Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation Set Points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method are of two types: foil and fiber-optic. Four foil gauges and one or more fiber-optic gauges are mounted on each of the tank-supporting legs. An additional fiber-optic gauge is mounted on an object, made of the same material as that of the tank-supporting legs, that is not subjected to any mechanical load. The reading obtained by the additional fiber-optic gauge is used to compensate for apparent strains caused by changes in temperature. The signals from the foil and fiber-optic gauges are conditioned, then digitized for input to a computer. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. At the time of reporting the information for this article, a set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 microstrain) that occurred during filling and emptying the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. It has been estimated that once the fiber-optic gauges are put into operation, it should be possible to determine fluid masses with 3 percent or less. It may be possible to increase accuracy further by increasing the signal-to-noise ratio through the use of more deformable tank supporting legs.

Figueroa, Jorge↗

Aeroheating Testing and Predictions for Project Orion CEV at Turbulent Conditions

An investigation of the aeroheating environment of the Project Orion Crew Exploration Vehicle was performed in the Arnold Engineering Development Center Hypervelocity Wind Tunnel No. 9 Mach 8 and Mach 10 nozzles and in the NASA Langley Research Center 20 - Inch Mach 6 Air Tunnel. Heating data were obtained using a thermocouple-instrumented approx.0.035-scale model (0.1778-m/7-inch diameter) of the flight vehicle. Runs were performed in the Tunnel 9 Mach 10 nozzle at free stream unit Reynolds numbers of 1x10(exp 6)/ft to 20x10(exp 6)/ft, in the Tunnel 9 Mach 8 nozzle at free stream unit Reynolds numbers of 8 x 10(exp 6)/ft to 48x10(exp 6)/ft, and in the 20-Inch Mach 6 Air Tunnel at free stream unit Reynolds numbers of 1x10(exp 6)/ft to 7x10(exp 6)/ft. In both facilities, enthalpy levels were low and the test gas (N2 in Tunnel 9 and air in the 20-Inch Mach 6) behaved as a perfect-gas. These test conditions produced laminar, transitional and turbulent data in the Tunnel 9 Mach 10 nozzle, transitional and turbulent data in the Tunnel 9 Mach 8 nozzle, and laminar and transitional data in the 20- Inch Mach 6 Air Tunnel. Laminar and turbulent predictions were generated for all wind tunnel test conditions and comparisons were performed with the experimental data to help define the accuracy of computational method. In general, it was found that both laminar data and predictions, and turbulent data and predictions, agreed to within less than the estimated 12% experimental uncertainty estimate. Laminar heating distributions from all three data sets were shown to correlate well and demonstrated Reynolds numbers independence when expressed in terms of the Stanton number based on adiabatic wall-recovery enthalpy. Transition onset locations on the leeside centerline were determined from the data and correlated in terms of boundary-layer parameters. Finally turbulent heating augmentation ratios were determined for several body-point locations and correlated in terms of the boundary-layer momentum Reynolds number.

Hollis, Brian R.↗

TU-AB-BRA-12: Quality Assurance of An Integrated Magnetic Resonance Image Guided Adaptive Radiotherapy Machine Using Cherenkov Imaging

Purpose: To investigate the viability of using Cherenkov imaging as a fast and robust method for quality assurance tests in the presence of a magnetic field, where other instruments can be limited. Methods: Water tank measurements were acquired from a clinically utilized adaptive magnetic resonance image guided radiation therapy (MR-IGRT) machine with three multileaf-collimator equipped 60Co sources. Cherenkov imaging used an intensified charge coupled device (ICCD) camera placed 3.5m from the treatment isocenter, looking down the bore of the 0.35T MRI into a water tank. Images were post-processed to make quantitative comparison between Cherenkov light intensity with both film and treatment planning system predictions, in terms of percent depth dose curves as well as lateral beam profile measurements. A TG-119 commissioning test plan (C4: C-Shape) was imaged in real-time at 6.33 frames per second to investigate the temporal and spatial resolution of the Cherenkov imaging technique. Results: A .33mm/pixel Cherenkov image resolution was achieved across 1024×1024 pixels in this setup. Analysis of the Cherenkov image of a 10.5×10.5cm treatment beam in the water tank successfully measured the beam width at the depth of maximum dose within 1.2% of the film measurement at the same point. The percent depth dose curve for the same beam was on average within 2% of ionization chamber measurements for corresponding depths between 3–100mm. Cherenkov video of the TG-119 test plan provided qualitative agreement with the treatment planning system dose predictions, and a novel temporal verification of the treatment. Conclusions: Cherenkov imaging was successfully used to make QA measurements of percent depth dose curves and cross beam profiles of MRI-IGRT radiotherapy machines after only several seconds of beam-on time and data capture; both curves were extracted from the same data set. Video-rate imaging of a dynamic treatment plan provided new information regarding temporal dose deposition. This study has been funded by NIH grants R21EB17559 and R01CA109558, as well as Norris Cotton Cancer Center Pilot funding.

60 APPLIED LIFE SCIENCES↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

arc-jet↗

Recommendations for Minimum Required Error Codes for Electric Vehicle Charging Infrastructure

OCPP protocol manages the interaction between the EVSE and its respective back-end communication network. It plays a pivotal role in both error reporting and troubleshooting, carried out primarily through the CSMS. OCPP defines both standard error codes and a flexible framework for creating and communicating custom error codes. The OCPI protocol orchestrates the communication between different backhaul communication networks, incorporating the exchange of error codes. These error codes are instrumental in pinpointing and rectifying issues that can surface prior to, during, or after charging operations, fortifying the reliability and resilience of the EV charging infrastructure. The flexibility offered by the OCPP and OCPI frameworks through the introduction of custom error codes also creates its own set of challenges. While the integration of custom error codes allows for enhanced granularity, it also introduces inconsistencies and fragmentation within the overarching diagnostic reporting system. To address the challenges with custom error codes this report proposes a set of Minimum Required Error Codes (MRECs) for streamlined error reporting, interpretability, and diagnostics. Recommendations in this report are based on independent analysis of custom error codes from multiple stakeholders within the EV charging ecosystem. For better error resolution, this report also assigns one or more entities responsible for the resolution of every mentioned error code. Finally, a functional classification for each mentioned error code is also identified to describe the nature of the error. In summary, the purpose of this document is to simplify the troubleshooting process and increase charging reliability for all EV users. This report serves as a recommendation for industry stakeholders, encouraging a unified methodology to define, transmit, and interpret common error codes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NIAC Swarm Flyby Gravimetry Phase II Report

This NASA Innovative Advanced Concept (NIAC) grant has enabled the research and development of a method for conducting small body gravimetry from a spacecraft, using relative measurements to a set of deployed test-masses. The test-masses are tracked from a host spacecraft, which dispenses them near to the small body's surface. Thanks to this close proximity, the probes' orbits can be highly perturbed, which yields useful gravimetric measurements. The most readily achievable approach for tracking the probes is to use an optical instrument on- board the spacecraft. The probes then need only be reflective to sunlight. This implementation, called optical gravimetry (OpGrav), has the fewest requirements for the host spacecraft and probes.The results of this study indicate that OpGrav is feasible and offers meaningful improvement over existing methods. Parametric studies suggest roughly an order of magnitude improvement in accuracy or asteroid accessibility (how small an asteroid one can measure) over Earth-based Doppler-only mass estimation. This exponentially expands the number of potential near-Earth objects that one could study, which has implications for planetary defense.As a sample mission, we evaluated OpGrav as an added instrument on a main- belt asteroid tour mission. In this case, simulations show that OpGrav would increase the number of asteroid mass estimates from 3 of 9 to 7 of 9. That is, OpGrav has sufficient sensitivity to offer utility in missions for which it is not explicitly designed for.We designed and fabricated a prototype hardware implementation for this concept called the Small-body In-situ Multi-probe Mass Estimation Experiment (SIMMEE). This hardware provides a basis for many inputs into the simulations and grounds the models with physical values. The primary design driver for the hardware is a long life, on the order of five years prior to operation, and a need for high pointing accuracy to enable flybys of the smallest objects.The next steps include further hardware testing and extension of the concept to rendezvous cases. We believe that this concept offers planetary scientists a new and relevant means of better understanding small-bodies.

Atchison, Justin A.↗

The overvoltage protection module for the power supply system for the pixel detector at Belle II experiment at KEK

In this paper the overvoltage protection modules (OVP) for the power supply (PS) system of the Belle II pixel detector (PXD) are described. The aim of the OVP is to protect the detector and associated electronics against overvoltage conditions. Most critical in the system are voltages supplying the front-end ASICs. The PXD detector consists of the DEPFET sensor modules with integrated chips like the Drain Current Digitizer, the Switcher and the Data Handling Processor. These chips, implemented in modern sub-micron technologies, are quite vulnerable to variations in the supply voltages. The PXD will be placed in the Belle II experiment as close as possible to the interaction point, where access during experiment is very limited or even impossible, thus the PS and OVP systems exploit the remote-sensing method. Overvoltage conditions are due to failures of the PS itself, wrong setting of the output voltages or transient voltages coming out of hard noisy environment of the experiment. The OVP modules are parts of the PS modules. For powering the PXD 40 PS modules are placed 15 m outside the Belle II spectrometer. Each one is equipped with the OVP board. All voltages (22) are grouped in 4 domains: Analog, Digital, Steering and Gate which have independent grounds. The OVP boards are designed from integrated circuits from Linear Technology. All configurations were simulated with the Spice program. The control electronics is designed in a Xilinx CPLD. Two types of integrated circuits were used. LT4356 surge stopper protects loads from high voltage transients. The output voltages are limited to a safe value and also protect loads against over current faults. For less critical voltages, the LTC2912 voltage monitors are used that detect under-voltage and overvoltage events. It has to be noted that the OVP system is working independently of any other protection of the PS system, which increases its overall reliability. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Testing of Laser-induced Breakdown Spectroscopy for the Mars Rover Program: Elemental Analyses at Stand-Off Distances

One of the most fundamental pieces of information about any planetary body is the elemental composition of its surface materials. The Viking Martian landers employed XRF (x-ray fluorescence) and the MER rovers are carrying APXS (alpha-proton x-ray spectrometer) instruments upgraded from that used on the Pathfinder rover to supply elemental composition information for soils and rocks to which direct contact is possible. These in- situ analyses require that the lander or rover be in contact with the sample. In addition to in-situ instrumentation, the present generation of rovers carry instruments that operate at stand-off distances. The Mini-TES is an example of a stand-off instrument on the MER rovers. Other examples for future missions include infrared point spectrometers and microscopic-imagers that can operate at a distance. The main advantage of such types of analyses is obvious: the sensing element does not need to be in contact or even adjacent to the target sample. This opens up new sensing capabilities. For example, targets that cannot be reached by a rover due to impassable terrain or targets positioned on a cliff face can now be accessed using stand-off analysis. In addition, the duty cycle of stand-off analysis can be much greater than that provided by in-situ measurements because the stand-off analysis probe can be aimed rapidly at different features of interest eliminating the need for the rover to actually move to the target. Over the past five years we have been developing a stand-off method of elemental analysis based on atomic emission spectroscopy called laser-induced breakdown spectroscopy (LIBS). A laser-produced spark vaporizes and excites the target material, the elements of which emit at characteristic wavelengths. Using this method, material can be analyzed from within a radius of several tens of meters from the instrument platform. A relatively large area can therefore be sampled from a simple lander without requiring a rover or sampling arms. The placement of such an instrument on a rover would allow the sampling of locations distant from the landing site. Here we give a description of the LIBS method and its advantages. We discuss recent work on determining its characteristics for Mars exploration, including accuracy, detection limits, and suitability for determining the presence of water ice and hydrated minerals. We also give a description of prototype instruments we have tested in field settings.

D A Cremers↗

Examination of Liquid Fluoride Salt Heat Transfer

The need for high efficiency power conversion and energy transport systems is increasing as world energy use continues to increase, petroleum supplies decrease, and global warming concerns become more prevalent. There are few heat transport fluids capable of operating above about 600oC that do not require operation at extremely high pressures. Liquid fluoride salts are an exception to that limitation. Fluoride salts have very high boiling points, can operate at high temperatures and low pressures and have very good heat transfer properties. They have been proposed as coolants for next generation fission reactor systems, as coolants for fusion reactor blankets, and as thermal storage media for solar power systems. In each case, these salts are used to either extract or deliver heat through heat exchange equipment, and in order to design this equipment, liquid salt heat transfer must be predicted. This paper discusses the heat transfer characteristics of liquid fluoride salts. Historically, heat transfer in fluoride salts has been assumed to be consistent with that of conventional fluids (air, water, etc.), and correlations used for predicting heat transfer performance of all fluoride salts have been the same or similar to those used for water conventional fluids an, water, etc). A review of existing liquid salt heat transfer data is presented, summarized, and evaluated on a consistent basis. Less than 10 experimental data sets have been found in the literature, with varying degrees of experimental detail and measured parameters provided. The data has been digitized and a limited database has been assembled and compared to existing heat transfer correlations. Results vary as well, with some data sets following traditional correlations; in others the comparisons are less conclusive. This is especially the case for less common salt/materials combinations, and suggests that additional heat transfer data may be needed when using specific salt eutectics in heat transfer equipment designs. All of the data discussed above were taken under forced convective conditions (both laminar and turbulent). Some recent data taken at ORNL under free convection conditions are also presented and results discussed. This data was taken using a simple crucible experiment with an instrumented nickel heater inserted in the salt to induce natural circulation within the crucible. The data was taken over a temperature range of 550oC to 650oC in FLiNaK salt. This data covers both laminar and turbulent natural convection conditions, and is compared to existing forms of natural circulation correlations.

experiments↗

Surface thermocouples for measurement of pulsed heat flux in the divertor of the Alcator C-Mod tokamak

A novel set of thermocouple sensors has been developed to measure heat fluxes arriving at divertor surfaces in the Alcator C-Mod tokamak, a magnetic confinement fusion experiment. These sensors operate in direct contact with the divertor plasma, which deposits heat fluxes in excess of {approx}10 MW/m{sup 2} over an {approx}1 s pulse. Thermoelectric EMF signals are produced across a non-standard bimetallic junction: a 50 {mu}m thick 74% tungsten-26% rhenium ribbon embedded in a 6.35 mm diameter molybdenum cylinder. The unique coaxial geometry of the sensor combined with its single-point electrical ground contact minimizes interference from the plasma/magnetic environment. Incident heat fluxes are inferred from surface temperature evolution via a 1D thermal heat transport model. For an incident heat flux of 10 MW/m{sup 2}, surface temperatures rise {approx}1000 deg. C/s, corresponding to a heat flux flowing along the local magnetic field of {approx}200 MW/m{sup 2}. Separate calorimeter sensors are used to independently confirm the derived heat fluxes by comparing total energies deposited during a plasma pulse. Langmuir probes in close proximity to the surface thermocouples are used to test plasma-sheath heat transmission theory and to identify potential sources of discrepancies among physical models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PANCHROMATIC OBSERVATIONS OF SN 2011dh POINT TO A COMPACT PROGENITOR STAR

We report the discovery and detailed monitoring of X-ray emission associated with the Type IIb SN 2011dh using data from the Swift and Chandra satellites, placing it among the best-studied X-ray supernovae (SNe) to date. We further present millimeter and radio data obtained with the Submillimeter Array, the Combined Array for Research in Millimeter-wave Astronomy, and the Expanded Very Large Array during the first three weeks after explosion. Combining these observations with early optical photometry, we show that the panchromatic data set is well described by non-thermal synchrotron emission (radio/mm) with inverse Compton scattering (X-ray) of a thermal population of optical photons. In this scenario, the shock partition fractions deviate from equipartition by a factor, ({epsilon}{sub e}/{epsilon}{sub B}) {approx} 30. We derive the properties of the shock wave and the circumstellar environment and find a time-averaged shock velocity of v-bar {approx}0.1c and a progenitor mass-loss rate of M-dot approx. 6 x 10{sup -5} M{sub Sun} yr{sup -1} (for an assumed wind velocity, v{sub w} = 1000 km s{sup -1}). We show that these properties are consistent with the sub-class of Type IIb SNe characterized by compact progenitors (Type cIIb) and dissimilar from those with extended progenitors (Type eIIb). Furthermore, we consider the early optical emission in the context of a cooling envelope model to estimate a progenitor radius of R{sub *} Almost-Equal-To 10{sup 11} cm, in line with the expectations for a Type cIIb SN. Together, these diagnostics are difficult to reconcile with the extended radius of the putative yellow supergiant progenitor star identified in archival Hubble Space Telescope observations, unless the stellar density profile is unusual. Finally, we searched for the high-energy shock breakout pulse using X-ray and gamma-ray observations obtained during the purported explosion date range. Based on the compact radius of the progenitor, we estimate that the shock breakout pulse was detectable with current instruments but likely missed due to their limited temporal/spatial coverage. Future all-sky missions will regularly detect shock breakout emission from compact SN progenitors enabling prompt follow-up observations with sensitive multi-wavelength facilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Atmospheric Transmittance Model Validation for CSP Tower Plants

In yield analysis and plant design of concentrated solar power (CSP) tower plants, increased uncertainties are caused by the mostly unknown solar attenuation between the concentrating heliostat field and the receiver on top of the tower. This attenuation is caused mainly by aerosol particles and water vapor. Various on-site measurement methods of atmospheric extinction in solar tower plants have been developed during recent years, but during resource assessment for distinct tower plant projects in-situ measurement data sets are typically not available. To overcome this lack of information, a transmittance model (TM) has been previously developed and enhanced by the authors to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity and barometric pressure measurements. Previously the model was only tested at one site. In this manuscript, the enhanced TM is validated for three sites (CIEMAT’s Plataforma Solar de Almería (PSA), Spain, Missour, Morocco (MIS) and Zagora, Morocco (ZAG)). As the strongest assumption in the TM is the vertical aerosol particle profile, three different approaches to describe the vertical profile are tested in the TM. One approach assumes a homogeneous aerosol profile up to 1 kilometer above ground, the second approach is based on LIVAS profiles obtained from Lidar measurements and the third approach uses boundary layer height (BLH) data of the European Centre for Medium-Range Weather Forecasts (ECMWF). The derived broadband transmittance for a slant range of 1 km (T 1$km$ ) time series is compared with a reference data set of on-site absorption- and broadband corrected T 1$km$ derived from meteorological optical range (MOR) measurements for the temporal period between January 2015 and November 2017. The absolute mean bias error (MBE) for the TM’s T 1$km$ using the three different aerosol profiles lies below 5% except for ZAG and one profile assumption. The MBE is close to 0 for PSA and MIS assuming a homogeneous extinction coefficient up to 1 km above ground. The root mean square error (RMSE) is around 5–6% for PSA and ZAG and around 7–8% for MIS. The TM performs better during summer months, during which more data points have been evaluated. This validation proves the applicability of the transmittance model for resource assessment at various sites. It enables the identification of a clear site with high T 1$km$ with a high accuracy and provides an estimation of the T 1$km$ for hazy sites. Thus it facilitates the decision if on-site extinction measurements are necessary. The model can be used to improve the accuracy of yield analysis of tower plants and allows the site adapted design.

14 SOLAR ENERGY↗

Design, Assembly, and Testing of a Photon Doppler Velocimetry Probe

A novel fiber-optic probe measures the velocity distribution of an imploding surface along many lines of sight. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called photon Doppler velocimetry, providing continuous time records. Within the probe, a matrix array of 56 single-mode fibers sends light through an optical relay consisting of three types of lenses. Seven sets of these relay lenses are grouped into a close-packed array allowing the interrogation of seven regions of interest. A six-faceted prism with a hole drilled into its center directs the light beams to the different regions. Several types of relay lens systems have been evaluated, including doublets and molded aspheric singlets. The optical design minimizes beam diameters and also provides excellent imaging capabilities. One of the fiber matrix arrays can be replaced by an imaging coherent bundle. This close-packed array of seven relay systems provides up to 476 beam trajectories. The pyramid prism has its six facets polished at two different angles that will vary the density of surface point coverage. Fibers in the matrix arrays are angle polished at 8{sup o} to minimize back reflections. This causes the minimum beam waist to vary along different trajectories. Precision metrology on the direction cosine trajectories is measured to satisfy environmental requirements for vibration and temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decommissioning Characterisation Through Compressive Gamma-Ray Imaging - 19308

We present the imaging results from two novel single pixel gamma-ray imaging systems, developed at ANSTO, in order to support the characterisation phase of decommissioning activities. The ability to remotely locate, identify, and quantify gamma emitting radionuclides can provide crucial information for the development of an efficient decommissioning plan. The imaging systems have been designed around the theory of compressed sensing and make use of a single spectroscopic detector and a set of dual, rotating, nested tungsten masks. The imaging system designs provide a large field of view and cover an energy range of 40 keV to 1.5 MeV. The first system has been specifically developed to image the High Flux Australian Reactor (HIFAR) reactor vessel with a hemispherical 2π field of view and provided quantitative information on the location of the gamma-ray emitting radionuclides present, whilst operating in a ∼10 Sv/h dose rate environment. The second system is a portable, high sensitivity imager with a cylindrical 360 deg. x 90 deg. field of view used for localising and identifying low to medium dose rate sources in the remaining facility infrastructure. Gamma-ray images were then accurately overlaid on optical images to allow for easy visualisation of the location of gamma emitting radionuclides. The spectroscopic gamma-ray imaging of point sources has been demonstrated with only 1/10. of the measurements normally required by traditional aperture based imaging techniques. The compressive gamma-ray imaging technique provides a novel and highly configurable spectroscopic imaging capability for applications in the nuclear industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metrology of Large Parts

As discussed in the first chapter of this book, there are many different methods to measure a part using optical technology. Chapter 2 discussed the use of machine vision to measure macroscopic features such as length and position, which was extended to the use of interferometry as a linear measurement tool in chapter 3, and laser or other trackers to find the relation of key points on large parts in chapter 4. This chapter looks at measuring large parts to optical tolerances in the sub-micron range using interferometry, ranging, and optical tools discussed in the previous chapters. The purpose of this chapter is not to discuss specific metrology tools (such as interferometers or gauges), but to describe a systems engineering approach to testing large parts. Issues such as material warpage and temperature drifts that may be insignificant when measuring a part to micron levels under a microscope, as will be discussed in later chapters, can prove to be very important when making the same measurement over a larger part. In this chapter, we will define a set of guiding principles for successfully overcoming these challenges and illustrate the application of these principles with real world examples. While these examples are drawn from specific large optical testing applications, they inform the problems associated with testing any large part to optical tolerances. Manufacturing today relies on micrometer level part performance. Fields such as energy and transportation are demanding higher tolerances to provide increased efficiencies and fuel savings. By looking at how the optics industry approaches sub-micrometer metrology, one can gain a better understanding of the metrology challenges for any larger part specified to micrometer tolerances. Testing large parts, whether optical components or precision structures, to optical tolerances is just like testing small parts, only harder. Identical with what one does for small parts, a metrologist tests large parts and optics in particular to quantify their mechanical properties (such as dimensions, mass, etc); their optical prescription or design (i.e. radius of curvature, conic constant, vertex location, size); and their full part shape. And, just as with small parts, a metrologist accomplishes these tests using distance measuring instruments such as tape measures, inside micrometers, coordinate measuring machines, distance measuring interferometers; angle measuring instruments such as theodolites, autocollimators; and surface measuring instruments including interferometers, stylus profilers, interference microscopes, photogrammetric cameras, or other tools. However, while the methodology may be similar, it is more difficult to test a large object for the simple reason that most metrologists do not have the necessary intuition. The skills used to test small parts or optics in a laboratory do not extrapolate to testing large parts in an industrial setting any more than a backyard gardener might successfully operate a farm. But first, what is a large part? A simple definition might be the part's size or diameter. For optics and diffuse surface parts alike, the driving constraint is ability to illuminate the part's surface. For reflective convex mirrors, large is typically anything greater than 1 meter. But, for refractive optics, flats or convex mirrors, large is typically greater than 0.5 meter. While a size definition is simple, it may be less than universal. A more nuanced definition might be that a large part is any component which cannot be easily tested in a standard laboratory environment, on a standard vibration isolated table using standard laboratory infrastructure. A micro-switch or a precision lens might be easily measured to nanometer levels under a microscope in a lab, but a power turbine spline or a larger telescope mirror will not fit under that microscope and may not even fit on the table.

Stahl, H. Philip↗

Non-linearity effects on the light-output calibration of light charged particles in CsI(Tl) scintillator crystals

The light output produced by light ions ( Z ≤ 4) in Csl(Tl) crystals is studied over a wide range of detected energies (E ≤ 300 MeV). Energy-light calibration data sets are obtained with the 10 cm crystals in the recently upgraded High-Resolution Array (HiRA10). We use proton recoil data from 40,48 Ca + CH 2 at 28 MeV/u, 56.6 MeV/u, 39 MeV/u and 139.8 MeV/u and data from a dedicated experiment with direct low-energy beams. We also use the punch through points of p, d, and t particles from 40,48 Ca + 56,64 Ni, 112,124 Sn collisions reactions at 139.8 MeV/u. Non-linearities, arising in particular from Tl doping and light collection effects in the CsI crystals, are found to significantly affect the light output and therefore the calibration of the detector response for light charged particles, especially the hydrogen isotopes. A new empirical parametrization of the hydrogen light output, $L(E,Z=1,A)$, is proposed to account for the observed effects. Results are found to be consistent for all 48 CsI(Tl) crystals in a cluster of 12 HiRA10 telescopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the polar neutron-imaging aperture for use at the National Ignition Facility

The installation of a neutron imaging diagnostic with a polar view at the National Ignition Facility (NIF) required design of a new aperture, an extended pinhole array (PHA). This PHA is different from the pinhole array for the existing equatorial system due to significant changes in the alignment and recording systems. The complex set of component requirements, as well as significant space constraints in its intended location, makes the design of this aperture challenging. In addition, lessons learned from development of prior apertures mandate careful aperture metrology prior to first use. This paper discusses the PHA requirements, constraints, and the final design. The PHA design is complex due to size constraints, machining precision, assembly tolerances, and design requirements. When fully assembled, the aperture is a 15 mm × 15 mm × 200 mm tungsten and gold assembly. The PHA body is made from 2 layers of tungsten and 11 layers of gold. The gold layers include 4 layers containing penumbral openings, 4 layers containing pinholes and 3 spacer layers. In total, there are 64 individual, triangular pinholes with a field of view (FOV) of 200 μm and 6 penumbral apertures. Each pinhole is pointed to a slightly different location in the target plane, making the effective FOV of this PHA a 700 μm square in the target plane. The large FOV of the PHA reduces the alignment requirements both for the PHA and the target, allowing for alignment with a laser tracking system at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗