Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Design, tuning, and blackbox optimization of laser systems

Chirped pulse amplification (CPA) and subsequent nonlinear optical (NLO) systems constitute the backbone of myriad advancements in semiconductor manufacturing, communications, biology, defense, and beyond. Accurately and efficiently modeling CPA+NLO-based laser systems is challenging because of the complex coupled processes and diverse simulation frameworks. Our modular start-to-end model unlocks the potential for exciting new optimization and inverse design approaches reliant on data-driven machine learning methods, providing a means to create tailored CPA+NLO systems unattainable with current models. To demonstrate this new, to our knowledge, technical capability, we present a study on the LCLS-II photo-injector laser, representative of a high-power and spectro-temporally non-trivial CPA+NLO system.

47 OTHER INSTRUMENTATION↗

Amplification-free nucleic acid detection with a fluorescence-based waveguide biosensor

Early detection of pathogens using nucleic acids in clinical samples often requires sensitivity at the single-copy level, which currently necessitates time-consuming and expensive nucleic acid amplification. Here, we describe 1) a redesigned flow cell in the shape of a trapezoid-subtracted geometric stadium, and 2) modified experimental procedures that allow for the measurement of sub-attomolar analytes in microliter quantities on a fluorescence-based waveguide biosensor. We verified our instrumental sensitivity with a 200-μL sample of a fluorescent streptavidin conjugate at 100 zM (100 zeptomolar, or 100·10 −21 mol L −1 ) and theoretically explored the applicability of this modified sensing platform in a sandwich immunoassay format using a Langmuir adsorption model. We present assays that demonstrate specific detection of synthetic influenza A DNA (in buffer) and RNA (in saliva) oligonucleotides at the single-copy level (200 μL at 10 zM) using a fluorescent molecular beacon. Lastly, we demonstrate detection of isolated genomic influenza A RNA at a clinically relevant concentration. This work constitutes a sensitivity improvement of over twelve orders of magnitude compared to our previous nucleic acid detection work, illustrating the significant enhancements that can be gained with optimized experimental design.

59 BASIC BIOLOGICAL SCIENCES↗

Finite element modeling of electropolishing of radio frequency dipole Nb crab cavity in hydrofluoric-sulfuric acid electrolyte

The superior performance of niobium superconducting radio frequency (SRF) cavities is achieved through meticulous surface treatment, notably via chemical electropolishing, ensuring exceptionally smooth surfaces. While this technique has been extensively employed for cylindrically symmetric structures, addressing more intricate geometries poses significant challenges in achieving uniform polishing and controlled material removal, especially when moving away from retractable cathodes. This presents a multifaceted electrochemical, thermal, and fluid dynamics conundrum. A prime example is the 197 MHz radio frequency dipole (RFD) crabbing cavity proposed for the Electron Ion Collider (EIC) project, exemplifying such complex structures. Our groundbreaking work integrates the localized oxide thickness variation, considering its impact on current distribution and Joule heating, within the framework of multi-physics modeling using the COMSOL® simulation suite. This approach was applied to a comprehensive model of the RFD cavity, allowing us to investigate optimal external cooling water flow conditions necessary for achieving desirable outcomes. In conclusion, this illustrates the increasing utility of such multi-physics codes to greatly aid in designing solutions to challenging processing requirements for increasingly complex accelerator cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A phononic interface between a superconducting quantum processor and quantum networked spin memories

We introduce a method for high-fidelity quantum state transduction between a superconducting microwave qubit and the ground state spin system of a solid-state artificial atom, mediated via an acoustic bus connected by piezoelectric transducers. Applied to present-day experimental parameters for superconducting circuit qubits and diamond silicon-vacancy centers in an optimized phononic cavity, we estimate quantum state transduction with fidelity exceeding 99% at a MHz-scale bandwidth. By combining the complementary strengths of superconducting circuit quantum computing and artificial atoms, the hybrid architecture provides high-fidelity qubit gates with long-lived quantum memory, high-fidelity measurement, large qubit number, reconfigurable qubit connectivity, and high-fidelity state and gate teleportation through optical quantum networks.

47 OTHER INSTRUMENTATION↗

Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes

Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.

47 OTHER INSTRUMENTATION↗

Precision gyroscope from the helicity of light

We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left- and right-circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting radio-frequency systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.

47 OTHER INSTRUMENTATION↗

TRANSLATE - a Monte Carlo simulation of electron transport in liquid argon

Here, the microphysics of electron and photon propagation in liquid argon is a key component of detector design and calibrations needed to construct and perform measurements within a wide range of particle physics experiments. As experiments grow in scale and complexity, and as the precision of their intended measurements increases, the development of tools to investigate important microphysics effects impacting such detectors becomes necessary. In this paper we present a new time-domain Monte Carlo simulation of electron transport in liquid argon. The simulation models the TRANSport in Liquid Argon of near-Thermal Electrons (TRANSLATE) with the aim of providing a multi-purpose software package for the study and optimization of detector environments, with a particular focus on ongoing and next generation liquid argon neutrino experiments utilizing the time projection chamber technology. TRANSLATE builds on previous work of Wojcik and Tachiya, amongst others, introducing additional processes, including ionization, thus modeling the full range of drift electron scattering interactions. The simulation is validated by benchmarking its performance with swarm parameters from data collected in experimental setups operating in gas and liquid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Design of proton deflectometry with in situ x-ray fiducial for magnetized high-energy-density systems

We report a design and implementation of proton deflectometry with an in situ reference x-ray image of a mesh to precisely measure non-uniform magnetic fields in expanding plasmas at the OMEGA and OMEGA EP laser facilities. The technique has been developed with proton and x-ray sources generated from both directly driven capsule implosions and short pulse laser–solid interactions. The accuracy of the measurement depends on the contrast of both the proton and x-ray images. Here we present numerical and analytic studies to optimize the image contrast using a variety of mesh materials and grid spacings. Our results show clear enhancement of the image contrast by factors of four to six using a high Z mesh with large grid spacing. This leads to further improvement in the accuracy of the magnetic field measurement using this technique in comparison with its first demonstration at the OMEGA laser facility [Rev. Sci. Instrum. 93, 023502 (2022) [CrossRef]].

47 OTHER INSTRUMENTATION↗

Self-Driving Telescopes: Autonomous Scheduling of Astronomical Observation Campaigns with Offline Reinforcement Learning

Modern astronomical experiments are designed to achieve multiple scientific goals, from studies of galaxy evolution to cosmic acceleration. These goals require data of many different classes of night-sky objects, each of which has a particular set of observational needs. These observational needs are typically in strong competition with one another. This poses a challenging multi-objective optimization problem that remains unsolved. The effectiveness of Reinforcement Learning (RL) as a valuable paradigm for training autonomous systems has been well-demonstrated, and it may provide the basis for self-driving telescopes capable of optimizing the scheduling for astronomy campaigns. Simulated datasets containing examples of interactions between a telescope and a discrete set of sky locations on the celestial sphere can be used to train an RL model to sequentially gather data from these several locations to maximize a cumulative reward as a measure of the quality of the data gathered. We use simulated data to test and compare multiple implementations of a Deep Q-Network (DQN) for the task of optimizing the schedule of observations from the Stone Edge Observatory (SEO). We combine multiple improvements on the DQN and adjustments to the dataset, showing that DQNs can achieve an average reward of 87%+-6% of the maximum achievable reward in each state on the test set. This is the first comparison of offline RL algorithms for a particular astronomical challenge and the first open-source framework for performing such a comparison and assessment task.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Collimation on Diffraction Signal-to-Background Ratios at a Neutron Diffractometer

High diffraction signal-to-background ratios (SBRs), the ratios of diffraction peak integrated intensity over its background intensity, are desired for a neutron diffractometer to acquire good statistics for diffraction pattern measurements and subsequent data analysis. For a given detector, while the diffraction peak signals primarily depend on the characteristics of neutron beam and sample coherent scattering, the background largely originates from the sample incoherent scattering and the scattering from the instrument space. In this work, we investigated the effect of collimation on neutron diffraction SBRs of Si powder measurements using one high-angle area detector bank coupled with six different collimation configurations in a large and complex instrument space at the engineering materials diffractometer VULCAN, SNS, ORNL. The results revealed that the diffraction SBRs can be significantly improved by a proper coarse collimator that leaves no gap between the detector and the collimator, and the improvement of SBRs by a fine radial collimator was remarkable with a proper coarse collimator in place but not distinguishable without one. It was also found that the diffraction SBRs were not effectively improved by adding neutron absorbing element boron to the fine radial collimator body, which indicates that either the absorption of secondary scattered neutrons by the added boron is insignificant or the collimator base material (resin and ABS) alone attenuates background scattering sufficiently. These findings could serve as a useful reference for diffractometer developers and/or operators to optimize their collimation to achieve higher diffraction SBRs.

Yu, Dunji↗

Internal 2-D Surface Temperature Measurements for Large Complex Geometries

For 2D-temperature monitoring applications, a variant of EIT (Electrical Impedance Tomography) is evaluated computationally in this work. Literature examples of poor sensor performance in the center of the 2D domains away from the side electrodes motivated this study which seeks to overcome some of the previously noted shortcomings. In particular, the use of ‘sensing skins’ with novel tailored baseline conductivities were examined using the EIDORS package for EIT. It was found that the best approach for detecting a hot spot depends on several factors such as the current injection (stimulation) patterns, the measurement patterns, and the reconstruction algorithms. For a well-performing combination of these factors, tailored baseline conductivities were assessed and compared to the baseline uniform conductivity. It was discovered that for some EIT applications, a tailored distribution needs to be smooth and that sudden changes in the conductivity gradients should be avoided. Still, the benefits in terms of improved EIT performance were small for conditions for which the EIT measurements had been ‘optimized’ for the uniform baseline case. Within the limited scope of this study, only two specific cases showed benefits from tailored distributions. For one case, a smooth tailored distribution with increased baseline conductivity in the center provided a better separation of two centrally located hot spots. For another case, a smooth tailored distribution with reduced conductivity in the center provided better estimates of the magnitudes of two hot spots near the center of the sensing skin.

47 OTHER INSTRUMENTATION↗

The Analog Front-end for the LGAD Based Precision Timing Application in CMS ETL

The analog front-end for the Low Gain Avalanche Detector (LGAD) based precision timing application in the CMS Endcap Timing Layer (ETL) has been prototyped in a 65 nm CMOS mini-ASIC named ETROC0. Serving as the very first prototype of ETL readout chip (ETROC), ETROC0 aims to study and demonstrate the performance of the analog frontend, with the goal to achieve 40 to 50 ps time resolution per hit with LGAD (therefore reach about 30ps per track with two detector-layer hits per track). ETROC0 consists of preamplifier and discriminator stages, which amplifies the LGAD signal and generates digital pulses containing time of arrival and time over threshold information. This paper will focus on the design considerations that lead to the ETROC front-end architecture choice, the key design features of the building blocks, the methodology of using the LGAD simulation data to evaluate and optimize the front-end design. The ETROC0 prototype chips have been extensively tested using charge injection and the measured performance agrees well with simulation. The initial beam test results are also presented, with time resolution of around 33 ps observed from the preamplifier waveform analysis and around 41 ps from the discriminator pulses analysis. A subset of ETROC0 chips have also been tested to a total ionizing dose of 100 MRad with X-ray and no performance degradation been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bias‐Dependent Quantum Efficiency Reveals Recombination Pathways in Thin Film Solar Cells

Identifying where recombination predominantly occurs—whether at the front interface, back interface, or throughout the bulk—is crucial for optimizing CdSeTe solar cells and many other photovoltaic device architectures. Here, a simple and effective diagnostic is demonstrated: measuring external quantum efficiency (QE) under varying forward biases. The drift–diffusion simulations reveal that each recombination pathway leaves a distinct bias-induced signature in the normalized QE: a progressive drop at long wavelengths for back-limited devices, a short-wavelength decline for front-limited devices, and a relatively uniform decrease across all wavelengths for bulk-limited devices. These predictions are validated with experiments on As-doped and Cu-doped CdSeTe devices, with and without passivation layers or different front buffers. In each case, the observed bias-dependent QE spectral changes align with the simulated recombination map. Because this method uses standard QE instrumentation, it offers a broadly accessible and cost-efficient means to diagnose recombination pathways—extending beyond CdSeTe to other thin-film and emerging solar cell technologies. By pinpointing recombination bottlenecks, researchers and manufacturers can strategically refine doping profiles, passivation schemes, and interface designs to further improve device performance.

CdTe↗

Compact in situ probe for magnetotransport measurements of 2D materials under variable tensile strain

The recent development of freestanding oxide membranes has opened new opportunities for strain engineering of transition metal oxides beyond values accessible in bulk samples. While a number of studies have been performed with fixed strain, the ability to dynamically control the strain state during measurement would be greatly enabling. To this end, we present an in situ uniaxial strain probe optimized for transport measurements of tensile-strained 2D or quasi-2D materials down to 2 K. Utilizing a flexible polyimide substrate as the stress transfer medium, our platform simplifies the sample preparation process and allows precise alignment of strain fields relative to the crystalline axes. An in situ optical microscope monitors the macroscopic strain state operando and makes it possible to complete an entire magnetotransport study at cryogenic temperatures under continuous strain variations. We demonstrate the capabilities of the probe on a freestanding LaNiO 3 membrane, where we induce tensile strain up to 8% and observe a corresponding strong transport anisotropy. In view of the rapid developments in low-dimensional materials synthesis and the plethora of novel quantum phenomena they exhibit, this strain probe provides general instrumentation for examining and controlling these properties via strain.

2D materials↗

Analyzing the Calibration History of Radiometers for Determining Optimal Calibration Day(s)

This study investigates the effects of calibrating radiometers using one day or multiple cloudless days as recommended by ASTM and ISO standards. The results demonstrate good responsivity agreement with estimated uncertainty error bars over the years for various radiometers under various Broadband Outdoor Radiometer Calibration (BORCAL) events at both the National Renewable Energy Laboratory and the Southern Great Plains facility. The BORCAL method appears to justify the use of a single calibration day with enough data points to attain repeatable calibration results.

BORCAL↗

Standoff trace explosives vapor detection at meter distances

Vapor detection is a noncontact sampling method, which is a less invasive means of explosives screening than physical swiping. Explosive vapor detection is a challenge due to the low levels of vapors available for detection. This study demonstrates that the parts-per-quadrillion sensitivity of atmospheric flow tube-mass spectrometry (AFT-MS) combined with a high-volume air sampler enables standoff detection of trace explosives vapor at distances of centimeters to meters. Standoff detection of explosives vapor was possible both upstream and downstream of the vapor source relative to room air currents. RDX vapor from a saturated source was detected at up to 2.5 m. Vapors from RDX residue and nitroglycerin residue were detected at distances up to 0.5 m. The sampling can be optimized by accounting for air movement in the room or environment, which could further extend standoff detection distances. In conclusion, using AFT-MS with a high-volume sampler could also be effective for standoff vapor detection of drugs and additional chemical threats and could be useful for security screening applications such as at mail facilities, border crossings, and security checkpoints.

47 OTHER INSTRUMENTATION↗

A Q-band frequency tunable Doppler backscattering (DBS) system for pedestal and scrape-off layer density fluctuation and flow measurements in the DIII-D tokamak

We present the design and laboratory tests for a new Q-band frequency tunable Doppler backscattering (DBS) system suitable for probing poloidal wavenumber kñ = 6–8 cm−1 density fluctuations and their flow velocities in the pedestal and scape-off layer (SOL) of the DIII-D tokamak. This system will provide new measurements in the increasingly important and under-diagnosed far pedestal and SOL plasma regions. These results are important for experimental transport studies and necessary for the validation of transport models, both of which are important to fusion energy research. The use of a single tunable frequency reduces the complexity and potential failure points as compared to a multichannel system. This new system utilizes a 33–50 GHz tunable source and will be integrated into the current V-band DBS in DIII-D using a broadband Q- and V-band multiplexer. A full-scale mockup of the quasi-optical system was used to test and optimize the performance. These tests include beam profile measurements at different distances (and angles) from a paraboloidal focusing and steering mirror. The measurements cover the full frequency range 33–75 GHz of the integrated/combined Q–V band DBS system and target a large radial coverage of the low-field side of the plasma from ρ = 1.1 to ρ = 0.5, where ρ is the normalized flux surface radial coordinate.

Instruments & Instrumentation↗