Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

KEA-144: Final Results of the Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) Project

GODU-LH2 system has successfully met all test objectives at the 33%, 67%, and 100% tank fill level. Complete control over the state of the fluid has been demonstrated using Integrated Refrigeration and Storage (IRAS). Almost any desired point along the H2saturation curve can essentially be "dialed in" and maintained indefinitely. System can also be used to produce densified hydrogen in large quantities to the triple point. Exploring multiple technology infusion paths. Studying implementation of IRAS technology into new LH2sphere for EM-2 at LC39B. Technical interchange also occurring with STMD, LSP, ULA, DoE, KIST, Kawasaki, Shell Oil, SpaceX, US Coast Guard, and Virgin Galactic.

GODU-LH2↗

Externally Heated Protostellar Cores in the Ophiuchus Star-Forming Region

We present APEX 218 GHz observations of molecular emission in a complete sample of embedded protostars in the Ophiuchus star-forming region. To study the physical properties of the cores, we calculate H2CO and c-C3H2 rotational temperatures, both of which are good tracers of the kinetic temperature of the molecular gas. We find that the H2CO temperatures range between 16K and 124K, with the highest H2CO temperatures toward the hot corino source IRAS 16293-2422 (69-124 K) and the sources in the rho Oph A cloud (23-49 K) located close to the luminous Herbig Be star S1, which externally irradiates the rho Oph A cores. On the other hand, the c-C3H2 rotational temperature is consistently low (7-17 K) in all sources. Our results indicate that the c-C3H2 emission is primarily tracing more shielded parts of the envelope whereas the H2CO emission (at the angular scale of the APEX beam; 3600 au in Ophiuchus) mainly traces the outer irradiated envelopes, apart from in IRAS16293-2422, where the hot corino emission dominates. In some sources, a secondary velocity component is also seen, possibly tracing the molecular outflow.

CH3OH↗

Zero Boil-Off Methods for Large Scale Liquid Hydrogen Tanks Using Integrated Refrigeration and Storage

NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multi-layer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

ZBO↗

Large Scale Production of Densified Hydrogen Using Integrated Refrigeration and Storage

Recent demonstration of advanced liquid hydrogen storage techniques using Integrated Refrigeration and Storage (IRAS) technology at NASA Kennedy Space Center led to the production of large quantities of solid densified liquid and slush hydrogen in a 125,000 L tank. Production of densified hydrogen was performed at three different liquid levels and LH2 temperatures were measured by twenty silicon diode temperature sensors. System energy balances and solid mass fractions are calculated. Experimental data reveal hydrogen temperatures dropped well below the triple point during testing (up to 1 K), and were continuing to trend downward prior to system shutdown. Sub-triple point temperatures were seen to evolve in a time dependent manner along the length of the horizontal, cylindrical vessel. Twenty silicon diode temperature sensors were recorded over approximately one month for testing at two different fill levels (33 67). The phenomenon, observed at both two fill levels, is described and presented detailed and explained herein., and The implications of using IRAS for energy storage, propellant densification, and future cryofuel systems are discussed.

Notardonato, William U.↗

Development of an 400 L Integrated Refrigeration and Storage Cryostat for LNG/LCH4 Research

Research engineers from the Cryogenics Test Laboratory at NASA Kennedy Space Center in Florida have developed a 400 liter Integrated Refrigeration and Storage (IRAS) cryostat to explore advanced techniques for storage, conditioning, and transfer of liquefied natural gas and/or pure methane. A vertical-cylindrical configuration, the vacuum-jacketed apparatus houses a G-M cryocooler to control the state of the fluid, and sample tubes with corresponding temperature sensors fixed at various elevations to allow for sampling of the liquid. Two additional ports were also included for future instrumentation and/or mechanical feed-throughs. A primary goal of this test apparatus will be to study the effect of IRAS on the behavior of LNG during storage; most notably weathering and stratification of the bulk liquid over time. Additionally, in-situ liquefaction of natural gas can be performed, along with zero boil-off control, liquid densification, and slush production.

Swanger, Adam M.↗

Energy Efficient Large-Scale Storage of Liquid Hydrogen

World’s largest LH2storage tanks constructed in mid-1960s at NASA/KSC. These vacuum-perlite insulated tanks, still in service today, are 3,200 m3capacity (ea.). In 2018, construction began on an additional 4,700 m3LH2storage tank at LC-39B•NASA’s new Space Launch System (SLS) heavy lift rocket for Artemis program holds 2,033 m3of LH2in its 8.4-m diameter by 40-m height. Two new energy-efficient technologies are included: glass bubbles insulation system and an Integrated Refrigeration and Storage (IRAS) heat exchanger for passive + active thermal control:•Evacuated glass bubbles insulation system has been shown to reduce LH2boiloff by 46% versus perlite in field demonstrations. Controlled storage via IRAS, when fully implemented, will provide full control of ullage pressure, zero boiloff, and even production of densified LH22CEC-2021

cryogenics↗

Energy of Fluid (EOF) Simulation of Large-Scale Densification and Solidification of Hydrogen

The current research develops a finite volume-based Computation Fluid Dynamic (CFD) model utilizing an Energy of Fluid (EOF) approach to generate a simulation of the densification of liquid hydrogen (LH2) in the Integrated Refrigeration and Storage (IRAS) experimental tank for the Ground Operations Demonstration Unit for Liquid Hydrogen Project (GODU-LH2) at the Kennedy Space Center (KSC). The computational code will integrate a commercial software pressure-based model with User Defined Functions (UDF) generated and added to the model. The modified model will solve the energy equation in terms of internal energy and provide temperature and pressure calculations for a given tank geometry. This method will decrease computational time when compared to the built-in commercially available Enthalpy solvers. Currently the research focused on utilizing User Defined Scalars (UDS) compared to the enthalpy model and a lumped node analysis to show the written UDS is as accurate as the built-in solvers, and the models will be verified using known solutions for solidification and validated with the experimental results from the Cryogenics Test Laboratory (CTL) at KSC for the IRAS densification process.

C. Mahony↗

Simulations of Zero Boiloff, Densification, and Solidification in a Large-Scale Liquid Hydrogen Tank

The current research utilizes an Energy of Fluid (EOF) approach to develop a finite volume-based Computation Fluid Dynamic (CFD) model to create a benchmark simulation of the densification of liquid hydrogen (LH2) in an experimental Integrated Refrigeration and Storage (IRAS) tank at the Kennedy Space Center (KSC). The computational code will incorporate the FLUENT pressure-based model with User Defined Functions (UDF) to implement the EOF model. The enhanced model will solve the energy equation in terms of internal energy and provide temperature and pressure calculations for a given tank geometry. Specifically, a convection term will be added to an already existing code for a more accurate simulation of LH2 densification. However, currently the research focuses on utilizing User Defined Scalars (UDS) with FLUENT to show the built-in solvers are as accurate as the written UDS. This will reduce the computational time down significantly by utilizing an already built in solver for the momentum equation. A custom UDF has been written to solve transient and steady state conduction, and results obtained using the UDF agree with results obtained using the built-in FLUENT solver. Currently, a convection UDF is being added and will be verified using known solutions for solidification and validated with the experimental results from the Cryogenics Test Laboratory (CTL) at KSC for the IRAS densification process.

Colin Philip Mahony↗

Development of a Portable Stand-Alone 20 K Brayton Cycle Helium Refrigeration System

From 2012 to 2015, NASA funded development of the Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) at Kennedy Space Center that scaled up and matured Integrated Refrigeration and Storage (IRAS) technology. IRAS involves the integration of an external helium refrigeration system with a cryogenic storage tank via an internal heat exchanger and allows advanced operations such as zero boiloff and densification of the liquid. The refrigeration system employed for GODU-LH2 was a Linde LR1620 piston-Brayton cycle machine with an RSX helium compressor. The GODU-LH2 system was installed in two separate shipping containers—one housing the cold-box, compressor, and gas management hardware, and the other the water chiller unit—with 480 VAC and 120 VAC electrical power fed from external hardware at the test site, and data capture and controls achieved using four different, independent software packages. From 2017 to 2019, in support of a densified hydrogen loading test program, the entire system was repackaged into a single, 40’ (12 m) shipping container, including the refrigeration system, water chiller, and electrical power distribution hardware, and controls were consolidated into a single Allen Bradley PanelView. Details regarding the design, build-out, and testing of the system will be presented and discussed.

W F Reaves↗

Simulations of Large-Scale Zero Boiloff, Densification, and Solidification of Hydrogen

An Integrated Refrigeration and Storage (IRAS) experimental system called the Ground Operations and Demonstration Unit for Liquid Hydrogen (GODU-LH2) demonstrated the ability store cryogens in a zero boiloff (ZBO) process, and to densify liquid hydrogen by reducing the temperature and pressure down to the triple point resulting in solidification. The incompressible Navier-Stokes was utilized to simulate ZBO, densification, and solidification of liquid hydrogen (LH2) in the IRAS tank. The simulations were performed using a commercially available Computational Fluid Dynamics (CFD) pressure-based mass and momentum flow model and an enthalpy-porosity energy model. Results demonstrated the simulation’s ability to predict time-dependent flow and temperature fields and solid-liquid phase locations for hydrogen during ZBO, densification, and solidification. The simulations showed good agreement with experimental data, with errors within acceptable ranges for temperature and pressure predictions, provided detailed insights into natural convection and solid-liquid phase change dynamics. These findings are critical for the design of future cryogenic fluid management systems.

Computational Fluid Dynamics↗

Microreactor-liquid metal battery system in energy markets: An evaluation of potential costs, technology, and policy impacts

Microreactors represent an emerging innovation in the nuclear industry; yet have been overshadowed by their high capital costs. With the Inflation Reduction Act of 2022 (IRA), new opportunities have emerged to improve the economics of microreactor systems. This work examines liquid metal batteries (LMB) as a value-adding technology as part of microreactor-LMB systems within three U.S. electricity markets: ERCOT, PJM, and MISO. Our investigation considers key uncertainties: the cost of microreactors, the performance of LMBs, and the eligible tax credit levels. To this end, we use a dispatch optimization to trace not only the changes in system economics but also to provide a granular picture of energy delivery within the systems. We find that even with favorable costs for microreactors, significant regional variations in the project sizing and returns exist across the markets. Our heuristic method identifies their non-electric application potentials beyond electricity and technical requirements to maximize returns. The results suggest that 12–39 % of reactor heat could be cost-effectively diverted to produce more valuable by-products in U.S. markets. Including the impacts of tax credits, we establish the outcomes of each provision with varying rates. Coupling an LMB to a microreactor consistently improves the net present value of a microreactor compared to its standalone operation. In conclusion, for reasonable assumed conditions, we quantify a heterogeneous impact of round-trip efficiency (RTE) and extended LMB service life across the three markets—a one-year extension in LMB service life is roughly equivalent to a 2.11 % improvement in RTE for ERCOT, 1.16 % for PJM, and 1.04 % for MISO.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Comprehensive structural characterization of charged polymers involved in moisture-driven direct air capture

This study provides a comprehensive structural characterization of commercially available alkaline anion-exchange polymers (Fumasep FAA-3 and IRA 900) used in moisture-driven direct air capture (DAC) of carbon dioxide. Using X-ray diffraction, SAXS/WAXS, atomic force microscopy, FIB-SEM, and transmission electron microscopy, the authors identify nanoscale clustering, porosity, swelling behavior, and humidity-dependent structural changes that influence CO₂ adsorption and release. These findings establish structure–function relationships critical for designing more durable and energy-efficient DAC polymer materials.

36 MATERIALS SCIENCE↗

Summary of Airfoil Data

Recent airfoil data for both flight and wind-tunnel tests have been collected and correlated insofar as possible. The flight data consist largely of drag measurements made by the wake-survey method. Most of the data on airfoil section characteristics were obtained in the Langley two-dimensional low-turbulence pressure tunnel. Detail data necessary for the application of NACA 6-serles airfoils to wing design are presented in supplementary figures, together with recent data for the NACA 24-, 44-, and 230-series airfoils. The general methods used to derive the basic thickness forms for NACA 6- and 7-series airfoils and their corresponding pressure distributions are presented. Data and methods are given for rapidly obtaining the approximate pressure distributions for NACA four-digit, five-digit, 6-, and 7-series airfoils. The report includes an analysis of the lift, drag, pitching-moment, and critical-speed characteristics of the airfoils, together with a discussion of the effects of surface conditions. Available data on high-lift devices are presented. Problems associated with lateral-control devices, leading-edge air intakes, and interference are briefly discussed. The data indicate that the effects of surface condition on the lift and drag characteristics are at least as large as the effects of the airfoil shape and must be considered in airfoil selection and the prediction of wing characteristics. Airfoils permitting extensive laminar flow, such as the NACA 6-series airfoils, have much lower drag coefficients at high speed and cruising lift coefficients than earlier types-of airfoils if, and only if, the wing surfaces are sufficiently smooth and fair. The NACA 6-series airfoils also have favorable critical-speed characteristics and do not appear to present unusual problems associated with the application of high-lift and lateral-control devices. Much of the data given in the NACA Advance Confidential Report entitled "Preliminary Low-Drag-Airfoil and Flap Data from Tests at Large Reynolds Number and Low Turbulence," by Eastman N. Jacobs, Ira R. Abbott, and Milton Davidson, March 1942 has been corrected and included in the present paper, which supersedes the previously published paper.

LOW-DRAG↗

(abstract) Physical Properties of 253 Mathilde from Groundbased Observations

The only physical observations which predate the identifications of 253 Mathilde as a potential flyby target of NEAR were measurements of its absolute magnitude in reflected light and thermal radiometry by IRAS. Mathilde has been revealed to be an unusual object, of a class not previously visited by a spacecraft.

Mathilde 253 IRAS albedo flyby↗

Star Formation in Taurus: Preliminary Results from 2MASS

Data with the 2MASS prototype camera were obtained in a 2.3 sq. deg region in Taurus containing Heiles Cloud 2, a region known from IRAS observations to contain a number of very young solar type stars.

Taurus 2MASS IRAS molecular gas source Heiles Clou↗

Stability of Small Grains in HII Regions and Reflection Nebulae

We have analyzed IRAS data to assess the relative amounts of small and large grains in HII regions and reflection nebulae. Our most important finding is that no evidence for small grain destruction is seen in reflection nebulae, even for [high] values of the radiation energy density at which significant grain destruction apparently occurs in HII regions. This suggests that it is not only the total radiant energy density but also the energy per photon which determines the stability of small grains in astrophysical environments.

photons IRAS↗

Ultraluminous Infrared Galaxies

One of the most important results of the IRAS mission was the establishment that there exists a class of galaxies which emit over 90% of their energy in the far infrared.

energy sourcesUL galaxies IRAS protogalaxy↗