Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

In Situ Wind and Turbulence Measurements in a Field of Full-Size Parabolic Trough Solar Collectors

Concentrated Solar Power (CSP) is a promising method for using Solar power for electricity generation with thermal energy storage. One of the primary drivers of structural design costs of CSP collector structures is wind loading. To date, the design of these structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights on structural dynamic response, and generating a first-of-a-kind, comprehensive, high-resolution wind-loading dataset available for validating simulations of wind loading on collector structures. The measurements at NSO consist of Sonic anemometers on masts at different heights to characterize the incoming flow and conditions within and above the trough field, in combination with a Doppler Lidar scanning the horizontal plane above the troughs. The wind measurements at NSO have been continuously operating since October 2021 and provide a year-long dataset characterizing wind and turbulence conditions. The structural load measurements start in November 2022 and will complement the wind measurements. In this poster, we present first results of the wind measurement campaign by highlighting days with different atmospheric flow conditions. We identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. The highest loads are expected when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest loads and block the subsequent rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales change. These affected conditions produce unique load cases on the structures that will be captured by the load measurements. If the wind blows along the trough rows, wind and turbulence conditions are less influenced by the troughs.

atmospheric turbulence↗

In Situ Wind and Turbulence Measurements in a Field of Full-Size Parabolic Trough Collectors

Concentrated Solar Power (CSP) is a promising method for using Solar power for electricity generation with thermal energy storage. One of the primary drivers of structural design costs of CSP collector structures is wind loading. To date, the design of these structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights on structural dynamic response, and generating a first-of-a-kind, comprehensive, high-resolution wind-loading dataset available for validating simulations of wind loading on collector structures. The measurements at NSO consist of Sonic anemometers on masts at different heights to characterize the incoming flow and conditions within and above the trough field, in combination with a Doppler Lidar scanning the horizontal plane above the troughs. The wind measurements at NSO have been continuously operating since October 2021 and provide a year-long dataset characterizing wind and turbulence conditions. The structural load measurements start in November 2022 and will complement the wind measurements. In this poster, we present first results of the wind measurement campaign by highlighting days with different atmospheric flow conditions. We identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. The highest loads are expected when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest loads and block the subsequent rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales change. These affected conditions produce unique load cases on the structures that will be captured by the load measurements. If the wind blows along the trough rows, wind and turbulence conditions are less influenced by the troughs.

concentrated solar power↗

Wind Loading on Parabolic Trough Collectors: Wind and Structural Loads Measurements at an Operational Powerplant

Concentrated Solar Power (CSP) is a promising method for using solar power for electricity generation with thermal energy storage for industrial applications. Solar collectors constitute almost 1/3 of the total cost of the power plant. One of the primary drivers of unrealiability of these collectors is wind-driven loading of mirrors, support structures, and drives. To date, the design of the solar collector structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) parabolic trough powerplant. At this plant, parabolic trough solar collectors track the sun from east to west in the course of a day and face varying wind loads depending on the wind properties and the angle of the troughs. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights into structural dynamic response, and generating a comprehensive wind-loading dataset for validating simulations of wind loading on collector structures. The measurements at NSO consist of sonic anemometers on masts at different heights to characterize the incoming flow and conditions at four trough rows at the edge of the trough field. In addition, a Doppler Lidar scans the horizontal plane above the troughs. The wind measurements at NSO have been continuously collecting data since October 2021 and are combined with structural load measurements that started in November 2022. The load measurements were installed on the same four outermost trough rows and include support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Measurements are planned to continue until May 2023, providing a first-of-a-kind, high-resolution multi-month dataset of combined wind and load measurements. In this presentation, we show first results of the measurement campaign. Based on the measurements, we identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. Most interactions between incoming wind and the trough field are observed when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest wind speed and block the downwind rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales are smaller after the first row. This leads to the highest static loads (bending and torque moments) at the first row but potentially increased dynamic loads within the field. We illustrate our findings with case studies focused on different wind conditions and will present fatigue analysis to highlight the impact of wind-driven loads on collector structures.

CSP collectors↗

Precision Control of a Slender High Payload 22 DoF Nuclear Robot System: TARM Re-ascending - 18346

The DEMO Remote Maintenance System (RMS) functional requirements represent a truly extreme environment. In the current design of the in-vessel RMS, blanket segment maintenance represents one of the most challenging tasks overall. As part of the JET (Joint European Torus) project, an ambitious 22 DoF transporter was created, the TARM (Telescopic Articulated Remote MAST). The TARM has been identified as a suitable test bed for the early development and verification of the control system and structural simulators. This paper outlines the development of the TARM into a multi-purpose test-rig for Precision Control of a Slender High Payload large DoF Nuclear Robot System. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of Two Alternative Types of Unmanned Aerial Vehicles for Indoor Spaces - 18502

This paper examines two lesser known, but technological mature, unmanned aerial vehicle (UAVs) approaches to working in indoor spaces. Tethered UAVs reduce safety concerns by physically limiting the range of the UAV. The tether can provide other advantages including supplying long-term power, carrying heavier payloads, enabling uninterrupted communications, better performance in high winds, and providing more flexibility in viewpoints than an aerial mast. Caged UAVs reduce safety concerns by protecting the UAV, and its environment, form damage due to collisions or contact. The protective cage can offer other advantages including bracing or rolling the UAV over a surface to simply control or reduce energy, lessen wind resistance, and allow the UAV to inspect a structure at close, repeatable distances. The paper established the problems associated with flying UAVs in indoor spaces. It reviews the state of the practice for both tethered and caged UAVs, then compares the two approaches to traditional multi-rotor UAVs. The paper concludes that commercially available tethered and caged UAVs are useful and ready for immediate adoption. (authors)

42 ENGINEERING↗

Keep It Smart and Simple - Henriette - The Advanced Designed Drum Gripper for Remote Handling Tasks - 19327

A power manipulator has many applications in the handling, treatment and packaging of radioactive waste. In high radiation environments, where humans cannot work safely, a power manipulator is essential to perform difficult and heavy tasks. For more than 40 years, Waelischmiller has provided power manipulators to the nuclear market. Specifically in a high radiation nuclear environment, electrical driven manipulators are preferred. The basic design of a power manipulator is divided into the following parts: Bridge, carriage, telescopic mast and manipulator arm. All parts are customizable in length, width and capacity. The standard power manipulator version is equipped with a manipulator arm. For the nuclear waste disposal industry, there is a special need for a drum gripper. Drums are used for packing low, medium or high activated material and for storage. After packing, the drums must be handled remotely. For both tasks, a power manipulator with a drum gripper is needed. For this project KTE (Kerntechnische Entsorgung Karlsruhe GmbH) required a total refurbishment of equipment in a cell used for handling, sorting and packaging radioactive waste drums. The power manipulator was obsolete and provided low availability and through put. This cell was an essential asset in their decommissioning process and was impacting KTE's ability to meet their volume objectives. Our challenge was to develop a new system with few details from the original cell construction. The new manipulator must meet all capabilities of the old system and in addition have the ability to achieve 180 degree tilting of the drums. An additional challenge was the requirement to use the existing rails in the cell which were very close to the roof structure which required a special design. Our project, named internally Henriette, is the first of its kind. The drum gripper is based on the power manipulator A1000 series. The biggest challenges in this project were to adapt the standard components of the power manipulator to the non-standard type of gripper to have 180 deg. tilting of the drum and a handling capacity of 1200 kg in the whole working range. The new manipulator fits to the old rails and is mountable in a hot cell with restricted access and can operate with the other A1000 manipulator which is located in the cell. The result is a system with no external wiring, maintenance-free and easy to decontaminate. Other features include a 5 t auxiliary hoist on additional and parallel carriages, emergency drives for bridge and carriage, emergency drive for telescope turn movement and emergency lifting unit for telescope. A tilt and pan holder for camera on the telescope and external mechanical emergency drives on the gripper were also essential. This paper will address the complexity, challenges and engineering ingenuity required to replace very old and obsolete equipment with a state-of-the-art system within very limited physical space and within a high radiation environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors

The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum 252Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is 4.8+0.7-0.9% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at ~4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to ~75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.

dark matter, detector calibration, ionization yiel↗

Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c2) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c2 compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4×10-42 cm2 at 5 GeV/c2, a factor of ~2.5 improvement over the previous CDMSlite result.

Agnese, R↗

Ion-Pair Reorganization Regulates Reactivity in Photoredox Catalysts

Cyclometalated and polypyridyl complexes of d6 metals are promising photoredox catalysts, using light to drive reactions with high kinetic or thermodynamic barriers via the generation of reactive radical intermediates. However, while tuning of their redox potentials, absorption energy, excited-state lifetime and quantum yield are well-known criteria for modifying activity, other factors could be important. Here we show that dynamic ion-pair reorganization controls the reactivity of a photoredox catalyst, [Ir[dF(CF3)ppy]2(dtbpy)]X. Time-resolved dielectric-loss experiments show how counter-ion identity influences excited-state charge distribution, evincing large differences in both the ground- and excited-state dipole moment depending on whether X is a small associating anion (PF6-) that forms a contact-ion pair versus a large one that either dissociates or forms a solvent-separated pair (BArF4-). These differences correlate with the reactivity of the photocatalyst toward both reductive and oxidative electron transfer, amounting to a 4-fold change in selectivity toward oxidation versus reduction. These results suggest that ion pairing could be an underappreciated factor that modulates reactivity in ionic photoredox catalysts.

catalysis↗

Constraints on dark photons and axionlike particles from the SuperCDMS Soudan experiment

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Projected sensitivity of the SuperCDMS SNOLAB experiment

SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass particles (with masses ≤ 10 GeV/c^2) that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~1×10^-43 cm^2 for a dark matter particle mass of 1 GeV/c^2, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low-energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced H-3 and naturally occurring Si-32 will be present in the detectors at some level. Even if these backgrounds are 10 times higher than expected, the science reach of the HV detectors would be over 3 orders of magnitude beyond current results for a dark matter mass of 1 GeV/c^2. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particles with masses ≳5 GeV/c^2. The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the “neutrino floor,” where coherent scatters of solar neutrinos become a limiting background.

Agnese, R.↗

New Results from the Search for Low-Mass Weakly Interacting Massive Particles with the CDMS low ionization Threshold Experiment

The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg day, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite.

New Results, Low-Mass, Mazzive Particles, CDMS Low↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved effcient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3x10^5), as well as the strongest limits for charge <= e/160, with a minimum vertical intensity of 1.36 x 10^-7 cm^-2s^-1sr^-1 at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^2 to 100 TeV/c^2) and cover a wide range of beta-gamma values (0.1--10^6), thus excluding non-relativistic LIPs with beta-gamma as small as 0.1 for the first time.

Alkhatib, I↗

Response to comment on ‘SARS-CoV-2 suppresses anticoagulant and fibrinolytic gene expression in the lung’

Early in the SARS-CoV-2 pandemic, we compared transcriptome data from hospitalized COVID-19 patients and control patients without COVID-19. We found changes in procoagulant and fibrinolytic gene expression in the lungs of COVID-19 patients. These findings have been challenged based on issues with the samples. We have revisited our previous analyses in the light of this challenge and find that these new analyses support our original conclusions.

59 BASIC BIOLOGICAL SCIENCES↗