Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Predicting Overall Survival After Stereotactic Ablative Radiation Therapy in Early-Stage Lung Cancer: Development and External Validation of the Amsterdam Prognostic Model

Purpose: A prognostic model for 5-year overall survival (OS), consisting of recursive partitioning analysis (RPA) and a nomogram, was developed for patients with early-stage non-small cell lung cancer (ES-NSCLC) treated with stereotactic ablative radiation therapy (SABR). Methods and Materials: A primary dataset of 703 ES-NSCLC SABR patients was randomly divided into a training (67%) and an internal validation (33%) dataset. In the former group, 21 unique parameters consisting of patient, treatment, and tumor factors were entered into an RPA model to predict OS. Univariate and multivariate models were constructed for RPA-selected factors to evaluate their relationship with OS. A nomogram for OS was constructed based on factors significant in multivariate modeling and validated with calibration plots. Both the RPA and the nomogram were externally validated in independent surgical (n=193) and SABR (n=543) datasets. Results: RPA identified 2 distinct risk classes based on tumor diameter, age, World Health Organization performance status (PS) and Charlson comorbidity index. This RPA had moderate discrimination in SABR datasets (c-index range: 0.52-0.60) but was of limited value in the surgical validation cohort. The nomogram predicting OS included smoking history in addition to RPA-identified factors. In contrast to RPA, validation of the nomogram performed well in internal validation (r{sup 2}=0.97) and external SABR (r{sup 2}=0.79) and surgical cohorts (r{sup 2}=0.91). Conclusions: The Amsterdam prognostic model is the first externally validated prognostication tool for OS in ES-NSCLC treated with SABR available to individualize patient decision making. The nomogram retained strong performance across surgical and SABR external validation datasets. RPA performance was poor in surgical patients, suggesting that 2 different distinct patient populations are being treated with these 2 effective modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated Hypofractionated Intensity-Modulated Radiotherapy With Concurrent and Adjuvant Temozolomide for Patients With Glioblastoma Multiforme: A Safety and Efficacy Analysis

Purpose: Despite multimodality treatments, the outcome of patients with glioblastoma multiforme remains poor. In an attempt to improve results, we have begun a program of accelerated hypofractionated intensity-modulated radiotherapy (hypo-IMRT) with concomitant and adjuvant temozolomide (TMZ). Methods and Materials: Between March 2004 and June 2006, 35 unselected patients with glioblastoma multiforme were treated with hypo-IMRT. During a 4-week period, using a concomitant boost technique, a dose of 60 Gy and 40 Gy were delivered in 20 fractions prescribed to the periphery of the gross tumor volume and planning target volume, respectively. TMZ was administered according to the regimen of Stupp et al. Results: The median follow-up was 12.6 months. Of the 35 patients, 29 (82.8%) completed the combined modality treatment, and 25 (71.4%) received a median of four cycles of adjuvant TMZ. The median overall survival was 14.4 months, and the median disease-free survival was 7.7 months. The median survival time differed significantly between patients who underwent biopsy and those who underwent partial or total resection (7.1 vs. 16.1 months, p = 0.035). The median survival was also significantly different between patients with methylated vs. unmethylated 0-6-methylguanine-DNA methyltransferase promoters (14.4 vs. 8.7 months, p = 0.049). The pattern of failure was predominantly central, within 2 cm of the initial gross tumor volume. Grade 3-4 toxicity was limited to 1 patient with nausea and emesis during adjuvant TMZ administration. Conclusion: The results of our study have shown that hypo-IMRT with concomitant and adjuvant TMZ is well tolerated with a useful 2-week shortening of radiotherapy. Despite a high number of patients with poor prognostic features (74.3% recursive partitioning analysis class V or VI), the median survival was comparable to that after standard radiotherapy fractionation schedules plus TMZ.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional imaging of nanoscale materials by using coherent x-rays

X-ray crystallography is currently the primary methodology used to determine the 3D structure of materials and macromolecules. However, many nanostructures, disordered materials, biomaterials, hybrid materials and biological specimens are noncrystalline and, hence, their structures are not accessible by X-ray crystallography. Probing these structures therefore requires the employment of different approaches. A very promising technique currently under rapid development is X-ray diffraction microscopy (or lensless imaging), in which the coherent X-ray diffraction pattern of a noncrystalline specimen is measured and then directly phased to obtain a high-resolution image. Through the DOE support over the past three years, we have applied X-ray diffraction microscopy to quantitative imaging of GaN quantum dot particles, and revealed the internal GaN-Ga2O3 core shell structure in three dimensions. By exploiting the abrupt change in the scattering cross-section near electronic resonances, we carried out the first experimental demonstration of resonant X-ray diffraction microscopy for element specific imaging. We performed nondestructive and quantitative imaging of buried Bi structures inside a Si crystal by directly phasing coherent X-ray diffraction patterns acquired below and above the Bi M5 edge. We have also applied X-ray diffraction microscopy to nondestructive imaging of mineral crystals inside biological composite materials - intramuscular fish bone - at the nanometer scale resolution. We identified mineral crystals in collagen fibrils at different stages of mineralization and proposed a dynamic mechanism to account for the nucleation and growth of mineral crystals in the collagen matrix. In addition, we have also discovered a novel 3D imaging modality, denoted ankylography, which allows for complete 3D structure determination without the necessity of sample titling or scanning. We showed that when the diffraction pattern of a finite object is sampled at a sufficiently fine scale on the Ewald sphere, the 3D structure of the object is determined by the 2D spherical pattern. We confirmed the theoretical analysis by performing 3D numerical reconstructions of a sodium silicate glass structure at 2 A resolution from a 2D spherical diffraction pattern alone. As X-ray free electron lasers are under rapid development worldwide, ankylography may open up a new horizon to obtain the 3D structure of a non-crystalline specimen from a single pulse and allow time-resolved 3D structure determination of disordered materials.

36 MATERIALS SCIENCE↗

Real-time Object Bounding in LiDAR Data With Computer Vision

The Multimodal Measurement System is a roadside radiation measurement testbed used to detect radiation sources in passing vehicles. It works by combining sensor signals from various modalities to produce a thorough scan of the source. A LiDAR sensor is used to measure the dimensions of the vehicle and provide a velocity estimate. However, the current LiDAR setup uses propriety software for which the source code is unavailable and cannot be updated to improve performance. Therefore, it is imperative to the accuracy of the analysis to create a custom vehicle detection that can return the dimensions and velocity of passing vehicles in real time. This new custom detection is written in C++ using the PointCloud Library, which keeps it lightweight. It also utilizes Docker and the Robot Operating System, which allows the versatility of running both on a small computer or the Lawrence Livermore National Laboratory cluster while utilizing different models of LiDAR sensors. The custom detection outperforms the current detection model, which increases the accuracy of radiation source detection.

97 MATHEMATICS AND COMPUTING↗

Comment on 'Modal expansion approach to optical-frequency-comb generation with monolithic whispering-gallery-mode resonators'

Authors of a recent paper [Y. K. Chembo and N. Yu, Phys. Rev. A 82, 033801 (2010)] claimed to have developed a general framework for description of nonlinear effects in whispering-gallery-mode resonators with particular focus on optical-frequency-comb generation. In this Comment we demonstrate that the author's approach contains mathematical errors affecting some of the results of the paper. Fortunately, analysis of this phenomenon using a mathematically more rigorous approach shows that the main conclusions of that paper remain intact.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RadMAP: The Radiological Multi-sensor Analysis Platform

The variability of gamma-ray and neutron background during the operation of a mobile detector system greatly limits the ability of the system to detect weak radiological and nuclear threats. The natural radiation background measured by a mobile detector system is the result of many factors, including the radioactivity of nearby materials, the geometric configuration of those materials and the system, the presence of absorbing materials, and atmospheric conditions. Background variations tend to be highly non-Poissonian, making it difficult to set robust detection thresholds using knowledge of the mean background rate alone. The Radiological Multi-sensor Analysis Platform (RadMAP) system is designed to allow the systematic study of natural radiological background variations and to serve as a development platform for emerging concepts in mobile radiation detection and imaging. To do this, RadMAP has been used to acquire extensive, systematic background measurements and correlated contextual data that can be used to test algorithms and detector modalities at low false alarm rates. By combining gamma-ray and neutron detector systems with data from contextual sensors, the system enables the fusion of data from multiple sensors into novel data products. The data are curated in a common format that allows for rapid querying across all sensors, creating detailed multi-sensor datasets that are used to study correlations between radiological and contextual data, and develop and test novel techniques in mobile detection and imaging. Here we will describe the instruments that comprise the RadMAP system, the effort to curate and provide access to multi-sensor data, and some initial results on the fusion of contextual and radiological data.

47 OTHER INSTRUMENTATION↗

Modal expansion approach to optical-frequency-comb generation with monolithic whispering-gallery-mode resonators

We describe a general framework based on modal expansion for the study of optical-frequency combs generated with monolithic whispering-gallery-mode resonators. We obtain a set of time-domain rate equations describing the dynamics of each mode as a function of the main characteristics of the cavity, namely, Kerr nonlinearity, absorption, coupling losses, and cavity dispersion (geometrical and material). A stability analysis of the various side modes is performed, which finds analytically the threshold power needed for comb generation. We show that the various whispering gallery modes are excited in a nontrivial way, strongly dependent on the value of the overall cavity dispersion. We demonstrate that the combs are not simply generated through a direct transfer of energy from the pumped mode to all their neighbors but rather through complex intermediate interactions. Anomalous cavity dispersion is also demonstrated to be critical for these cascading processes, and comb generation is thereby unambiguously linked to modulational instability. This theory accurately describes the emergence of spectral modulation and free spectral-range tunability in the comb. It also enables a clear understanding of the various phenomena responsible for the spectral span limitation. Our theoretical predictions are in excellent agreement with the numerical simulations, and they successfully explain the internal mechanisms responsible for the generation of hundreds of Kerr modes in monolithic whispering-gallery-mode resonators.

43 PARTICLE ACCELERATORS↗

Multi-sensor anomalous change detection in remote sensing imagery

Combining multiple satellite remote sensing sources provides a far richer, more frequent view of the earth than that of any single source; the challenge is in distilling these petabytes of heterogeneous sensor imagery into meaningful characterizations of the imaged areas. Meeting this challenge requires effective algorithms for combining multi-modal imagery over time to identify subtle but real changes among the intrinsic data variation. Here, we implement a joint-distribution framework for multi-sensor anomalous change detection (MSACD) that can effectively account for these differences in modality, and does not require any signal resampling of the pixel measurements. This flexibility enables the use of satellite imagery from different sensor platforms and modalities. We use multi-year construction of the SoFi Stadium in California as our testbed, and exploit synthetic aperture radar imagery from Sentinel-1 and multispectral imagery from both Sentinel-2 and Landsat 8. We show results for MSACD using real imagery with implanted, measurable changes, as well as real imagery with real, observable changes, including scaling our analysis over multiple years.

47 OTHER INSTRUMENTATION↗

SU-F-19A-11: Retrospective Evaluation of Thermal Coverage by Thermobrachytherapy Seed Arrangements of Clinical LDR Prostate Implants

Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains one of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been successfully evaluated for its ability to provide sufficient hyperthermia in clinically-realistic implants. This work was partially supported by the National Institutes of Health (NIH) STTR Grant No. R41 CA153631-01A1.

60 APPLIED LIFE SCIENCES↗

Salvage HDR Brachytherapy for Recurrent Prostate Cancer After Previous Definitive Radiation Therapy: 5-Year Outcomes

Purpose: Evaluate efficacy and toxicity of salvage high-dose-rate brachytherapy (HDRB) for locally recurrent prostate cancer after definitive radiation therapy (RT). Methods and Materials: We retrospectively analyzed 52 consecutively accrued patients undergoing salvage HDRB between 1998 and 2009 for locally recurrent prostate cancer after previous definitive RT. After pathologic confirmation of locally recurrent disease, patients received 36 Gy in 6 fractions. Twenty-four patients received neoadjuvant hormonal therapy before salvage, and no patients received adjuvant hormonal therapy. Determination of biochemical failure after salvage HDRB was based on the Phoenix definition. Overall survival (OS) and bF distributions were calculated using the Kaplan-Meier method. Univariate analyses were performed to identify predictors of biochemical control. Acute and late genitourinary (GU) and gastrointestinal (GI) toxicities, based on Common Terminology Criteria for Adverse Events (version 4), were documented. Results: Median follow-up after salvage HDRB was 59.6 months. The 5-year OS estimate was 92% (95% confidence interval [CI]: 80%-97%) with median survival not yet reached. Five-year biochemical control after salvage was 51% (95% CI: 34%-66%). Median PSA nadir postsalvage was 0.1 (range: 0-7.2) reached at a median of 10.2 months after completing HDRB. As for complications, acute and late grade 3 GU toxicities were observed in only 2% and 2%, respectively. No grade 2 or higher acute GI events and 4% grade 2 GI late events were observed. On univariate analysis, disease-free interval after initial definitive RT (P=.07), percent of positive cores at the time of diagnosis (P=.08), interval from first recurrence to salvage HDRB (P=.09), and pre-HDRB prostate-specific antigen (P=.07) were each of borderline significance in predicting biochemical control after salvage HDRB. Conclusions: Prostate HDRB is an effective salvage modality with relatively few long-term toxicities. We provide potential predictors of biochemical control for prostate salvage HDRB.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Second Cancers According to Radiation Therapy Technique and Modality in Prostate Cancer Survivors

Purpose: Radiation therapy (RT) techniques for prostate cancer are evolving rapidly, but the impact of these changes on risk of second cancers, which are an uncommon but serious consequence of RT, are uncertain. We conducted a comprehensive assessment of risks of second cancer according to RT technique (>10 MV vs ≤10 MV and 3-dimensional [3D] vs 2D RT) and modality (external beam RT, brachytherapy, and combined modes) in a large cohort of prostate cancer patients. Methods and Materials: The cohort was constructed using the Surveillance Epidemiology and End Results-Medicare database. We included cases of prostate cancer diagnosed in patients 66 to 84 years of age from 1992 to 2004 and followed through 2009. We used Poisson regression analysis to compare rates of second cancer across RT groups with adjustment for age, follow-up, chemotherapy, hormone therapy, and comorbidities. Analyses of second solid cancers were based on the number of 5-year survivors (n=38,733), and analyses of leukemia were based on number of 2-year survivors (n=52,515) to account for the minimum latency period for radiation-related cancer. Results: During an average of 4.4 years' follow-up among 5-year prostate cancer survivors (2DRT = 5.5 years; 3DRT = 3.9 years; and brachytherapy = 2.7 years), 2933 second solid cancers were diagnosed. There were no significant differences in second solid cancer rates overall between 3DRT and 2DRT patients (relative risk [RR] = 1.00, 95% confidence interval [CI]: 0.91-1.09), but second rectal cancer rates were significantly lower after 3DRT (RR = 0.59, 95% CI: 0.40-0.88). Rates of second solid cancers for higher- and lower-energy RT were similar overall (RR = 0.97, 95% CI: 0.89-1.06), as were rates for site-specific cancers. There were significant reductions in colon cancer and leukemia rates in the first decade after brachytherapy compared to those after external beam RT. Conclusions: Advanced treatment planning may have reduced rectal cancer risks in prostate cancer survivors by approximately 3 cases per 1000 after 15 years. Despite concerns about the neutron doses, we did not find evidence that higher energy therapy was associated with increased second cancer risks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Bulk and Thin Film Model Samples Intended for Investigating the Strain Sensitivity of Niobium-Tin

Bulk samples and thin films were fabricated and characterized to determine their suitability for studying the effect of composition and morphology on strain sensitivity. Heat capacity and resistivity data are used to determine the critical temperature distribution. It is found that all bulk samples contain stoichiometric Nb{sub 3}Sn regardless of their nominal Nb to Sn ratio. Furthermore, in bulk samples with Cu additions, a bi-modal distribution of stoichiometric and off-stoichiometric Nb-Sn is found. Thus the nominally off-stoichiometric bulk samples require additional homogenization steps to yield homogeneous off-stoichiometric samples. A binary magnetron-sputtered thin film has the intended off-stoichiometric Nb-Sn phase with a mid-point critical temperature of 16.3 K. This type of sample is a suitable candidate for investigating the strain sensitivity of A15 Nb{sub 1-{beta}}Sn{sub {beta}}, with 0.18 < {beta} < 0.25. The strain sensitivity of Nb-Sn as a function of composition and morphology is important for an in-depth understanding of the strain sensitivity of composite Nb{sub 3}Sn wires.

43 PARTICLE ACCELERATORS↗

SU-E-J-275: Review - Computerized PET/CT Image Analysis in the Evaluation of Tumor Response to Therapy

Purpose: To review the literature in using computerized PET/CT image analysis for the evaluation of tumor response to therapy. Methods: We reviewed and summarized more than 100 papers that used computerized image analysis techniques for the evaluation of tumor response with PET/CT. This review mainly covered four aspects: image registration, tumor segmentation, image feature extraction, and response evaluation. Results: Although rigid image registration is straightforward, it has been shown to achieve good alignment between baseline and evaluation scans. Deformable image registration has been shown to improve the alignment when complex deformable distortions occur due to tumor shrinkage, weight loss or gain, and motion. Many semi-automatic tumor segmentation methods have been developed on PET. A comparative study revealed benefits of high levels of user interaction with simultaneous visualization of CT images and PET gradients. On CT, semi-automatic methods have been developed for only tumors that show marked difference in CT attenuation between the tumor and the surrounding normal tissues. Quite a few multi-modality segmentation methods have been shown to improve accuracy compared to single-modality algorithms. Advanced PET image features considering spatial information, such as tumor volume, tumor shape, total glycolytic volume, histogram distance, and texture features have been found more informative than the traditional SUVmax for the prediction of tumor response. Advanced CT features, including volumetric, attenuation, morphologic, structure, and texture descriptors, have also been found advantage over the traditional RECIST and WHO criteria in certain tumor types. Predictive models based on machine learning technique have been constructed for correlating selected image features to response. These models showed improved performance compared to current methods using cutoff value of a single measurement for tumor response. Conclusion: This review showed that computerized PET/CT image analysis holds great potential to improve the accuracy in evaluation of tumor response. This work was supported in part by the National Cancer Institute Grant R01CA172638.

60 APPLIED LIFE SCIENCES↗

Comparative performance of multiview stereoscopic and mammographic display modalities for breast lesion detection

Purpose: Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations, including the superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion and the inability to derive volumetric information. It has been shown that stereomammography can overcome these deficiencies by showing that layers of normal tissue lay at different depths. If standard stereomammography (i.e., a single stereoscopic pair consisting of two projection images) can significantly improve lesion detection, how will multiview stereoscopy (MVS), where many projection images are used, compare to mammography? The aim of this study was to assess the relative performance of MVS compared to mammography for breast mass detection. Methods: The MVS image sets consisted of the 25 raw projection images acquired over an arc of approximately 45 deg. using a Siemens prototype breast tomosynthesis system. The mammograms were acquired using a commercial Siemens FFDM system. The raw data were taken from both of these systems for 27 cases and realistic simulated mass lesions were added to duplicates of the 27 images at the same local contrast. The images with lesions (27 mammography and 27 MVS) and the images without lesions (27 mammography and 27 MVS) were then postprocessed to provide comparable and representative image appearance across the two modalities. All 108 image sets were shown to five full-time breast imaging radiologists in random order on a state-of-the-art stereoscopic display. The observers were asked to give a confidence rating for each image (0 for lesion definitely not present, 100 for lesion definitely present). The ratings were then compiled and processed using ROC and variance analysis. Results: The mean AUC for the five observers was 0.614{+-}0.055 for mammography and 0.778{+-}0.052 for multiview stereoscopy. The difference of 0.164{+-}0.065 was statistically significant with a p-value of 0.0148. Conclusions: The differences in the AUCs and the p-value suggest that multiview stereoscopy has a statistically significant advantage over mammography in the detection of simulated breast masses. This highlights the dominance of anatomical noise compared to quantum noise for breast mass detection. It also shows that significant lesion detection can be achieved with MVS without any of the artifacts associated with tomosynthesis.

60 APPLIED LIFE SCIENCES↗

From phase decomposition to evaporation: A multi-modal evaluation of thermally degraded model lightweight high-entropy alloy

Lightweight high-entropy alloys (LHEAs) have the potential to replace conventional lightweight materials due to their superior mechanical properties and thermal stability. However, the thermal degradation pattern of LHEAs from phase decomposition to evaporation is not clear. We develop a new Al-based dual phase (FCC + HCP) LHEA—AlTi 0.45 CuZn, and further investigate its thermal degradation behavior for potential high-temperature structural applications. Using multimodal advanced characterization techniques such as differential scanning calorimetry/thermogravimetric analysis, scanning/transmission electron microscopy, and synchrotron X-ray diffraction/pair distribution function (XRD/PDF), a sequence of thermal degradation events beyond the thermal phase stability limit—between 250 and 360 °C—is observed. These include phase decomposition at ~360 °C, Zn evaporation at ~750 °C, and LHEA melting at 880 °C which results in ~25% cumulative weight loss. The formation of Al-Ti phase off the AlTi 0.45 CuZn matrix is due to the largest negative mixing enthalpy for Al-Ti than other binary pairs. Similarly, Zn evaporation from AlTi 0.45 CuZn LHEA is due to its faster evaporation rate than other constituent elements. The high-resolution synchrotron XRD and PDF results support the aforementioned observations; in addition, they reveal local atomic arrangements, local strain, and sluggish grain growth in the LHEA. Among other LHEAs of close density range (5.55 ≤ ρ ≤ 5.85 g/cc), the investigated LHEA exhibits outstanding nano-indentation hardness values due to the coupled grain size effect and HCP phase strengthening of the FCC matrix. As the search for LHEAs for lightweight applications grows, this study shows the potential use of AlTi 0.45 CuZn LHEA for structural applications even at elevated temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characteristics of Movement-Induced Dose Reduction in Target Volume: A Comparison Between Photon and Proton Beam Treatment

We compared the main characteristics of movement-induced dose reduction during photon and proton beam treatment, based on an analysis of dose-volume histograms. To simulate target movement, a target contour was delineated in a scanned phantom and displaced by 3 to 20 mm. Although the dose reductions to the target in the 2 treatment systems were similar for transverse (perpendicular to beam direction) target motion, they were completely different for longitudinal (parallel to beam direction) target motion. While both modalities showed a relationship between the degree of target shift and the reduction in dose coverage, dose reduction showed a strong directional dependence in proton beam treatment. Clinical simulation of target movement for a prostate cancer patient showed that, although coverage and conformity indices for a 6-mm lateral movement of the prostate were reduced by 9% and 16%, respectively, for proton beam treatment, they were reduced by only 1% and 7%, respectively, for photon treatment. This difference was greater for a 15-mm target movement in the lateral direction, which lowered the coverage and conformity indices by 34% and 54%, respectively, for proton beam treatment, but changed little during photon treatment. In addition, we found that the equivalent uniform dose (EUD) and homogeneity index show similar characteristics during target movement. These results suggest that movement-induced dose reduction differs significantly between photon and proton beam treatment. Attention should be paid to the target margin in proton beam treatment due to the distinct characteristics of heavy ion beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Safety and Efficacy of Transarterial Radioembolization Combined with Chemoembolization for Bilobar Hepatocellular Carcinoma: A Single-Center Retrospective Study

BackgroundRadioembolization induced liver disease (REILD) is a possible sequela of transarterial radioembolization (TARE), particularly in cases of whole-liver treatment. To mitigate this problem, the safety and efficacy of combined transarterial chemoembolization (TACE) and TARE were evaluated for patients with bilobar hepatocellular carcinoma (HCC).Materials and MethodsNineteen patients (mean age 60 years; range 27–82 years) treated for HCC between June 2012 and September 2014 were included in the analysis. Each patient was treated with combined TARE and TACE for bilobar HCC, with or without portal vein thrombosis. The hepatic lobe with large HCC was treated with TARE, and the other lobe with small HCC(s) was treated with TACE. Laboratory and clinical data were investigated to determine REILD occurrence. Survival data were analyzed to compare the treatment efficacy of alternative treatment modalities, including TACE and sequential TARE.ResultsAll patients underwent TARE for a dominant tumor in one lobe and TACE for small nodule(s) in the other lobe of the liver. The mean yttrium-90 microspheres used in TARE were 2.8 GBq (range; 1.0-3.5 GBq), and the mean doses of doxorubicin and iodized oil were 24.5 mg and 5.2 mL, respectively, for TACE. No statistical differences were noted between laboratory data measured before and after treatment, and no procedure-related major clinical complications occurred. The median time-to-progression of patients was 10.0 months, and the median overall survival was 27.3 months.ConclusionCombined radioembolization and chemoembolization appears to be a safe and effective treatment modality for bilobar HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of concrete microstructure using complementarity of X-ray and neutron tomography

The concrete microstructure was successfully reconstructed using the complementarity of X-ray and neutron computed tomography (CT). Neither tomogram alone was found to be suitable to properly describe the microstructure of concrete under this study. However, by merging the information revealed by the two modalities, and using image segmentation, noise reduction, and image registration techniques we reconstruct the concrete microstructure. Void, aggregate, and cement paste phases are successfully captured down to the images' spatial resolution, even though the aggregate consists of multiple minerals. The coarse-aggregate volume fraction of the reconstructed microstructure was similar to that of the mixing proportions. Furthermore, image-based finite element analysis is performed to demonstrate the effects of microstructure on stress concentration and strain localization.

36 MATERIALS SCIENCE↗