Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laboratory procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

TA-18-1 Slotin Building Restoration – Summary of Work to be Performed

The National Historic Preservation Act (NHPA) requires LANL to identify, evaluate, record, and protect eligible historic properties like TA-18-1 Slotin Building. The Environmental Protection and Compliance-Environmental Stewardship (EPC-ES) Cultural Resources program consults with the New Mexico State Historic Preservation Office (SHPO) on undertakings that may affect these properties. TA-18-1 Slotin Building is an exceptionally significant Manhattan Project Property that has been determined eligible for the National Register of Historic Places and is included within the boundary of the Manhattan Project National Historical Park. The building was constructed in 1946 and served as laboratory space for criticality testing. It is the location of the May 1946 criticality accident that resulted in the death of Louis Slotin. As a result of the accident, new procedures and designs for criticality experiments were implemented to prevent further accidents.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Optimization of boron carbide density using direct current sintering for use as sputtering sources at the National Ignition Facility

Several experimental trials were conducted to determine optimal sintering parameters and compositions for purchased boron carbide powder using spark plasma sintering/direct current sintering. Sputtering targets used to create ablators for the National Ignition Facility have been unable to survive post processing procedures suggesting that in-house fabrication may yield better results due to extended control.

36 MATERIALS SCIENCE↗

Microbial ecology measurement system

The sensitivity and potential rapidity of the PIA test that was demonstrated during the feasibility study warranted continuing the effort to examine the possibility of adapting this test to an automated procedure that could be used during manned missions. The effort during this program has optimized the test conditions for two important respiratory pathogens, influenza virus and Mycoplasma pneumoniae, developed a laboratory model automated detection system, and investigated a group antigen concept for virus detection. Preliminary tests on the handling of oropharygeal clinical samples for PIA testing were performed using the adenovirus system. The results obtained indicated that the PIA signal is reduced in positive samples and is increased in negative samples. Treatment with cysteine appeared to reduce nonspecific agglutination in negative samples but did not maintain the signal in positive samples.

Source record↗

A review of some radiometric calibration problems and methods

The in-flight radiometric calibration instrumentation and procedures of the Landsat Thematic Mapper and the high-resolution visible-range instruments of SPOT are illustrated with drawings and diagrams, characterized, and compared. Problems encountered in the laboratory calibration process, minimizing the temporal instability of the systems, identifying anomalies in the electronics in flight, and rechecking the calibration are examined, and it is pointed out that the stability of the calibration systems is less than that of the instruments themselves. The use of carefully measured ground-site data and atmospheric parameters in combination with radiative-transfer models for periodic calibration is recommended.

Slater, P. N.↗

Activities of the Pilot Land Data System project

The University of Maryland's Remote Sensing Systems Laboratory submitted to NASA/Goddard an interim progress report on the work being conducted within its Pilot Land Data System IPLDS project. The Remote Sensing Systems Laboratory addressed the following tasks: (1) identify data types and data sources needed to describe the selected test sites in collaboration with Goddard's Hydrological Sciences Branch; (2) define the procedures necessary to access/acquire this data; (3) conduct meetings with the PLDS Systems Engineering Group to identify functional specification priorities for PLDS development; (4) assemble documentation on historical remotely sensed imagery and transfer of such information to the PLDS Data Management Group; (5) collect data identified by Goodard's Hydrological Sciences Branch for data set inventory in PLD; (6) develop a Workstation-PLDS system interface over high speed lines, (7) develop and test through a Phase 1 demonstration of a micro workstation to access PLDS; and (8) establish interdepartmental agreement of development of computer link for electronic access of water resources data from USGS.

Sircar, J. K.↗

Compositional diversity of the lunar North Pole: Preliminary analyses of Galileo SSI data

In December 1992, the Galileo spacecraft passed through the Earth-Moon system for its final gravity assist to Jupiter. The SSI camera obtained several 6-color mosaics of the lunar north polar region and the sunlit nearside and eastern limb at approximately 1.3 km/pixel. Initial analyses have concentrated on the north polar areas to assess the composition of the crust in that region. Representative 6-color calibration SSI spectra (typically 5 x 5 pixels) are shown. Photometric corrections have not yet been applied, and all spectra are scaled to unity at 0.56 microns. The data were first calibrated relative to MS2, a standard are in Mare Serenitatis (18.7 deg N, 21.5 deg E), and the top four plots of highlands, highland craters, maria, and mare craters are displayed relative to MS2. SSI spectra of areas measured with telescopic data (mare MT1/MS2 and mare crater MSA/MS2) agree well with previous data, confirming that the calibration procedures and SSI data are spectrally accurate. The bottom three plots of craters/sun have been calibrated to reflectance using previously obtained telescopic spectra of Apollo 16/MS2 (shown with Highlands/MS2) and laboratory spectra of mature Apollo 16 soil (shown for reference with the Highland Craters/Sun). Although some variations in these spectra mimic previously observed spectra of lunar terrains, several characteristics are unusual. Familiar and unfamiliar properties are observed in these northern latitudes and both types merit further investigation in their geologic context.

Pieters, C. M.↗

Wind Tunnel Balance Calibration: Are 1,000,000 Data Points Enough?

Measurement systems are typically calibrated based on standard practices established by a metrology standards laboratory, for example the National Institute for Standards and Technology (NIST), or dictated by an organization's metrology manual. Therefore, the calibration is designed and executed according to an established procedure. However, for many aerodynamic research measurement systems a universally accepted standard, traceable approach does not exist. Therefore, a strategy for how to develop a calibration protocol is left to the developer or user to define based on experience and recommended practice in their respective industry. Wind tunnel balances are one such measurement system. Many different calibration systems, load schedules and procedures have been developed for balances with little consensus on a recommended approach. Especially lacking is guidance the number of calibration data points needed. Regrettably, the number of data points tends to be correlated with the perceived quality of the calibration. Often, the number of data points is associated with ones ability to generate the data rather than by a defined need in support of measurement objectives. Hence the title of the paper was conceived to challenge recent observations in the wind tunnel balance community that shows an ever increasing desire for more data points per calibration absent of guidance to determine when there are enough. This paper presents fundamental concepts and theory to aid in the development of calibration procedures for wind tunnel balances and provides a framework that is generally applicable to the characterization and calibration of other measurement systems. Questions that need to be answered are for example: What constitutes an adequate calibration? How much data are needed in the calibration? How good is the calibration? This paper will assist a practitioner in answering these questions by presenting an underlying theory on how to evaluate a calibration based on objective measures. This will enable the developer and user to design calibrations with quantified performance in terms of their capability to meet the user's objectives and a basis for comparing existing calibrations that may have been developed in an ad-hoc manner.

Rhew, Ray D.↗

Airspace Technology Demonstration 2 (ATD-2) Integrated Surface and Airspace Simulation - Experiment Plan

This presentation describes the overview of the ATD-2 project and the integrated simulation of surface and airspace to evaluate the procedures of IADS system and evaluate surface metering capabilities via a high-fidelity human-in-the-loop simulation. Two HITL facilities, Future Flight Central (FFC) and Airspace Operations Laboratory (AOL), are integrated for simulating surface operations of the Charlotte-Douglas International Airport (CLT) and airspace in CLT TRACON and Washington Center.

ATD-2↗

Conducting Industrial Hygiene Exposure Assessments at Scale Using Non-Parametric Upper Tolerance Limits at the Hanford Site - 20439

Chemical vapors are generated in the radioactive waste storage tanks at the Hanford Site due to ongoing chemical and radiological activity. Hanford's Tank Operations Contractor conducts exposure assessments for individual tank farms to identify, evaluate, and recommend controls or other worker protection measures for chemical, physical, and biological hazards present within each tank farm. These exposure assessments conform to the American Industrial Hygiene Association assessment strategy and recommended statistical procedures. The exposure assessment process involved manually processing tens of thousands of records that were collected over several years and entered into a central database. Working with Pacific Northwest National Laboratory, this process has been largely automated, providing a scalable analysis process that reduced processing time by over 90%, while providing defensible results and improved data quality. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synthesis of Yttrium Oxide Particles for Interfacial Water Radiolysis Studies

Radiolysis of water produces hydrogen gas (H2), posing safety issues for nuclear reactors. Metal oxides can impact H2 formation when water is present on metal oxide surfaces. This presentation focuses on the development of a controllable synthesis of spherical yttrium oxide (Y2O3), that later will be tested for H2 production in water radiolysis. Y2O3 was synthesized via hydrothermal hydrolysis precipitation to form yttrium hydroxide (Y(OH)3), followed by high temperature decomposition to form Y2O3. Various synthesis conditions were tested to determine their impact on particle morphology including reaction time, cooling rate, reactant concentration, and inert atmospheres. Through short reaction times and rapid cooling rate, spherical, relatively uniform particles of 350 nm were obtained. Despite inert atmospheres, carbonate formation occurred in all particles. A calcination temperature of 800°C is necessary to remove impurities. Future work will aim to reduce carbonate formation and improve particle uniformity. The synthetic procedure will be translated to other metal ions to study their impact on interfacial radiolysis.

08 - HYDROGEN↗

Procedure Parsing: A Method for Parsing Handwritten Documents into Computer-Based Procedures

The nuclear industry is heavily procedure driven, where almost everything has a step-by-step instruction that is expected to be followed in detail. Historically, these procedures were printed on paper copies. Recently, the industry transitioned towards electronic copies (i.e., PDFs on tablets). One major drive for this transition is the introduction of human error and loss of situation awareness when using paper copies. However, electronic copies of documents inherently have the same error traps as their paper cousins. Therefore, there is an increased interest in a way to utilize the information in the step-by-step guidance, but to present it in a dynamic manner that guides the user and adapts to any encountered conditions. Researchers at Idaho National Laboratory propose a flexible, automated method based on document parsing and augmented by natural language processing (NLP) techniques, to address these shortcomings and capitalize on these recent advancements in machine learning. The proposed method provides a cost-effective solution for computer-assisted procedure parsing of hand-written control room procedures, originally authored in Word or PDF formats, into instructions that can be displayed as computer-based procedures (CBP) in a modern graphical user interface. The researchers devised, implemented and demonstrated the Operating Procedure Extender for Novel Systems (OPENS) method in 2020. The key to OPENS is to map the original procedure text into a context-free grammar, tying content to equipment, locations, and other steps, actions, etc. This formal grammar is then used to isolate and define keywords and actions verbs, such as “measure” or “evaluate” and tie them to specific equipment referenced within that step or located in other steps, substeps, actions, subactions and tables throughout the procedure. OPENS generates an abstract syntax tree from the document which it uses to store a copy of this information in the open-standard, machine-readable and human-readable file formats XML and JSON. The XML is useful to preserve the relational aspects of the procedure for referencing tables and branching information so the user can be directed to the next appropriate active step based on the values entered for that step and previous steps. The JSON is useful for storing and exchanging data objects used to track responses to previous steps and state changes in simulated environments. In future iterations, these formats can also be used for storing more detailed information about input during plant operation or simulation. The techniques the researcher developed could further be improved by integration of recent advancements in machine learning. NLP methods could standardize documents, correct for grammatical error, and provide automated semantic validation. The researcher expects that self-supervised techniques applied to collections of natural language instructions could strengthen the model with broader context. All these methods together give us a practical way to automatically extract protocols from documents and user interactions, empowering researchers, procedure writers and nuclear operators while moving the industry forward.

99 GENERAL AND MISCELLANEOUS↗

Apollo Experiment Report: Lunar-Sample Processing in the Lunar Receiving Laboratory High-Vacuum Complex

A high-vacuum complex composed of an atmospheric decontamination system, sample-processing chambers, storage chambers, and a transfer system was built to process and examine lunar material while maintaining quarantine status. Problems identified, equipment modifications, and procedure changes made for Apollo 11 and 12 sample processing are presented. The sample processing experiences indicate that only a few operating personnel are required to process the sample efficiently, safely, and rapidly in the high-vacuum complex. The high-vacuum complex was designed to handle the many contingencies, both quarantine and scientific, associated with handling an unknown entity such as the lunar sample. Lunar sample handling necessitated a complex system that could not respond rapidly to changing scientific requirements as the characteristics of the lunar sample were better defined. Although the complex successfully handled the processing of Apollo 11 and 12 lunar samples, the scientific requirement for vacuum samples was deleted after the Apollo 12 mission just as the vacuum system was reaching its full potential.

White, D. R.↗

Building a Simplistic Automatic Extruder: Instrument Development Opportunities for the Laboratory

This work presents an automatic extruder as a research experience for undergraduate students. The system offers a user-friendly approach to preparing vesicles, such as liposomes or polymersomes, with a defined size and polydispersity properties crucial for research in biology and macromolecules. It comprises two syringe pumps connected by a membrane filter. The setup is controlled by software. Compared to manual extrusion, this automated system provides advantages, such as precisely controlled variables. The project describes a tool to enhance undergraduate learning in science and engineering laboratories. Building an automatic extruder serves as a simplified model of a complex industrial process. It offers a clear advantage: automating a well-understood manual extrusion process. To make this project accessible, it is broken down into three manageable tasks: software development, hardware assembly, and testing procedures. This breakdown describes the software created, the hardware components used, and the testing procedures conducted for this project. All project data, including software code, testing data, and procedures, are freely available online. This allows undergraduate students to not only begin their own projects but also contribute to this educational instrument’s ongoing development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Review of the Lawrence Livermore Nuclear Accident Dosimeter 1980s-present

A Nuclear Accident Dosimetry program is a federal requirement for all facilities that have the potential to have a criticality accident. Personnel Nuclear Accident Dosimeter (PNAD) theory and analytical procedures are driven by various scientific needs and interacting regulations. A brief history of the status of USA Department of Energy (DOE) nuclear accident dosimetry regulations, recommendations, and performance testing criteria are given. Then, the history of the Lawrence Livermore National Laboratory (LLNL) PNAD is explored, including changes in the physical dosimeter and adjustments of the analysis method through the last four decades. Finally, the performance of LLNL’s PNAD at criticality accident intercomparison training exercises since 2009 is explored. In general, reported neutron doses have been within or close to DOE-STD-1098 performance criteria while reported gamma doses have been outside of DOE-STD-1098 performance criteria. Reported total absorbed doses have varied in meeting ANSI/HPS N13.3 and ANSI/HPS N13.3 (R2019) performance criteria. Dosimetry staff retirement and turnover have left historical knowledge gaps, yet provided opportunities within the NAD program at LLNL. This review paper serves as an overview of the history and status of the NAD program. Brief technical, procedural and programmatic recommendations to improve LLNL’s NAD program are given. Technical recommendations include investigating orientation factors through modeling or empirical experimentation, investigating gamma dosimetry methods for high-dose scenarios, and exploring other dosimetric methods for simpler, quicker NAD analysis. Procedural recommendations include better documentation of conversion factor (activity-to-fluence and fluence-to-dose) derivations and spectrum uses, and updated analysis spreadsheets or simple Graphic User Interfaces for dose calculations. In conclusion, programmatic recommendations include formalized training for NAD analysts, and having multiple SMEs trained on the NAD program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct determination of the morphology, structure and composition of cometary and interstellar ice analogs in the laboratory

Ices of various kinds (H2O, CO, CO2, CH4, NH3, CH3OH, etc.) comprise a volumetrically significant proportion of objects in the solar system (comets, outer planets, planetary rings, satellites) as well as in interstellar space (astrophysical ices). The refinement of analytical electron microscopy (AEM) procedures for storing, preparing and analyzing ices and other materials at cryogenic temperatures is discussed. These procedures will be essential to the successful analysis of returned comet nucleus samples.

Blake, D. F.↗

TWF Waste Container Intra-Facility Transfer and Outgoing Shipment

This procedure provides instructions for the inspection and transfer of Transuranic (TRU) Waste containers within the Transuranic Waste Facility (TWF) (Waste Storage Buildings [WSBs], Characterization Waste Storage Building [CWSB]) and Characterization Trailers. This also includes the preparation to transfer to other LANL facilities. Performance of this procedure meets the requirements of SR 4.2.1.1, 4.2.1.2, 4.2.1.4, 4.2.1.5, 4.3.4.1, SAC 5.9.1, SAC 5.9.3 and AC 5.8.13 2nd bullet, as well as requirements set forth in the Los Alamos National Laboratory (LANL) Hazardous Waste Facility Permit (HWFP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrodeposition method development for Californium Rare Isotope Breeder Upgrade (CARIBU) Source

Electrodeposition is one of the most widely utilized techniques for thin-film production with high yields. Although it is used extensively, this technique still presents several issues limiting its usefulness, including excess thickness and frequent cracking of deposited films. Efforts to improve thin-film production recently undertaken at Oak Ridge Laboratory by the authors have included studying operating conditions and applied electrolytes. Samarium was used as a surrogate material for californium, and yield was compared with different deposition condition. The final procedure from the optimized condition will be applied during production of the californium-252 source for the Californium Rare Isotope Breeder Upgrade (CARIBU) project, and the fission fragment will be analyzed.

07 ISOTOPE AND RADIATION SOURCES↗

Rapid analytical determination of glutaraldehyde concentrations

Technique utilizes the iodimetric procedure which adds unknown excess of bisulfite to glutaraldehyde /GA/ then titrates unreacted bisulfite with standard iodine isotope to determine GA concentrations. Technique may interest microscopists, food researchers, biochemical or medical laboratories, and drug manufacturers.

Frigerio, N. A.↗