Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗

Turbo FRMAC Implementation of IAEA Radiological Assessment Methodologies for Nuclear and Radiological Emergencies: Ingestion Pathway and Skin and Thyroid Monitoring

This report documents the findings of an assessment of the Turbo FRMAC© software’s ability to implement International Atomic Energy Agency (IAEA) guidance for calculating operational intervention levels (OIL) for nuclear and radiological emergencies. This assessment is a continuation of previous work that considered IAEA OIL1 and OIL2 for evacuation and relocation protective actions. The IAEA OIL and U.S. Federal Radiological Monitoring and Assessment Center (FRMAC) derived response and intervention level methodologies were compared for ingestion and skin and thyroid monitoring pathways. This comparison revealed significant differences in IAEA versus FRMAC handling of these pathways, which precluded an assessment of Turbo FRMAC’s ability to implement the IAEA approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Robust Event Diagnostics Platform: Integrating Tensor Analytics and Machine Learning into Real-time Grid Monitoring

The objective of this project is to develop a robust event diagnostics (RED) platform by integrating state-of-the-art tensor analytics and machine learning into real-time grid monitoring. The proposed platform can effectively analyze and discover the information hiding within the provided PMU data for effective real-time grid monitoring. The proposed RED platform provides a set of robust diagnostics tools for grid operation and management, including 1) data quality assessment, 2) data completion, 3) event detection, and 4) robust event classification. All the functionalities of the RED platform can help the operator to make informed decisions and respond in a timely manner. The developed RED platform will serve as an innovative advisory tool to reliably identify key events and discover new insights about the events and grid characteristics in the PMU data, and contribute to the efficient, safe, reliable operation and design of the nation’s electric system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strain Gauge Diagnostic Development for use in Vessel Health Monitoring for Hydro-shots

Six-foot vessels are a crucial component to protecting high fidelity equipment at DARHT. Analysis shows these vessels have a limited life span (~10 shots) due to fatigue, ratcheting, and damage accumulation. Vessel health monitoring and diagnostics can help inform decision on a vessel’s fitness for service. Strain gauges are an easy and effective sensor for use in vessel health monitoring. In early March, J-2 executed a qualification shot, uniform blast loading with minimal fragments, with bi-axial strain gauges fielded at four locations around vessel. Several damage features were extracted from the data, and frequency content helps to validate computer modelling of the vessel response. Permanent plastic strain at each location was significant with location one having the most strain at the end state, with 230 micro-strain. However, residual pressure in the vessel could be a major factor in this strain. PEEQ is a measure of total plastic equivalent strain accumulation. The equivalent strain at location one exceeded the plastic strain limit four times and accumulated the most PEEQ with 2036 micro-strain. As expected, this qualification shot did contribute to damage in the vessel, and should be considered in its fitness for service, but not critical enough to pull it from service. Frequency content also gave valuable information on the modal response of the vessel and contributes to the understanding of how the vessel responds to the initial blast load with an expected lower frequency membrane/breathing mode and transitioning to higher frequency bending modes in the vessel wall.

42 ENGINEERING↗

Improving Coal-Fired Plant Performance Through Integrated Predictive and Condition-Based Monitoring Tools

The project demonstrated the ability to improve boiler performance and reliability through the integrated use of condition-based monitoring (CBM) and predictions of the impacts of coal quality on boiler operations at a full-scale coal-fired power plant. The advanced tool developed actively monitors and manages coal quality and overall boiler conditions that maximizes availability and maintains generating capacity while reducing cost. The tool is used to forecast and alert plant operators and engineers about poor boiler conditions which may occur as a result of incoming coal and/or current power plant operating conditions. The Combustion System Performance Indices (CSPI) and CoalTracker (CT) programs predicts fireside performance of the plant including slagging, fouling, erosion, slag flow, strength development (sintering/densification), and slag layer thickness based on the composition of delivered coal. CT program is tailored for each plant and is used to track the coal from the point of delivery to the burner. The most successful application of the CSPI-CT has been at plants where the coal composition is determined through the use of a full stream elemental analyzers based on prompt gamma neutron analysis (PGNAA). The CSPI-CT program information is used by coal procurement, coal mining and plant operations personnel to select and blend coal properties for the best plant performance.

01 COAL, LIGNITE, AND PEAT↗

Time-of-Flight Calculations with Multiple Beam Phase Monitors: Calibration, Jitter Analysis & Energy Measurement

This report describes time-of-flight (ToF) beam energy measurements with multiple phase monitors in a beam line with no acceleration. Measurement uncertainty is quantified via rigorous treatment of beam-based phase monitor calibration and jitter analysis of the accelerator system. Experimental results in the Superconducting Linac (SCL) of the Spallation Neutron Source (SNS) are presented.

43 PARTICLE ACCELERATORS↗

Naval Reactors Facility Environmental Monitoring Report (CY2020)

This report presents the results of the radiological and non-radiological environmental monitoring programs for 2020 at the Naval Reactors Facility (NRF). Current operations at NRF are in compliance with applicable regulations governing use, emission, and disposal of solid, liquid, and gaseous materials. The results obtained from the environmental monitoring programs verify that releases to the environment from operations at NRF did not have any adverse effect on human health or the environment. Evaluation of the environmental data confirms that the operation of NRF continues to have no adverse effect on the environment or the health and safety of the general public. Furthermore, a conservative assessment of radiation exposure to the general public as a result of NRF operations demonstrated that the maximum potential dose received by any member of the public was well below the most restrictive dose limits prescribed by the US Environmental Protection Agency (EPA), the US Department of Energy (DOE), and the Nuclear Regulatory Commission.

54 ENVIRONMENTAL SCIENCES↗

Knolls Laboratory and Kesselring Site Environmental Monitoring Report (CY2019)

The results of the effluent and environmental monitoring programs at the Knolls Laboratory and Kesselring Site are summarized and assessed in this report. Tables 1 - 4 summarize the major elements of the environmental monitoring programs at each site. Information regarding the U.S. Department of Energy – Office of Environmental Management (DOE-EM) Separations Process Research Unit (SPRU) Disposition Project (SPRU DP), is also included in this report. Operations at the Knolls Laboratory, SPRU, and the Kesselring Site continue to have no adverse effect on human health and the quality of the environment.

54 ENVIRONMENTAL SCIENCES↗

Naval Reactors Facility Environmental Monitoring Report (CY2019)

This report presents the results of the radiological and non-radiological environmental monitoring programs for 2019 at the Naval Reactors Facility (NRF). Current operations at NRF are in compliance with applicable regulations governing use, emission, and disposal of solid, liquid, and gaseous materials. The results obtained from the environmental monitoring programs verify that releases to the environment from operations at NRF did not have any adverse effect on human health or the environment. Evaluation of the environmental data confirms that the operation of NRF continues to have no adverse effect on the environment or the health and safety of the general public. Furthermore, a conservative assessment of radiation exposure to the general public as a result of NRF operations demonstrated that the maximum potential dose received by any member of the public was well below the most restrictive dose limits prescribed by the US Department of Energy (DOE) and the Nuclear Regulatory Commission.

54 ENVIRONMENTAL SCIENCES↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmentally Adaptive, Multiband Software-Defined-Radar for Monitoring of Item of Interest in a Dynamically Cluttered Room

High-resolution multi-frequency radars when networked together, form a robust and seamless monitoring system for high-valued items. The multi-look-direction radar network investigated by LLNL and DSI, operates at 77 GHz and 5.8GHz, and is capable of detection at centimeter resolution movement of objects of interest. This dual frequency radar (unlike optical methods) can operate under various environments with conditions such a smoke, dust, and other natural or manmade obscurations. In addition, the multiband network radar is based on low-cost FCC approved EM specifications and can be scaled with the dimensions of the room and objects under consideration by user-defined inputs. Furthermore, the underlying radar signal processing based on software-defined radar engine is adaptive to its operational environment, where operators can input the size of the facility and object of interest and the distance between the object and radar. Finally, this multi-frequency radar employs a host of change detection and machine learning algorithms to reach performance levels in terms of high probability of detection and low false alarm rates while the monitoring state of the object can be reported remotely.

42 ENGINEERING↗

Strategic Petroleum Reserve Enhanced Monitoring Compendium (FY 2022)

The Strategic Petroleum Reserve (SPR) is the world's largest supply of emergency crude oil. The reserve consists of four sites in Louisiana and Texas. Each site stores crude in deep, underground salt caverns. It is the mission of the SPR's Enhanced Monitoring Program to examine all available data to inform our understanding of each site. This report discusses the monitoring data, processes, and results for each of the four sites for fiscal year 2022.

02 PETROLEUM↗

Continuous Particle Monitoring and Removal for Molten Chloride CSP Systems

This report describes the technologies that were developed as part of the Continuous Particle Monitoring and Removal for Molten Chloride CSP Systems project that was funded by the EERE Solar Energy Technologies Office during FY2021. This project consisted of two main tasks: (1) the development electrical resistance tomography (ERT) sensors to provide particle sensing capabilities for CSP-relevant molten chloride salts, and (2) the development of vortex separation technologies to enable efficient removal of particles from the salt. Both of these tasks are crucial because, although the Gen3 CSP chloride heat transfer fluid is inexpensive and can achieve high temperatures, major issues with erosion corrosion and clogging can arise from the presence of MgO particles within the salt. The particle monitoring and removal technologies were both demonstrated over the course of this project. The ERT sensors were able to achieve their performance targets by providing accurate particle concentration measurements over a range from 0.0 to 8.0 wt%. The vortex separators were able to demonstrate separation of particles from molten salt streams, but the separation efficiencies were lower than the targeted level of 90%. With further development and deployment, these technologies will ultimately help to enable successful long-term operations of CSP systems that make use of high-temperature chloride salts.

14 SOLAR ENERGY↗

Post-Closure Inspection and Monitoring Report for Surface Corrective Action Unit 417 at the Central Nevada Test Area, Nevada, Site

This report documents the biennial postclosure site inspections conducted in June 2018 at the surface Corrective Action Unit (CA U) 417 at the Central Nevada Test Area, Nevada, Site. The UC-I, UC-3, and UC-4 sites are inspected every 2 years, in accordance with the Post-Closure Monitoring Plan provided in the CAU 417 Closure Report published in 2001. The requirements for postclosure monitoring have been modified over the years through negotiations with the Nevada Division of Environmental Protection (NDEP). Modifications were documented through three separate Records of Technical Change to the Closure Report, which were approved by NDEP in 2003, 2011, and 2015. The UC-1, UC-3, and UC-4 sites were all observed as being in good condition during the 2018 inspections. A few minor cracks on the UC-1 Central Mud Pit cover were repaired during the UC- I inspection. A concrete monument at the northeast corner of Mud Pit U3E at the UC-3 site had some damage near the top of the monument, but the damage has not impacted the functionality of the monument or survey pin on top of the monument. No issues were identified at the UC-4 site. No maintenance or additional repair activities are recommended at the UC-1, UC-3, and UC-4 sites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Collision Detection and Site Monitoring for Avian and Bat Species for Offshore Wind Energy (Final Technical Report)

This final technical report summarizes the outcomes from a project that aimed to design, build, and test a persistent and autonomous monitoring system for avian and bat collisions with offshore wind turbines blades and structures. The system comprises four primary sensor modules: 1) on-blade sensor modules for collision detection and dual-vision image capture on each blade with both visible light and near-infrared imagers; 2) additional on-blade collision sensors mounted further from the root; 3) a nacelle-mounted unit including a 360º camera and ultrasonic microphone array; and, 4) an on-blade, high-performance infrared camera module. Primary targeted outcomes were high sensitivity for the detection of blade strikes from bats and small birds, and automatically captured visual confirmation of the striking object; these features are critical for monitoring offshore wind turbine installations, where ground-based methods are not viable. In addition, local recording will provide a long-term sensor recording database. Following laboratory validation, field testing was conducted on an operational wind turbine in collaboration with the National Wind Technology Center at the NREL Flatirons campus over two planned field tests.

17 WIND ENERGY↗

Detection of System Drift for the Health Monitoring of an X-ray CT Scientific Instrument

This SE296 Capstone Project technical report is being submitted as a final requirement of the UCSD Master of Science in Structural Engineering with specialization in Structural Health Monitoring (SHM) and Nondestructive Evaluation (NDE). The Capstone provides students the opportunity to apply knowledge in their technology areas towards the solution of an SHM or NDE problem. As an employee of the Lawrence Livermore National Laboratory and NDE/NCI team member, I chose to apply the SHM design paradigm taught at UCSD to improve the health monitoring of the X-ray Micro-Computed Tomography (MCT) system. I would like to thank LLNL’s Dr. Harry Martz for serving as my mentor during this project and the entire LLNL MCT technical team for answering my questions and contributing to my knowledge. I would also like to thank Prof. Michael Todd for recruiting me to the UCSD NDE/SHM program and serving as my graduate advisor.

42 ENGINEERING↗

Raman Spectroscopy Based On-Line, Real-Time Monitoring to Reduce Composition Uncertainties: Enhanced sensitivity through optimization of Raman Parameters

Optical spectroscopy-based on-line monitoring of Hanford processing streams can enable real-time characterization of chemical composition of process streams and batches, ultimately enabling and enhancing process control. It can provide immediate feedback on process conditions and has the potential to reduce the needed number of grab sample collections, thereby reducing times and costs associated with laboratory processing. Here we discuss the utilization of Raman spectroscopy to quantify multiple target analytes that are common within Hanford tanks and waste processing streams. Analytes include: nitrate, nitrite, carbonate, chromate, sulfate, phosphate, hydroxide, oxalate, ammonia, and aluminate. Most notably in this work, Raman applications to low-concentration streams are explored and optimized. Raman instrument specifications are compared; specifically, the impact of utilizing three different Raman excitation wavelengths, 405, 532, and 671 nm, is discussed. Also, Raman data collection parameters such as collection time and spectral averaging are measured and discussed. Finally, optical libraries of chemical targets were collected using optimized collection parameters and chemometric models were built to automate quantification of chemical targets. These models were validated through application to simulants and real Hanford process samples. Chemometric models performed well on both training and validation sets, suggesting these approaches can be successfully applied to on-line and real-time monitoring of low concentration Hanford processing streams. The use of the combine Raman wave lengths with the enhanced chemometric models for the low concentration streams significantly improved the chemical detection levels and significantly reduced uncertainties of those measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗