Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

The Mini Astrophysical MeV Background Observatory (MAMBO) CubeSat mission

The origin of the cosmic diffuse gamma-ray (CDG) background in the 0.3 – 30 MeV energy range is a mystery that has persisted for over 40 years. The Mini Astrophysical MeV Background Observatory (MAMBO) is a CubeSat mission concept motivated by the fact that, since the MeV CDG is relatively bright, only a small detector is required to make highquality measurements of it. Indeed, the sensitivity of space-based gamma-ray instruments to the CDG is limited not by size, but by the locally generated instrumental background produced by interactions of energetic particles in spacecraft materials. Comparatively tiny CubeSat platforms provide a uniquely quiet environment relative to previous gamma-ray science missions. The MAMBO mission will provide the best measurements ever made of the MeV CDG spectrum and angular distribution, utilizing two key innovations: 1) low instrumental background on a 12U CubeSat platform; and 2) an innovative shielded spectrometer design that simultaneously measures signal and background. We describe the MAMBO instrument and mission concept in detail, including simulations and laboratory measurements demonstrating the key measurement concept.

Astronomy and astrophysics↗

The integrated miniaturized electrostatic analyzer: A space plasma environment sensor

The integrated Miniaturized Electrostatic Analyzer (iMESA) was a satellite-based ionospheric sensor that operated on NASA’s Space Test Program Satellite (STPSat-3) from December 2013 to July 2019. The instrument’s scientific objective was to (1) measure the plasma density in low Earth orbit, (2) measure the plasma temperature in low Earth orbit, and (3) quantify the spacecraft potential with respect to the ambient plasma potential in the ionosphere. iMESA sampled the ionosphere every 10 s by measuring the ion current density through the ESA as a result of the motion of the spacecraft through the plasma. Current density spectra were transmitted to the ground where they were post-processed into ion density spectra and then analyzed numerically to determine the ion density, ion temperature, and spacecraft potential. This article discusses the instrument design and simulation, the determination of a geometric factor, and data processing procedures and evaluates the final data product with regard to the mission success criteria. Here, the ion density and ion temperature captured by the iMESA instrument are on the same order and range as the values predicted in the literature. The spacecraft potential was also quantified. The conclusion after the evaluation of the instrument’s data product is that the scientific mission is successful on all three points.

47 OTHER INSTRUMENTATION↗

SAIL-Isotopologue (SAIL-iso) Field Campaign Report

The SAIL-iso project took place from November 19, 2022 to June 3, 2023 as part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) project at the main project site in Gothic, Colorado. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in a remote mountainous watershed. Water vapor isotopologue and humidity measurements were determined using a Los Gatos Research Triple Water Vapor Isotope Analyzer (TWVIA). The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through Teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. Multiple sources of uncertainty are introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) Vienna Standard Mean Ocean Water – Standard Light Antarctic Precipitation (VSMOW-SLAP) calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ 18 O.

54 ENVIRONMENTAL SCIENCES↗

The Illumination of Thunderclouds by Lightning: 4. Volumetric Thunderstorm Imagery

Optical instruments such as the Geostationary Lightning Mapper (GLM) detect lightning based on transient changes in cloud illumination. The horizontal location of lightning is determined from the coordinates of the pixels on the imaging array illuminated during the flash. However, the vertical position of the lightning pulses (approximated by GLM “groups”) below the cloud top cannot be routinely measured from a single space-based instrument. In our prior work, we have developed a machine learning algorithm that can infer optical source altitude for a given pulse based on how the optical energy is distributed across the group footprint and the local Advanced Baseline Imager Cloud-Top Height (CTH). In this fourth part of our thundercloud illumination study, we leverage these source altitudes to generate volumetric GLM imagery of a Colombia thunderstorm. We find that 3D versions of the current GLM meteorological imagery products (that describe thunderstorm kinematics) and thundercloud imagery products (that depict how the flashes appear from space) provide additional insights into lightning activity in the thunderstorm that are lost in the vertical integration used to generate the current 2D GLM gridded products. This new volumetric imaging capability provides a more comprehensive picture of where lightning occurs in the storm, how its physical characteristics vary across three-dimensional space, and how its optical emissions interact with surrounding the cloud medium.

54 ENVIRONMENTAL SCIENCES↗

A digital twin based on OpenFAST linearizations for real-time load and fatigue estimation of land-based turbines

Monitoring a wind turbine requires intensive instrumentation, which would be too cost-prohibitive to deploy to an entire wind plant. This work presents a technique that uses readily available measurements to estimate signals that would otherwise require additional instrumentation. This study presents a digital twin concept with a focus on estimating wind speed, thrust, torque, tower-top position, and loads in the tower using supervisory control and data acquisition (SCADA) measurements. The model combines a linear state-space model obtained using OpenFAST linearizations, a wind speed estimator, and a Kalman filter algorithm that integrates measurements with the state model to perform state estimations. The measurements are: top acceleration, generator torque, pitch, and rotational speed. The article extends previous work that derived the linear state-space model using a different method. The new implementation, based on OpenFAST linearization capability, allows for a systematic extension of the method to more states, inputs, outputs, and to the offshore environment. Results from the two methods are compared, and the validation is made with additional measurements using the GE 1.5-MW turbine located at the National Renewable Energy Laboratory test site. Real-time damage equivalent loads of the tower bottom moment are estimated with an average accuracy of approximately 10%. Overall, the results from this proof of concept are encouraging, and further application of the model will be considered.

17 WIND ENERGY↗

CROCUS Air Quality Dataset from the University of Illinois Chicago (UIC), July 2024

This dataset was collected by the measurement system in the Atmosphere, Climate, and Ecosystems (ACE) Lab at the University of Illinois Chicago (UIC) from July 12 to July 31, 2024, as part of the Community Research on Climate and Urban Science (CROCUS) Urban Integrated Field Laboratory (UIFL) project, led by Argonne National Laboratory.To enhance understanding of urban air quality dynamics in Chicago, and as part of the CROCUS 2024 Urban Canyon Intensive Observation Period (IOP), several instruments were set up to provide continuous measurements of air quality parameters in Chicago during July 2024. These measurements cover both aerosols and gas-phase species. It focuses on particle size distribution (2.5–478 nm) measured by two Scanning Mobility Particle Sizers (SMPS) at a 4-min resolution, total particle number concentrations at a 1-s resolution, and chemical composition from a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (AMS) at a 1-min resolution. Key gas-phase species, including NO, NO₂, SO₂, and O₃, are measured at a 1-min resolution, along with high-resolution NO and dimethyl sulfide (DMS) data from a Chemical Ionization Mass Spectrometer (CIMS). Volatile organic compound (VOC) data for toluene, isoprene, and benzene are provided by a GC-PID with a time resolution of 25 minutes.The data are formatted as NetCDF (.nc) files, making them easily accessible using common software such as MATLAB, R, and Python. Each parameter is stored in an individual dataset, which includes detailed instrument information in the header, as well as the corresponding sample start time and concentration/distribution data for each sample.

54 ENVIRONMENTAL SCIENCES↗

Preface to the Proceedings of the 23rd Topical Conference on High-Temperature Plasma Diagnostics

Measurements of phenomena advance our understanding of the physical universe. As our understanding grows, more precise measurements are required, as are measurements of new quantities. Diagnosis of a plasma requires developing new instruments, also called diagnostics, as well as new ways to analyze, interpret, synthesize, and correlate their measurements. Further, as computing power increases and multi-physics codes improve their accuracy, more precise measurements are needed to guide future code developments and to validate predictions of these simulation codes. The Topical Conference on High-Temperature Plasma Diagnostics is focused on presenting and documenting the most recent advances in these instrumentation areas for plasmas. The 23rd occurrence of this biennial conference took place on December 14–17, 2020, and was hosted by Los Alamos National Laboratory. Originally scheduled for June 2020 in Santa Fe, New Mexico, the conference was postponed and then held virtually due to the global COVID-19 pandemic. Conference times were adjusted and presentations were scheduled to meet the needs of attendees in Europe, the USA, and Asia.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature Measurements in Hypersonic Wind Tunnels via Femtosecond Coherent Anti-Stokes Raman Scattering

A femtosecond coherent anti-Stokes Raman scattering (fs CARS) instrument is developed to perform gas-phase thermometry in cold-flow hypersonic wind tunnels. Measurements are reported for Mach 8 and 14 pure-nitrogen flows. The fs CARS instrument includes a 100 fs pump/Stokes pulse and a spectrally narrow probe pulse from a second harmonic bandwidth compressor. Important experimental considerations such as limits on the pump/Stokes pulse energy are discussed. The fs CARS focusing and collimating optics are mounted on a two-axis translation stage system to scan the measurement location during a 30 second wind tunnel run. Single-laser-shot rotational CARS spectra are recorded at the laser repetition rate of 1 kHz in the wind tunnel freestream and near simple cone models. Spectral fitting is used to determine quantitative gas temperatures. Freestream temperatures at Mach 8 and 14 spanned ranges of 40–75 and 35–50 K, respectively, depending on tunnel operating conditions. Temperature variations across the central 100 mm span of the wind tunnel were quantified. Measured temperature jumps across conical bow shocks from various models varied by less than 1% from predicted values. Hypersonic boundary layer measurements were demonstrated. In conclusion, these measurements illustrate the utility and robustness of this instrument for the study of complex fluid flow phenomena in challenging ground test facilities.

Aerodynamics↗

Trigonometric Parallaxes of Two T Dwarfs With Keck and ShaneAO Astrometry

We present trigonometric parallax and proper motion measurements for two T-type brown dwarfs. We derive our measurements from infrared laser guide star adaptive optics observations spanning five years from the ShaneAO/SHARCS and NIRC2/medium-cam instruments on the Shane and Keck telescopes, respectively. To improve our astrometric precision, we measure and apply a distortion correction to our fields for both instruments. We also transform the Keck and ShaneAO astrometric reference frames onto the ICRS using five-parameter parallax and proper motion solutions for background reference stars from Gaia DR2. Fitting for parallax and proper motion, we measure parallaxes of 73.5 ± 9.2 mas and 70.1 ± 6.7 mas for WISEJ19010703+47181688 (WISE1901) and WISEJ21543294+59421370 (WISE2154), respectively. We utilize Monte Carlo methods to estimate the error in our sparse field methods, taking into account overfitting and differential atmospheric refraction. Comparing to previous measurements in the literature, all of our parallax and proper motion values fall within 2σ of the published measurements, and 4 of 6 measurements are within 1σ. These data are among the first parallax measurements of these T dwarfs and serve as precise measurements for calibrating stellar formation models. These two objects are the first results of an ongoing survey of T dwarfs with Keck/NIRC2 and the Shane Adaptive Optics system at Lick Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

CROCUS High-Frequency Measurements of CO₂, H₂O, Wind, and Temperature at University of Illinois Chicago

As of April 9, 2026: this dataset is currently being versioned to include data up to March 31, 2026. Once the versioning process is complete, new data files will be available for access. The dataset metadata will also be updated to reflect the data availability of the new data being versioned. Raw atmospheric measurements collected at the University of Illinois Chicago (UIC) as part of the Community Research on Climate and Urban Science (CROCUS) project. The data includes high-frequency measurements of carbon dioxide (CO₂) concentration, water vapor (H₂O) concentration, wind speed (U, V, W components), temperature, and atmospheric pressure. These raw data are recorded by the LI-7500DS Open Path CO₂/H₂O Analyzer and a sonic anemometer at a 10 Hz acquisition frequency, providing the necessary inputs for calculating fluxes of CO₂, H₂O, heat, and momentum. In addition to gas concentration measurements, the dataset includes diagnostic information from the instruments, including absorptance, sample and reference signals, and diagnostic values. The data were collected to study urban atmospheric conditions and contribute to flux calculations for urban climate research. These measurements form the basis for calculating 30-minute average fluxes of key atmospheric variables using the eddy covariance method. This dataset provides critical raw input data for researchers interested in atmospheric fluxes, urban air quality, and the interaction between the urban environment and atmospheric processes. The data is part of the U.S. Department of Energy’s Biological and Environmental Research (BER) program, under the CROCUS Urban Integrated Field Laboratory (UIFL) project.

54 ENVIRONMENTAL SCIENCES↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

EPCAPE-PT-LANL Measurements: Photoacoustic Extinctometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Photoacoustic Extinctiometer at 870 nm (Droplet Measurement Technology) Header: - AbsorptionNoise_870nm[1/Mm]: Noise level associated with the absorption measurement at 870 nm, expressed in inverse megameters (Mm⁻¹). - Absorption_870nm[1/Mm]: Absorption coefficient of aerosols measured at 870 nm, expressed in inverse megameters (Mm⁻¹). - Extinction_870nm[1/Mm]: Extinction coefficient of aerosols measured at 870 nm, expressing the sum of scattering and absorption by aerosols, in inverse megameters (Mm⁻¹). - Scattering_870nm[1/Mm]: Scattering coefficient of aerosols measured at 870 nm, expressed in inverse megameters (Mm⁻¹). - BackgroundAbsorption_870nm[1/Mm]: Background absorption measurement at 870 nm, used to correct the primary absorption data, expressed in inverse megameters (Mm⁻¹). - BackgroundScattering_870nm[1/Mm]: Background scattering measurement at 870 nm, used to correct the primary scattering data, expressed in inverse megameters (Mm⁻¹). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement

54 ENVIRONMENTAL SCIENCES↗

Time-Resolved Aerosol Filter Sampler Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (MCPC, 9403), a miniaturized optical particle counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook describes the principles and operations of the filter sampler.

54 ENVIRONMENTAL SCIENCES↗

Advanced Mixing Condensation Particle Counter (aMCPC) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (aMCPC, 9403), a miniaturized optical practical counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook focuses on the aMCPC, which measures the ultra-fast total aerosol particle number concentration at 180 ms response rate with a detection diameter (D 50 = 7 nm).

54 ENVIRONMENTAL SCIENCES↗

Miniaturized Optical Particle Counter (MOPC) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (MCPC, 9403), a miniaturized optical particle counter (mOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook focuses on the mOPC, which measures the aerosol particle size distribution between 0.19 and 3 μm.

54 ENVIRONMENTAL SCIENCES↗

First ARM Mobile Facility (AMF1) Aerosol Observing System (AOS01) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Mobile Aerosol Observing System – Aerosols (MAOS-A), designated AOS01, entered service in March of 2012 at the Los Alamos National Laboratory for the Pajarito Aerosol Coupling to Ecosystems (PACE) field campaign. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floor are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Second ARM Mobile Facility (AMF2) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s second mobile facility (AMF2) Aerosol Observing System, designated AOS02, entered service in October of 2010 at Steamboat Springs, Colorado for the Storm Peak Laboratory Cloud Property Validation Experiment (StormVEx). The Aerosol Observing S ystem is meant to be a standalone, autonomous, aerosol sampling system. It requires only power, 208 or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Network of Modified Portable Optical Particle Spectrometers Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s portable optical particle spectrometer (POPS) network (Figure 1) provides an aerosol size distribution spectrum from 150 nm to 5 μm in 16 logarithmically spaced bins. The data emanating from this network of up to four matching POPS in weatherproof enclosures comprises one-minute averages of the aerosol size and number spectrum and the co-located temperature and relative humidity. The total particle concentration and sample flow rate are also provided. The sample stream is not dried before its measurement. Two size spectra are provided: the default size distribution corresponds to the calibration using polystyrene latex spheres (PSL), while the second size distribution corresponds to the calibration using size-selected dry ammonium sulfate aerosol. The principal scientific application of the data provided by the ARM POPS is to determine the aerosol size distribution across a region in three disparate locations – the size distribution is broadly relevant to studies of pollution and of conditions in the boundary layer. A high particle concentration can be an indicator of unhealthy levels of pollution; the dispersion of particles in the atmosphere is a predictor of long-range visibility; and particles serve as collectors of condensing gases including water vapor, and thus are a factor in the formation and properties of fogs and clouds, and in the initiation of precipitation.

54 ENVIRONMENTAL SCIENCES↗