Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Irradiance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Weldability of irradiated Stainless Steel 304 materials harvested from the National Research Universal (NRU) reactor

In this work, the weldability of the neutron-irradiated Stainless Steel 304 (SS 304) materials containing estimated helium levels of 12 to 44 appm has been studied through a Collaborative Research and Development Agreement between the Canadian Nuclear Laboratories and Oak Ridge National Laboratory. The work utilizes a SS 304 component harvested from the National Research Universal reactor. Laser beam welding was used to explore suitable welding conditions and associated parameters, to determine helium concentration limits for successful welding of irradiated stainless-steels. The experimental results show that maximum fusion zone void sizes, fusion zone void quantity and total heat affected zone helium-induced crack length generally increased with increasing He levels and effective weld heat input. A proper combination of welding parameters with low effective heat input, such as, laser power, weld travel speed and wire feed speed, were shown to improve the welding quality, and potentially reduce the length and probability of the formation of grain boundary helium-induced cracking and voids of irradiated SS 304 even with He concentrations as high as about 44 appm.

36 MATERIALS SCIENCE↗

Irradiation response of innovatively engineered metastable TRIP high entropy alloy

For this work, properties and radiation responses of a metastable high alloy (HEA) exhibiting the transformation induced plasticity (TRIP) effect were studied. Innovative engineering used to manufacture this HEA has shown superior mechanical and corrosion properties in 3.5% NaCl than most advanced stainless steels. The microstructural evolution and corresponding mechanical response after irradiation have been evaluated using detailed transmission electron microscopy, and nanoindentation. The study shows a change in metastability of the alloy with irradiation via a recovery mechanism, where the irradiation-induced transformation is reversed by the temperature-induced transformation, thereby introducing the concept of self-healing, made possible due to the TRIP behavior of HEA.

36 MATERIALS SCIENCE↗

Understanding the effect of specimen size on the properties of fine-grain isotropic nuclear graphite for irradiation studies: Mechanical properties

Programs at Oak Ridge National Laboratory are investigating the effects of neutron irradiation in the High Flux Isotope Reactor (HFIR) on properties of fine-grain isotropic nuclear graphites. Specimens were irradiated in the HFIR flux trap, which requires using specimens that are smaller than the sizes recommended by ASTM standards. Here, this work has investigated whether subsized specimens can be used to reliably predict strength behavior. The results show that (1) tensile strength was loosely coupled to specimen volume, (2) the compression specimens had a slightly higher strength for larger volumes, (3) the uniaxial flexural strength was nearly independent of specimen effective area for one orientation whereas the other orientation showed a slight strength–size scaling Weibull behavior, and (4) equibiaxial flexural strength followed traditional strength–size scaling Weibull behavior. These results suggest that fine-grain graphite is more similar to ceramics than to medium- and large-grained graphite with respect to both the strength-limiting flaws (Griffith theory) and the effect of machining on the strength behavior. This work shows that using specimens that are smaller than ASTM recommendations are suitable for investigating the strength changes caused by neutron irradiation because the primary interest is the relative change in the strength distribution parameters rather than their absolute values.

36 MATERIALS SCIENCE↗

Transmission electron microscopy investigation of phase transformation and fuel constituent redistribution in neutron irradiated U-10wt.%Zr fuel

Uranium-10wt.%zirconium (U-10wt.%Zr) is a primary candidate for fast reactor nuclear fuels. However, there is a lack of data characterizing neutron irradiated crystallographic phases and chemistry. In the current study, the microstructural evolution of a U-10wt.%Zr fuel neutron irradiated to a burnup of 5.7 at.% was investigated by scanning transmission electron microscopy, energy dispersive spectroscopy, and selected area electron diffraction to determine the major phases, alterations in microstructure, and variations in local chemical composition at different localities of a fuel cross-section. The current study revealed that the irradiated U-10wt.%Zr fuel was comprised of various major phases, including a-U, ß-U, and d-UZr2, as well as amorphous and crystalline solid fission product (FP) precipitates within different regions of the fuel cross-section. Regions A and A/B in the center of the fuel were comprised of U-rich, U-intermediate, and U-lean localities with a-U and d-UZr 2 composing the major phases. Regions B and C in the intermediate and peripheral fuel localities, respectively, were comprised of a-U grains, U-rich (ß-U) grains with Zr-rich precipitates, U-intermediate grains (d-UZr2), and solid FP precipitates. The major phases identified were associated with the nanoscopic chemical concentrations, the phase diagram, and the as-characterized specimen temperature, with the exception of the non-equilibrium ß-U phase identified in region B. The U-lean localities in regions A, A/B, B, and C were Zr-enriched pathways along subgrain/grain boundaries. This phenomenon suggests that Zr is susceptible to radiation-induced segregation in U-Zr fuels and indicates a new mechanism for constituent redistribution.

36 MATERIALS SCIENCE↗

The effect of secondary phases on microstructure and irradiation damage in an as-built additively manufactured 316 L stainless steel with a hafnium compositional gradient

Additive manufacturing (AM) or rapid prototyping has become a crucial tool for reducing both cost and time while increasing efficiency in qualifying structural materials for reactor use. In this study, directed energy deposition (DED) was used to develop an as-built 316 L stainless steel sample with three regions of increasing Hf-dopant to study the effects of Hf on the irradiation response of the material. Morphological and microstructural changes were analyzed before and after 2 MeV proton irradiation at 360 °C to a damage of 2.5 dpa at ~ 10 µm below the surface. The addition of Hf effectively suppressed radiation-induced damage (dislocation loops, radiation-induced segregation) due to enhanced point defect recombination. The radiation damage seen in the as-built sample was further compared to a thermo-mechanically treated counterpart of the same fabrication and irradiation parameters which was found to behave superiorly. In conclusion, the increased radiation resistance of this material may be attributed to the as-built microstructure, which includes undissolved Hf particles, delta ferrite grains and cellular sub-grain boundaries that can hinder defect motion.

316L Stainless Steel↗

Post-irradiation examination of UN-Mo-W fuels for space nuclear propulsion

The National Aeronautics and Space Administration's return to space nuclear propulsion stems from the need for a more efficient method of space travel. Nuclear thermal propulsion systems have been shown to be two times more efficient than chemical propulsion. NASA's Sirius program was created to fabricate and test fuels for space nuclear propulsion, specifically to determine their performance under prototypical startup conditions. The Sirius project featured 4 test capsules, Sirius-1 featured uranium nitride fuel dispersed in a matrix of tungsten and rhenium, while Sirius-2A, -2B, and -3 featured uranium nitride-molybdenum-tungsten fuel (UN-Mo-W). This study discusses the Sirius-2A and -2B irradiation experiments at the Idaho National Laboratory, specifically their performance under irradiation at the Transient Reactor Test Facility. It was found that the fuel samples overall did not exhibit significant cracking, though the Sirius-2A fuel did have one large crack on the surface of the fuel. There was minimal hydrogen absorption in the samples, though it is unknown if the absorption occurred during irradiation or during fabrication. Mechanical testing indicated that the UN fuel demonstrated ceramic behavior as expected, and the Mo/W matrix demonstrated linear elastic behavior to failure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser repair welding of irradiated alloy 182

Welding repair of irradiated nickel-based alloys, such as Alloy 182, poses a significant challenge due to helium-induced cracking (HeIC) and grain boundary degradation (GBD) in the heat affected zone, driven by helium accumulation at grain boundaries and welding-induced tensile stresses. This study investigates the weldability of irradiated Alloy 182 up to 15 wppm doped boron using both conventional laser welding and the Auxiliary Beam Stress Improved (ABSI) laser welding technique. While HeIC was observed at the weld toe of the entry pass in both methods due to the higher effective heat input associated with the initial pass directly on the base metal, no additional cracking occurred elsewhere, even at elevated helium concentrations. Optical and scanning electron microscopy analysis revealed that the ABSI technique, which introduces additional compressive stresses to counteract solidification-induced tensile stresses, significantly reduced GBD formation, lowering its total count from 1,230 to 339 and decreasing both average and maximum GBD lengths. In conclusion, these results demonstrate that the ABSI technique is a promising approach to mitigate helium-induced damage and improve the weldability of irradiated Alloy 182, offering a viable solution for structural repairs for long-term operation of existing nuclear reactors.

grain boundary degradation↗

Mechanisms of stored energy release in silicon carbide materials neutron-irradiated at elevated temperatures

Understanding the stored energy release behavior of SiC is crucial for the design of SiC-based fuel cladding for light water reactors because stored energy release affects response during accident conditions. Differential scanning calorimetry was used to evaluate the stored energy of monolithic SiC and SiC fiber–reinforced SiC matrix composite variants following neutron irradiation under light water reactor–relevant dose and temperature conditions. The tests were performed at heating rates of 0.5, 3, and 20 K/min up to 1,273 K. The onset temperature of the energy release roughly corresponded to the irradiation temperature, and energy release was delayed as the heating rate increased. The monolithic and composite specimens exhibited similar stored energy release behavior up to ~1,000 K, and above that temperature, the energy release depended more on material type. The energy release measured in this study is below the material-specific heat capacity at temperatures below ~1,000 K but exceeds it under certain material and annealing conditions at temperatures above ~1,000 K. The amount of irradiation-induced volumetric swelling of the specimens was an indication of the total stored energy. Based on this observation, the energy release behavior was described by a swelling recovery model.

36 MATERIALS SCIENCE↗

Analysis of position-dependent cavity parameters in irradiated metals to obtain insight on fundamental defect migration phenomena

Motion of point defects is a fundamental process that governs microstructure and properties of materials. Here, we examine the near-surface and grain boundary cavity swelling depth profiles in neutron- and ion-irradiated simple metals (Cu, Ni, and Fe-Cr) and investigate diffusional broadening of implanted Ni ions in Fe-Cr alloys. Vacancy migration energies and radiation-enhanced diffusion were experimentally estimated. Cavity denuded zone widths near planar sinks are shown to be dependent on temperature, damage rate, balance of point defects and sinks, and vacancy migration energies. An enhanced cavity swelling zone adjacent to the void-denuded zone was observed in specimens with low to moderate sink strength and interpreted as evidence of 1D gliding interstitial clusters. Radiation-enhanced diffusional broadening of implanted Ni ions (at 400–550 °C) in Fe and Fe-Cr was up to 250 nm toward the surface, which leads to a much broader near-peak-damage region where cavity swelling is suppressed. Diffusional broadening of implanted ions is calculated to be similarly pronounced for self-ion irradiations, particularly near the peak and higher swelling temperature regimes. Adequately high ion energies (~8–15 MeV) are recommended for ion-irradiation studies to provide a sufficiently broad midrange safe analysis region with minimized surface and injected ion effects.

36 MATERIALS SCIENCE↗

Synergistic Effects of Molten Salt Corrosion and Proton Irradiation on Grain Boundary Strength in Ni-20Cr

Nickel-based alloys are leading contenders for use as structural materials in molten salt reactors. While there have been extensive studies on the impact of fluoride/chloride-based molten salt corrosion on the microstructural evolution of various nickel-based alloys, the effects of simultaneous molten salt corrosion and radiation on the mechanical integrity of grain boundaries (GBs) remain underexplored. In this study, we use a Ni-20Cr model alloy to investigate this issue, subjecting it to simultaneous molten fluoride salt corrosion and proton irradiation. We performed cross-sectional and chemically-sensitive electron microscopy characterization of the microstructures of these materials, identifying the characteristic corrosion-induced microstructure and local chemical heterogeneity near GBs. After developing a sample preparation method for reliable characterization of GB strength, we assess the mechanical degradation of GBs using in situ push-to-pull micro tensile tests. Our findings reveal that voids induced by corrosion are the primary influence on the failure mode of GBs, regardless of whether proton irradiation is present. For materials that exhibit ductile fracture, those subjected to simultaneous corrosion and radiation exhibit lower yield strengths than those exposed to corrosion alone, which may be linked to the previously observed phenomenon of proton irradiation-decelerated intergranular corrosion in molten salt.

36 - MATERIALS SCIENCE↗

Response of the Verwey transition in magnetite to controlled point-like disorder induced by 2.5 MeV electron irradiation

Controlled point-like disorder induced by low temperature 2.5 MeV electron irradiation was used to probe the nature of the Verwey transition in magnetite, Fe 3 O 4 . Two large single crystals, one with optimal transition temperature, T V ≈ 121 K, and another with T V ≈ 109 K, as well as magnetite magnetosome nanocrystals harvested from the lysed cells of the marine magnetotactic vibrio Magnetovibrio blakemorei strain MV-1, T V ≈ 110 K, were examined. Temperature-dependent resistivity is consistent with the semiconductor-to-semiconductor (insulator) sharp, step-like Verwey transition from a state with a small bandgap of around 60 meV to a state with a large bandgap of about 300 meV. The irradiation causes an up-shift of the resistivity curves above the transition without transition smearing or broadening. It also causes an apparent down-shift of the resistivity maximum at high temperatures. In the lower crystal, the electron irradiation drives the transition temperature into a “forbidden” interval of T V , believed to separate the first order from the second order phase transition. Contrary to this belief, the transition itself remains sharp and hysteretic without a significant change in the hysteresis width indicating the strong 1st order character of the Verwey transition for all TV values. The separate 2nd order - looking transition is likely due to sample inhomogeneities. Here we conclude that the sudden change of the bandgap accompanied (or driven) by the monoclinic distortion and the change of magnetic anisotropy is the reason for the Verwey transition in magnetite and the effect of additional disorder is mostly in the smearing of the sharp gap edges near the Fermi level.

36 MATERIALS SCIENCE↗

Design and commissioning of an e-beam irradiation beamline at the Upgraded Injector Test Facility at Jefferson Lab

We report the Upgraded Injector Test Facility (UITF) at Jefferson Lab is a continuous-wave superconducting linear accelerator capable of providing an electron beam with energy up to 10 MeV. A beamline for electron-beam irradiation has been designed, installed and successfully commissioned at this facility, aimed at the degradation study of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) in wastewater treatment. A solenoid with a peak axial magnetic field of up to 0.28 T and a set of raster coils were used to obtain a Gaussian beam profile with a transverse standard deviation of ~ 15.0 mm at the target location. Monte-Carlo simulations using FLUKA were carried out to calculate the total absorbed dose and the dose distribution in the sample volume inside the target cell. The simulations were benchmarked experimentally by dosimetry mapping using optichromic dosimeters. The results of the irradiation experiments showed a ~ 95% reduction of 1,4-dioxane in ultra-pure water for a dose of 1 kGy, demonstrating the potential of electron-beam irradiation towards addressing growing challenges in environmental remediation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The porosity surrounding carbides and second phase stringers in monolithic U-10Mo fuel plate after irradiation

Post-irradiation microstructure characterization plays an important role in qualifying the low-enriched uranium (LEU) monolithic U-10 wt%Mo plate-type fuel for United States high-performance research reactors (USHPRRs) program. Inhomogeneous features resulting from manufacturing and irradiation processes, including carbides, second phase stringers, and extensive void spaces caused by the combining of small porosities, may increase the risk of heat concentration in local regions of the fuel plate over the operating conditions. In this study, characteristics of carbides, stringers, and porosity after multiple levels of irradiation at varying fission densities were studied by electron microscopes to decipher the morphology of pores and the porosity evolution in U-10 wt%Mo. For carbides, the result shows that porosities start forming on UMo grain boundaries, then on UMo/carbides interfaces as the burn-up going higher. However, the porosities surrounding carbides grow larger than the ones on UMo grain boundaries. The porosities around the uranium carbides could interconnect to form larger void space. The study revealed that the void spaces larger than 5 µm were found around uranium carbides after high burnup, while no evidence was observed to support the similar voids formed near second phase stringers even though the size of the stringers (> 50 µm) was much larger than uranium carbides (< 20 µm). The evolution of porosities suggests that the formation of second phase stringers may not create more significant porosities compared to regular uranium carbides regions during fuel operating conditions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microscopic analysis of irradiated UN–Mo–W for space nuclear propulsion

Nuclear propulsion is an effective method of providing thrust in deep space, allowing for shorter mission duration for long-term surface missions to Mars. The fuel for nuclear propulsion systems must exhibit superior mechanical and thermal properties, to decrease the possibility of fuel failure and to increase reactor efficiency. Here, the objective of the Sirius project is to fabricate and irradiate cermet fuels at the Idaho National Laboratory Transient Reactor Facility to determine the properties of the fuel after irradiation at prototypical nuclear propulsion start-up conditions. The Sirius project featured 3 test capsules, Sirius-1 featured uranium nitride fuel dispersed in a matrix of tungsten and rhenium, while Sirius-2A and -2B featured uranium nitride-molybdenum-tungsten fuel (UN-Mo-W). The fuel samples from the Sirius-2A and -2B capsules were examined after irradiation using optical microscopy, scanning electron microscopy, and X-ray diffraction analyses. The mechanical properties of the fuel from Sirius-2A and -2B are discussed in a previous work. In this study, the results of the optical microscopy, scanning electron microscopy, and X-ray diffraction analyses are discussed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

London penetration depth of electron-irradiated Ba 0 . 47 K 0 . 53 Fe 2 As 2

We have characterized an electron-irradiated Ba 1-x K x Fe 2 As 2 (x = 0.53) single-crystal using two different experimental techniques: magneto-optic measurements and microwave measurements. The crystal has been measured before as well as after the 2.5 MeV electron irradiation process. After irradiation it was annealed in a number of steps, between 90 °C and 180 °C, and measured after each annealing step. Most microwave measurements were performed by means of a copper cavity, taking advantage of the TE 011 and TM 110 modes, allowing for the determination of the London penetration depths changes δλ ab (T) and δλ c (T), ie perpendicular and parallel to the sample c-axis. Appropriate equations, based on perturbation theory, were derived to calculate the penetration depths changes δλ ab and δλ c for a rectangular prism geometry. The sample showed a full recovery of its T c , however the observed behavior of δλ c and δλ ab was not monotonic vs annealing temperature, displaying a minimum of δλ c and δλ ab at 120 °C. In conclusion, this finding was confirmed by magneto-optic measurements, where besides verifying the sample uniformity and the absence of visible defects, the lower critical field H c1 of the Ba 1-x K x Fe 2 As 2 single-crystal was obtained and the London penetration depth λab(0) was calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of a first-of-A-kind instrumented advanced test reactor irradiation Capsule experiment for In situ thermal conductivity measurements of metallic fuel

Metallic fuel undergoes dramatic microstructural changes early in life due to fission gas swelling until ~2–3 at% burnup which affects the conductivity of the material, however the evolution of metallic fuel thermal conductivity during this early phase burnup has never been successfully measured in situ. The Irradiated Material Properties Accelerated Characterization Test (IMPACT) experiment will be the first in a series of experiments to irradiate advanced nuclear metallic fuel specimens with novel embedded thermal conductivity probes in ATR. In the current work the IMPACT experiment final design and supporting analysis is reported in detail. Results are evaluated for various reactor operational conditions to meet the functional requirements of the experiment. Finally, the first iteration of this IMPACT experiment will provide data regarding thermal properties evolution in uranium-zirconium (U10Zr) fuel, but this experiment vehicle is envisioned for future advanced fuels and structural materials irradiations in ATR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact X-band split electron linac for cabinet-size small-sample irradiators

Many small-scale industrial radiation facilities rely on hazardous radioisotope-based gamma ray irradiators, which are being gradually replaced by alternative technologies, such as particle accelerators. RadiaBeam has developed a compact, cabinet-size, 3 MeV electron-linac-based irradiator to match the penetration of Co-60 and provide high irradiation throughput. Here the linac utilizes X-band RF power to reduce size, employs an innovative split-linac approach to lower costs, and features a novel X-ray conversion target geometry that spreads the beam out across the target, providing a low dose uniformity ratio. In this paper, we discuss the accelerator design, fabrication, and test results.

43 PARTICLE ACCELERATORS↗