Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Application of the Concepts of Load State, Load Space, and Output Space to Strain-Gage Balances

The concepts of load state, load space, and output space are used to describe elements of the development of a load prediction process for a six–component strain–gage balance. The use of these terms adds clarity during the selection of the independent and dependent variables for the development of the load prediction process. First, the control volume model of a strain–gage balance is reviewed as it helps better understand the role of loads, outputs, and state variables during the load prediction. Then, the description of the absolute load datum in both the load space and the output space is discussed. It is concluded that the use of the difference between a raw output and the natural zero of a balance gage has a key advantage for the definition of the output space. In that case, the origin of the output space will also describe the absolute load datum of the balance. Finally, details of the application of the concepts of load state, load space, and output space to two commonly used balance load prediction methods are discussed.

strain-gage balance↗

SSME alternate turbopump (pump section) axial load analysis

A flow balancing computer program constructed to calculate the axial loads on the Space Shuttle Main Engine (SSME) alternate turbopumps (ATs) pump sections are described. The loads are used in turn to determine load balancing piston design requirements. The application of the program to the inlet section, inducer/impeller/stage, bearings, seals, labyrinth, damper, piston, face and corner, and stationary/rotating surfaces is indicated. Design analysis results are reported which show that the balancing piston's designs are adequate and that performance and life will not be degraded by the turbopump's axial load characteristics.

Crease, G. A.↗

Self-balancing beam permits safe, easy load handling under overhang

The use of a self-balancing I-beam with a counterweight and motor simplifies moving heavy loads that are inaccessible for cranes. The beam cannot be overloaded, as the counterweight will not balance the load, and thus acts as an automatic safety device.

Edwards, O. H.↗

Analysis of Sting Balance Calibration Data Using Optimized Regression Models

Calibration data of a wind tunnel sting balance was processed using a search algorithm that identifies an optimized regression model for the data analysis. The selected sting balance had two moment gages that were mounted forward and aft of the balance moment center. The difference and the sum of the two gage outputs were fitted in the least squares sense using the normal force and the pitching moment at the balance moment center as independent variables. The regression model search algorithm predicted that the difference of the gage outputs should be modeled using the intercept and the normal force. The sum of the two gage outputs, on the other hand, should be modeled using the intercept, the pitching moment, and the square of the pitching moment. Equations of the deflection of a cantilever beam are used to show that the search algorithm s two recommended math models can also be obtained after performing a rigorous theoretical analysis of the deflection of the sting balance under load. The analysis of the sting balance calibration data set is a rare example of a situation when regression models of balance calibration data can directly be derived from first principles of physics and engineering. In addition, it is interesting to see that the search algorithm recommended the same regression models for the data analysis using only a set of statistical quality metrics.

Ulbrich, Norbert↗

Monitoring dynamic loads on wind tunnel force balances

Two devices have been developed at NASA Langley to monitor the dynamic loads incurred during wind-tunnel testing. The Balance Dynamic Display Unit (BDDU), displays and monitors the combined static and dynamic forces and moments in the orthogonal axes. The Balance Critical Point Analyzer scales and sums each normalized signal from the BDDU to obtain combined dynamic and static signals that represent the dynamic loads at predefined high-stress points. The display of each instrument is a multiplex of six analog signals in a way that each channel is displayed sequentially as one-sixth of the horizontal axis on a single oscilloscope trace. Thus this display format permits the operator to quickly and easily monitor the combined static and dynamic level of up to six channels at the same time.

Ferris, Alice T.↗

Recovery act: development of design and simulation tool for hybrid geothermal heat pump system

The ground source heat pump (GSHP) system is one of the most energy efficient HVAC technologies in the current market. However, the heat imbalance may degrade the ability of the ground loop heat exchanger (GLHX) to absorb or reject heat. The hybrid GSHP system, which combines a geothermal well field with a supplemental boiler or cooling tower, can balance the loads imposed on the ground loop heat exchangers to minimize its size while retaining superior energy efficiency. This paper presents a recent simulation-based study with an intention to compare multiple common control strategies used in hybrid GSHP systems, including fixed setpoint, outside air reset, load reset, and wetbulb reset. A small office in Oklahoma City conditioned by a hybrid GSHP system was simulated with the latest version of eQUEST 3.7[1]. The simulation results reveal that the hybrid GSHP system has the excellent capability to meet the cooling and heating setpoints during the occupied hours, balance thermal loads on the ground loop, as well as improve the thermal comfort of the occupants with the undersized well field.

15 GEOTHERMAL ENERGY↗

Comparative study of control strategies for hybrid GSHP system in the cooling dominated climate

The ground source heat pump (GSHP) system is one of the most energy efficient HVAC technologies in the current market. However, the heat imbalance may degrade the ability of the ground loop heat exchanger (GLHX) to absorb or reject heat. The hybrid GSHP system, which combines a geothermal well field with a supplemental boiler or cooling tower, can balance the loads imposed on the ground loop heat exchangers to minimize its size while retaining superior energy efficiency. This paper presents a recent simulation-based study with an intention to compare multiple common control strategies used in hybrid GSHP systems, including fixed setpoint, outside air reset, load reset, and wetbulb reset. A small office in Oklahoma City conditioned by a hybrid GSHP system was simulated with the latest version of eQUEST 3.7 [1]. In the end, the simulation results reveal that the hybrid GSHP system has the excellent capability to meet the cooling and heating setpoints during the occupied hours, balance thermal loads on the ground loop, as well as improve the thermal comfort of the occupants with the reduced size well field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Human-in-the-Loop Evaluation of Multi-Sector Planning in Mixed Equipage Airspace (MSP III)

A human-in-the-loop (HITL) simulation was conducted in May 2010 to determine the feasibility and value 01 conducting multi-sector planning (MSP) operations in a mixed equipage environment. Aircraft were categorized as equipped or unequipped based on the presence or absence of an air-ground data communications (Data Comm) capability for receiving auto-loadable clearances and transfer of communication messages from the air navigation service provider (ANSP). The purpose of the study was to determine the feasibility and possible benefits of introducing multi-sector planning in a mixed equipage context, or whether Data Comm equipage was required for MSP operations. Each test scenario presented one of three different equipage levels to the controllers (10%, 50% or 90% equipped aircraft), so that the operational impact of different equipage levels could be observed. Operational feasibility assessment addressed two related questions: (1) are MSP operations feasible for unequipped aircraft, and (2) are they feasible in a mixed equipage context. Similarly, two categories of potential benefits were explored: (1) system performance improvements (e.g., throughput, workload) associated with MSP at different equipage levels, and (2) the possibility of providing differential service for equipage through MSP operations. Tool requirements (for both planning and controller stations), as well as planning and coordination procedures - within facility (traffic management unit/operational area) and within sector (R-Side/D-Side) - were two other topics addressed in the study. Overall, results suggested that MSP operations were feasible in a mixed equipage environment and that the tools were effective with both equipped and unequipped aircraft. Using the MSP tools, traffic management coordinators were able to manage controller task load, effectively balancing throughput with complexity and controller task load at each of the three equipage levels tested.

Smith, Nancy↗

Balancing Power Absorption Against Structural Loads With Viscous Drag and Power-Takeoff Efficiency Considerations

The focus of this paper is to balance power absorption against structural loading for a novel fixed-bottom oscillating surge wave energy converter in both regular and irregular wave environments. The power-to-load ratio will be evaluated using pseudospectral control (PSC) to determine the optimum power-takeoff (PTO) torque based on a multiterm objective function. This paper extends the pseudospectral optimal control problem to not just maximize the time-averaged absorbed power but also include measures for the surge-foundation force and PTO torque in the optimization. The objective function may now potentially include three competing terms that the optimizer must balance. Separate weighting factors are attached to the surge-foundation force and PTO control torque that can be used to tune the optimizer performance to emphasize either power absorption or load shedding. To correct the pitch equation of motion, derived from linear hydrodynamic theory, a quadratic-viscous-drag torque has been included in the system dynamics; however, to continue the use of quadratic programming solvers, an iteratively obtained linearized drag coefficient was utilized that provided good accuracy in the predicted pitch motion. Furthermore, the analysis considers the use of a nonideal PTO unit to more accurately evaluate controller performance. The PTO efficiency is not directly included in the objective function but rather the weighting factors are utilized to limit the PTO torque amplitudes, thereby reducing the losses resulting from the bidirectional energy flow through a nonideal PTO. Furthermore, results from PSC show that shedding a portion of the available wave energy can lead to greater reductions in structural loads, peak-to-average power ratio, and reactive power requirement.

16 TIDAL AND WAVE POWER↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

balancing authority↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

14 SOLAR ENERGY↗

Application of Ensemble Sensitivity Analysis to Observation Targeting for Short-term Wind Speed Forecasting in the Washington-Oregon Region

To economically and reliably balance electrical load and generation, electrical grid operators, also called Balancing Authorities (BA), need highly accurate electrical power generation forecasts in time frames ranging from a few minutes to six hours ahead. As wind power generation increases, there is a requirement to improve the accuracy of 0- to 6-hour ahead wind power forecasts. Forecasts covering this short look-ahead period have depended heavily on short-term trends obtained from the actual power production and meteorological data of a wind generation facility. Additional data are often available from Numerical Weather Prediction (NWP) models and sometimes from off-site meteorological towers near wind generation facilities.

17 WIND ENERGY↗

Utilization of Model Predictive Control to Balance Power Absorption Against Load Accumulation: Preprint

Wave energy converter (WEC) control strategies have been primarily focused on maximizing power absorption. The use of model predictive control strategies allows for a finite-horizon, multiterm objective function to be solved. This work utilizes a multiterm objective function to maximize power absorption while minimizing the structural loads on the WEC system. Furthermore, a Kalman filter and autoregressive model were used to estimate and forecast the wave exciting force and predict the future dynamics of the WEC. The WEC's power-take-off time-averaged power and structural loads under a perfect forecast assumption in irregular waves were compared against results obtained from the Kalman filter and autoregressive model to evaluate model predictive control performance.

16 TIDAL AND WAVE POWER↗

Utilization of Model Predictive Control to Balance Power Absorption Against Load Accumulation

Wave energy converter (WEC) control strategies have been primarily focused on maximizing power absorption. The use of model predictive control strategies allows for a finite-horizon, multiterm objective function to be solved. This work utilizes a multiterm objective function to maximize power absorption while minimizing the structural loads on the WEC system. Furthermore, a Kalman filter and autoregressive model were used to estimate and forecast the wave exciting force and predict the future dynamics of the WEC. The WEC's power-take-off time-averaged power and structural loads under a perfect forecast assumption in irregular waves were compared against results obtained from the Kalman filter and autoregressive model to evaluate model predictive control performance.

16 TIDAL AND WAVE POWER↗

Load Schedule Design Improvements for the Calibration of NASA's Semi-span Balances

Improvements of the load schedule design for the calibration of NASA's semi-span balances are discussed. These improvements became possible after a minor hardware change was made to Calspan's Large Load Rig. This change moves normal and axial force load points 12 inches closer to the balance moment center. Resulting data quality improvements are significant because Calspan's Large Load Rig cannot currently apply forces at the balance moment center of a semi-span balance. Now, the supported set of rolling and yawing moment arms is 28, 38, and 48 inches. Consequently, the new load schedule design better supports expected normal and axial force locations on semi-span models that are tested in the NASA Ames 11-ft Transonic Wind Tunnel. In addition, estimates of the primary sensitivities of the normal force, axial force, rolling moment, and yawing moment have become more accurate as the applied normal and axial forces have moved closer to the balance moment center. Fundamental moment arm range requirements and Calspan's hardware updates are discussed. In addition, calibration and check load analysis results of NASA's ARC30K semi-span balance are presented to illustrate benefits of the hardware changes.

wind tunnel test↗

Strain-gage balance calibration of a magnetic suspension and balance system

A load calibration of the NASA 13-in magnetic suspension and balance system (MSBS) is described. The calibration procedure was originally intended to establish the empirical relationship between the coil currents and the external loads (forces and moments) applied to a magnetically suspended calibrator. However, it was discovered that the performance of a strain-gage balance is not affected when subjected to the magnetic environment of the MSBS. The use of strain-gage balances greatly reduces the effort required to perform a current-vs.-load calibration as external loads can be directly inferred from the balance outputs while a calibrator is suspended in MSBS. It is conceivable that in the future such a calibration could become unnecessary, since an even more important application for the use of a strain-gage balance in MSBS environment is the acquisition of precision aerodynamic force and moment data by telemetering the balance outputs from a suspended model/core/balance during wind tunnel tests.

Roberts, Paul W.↗

Load Schedule Design Improvements for the Calibration of NASA's Semi-span Balances

Improvements of the load schedule design for the calibration of NASA's semi-span balances are discussed. These improvements became possible after a minor hardware change was made to Calspan's Large Load Rig. This change moves normal and axial force load points 12 inches closer to the balance moment center. Resulting data quality improvements are significant because Calspan's Large Load Rig cannot currently apply forces at the balance moment center of a semi-span balance. Now, the supported set of rolling and yawing moment arms is 28 inches, 38 inches, and 48 inches. Consequently, the new load schedule design better supports expected normal and axial force locations on semi-span models that are tested in the NASA Ames 11-ft Transonic Wind Tunnel. In addition, estimates of the primary sensitivities of the normal force, axial force, rolling moment, and yawing moment have become more accurate as the applied normal and axial forces have moved closer to the balance moment center. Fundamental moment arm range requirements and Calspan's hardware updates are discussed in detail. In addition, calibration analysis results of NASA's ARC30K semi-span balance are presented to illustrate benefits of the hardware changes.

wind tunnel test↗

Machine Learning-Based Investigation of the Associations between Residential Power Consumption and Weather Conditions

Machine learning feature selection analyses were conducted to understand the impact of various weather attributes on power electricity demand and its components in the northwest United States. Load profiles data were obtained from the Northwest Energy Efficiency Alliance (NEEA) and processed to yield hourly load profiles with the same temporal resolution as the weather conditions data obtained from the National Oceanic and Atmospheric Administration (NOAA) for representative weather stations. The data were divided into five seasons; for each season, for each load component, the influences of weather factors were evaluated and quantified using cross-correlation, principal component analysis, and mutual information evaluation; then predictive models were developed based on the ranked/screened factors using the regression tree (RT) approach. After multi-fold cross-validation, the optimal complexity/depth of the regress tree models is found to vary for different load components, and the prediction accuracy using RT and weather data can be higher than 80% for heating and refrigeration, or lower than 30% for vent and cooking. The study provides guidance on improvement of load profile generation, or even serves as a standalone predictive tool for approximating load profiles in balance authorities or climate zones where load profile data is absent.

load composite, load profiling, NEEA, mutual infor↗