , but the corresponding K DP estimate uncertainty is unquantified. This study provides guidance on how commonly used K DP estimation algorithms perform in various environments. Here, we create numerous synthetic (“true”) K DP profiles, integrate over them to obtain “smoothed” Φ DP , and then add noise typical of S-band operational weather radar measurements. Each algorithm is applied to our noisy Φ DP profiles and compared to the true K DP profile such that the errors and uncertainty are quantified. The synthetic K DP profiles are Gaussian in shape, which allows systematic variations in their magnitude and width to determine how each algorithm performs in smooth, slowly changing K DP profiles, as well as steep profiles. Results demonstrate that algorithm performance is dependent on the Φ DP field received. These results are further supported by an error analysis of each algorithm for two more complicated synthetic K DP profiles. Some K DP algorithms allow users to change various tuning parameters; a subset of these tuning parameters is tested to provide guidance on how changing these parameters impacts algorithm performance. We then provide evidence that our known-truth framework provides insight into algorithm performance in observed data through two case studies.

54 ENVIRONMENTAL SCIENCES↗

Comparison of mesospheric ozone measurements using the LRIR and UVMCS satellite instruments

A comparison between mesospheric ozone profiles determined by two radically different satellite-borne instruments is presented for the period of July to November, 1975. The Limb Radiance Inversion Radiometer measured 9.6-micron O3 emission, while the Ultraviolet Multiple Channel Spectrometer measured the atmospheric attenuation of solar ultraviolet radiation during passage of the OSO-8 satellite across the terminator. Only nine near coincident measurements were found. The individual instruments have estimated precision errors of + or - 10 to 15 percent. Agreement between ozone values as measured by the two techniques for specific cases varies between 10 and 20 percent. The statistical correlation is positive and significant at all altitudes where both instruments had reasonable signal-to-noise ratio. A maximum correlation of 0.76 occurred at 0.3 mb (about 59 km).

Millier, F.↗

Finite element-integral simulation of static and flight fan noise radiation from the JT15D turbofan engine

An iterative finite element integral technique is used to predict the sound field radiated from the JT15D turbofan inlet. The sound field is divided into two regions: the sound field within and near the inlet which is computed using the finite element method and the radiation field beyond the inlet which is calculated using an integral solution technique. The velocity potential formulation of the acoustic wave equation was employed in the program. For some single mode JT15D data, the theory and experiment are in good agreement for the far field radiation pattern as well as suppressor attenuation. Also, the computer program is used to simulate flight effects that cannot be performed on a ground static test stand.

Baumeister, K. J.↗

IGM damping wing constraints on the tail end of reionization from the enlarged XQR-30 sample

ABSTRACT The attenuation of Lyα photons by neutral hydrogen in the intergalactic medium (IGM) at z ≳ 5 continues to be a powerful probe for studying the epoch of reionization. Given a framework to estimate the intrinsic (true) Lyα emission of high-z sources, one can infer the ionization state of the IGM during reionization. In this work, we use the enlarged XQR-30 sample of 42 high-resolution and high signal-to-noise quasar spectra between $5.8\lesssim \, z\lesssim \, 6.6$ obtained with VLT/X-shooter to place constraints on the IGM neutral fraction. This is achieved using our existing Bayesian QSO reconstruction framework which accounts for uncertainties such as the: (i) posterior distribution of predicted intrinsic Lyα emission profiles (obtained via covariance matrix reconstruction of the Lyα and N v emission lines from unattenuated high-ionization emission line profiles; C iv, Si iv + O iv], and C iii]) and (ii) distribution of ionized regions within the IGM using synthetic damping wing profiles drawn from a 1.63 Gpc3 reionization simulation. Following careful quality control, we used 23 of the 42 available QSOs to obtain constraints/limits on the IGM neutral fraction during the tail-end of reionization. Our median and 68th percentile constraints on the IGM neutral fraction are: $0.20\substack{+0.14 -0.12}$ and $0.29\substack{+0.14 -0.13}$ at z = 6.15 and 6.35. Further, we also report 68th percentile upper limits of $\bar{x}_{\mathrm{H\, {\small I}}{}} \lt 0.21$, 0.20, 0.21, and 0.18 at z = 5.8, 5.95, 6.05, and 6.55. These results imply reionization is still ongoing at $5.8\lesssim \, z\lesssim \, 6.55$, consistent with previous results from XQR-30 (dark fraction and Lyα forest) along with other observational probes considered in the literature.

Greig, B. (ORCID:0000000240852094)↗

The promise of advanced technology for future air transports

Progress in all weather 4-D navigation and wake vortex attenuation research is discussed and the concept of time based metering of aircraft is recommended for increased emphasis. The far term advances in aircraft efficiency were shown to be skin friction reduction and advanced configuration types. The promise of very large aircraft, possibly all wing aircraft is discussed, as is an advanced concept for an aerial relay transportation system. Very significant technological developments were identified that can improve supersonic transport performance and reduce noise. The hypersonic transport was proposed as the ultimate step in air transportation in the atmosphere. Progress in the key technology areas of propulsion and structures was reviewed. Finally, the impact of alternate fuels on future air transports was considered and shown not to be a growth constraint.

Bower, R. E.↗

Fundamental Noise Characterization of a Ducted Propeller in Hover

Unmanned aerial vehicles (UAVs) are currently being used for reconnaissance missions, tactical surveillance, and infrastructure inspection. When legislation allows it, these devices will provide additional services close to inhabited areas, which could lead to noise complaints. On most UAVs, the propellers are the dominant source of noise. As a result, researchers have studied the impact of propeller shape and blade count on noise. Much of this work, however, has focused on isolated propellers. While different UAV concepts are equipped with ducts for aerodynamic and protection reasons, few studies focus on the acoustic benefit of ducts, as is achieved, for example, on turbofan aircraft. The objectives of this paper are: first, to simulate the noise radiation of a UAV propeller in static conditions based on its location in a hard wall duct; second, to analyze the contribution of the different acoustic source components (i.e., thrust, torque, and thickness); and third, to validate the approach with experiments conducted in the NASA Small Hover Anechoic Chamber over a range of propeller rotation rates. For the propeller and duct geometries considered in this experiment, it is shown that the best attenuation is achieved when the propeller is centered axially in the duct because of interference between upstream and downstream radiated waves.

ducted propeller↗

WE-AB-BRB-09: Real Time In Vivo Scintillating Fiber Array Detector for Medical LINACS

Purpose: An in vivo transmission scintillation fiber detector was developed to monitor patient treatment in real time for the enhancement of patient safety and treatment accuracy. The detector system is capable of monitoring each pulse from a medical LINAC during treatment to determine the dose delivered as treatment progresses. Methods: The detector system consists of 60 parallel scintillating fibers coupled to fast data processing optoelectronics that can monitor the beam fluence in real time. Each 2.5mm{sup 2} square fiber is aligned with an MLC leaf pair and is long enough to capture a 40cm field. The fibers are embedded within a water equivalent polymer substrate that is secured in the LINAC accessory tray. The fibers are coupled to high speed photosensors and front end amplifiers that filter noise and pass each pulse to a high speed analog-to-digital converter. The system components are capable of detecting pulse repetition times shorter than what is delivered by a medical LINAC to ensure true real time data acquisition. Results: The system was able to capture and record the signal from each linac pulse and display the information in real time with no pulse pile up. It was found that the fiber array attenuates 2.65% of the beam which can easily be compensated for in treatment planning. The fibers responded linearly with dose, are independent of clinical beam energies, and are independent of dose rate. Calibration of the system was performed as a function of beam energy, beam size, dose rate, and monitor units to optimize beam fluence error detection. Conclusion: The detector system presented provides true real time in vivo beam monitoring to enhance patient safety and treatment delivery accuracy. Furthermore, the detector can be used for current patient specific QA.

60 APPLIED LIFE SCIENCES↗