Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo method.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Preliminary Results of a New Deterministic Iterative Image Reconstruction Algorithm - Paper 117

Iterative reconstruction techniques have become the standard for Single Photon Emission Computed Tomography (SPECT). Advances in computing have allowed these techniques to incorporate more and more detail; however, computation time must be balanced against increased detail. Monte Carlo methods are generally used for modeling the physics of a SPECT study, but can have long computation times. Advances in Monte Carlo-based scatter correction have shown reasonable results, but scatter estimation by measuring narrow energy windows remains more common. An iterative reconstruction technique using a deterministic transport code has been proposed as an alternative. This paper presents preliminary results of the new technique in which the TITAN deterministic code completes the forward projection step in a maximum likelihood expectation maximization (ML-EM) reconstruction of SPECT data. The effectiveness of the deterministic algorithm is examined for a 2-dimensional phantom. This work demonstrates the feasibility of using the TITAN code in an iterative reconstruction algorithm. The appropriate deterministic parameters were chosen by comparing sinograms produced with different mesh sizes, quadrature sets, and anisotropic scattering orders. The TITAN code was then successfully used as the forward projection step in an iterative reconstruction algorithm with a 2-dimensional homogeneous phantom. The impact of deterministic parameters on reconstruction quality is being investigated, along with the incorporation of a smoothing filter. The TITAN source code is being modified to include the ML-EM algorithm and iteration steps. This will significantly improve computation time by eliminating the repeated reading and writing of files for each iteration and allowing some steps to be completed in parallel. Further testing of the new reconstruction algorithm for more realistic phantoms is also underway. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Critical Relaxation of a Three-Dimensional Fully Frustrated Ising Model

Critical relaxation from the low-temperature ordered state of the three-dimensional fully frustrated Ising model on a simple cubic lattice is studied by the short-time dynamics method. Cubic systems with periodic boundary conditions and linear sizes of L = 32, 64, 96, and 128 in each crystallographic direction are studied. Calculations were carried out by the Monte Carlo method using the standard Metropolis algorithm. The static critical exponents for the magnetization and correlation radius and the dynamic critical exponents are calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Force-extension curves for broken-rod macromolecules: Dramatic effects of different probing methods for two and three rods

We study force-extension curves of a single semiflexible chain consisting of several rigid rods connected by flexible spacers. The atomic force microscopy and laser optical or magnetic tweezers apparatus stretching these rod-coil macromolecules are discussed. In addition, the stretching by external isotropic force is analyzed. The main attention is focused on computer simulation and analytical results. We demonstrate that the force-extension curves for rod-coil chains composed of two or three rods of equal length differ not only quantitatively but also qualitatively in different probe methods. These curves have an anomalous shape for a chain of two rods. End-to-end distributions of rod-coil chains are calculated by Monte Carlo method and compared with analytical equations. The influence of the spacer’s length on the force-extension curves in different probe methods is analyzed. The results can be useful for interpreting experiments on the stretching of rod-coil block-copolymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-226: Correction of a Standard Model-Based Dose Calculator Using Measurement Data

Purpose: To propose a hybrid method that combines advantages of the model-based and measurement-based method for independent dose calculation. Modeled-based dose calculation, such as collapsed-cone-convolution/superposition (CCCS) or the Monte-Carlo method, models dose deposition in the patient body accurately; however, due to lack of detail knowledge about the linear accelerator (LINAC) head, commissioning for an arbitrary machine is tedious and challenging in case of hardware changes. On the contrary, the measurement-based method characterizes the beam property accurately but lacks the capability of dose disposition modeling in heterogeneous media. Methods: We used a standard CCCS calculator, which is commissioned by published data, as the standard model calculator. For a given machine, water phantom measurements were acquired. A set of dose distributions were also calculated using the CCCS for the same setup. The difference between the measurements and the CCCS results were tabulated and used as the commissioning data for a measurement based calculator. Here we used a direct-ray-tracing calculator (ΔDRT). The proposed independent dose calculation consists of the following steps: 1. calculate D-model using CCCS. 2. calculate D-ΔDRT using ΔDRT. 3. combine Results: D=D-model+D-ΔDRT. Results: The hybrid dose calculation was tested on digital phantoms and patient CT data for standard fields and IMRT plan. The results were compared to dose calculated by the treatment planning system (TPS). The agreement of the hybrid and the TPS was within 3%, 3 mm for over 98% of the volume for phantom studies and lung patients. Conclusion: The proposed hybrid method uses the same commissioning data as those for the measurement-based method and can be easily extended to any non-standard LINAC. The results met the accuracy, independence, and simple commissioning criteria for an independent dose calculator.

60 APPLIED LIFE SCIENCES↗

Dosimetric optimization of a conical breast brachytherapy applicator for improved skin dose sparing

Purpose: Both the AccuBoost D-shaped and round applicators have been dosimetrically characterized and clinically used to treat patients with breast cancer. While the round applicators provide conformal dose coverage, under certain clinical circumstances the breast skin dose may be higher than preferred. The purpose of this study was to modify the round applicators to minimize skin dose while not substantially affecting dose uniformity within the target volume and reducing the treatment time. Methods: In order to irradiate the intended volume while sparing critical structures such as the skin, the current round applicator design has been augmented through the addition of an internal truncated cone (i.e., frustum) shield. Monte Carlo methods and clinical constraints were used to design the optimal cone applicator. With the cone applicator now defined as the entire assembly including the surrounding tungsten-alloy shell holding the HDR {sup 192}Ir source catheter, the applicator height was reduced to diminish the treatment time while minimizing skin dose. Monte Carlo simulation results were validated using both radiochromic film and ionization chamber measurements based on established techniques. Results: The optimal cone applicators diminished the maximum skin dose by 15%-32% (based on the applicator diameter and breast separation) with the tumor dose reduced by less than 3% for a constant exposure time. Furthermore, reduction in applicator height diminished the treatment time by up to 30%. Radiochromic film and ionization chamber dosimetric results in phantom agreed with Monte Carlo simulation results typically within 3%. Larger differences were outside the treatment volume in low dose regions or associated with differences between the measurement and Monte Carlo simulation environments. Conclusions: A new radiotherapy treatment device was developed and dosimetrically characterized. This set of applicators significantly reduces the skin dose and treatment time while retaining uniform target dose.

60 APPLIED LIFE SCIENCES↗

Efficient Monte Carlo event generation for neutrino-nucleus exclusive cross sections

Modern neutrino-nucleus cross section computations need to incorporate sophisticated nuclear models to achieve greater predictive precision. However, the computational complexity of these advanced models often limits their practicality for experimental analyses. To address this challenge, we introduce a new Monte Carlo method utilizing normalizing flows to generate surrogate cross sections that closely approximate those of the original model while significantly reducing computational overhead. As a case study, we built a Monte Carlo event generator for the neutrino-nucleus cross section model developed by the Ghent group. This model employs a Hartree-Fock procedure to establish a quantum mechanical framework in which both the bound and scattering nucleon states are solutions to the mean-field nuclear potential. The surrogate cross sections generated by our method demonstrate excellent accuracy with a relative effective sample size of more than 98.4%, providing a computationally efficient alternative to traditional Monte Carlo sampling methods for differential cross sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Neutron Spectrum and Control Rod Worth Measurements in Several ZPPR-15 Loadings

This paper discusses the analysis of neutron spectrum and control rod reactivity worth measurements with deterministic and Monte Carlo methods. Deterministic results are obtained with 3D reactor models generated with the BuildZPRModel tools developed at ANL. The Monte Carlo simulations are performed with MCNP6 and are based on 3D models that include all geometric details ('as built' models). This study also shows the application of the cross section processing options recently implemented in BuildZPRModel that are based on the leakage and TWODANT method to take better into account the coupling effects among the different reactor zones.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi Scale Study of Self-irradiation Effects in Plutonium Alloys

Experimental measurements have shown that plutonium alloys exhibit changes of their macroscopic as well as microscopic properties. For example, a swelling of plutonium alloys was observed with aging with dilatometry and X-ray diffraction. The main idea to explain these changes rises in self irradiation undergoing by those materials. Plutonium {alpha} decay is at the origin of displacements cascades creating a large amount of structural defects. These later by annihilation and recombination give rise to larger defects such as voids and clusters. The aim of this work is to study the occurrence of such phenomena combining ab-initio, molecular dynamic and Monte Carlo methods in a coherent multi-scale approach which would help to understand long term behavior of structural defects and consequences of self irradiation. We show that plutonium does not seem to behave like other metals under ion irradiation. We discuss results obtained for high energy displacements cascade simulations. After parametric study of displacements cascade simulations combining temperature and cascade energy has been exposed, superposition of low energies displacements cascades is discussed as a method to construct realistic defect microstructures and to reach a rational use of computational time. At the end, we will present results of preliminary Monte Carlo simulations based on our molecular dynamic data which show that the spatial correlation of the stable defects populations created by the cascades seems to have a great influence on the predicted swelling. (authors)

36 MATERIALS SCIENCE↗

Phase diagram of Rydberg atoms with repulsive van der Waals interaction

We report a quantum Monte Carlo calculation of the phase diagram of bosons interacting with a repulsive inverse sixth power pair potential, a model for assemblies of Rydberg atoms in the local van der Waals blockade regime. The model can be parametrized in terms of just two parameters, the reduced density and temperature. Solidification happens to the fcc phase. At zero temperature, the transition density is found with the diffusion Monte Carlo method at density {rho}=3.9 (({Dirac_h}/2{pi}){sup 2}/mC{sub 6}){sup 3/4}, where C{sub 6} is the strength of the interaction. The solidification curve at nonzero temperature is studied with the path-integral Monte Carlo approach and is compared with transitions in corresponding harmonic and classical crystals. Relaxation mechanisms are considered in relation to present experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

THE X-RAY POWER SPECTRAL DENSITY FUNCTION OF THE SEYFERT ACTIVE GALACTIC NUCLEUS NGC 7469

We present the broadband X-ray power spectral density (PSD) function of the X-ray-luminous Seyfert 1.2 NGC 7469, measured from Rossi X-ray Timing Explorer monitoring data and two XMM-Newton observations. We find significant evidence for a turnover in the 2-10 keV PSD at a temporal frequency of 2.0{sup +3.0}{sub -0.8} x 10{sup -6} Hz or 1.0{sup +3.0}{sub -0.6} x 10{sup -6} Hz, depending on the exact form of the break (sharply broken or slowly bending power law, respectively). The 'surrogate' Monte Carlo method of Press et al. was used to map out the probability distributions of PSD model parameters and obtain reliable uncertainties (68% confidence limits quoted here). The corresponding break timescale of 5.8 {+-} 3.5 days or 11.6{sup +17.5}{sub -8.7} days, respectively, is consistent with the empirical relation between PSD break timescale, black hole mass, and bolometric luminosity of McHardy et al. Compared to the 2-10 keV PSD, the 10-20 keV PSD has a much flatter shape at high temporal frequencies, and no PSD break is significantly detected, suggesting an energy-dependent evolution not unlike that exhibited by several Galactic black hole systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Delivery validation of an automated modulated electron radiotherapy plan

Purpose: Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In this work, the authors investigate the accuracy and efficiency of an end-to-end MERT plan and automated delivery method. Methods: Treatment planning was initiated on a previously treated whole breast irradiation case including an electron boost. All dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification, using an automated motorized tertiary collimator. Results: The automated delivery, which covered four electron energies, 196 subfields, and 6183 total MU was completed in 25.8 min, including 6.2 min of beam-on time. The remainder of the delivery time was spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. Comparison of the planned and delivered film dose gave 3%/3mm gamma pass rates of 62.1%, 99.8%, 97.8%, 98.3%, and 98.7% for the 9, 12, 16, and 20 MeV, and combined energy deliveries, respectively. Delivery was also performed with a MapCHECK device and resulted in 3%/3 mm gamma pass rates of 88.8%, 86.1%, 89.4%, and 94.8% for the 9, 12, 16, and 20 MeV energies, respectively. Conclusions: Results of the authors’ study showed that an accurate delivery utilizing an add-on tertiary electron collimator is possible using Monte Carlo calculated plans and inverse optimization, which brings MERT closer to becoming a viable option for physicians in treating superficial malignancies.

60 APPLIED LIFE SCIENCES↗

Bethe Approximation for a Two-Dimensional Spin-Pseudospin System

We have treated a two-dimensional spin-pseudospin model, which generalizes a diluted antiferromagnetic Ising model with charged nonmagnetic impurities in the case of two types of charges. The analytical results in the Bethe approximation are compared with the results of numerical simulation using the classical Monte Carlo method for various parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strategic Design and Optimization of Inorganic Sorbents for Cesium, Strontium and Actinides

The primary objective of the Notre Dame component of the project was computational in nature. The goal was to provide a design tool for the synthesis of optimized sorbents for the removal of cesium, strontium and actinides from nuclear waste solutions. Molecular modeling enables us to observe and better understand the molecular level interactions that govern the selectivity of specific radionuclides in a particular sorbent. The research focused on the development and validation of a suitable and transferable model for all the cations and ion exchangers of interest, nd then subsequent simulations which determined the siting and mobility of water and cations. Speciic accomplishments include: (1) improving existing intermolecular force fields to accurately model the sorbents of interest; (2) utilizing energy-minimizations and molecular dynamics simulations for structural prediction of CST and niobium-substituted CST materials; (3) determining Na+/water positions in polyoxoniobate materials using molecular dynamics simulations; and (4) developing Hybrid Monte Carlo methods for improved structural prediction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electromechanical Mode On-line Estimation using Regularized Robust RLS Methods

This paper proposes a regularized robust recursive least squares (R3LS) method for on-line estimation of power-system electromechanical modes based on synchronized phasor measurement unit (PMU) data. The proposed method utilizes an autoregressive moving average exogenous (ARMAX) model to account for typical measurement data, which includes low-level pseudo-random probing, ambient, and ringdown data. A robust objective function is utilized to reduce the negative influence from non-typical data, which include outliers and missing data. A dy-namic regularization method is introduced to help include a priori knowledge about the system and reduce the influence of under-determined problems. Based on a 17-machine simulation model, it is shown through the Monte-Carlo method that the proposed R3LS method can estimate and track electromechanical modes by effectively using combined typical and non-typical measurement data.

24 POWER TRANSMISSION AND DISTRIBUTION↗