Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NCSP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Digitizing Curves from LA-10860 to be Used in CritView

This report documents the digitization of figures from LA-10860-MS in order to import the data into the CritView software application. The original figures were created by Los Alamos National Laboratory and the latest revision was released in 1986. All figures were digitized using Engauge Digitizer (ver. 12.1) .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 240 Pu(n,f) Prompt Fission Neutron Spectra with Chi-Nu

The DOE Nuclear Criticality Safety Program has funded a multi-year effort to measure the 240 Pu(n,f) Prompt Fission Neutron Spectrum at Chi-Nu. This project is a joint LANL-LLNL effort, involving the preparation of 12 240 Pu foils and construction of a Parallel-Plate Avalanche Counter at LLNL, with subsequent measurements of the 240 Pu(n,f) PFNS at the Chi-Nu beamline at the Los Alamos Neutron Science Center’s Weapons Neutron Research facility (LANSCE/WNR). We expect the PPAC to be ready in time to perform the measurements this run cycle.

240Pu Foils↗

Results of time-of-flight transmission measurements for 142 Ce at a 50 m station of GELINA

Transmission measurements have been performed at the time-of-flight facility GELINA to provide data for a new evaluation of neutron resonance parameters for 142 Ce. The measurements were carried out at a 50 m transmission station using a Li-glass scintillator with the accelerator operating at 400 Hz. This report provides the experimental details required to deliver the data to the EXFOR data library, maintained by the International Network of Nuclear Reaction Data Centres (NRDC). The experimental conditions and data reduction procedures are described. In addition, the full covariance information based on the AGS concept is given such that resonance parameters together with their covariances can be derived in a least-squares adjustment to the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALE Calculations Replicating ARH-600 Data

This report documents Standardized Computer Analyses for Licensing Evaluation (SCALE) calculations replicating data from the ARH-600 criticality handbook. These calculations complement those reproduced with MCNP in PRC-NS-00009. Calculations were performed with SCALE version 6.1, using the v7-238 cross section library. The original ARH-600 data were calculated by the Atlantic Richfield Hanford (ARH) Company starting in the 1960s, and Monte Carlo N-Particle (MCNP) calculations were performed by the Hanford Plateau Remediation Company in 2010. This report is not intended to replace final analysis of fissile systems by qualified criticality personnel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update of CEA DES Criticality-Safety Activities and Perspectives [Slides]

Neutronics staff at CEA DES are in charge of a whole set of modeling and simulation tools for neutronics: nuclear data evaluation and processing, transport codes development, calculation sequences edition, verification, validation and uncertainty analysis. Advanced user groups are in charge of specific nuclear analysis in reactor physics, fuel cycle, criticality-safety, radiation shielding and nuclear instrumentation for CEA and its partners, at all stages of nuclear facilities life cycle. CEA is willing to participate/collaborate on the following issues: detector design, experiments, analysis and evaluation, DH validation by combining TAGS measurements with Fission Yield variance-covariance matrices.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the Slide Rule Update - Phase 4 Plutonium Configurations – Delayed Gamma [Slides]

The fourth phase of Slide-Rule update gives a calculation scheme for DFG doses and its application to five plutonium material, as well as comparisons between radiation transport and depletion codes such as MCNP, SCALE, COG and FISPACT. Overall, DFG dose rates calculated by each laboratory led to consistent results. Extra effort is under way to identify the cause of the remaining differences, especially for case 2, by comparing precisely the gamma source, and particularly nuclides inventories.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chlorine Worth Study in Support of PF-4 Operations [Slides]

The primary concern of this study is if experiments can be designed/conducted to provide technical justification to NCS in order to increase mass limits. This goal is in direct support of 30 pits per year mission, one of the top priorities for NNSA. The accelerated timeline is as follows: Initial tasking, June 2020; preliminary design completion (CED-1 equivalent), November 2020; final design completion (CED-2 equivalent), March 2021; part receipt and inspection completion (CED-3a equivalent), October 2021; experiment execution (CED-3b equivalent), December 2021; experiment documentation write-up completion (start CED-4a equivalent), January 2022; and ICSBEP target (CED-4a equivalent), Fall 2022.

2019 ARCHIMEDES LDRD project↗

Delayed Critical Enriched Uranium Metal, 7-in.-diam. Cylinder with Thin Stainless Steel Top and Bottom Reflectors

Three 7 in. diameter highly enriched uranium (HEU; 93.17 wt % 235 U) metal cylinders were assembled on the vertical assembly machine of the Oak Ridge Critical Experiments Facility (ORCEF) with thin stainless steel reflectors (0.5, 1, and 2 in. thick) on the top and bottom. These experiments were performed during January 13–25, 1965, and used seven operational days at ORCEF. Before these experiments, unreflected and unmoderated 7 in. diameter HEU metal cylinders had been assembled to delayed criticality at ORCEF, and the results were benchmarked in HEU-MET-FAST-051. In addition to the critical experiments, the prompt neutron decay constant was measured via the Rossi-α technique, and those results are also presented in this report. To achieve near-delayed-critical systems, 5 × 5 × 0.03125 in. rectangular uranium metal parts were used on top of 7 in. diameter cylinders inside the top reflector. The delayed critical configuration from the three experiments described herein are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Benchmark Evaluation Program (ICSBEP), coordinated by the Nuclear Energy Agency, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainty in $k_{eff}$ is expected to be as low as ±0.0002. The prompt neutron time decay data could be the basis of an International Reactor Physics Evaluation Program benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fitting $\overline{\nu}$ for minor Pu isotopes

After successful fitting of prompt $\overline{\nu}$ for 235 U, 238 U, and 239 Pu(n,f) using CGMF, we will move on to the minor plutonium isotopes. Minor isotopes pose a greater challenge both because there is less data available and we do not, by default, have parametrizations in CGMF already. To mitigate these challenges— and provide consistency within CGMF—we will take a stepped approach to the optimization. Continuing from the 239 Pu work, we will then fit 241 Pu(n,f) $\overline{\nu}$, where there is also a number of experimental measurements, keeping consistency between the parameters that are included in the calculation for 239 Pu and 241 Pu. With these parametrizations settled, we can consistently optimize 240 Pu(n,f) $\overline{\nu}$. Following that step, we will move on to 242 Pu(n,f) (and increasing neutron number) and 238 Pu(n,f) (and decreasing neutron number). By including the fissioning systems in this manner, we should be able to minimize the unknown parameters in CGMF. We will possibly also be able to develop systematics for the CGMF input parameters along the Pu isotopic chain. This work can serve as a guide to broadening the reactions available in CGMF. In this short report, we first give an example of how we have updated CGMF to include 240 Pu(n,f) and 242 Pu(n,f), keeping consistency with the current 239 Pu and 241 Pu calculations, but without rigorous optimization (Sec. 2). Then, we will shown in Section 3 what experimental data exist for the various isotopes to provide some insight into why 241 Pu and 239 Pu are used as anchor points.

07 ISOTOPE AND RADIATION SOURCES↗

IER-523: Feasibility of Experiments Focused on Measuring the Effects of UO 2 BeO Material on Critical Configurations using 7uPCX [Slides]

Sandia National Labs has access to unused ACRR fuel, which is unique in its enrichment 35% and material composition BeO. ACRR fuel is available in quantities well above what is needed for experiments. Two experiment concepts have been investigated: UO 2 BeO fuel elements and pellets with 7uPCX fuel. The worth of UO 2 BeO is large enough to be well above the anticipated experiment uncertainties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experiments to Measure the Inversion Point of the Isothermal Reactivity Coefficient in a Water-Moderated Pin-Fueled Critical Assembly at Sandia [Slides]

Two experiment series are planned to measure temperature effects in the Sandia Critical Experiments. The first series (IER-304) will measure the critical size of a fuel rod configuration at several temperatures. The second series (IER-452) will measure the inversion temperature of the isothermal reactivity coefficient in the Sandia critical assembly. Each experiment in the second series will be preceded by one or more experiments in the first series. This presentation addresses the conceptual design of the inversion temperature experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluated 238 U(n,f) Average Prompt Fission Neutron Multiplicities Including the CGMF Model

This report documents an evaluation of the average prompt fission neutron multiplicity, $\overline{v}_p$, of 238 U from 800 keV to MeV. This evaluation had to be re-done from “scratch” as the input to previous $\overline{v}_p$ evaluations, specifically ENDF/B-VIII.0, was not found. That means that all available experimental data were re-analyzed and uncertainties were re-estimated. The new evaluated 238 U $\overline{v}_p$ based on only experimental data differs distinctly from ENDF/B-VIII.0 $\overline{v}_p$ from 2 to 4.5 MeV, and from 6 to 7 MeV, and is otherwise similar. The difference from 2 to 4.5 MeV stems from the fact that ENDF/B-VIII.0 was tweaked in this energy range to data of Frehaut, while two other, equally trustworthy, data sets would indicate an evaluated 238 U $\overline{v}_p$ that is up to 2% higher. Also, second chance fission in ENDF/B-VIII.0 was smoothed over from 6–7 MeV. Another major difference to ENDF/B-VIII.0 is that one of the evaluations presented here includes model information from the Hauser-Feshbach fission fragment decay code CGMF, while ENDF/B-VIII.0 is based purely on experimental data. CGMF links several fission quantities with each other; $\overline{v}_p$ is predicted by assumptions made on, e.g., pre-neutron emission yields as a function of mass, the total kinetic energy, or spin and parity of fission fragments. This allows to validate the new 238 U $\overline{v}_p$ by using CGMF parameters obtained from fitting to experimental 238 U $\overline{v}_p$ to predict yields as a function of mass, the average total kinetic energy, or the mean energy of the prompt fission neutron spectrum. These model-predicted values can then be compared to experimental and evaluated data. The model-predicted fission-observable values using evaluated parameters obtained here are reasonably close to experimental data for some observables, but are farther away from experimental data related to TKE observables. In addition to that, the evaluated 238 U(n,f) $\overline{v}_p$ shows similar deviations from ENDF/B-VIII.0 as for the evaluation with only experimental data. This difference is expected to lead to changes in simulated effective neutron multiplication factor, $k_{eff}$ of ICSBEP critical assemblies that are sensitive to 238 U in the fast range (BigTen, Flattop, Flattop-Pu). These changes in $k_{eff}$ need to be counter-balanced. Chi-Nu PFNS experimental data are expected to be released in the next few months that might lead to the needed changes in the PFNS. Until then, we hold off in benchmarking the new 238 U(n,f) $\overline{v}_p$ as well as submitting it to ENDF/B-VIII.1. Also, new high-precision 238 U $\overline{v}_p$ are expected to be measured by the CEA in the next two years that will shed further light on question on 238 U $\overline{v}_p$ from 2–4.5 and 6–7 MeV.

238U↗

Analysis of a Bulk 237 Np Oxide Sample for Trace Actinides

A neptunium oxide sample was dissolved and trace actinide constituents were measured by isotope dilution ICP-MS (for 239–244 Pu, 233–238 U, 237 Np, 241–243 Am) and alpha spectrometry ( 238 Pu, 242 Cm, 244 Cm). This material contained significant quantities of transuranic elements, notably americium and curium. The isotopic composition of the material will continue to evolve over time due to radioactive decay; the measurements reported here include all isotopes decay corrected to a reference date of 1/1/2022. These factors may be considerations in criticality studies of the related 237 Np sphere.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MCNP ® Code Version 6.3.0 Theory & User Manual

This document acts as a repository of knowledge for the Monte Carlo N-Particle (MCNP) transport computer code. It is maintained alongside the source code and attempts to introduce new users and re-familiarize experienced users with the theory and practices of using the MCNP code for the wide range of particle transport analyses that it is appropriate for. The latest version of the MCNP code, version 6.3.0, provides the Monte Carlo particle transport community with the latest feature developments and bug fixes in the MCNP code. The MCNP code version 6.0 and later is also known as the MCNP6 code.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Integral Experiment Final Design for Thermal/Epithermal eXperiments (TEX) Plutonium Additional Mixed Spectrum Configurations

This report presents the final design (CED-2) for three additional mixed-spectra configurations for plutonium Thermal/Epithermal eXperiments (TEX) to target the intermediate energy region (IER-553). The baseline cases of IER-184 (PU-MET-MIXED-002 [2]) spanned the entire fission energy spectrum. Case 3, which had a median fission energy (MFE) of approximately 6E-5 MeV and had a fission fraction of about 42% in the intermediate energy range, resulted in a $k_{eff}$ overestimation of 1.1%. Compared to 749 previous ICSBEP plutonium benchmarks, the baseline cases accurately predicted the experiments in the thermal and fast regions where the majority of benchmarks inhabit. The benchmarks in the intermediate energy region to date are sparse and overestimate $k_{eff}$ with an average C/E between 1.02 and 1.03. The additional proposed configurations span the whole of the intermediate energy region. The experimental design utilizes the plutonium/aluminum metal alloy Zero Power Physics Reactor (ZPPR) Plutonium-Aluminum No-Nickel (PANN) plates with varying polyethylene moderator thicknesses to span the intermediate fission energy region. Each of the cases have varying fractions of thermal, intermediate, and fast fissions. The designs were chosen to maximize the intermediate energy fraction. The experiment will take place on the universal critical assembly machine, Planet. The layers will be split as equally as possible between the lower platen and the upper stationary platform of Planet. The upper half of the experimental configuration will also have an upper reflector of polyethylene of specified thicknesses to achieve criticality when the lower platen is raised fully. The previous IER-184 configurations, specifically Case 3, were used to determine the configurations for the additional experiments and neutronics calculations were used to fine-tune the configurations to ensure criticality. The quadrature sum uncertainty in Δ$k_{eff}$ for Case 3 in PU-MET-MIXED-002 was found to be 0.00219. Section 3.8 gives a detailed description of the uncertainties calculated. The additional configurations, which are based directly on Case 3, are expected to have similar uncertainties. However, it is possible to reduce the overall uncertainty of Δ$k_{eff}$ for the additional configurations using the knowledge obtained from the calculations in the benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗