Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Effect of argon ion implantation on the electrical and dielectric properties of CR-39

The objective of the present work is to study the effect of 130 keV Ar{sup +} ions on the electrical and dielectric properties of CR-39 samples at various doses 5×10{sup 14}, 1×10{sup 15} and 1×10{sup 16} Ar{sup +} cm{sup −2}. Current-Voltage (I-V characteristics) measurements have been used to study the electrical properties of virgin and Ar{sup +} implanted CR-39 specimens. The current has been found to be increased with increasing voltage as well as with increasing ion dose. The dielectric spectroscopy of these specimens has been done in the frequency range of 100 kHz-100 MHz. The dielectric constant has been found to be decreasing whereas dielectric loss factor increases with increasing ion fluence. These kind of behavior observed in the implanted specimens indicate towards the formation of carbonaceous clusters due to the cross linking, chemical bond cleavage, formation of free radicals. The changes observed in the dielectric behavior have been further correlated with the structural changes observed through I-V characteristics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvement of the titanium implant biological properties by coating with poly (ε-caprolactone)-based hybrid nanocomposites synthesized via sol-gel

When bioactive coatings are applied to medical implants by means of sol-gel dip coating technique, the biological proprieties of the implant surface can be modified to match the properties of the surrounding tissues. In this study organo-inorganic nanocomposites materials were synthesized via sol-gel. They consisted of an inorganic zirconium-based and silica-based matrix, in which a biodegradable polymer (the poly-ε-caprolactone, PCL) was incorporated in different weight percentages. The synthesized materials, in sol phase, were used to dip-coat a substrate of commercially pure titanium grade 4 (CP Ti gr. 4) in order to improve its biological properties. A microstructural analysis of the obtained films was carried out by scanning electron microscopy (SEM) and attenuated total reflectance (ATR) Fourier transform infrared spectroscopy (FT-IR). Biological proprieties of the coated substrates were investigated by means of in vitro tests.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Direct synthesis of ultrathin SOI structure by extremely low-energy oxygen implantation

We performed extremely low-energy {sup 16}O{sup +} implantation at 10 keV (R{sub p} ∼ 25 nm) followed by annealing aiming at directly synthesizing an ultrathin Si layer separated by a buried SiO{sub 2} layer in Si(001) substrates, and then investigated feasible condition of recrystallization and stabilization of the superficial Si and the buried oxide layer by significantly low temperature annealing. The elemental compositions were analyzed by Rutherford backscattering (RBS) and secondary ion mass spectroscopy (SIMS). The crystallinity of the superficial Si layer was quantitatively confirmed by ananlyzing RBS-channeling spectra. Cross-sectional morphologies and atomic configurations were observed by transmission electron microscope (TEM). As a result, we succeeded in directly synthesizing an ultrathin single-crystalline silicon layer with ≤20 nm thick separated by a thin buried stoichiometric SiO{sub 2} layer with ≤20 nm thick formed by extremely low-energy {sup 16}O{sup +} implantation followed by surprisingly low temperature annealing at 1050{sup ∘} C.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectroscopic analysis of the NIR emission in Tm implanted Al{sub x}Ga{sub 1-x}N layers

Al{sub x}Ga{sub 1-x}N samples, with different AlN molar fractions, x = 0, 0.15, 0.77, and 1, grown by halide vapor phase epitaxy were implanted with Tm ions. Photoluminescence (PL) measurements revealed that after thermal annealing all the samples exhibit intraionic Tm{sup 3+} luminescence. In samples with x > 0, the low temperature emission is dominated by the lines that appear in the near infrared (NIR) spectral region, corresponding to the overlapped {sup 1}G{sub 4} → {sup 3}H{sub 5} and {sup 3}H{sub 4} → {sup 3}H{sub 6} multiplet transitions. A detailed spectroscopic analysis of NIR emission of the thulium implanted and annealed Al{sub x}Ga{sub 1-x}N layers is presented by using temperature dependent steady-state PL, room temperature PL excitation, and time resolved PL. The results indicate that the excitonic features sensitive to the alloy disorder are involved in the excitation population processes of the Tm{sup 3+} luminescence and the highest thermal stability for the NIR emission occurs for the AlN:Tm sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combining femtosecond laser annealing and shallow ion implantation for local color center creation in diamond

A common technique for color center creation in wideband gap semiconductors employs ion implantation and a subsequent thermal annealing. In general, this annealing process is conducted in a vacuum oven. Here, we exploit the annealing based on femtosecond laser pulses. For that purpose, we implant fluorine ions at 54 keV and chlorine ions at 74 keV in diamond and perform micrometer precise annealing using focused femtosecond laser pulses at 800 ± (30) nm with different pulse numbers and repetition rates. In this way, we were able to create shallow spots with color centers of varying brightness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Creation of color centers in diamond by recoil implantation through dielectric films

The need of near-surface color centers in diamond for quantum technologies motivates the controlled doping of specific extrinsic impurities into the crystal lattice. Further, recent experiments have shown that this can be achieved by momentum transfer from a surface precursor via ion implantation, an approach known as “recoil implantation.” Here, we extend this technique to incorporate dielectric precursors for creating nitrogen-vacancy (NV) and silicon-vacancy (SiV) centers in diamond. Specifically, we demonstrate that gallium focused-ion-beam exposure to a thin layer of silicon nitride or silicon dioxide on the diamond surface results in the introduction of both extrinsic impurities and carbon vacancies. These defects subsequently give rise to near-surface NV and SiV centers with desirable properties after annealing.

42 ENGINEERING↗

Magnetic metamaterials by ion-implantation

We present a method for the additive fabrication of planar magnetic nanoarrays with minimal surface roughness. Synthesis is accomplished by combining electron-beam lithography, used to generate nanometric patterned masks, with ion implantation in thin films. By implanting 56 Fe + ions, we are able to introduce magnetic functionality in a controlled manner into continuous Pd thin films, achieving 3D spatial resolution down to a few tens of nanometers. Our results demonstrate the application of this technique in fabricating square artificial spin ice lattices, which exhibit well-defined magnetization textures and interactions among the patterned magnetic elements.

36 MATERIALS SCIENCE↗

Synergetic effects of dual-beam implantation on the microstructural development in silicon

We report a synergy effect on the microstructural development of silicon specimens as a result of dual-beam high temperature irradiation/implantation. In situ transmission electron microscopy experiments using two different experimental setups have been used, where the primary 50 keV Co{sup +} ion implantation beam was supplemented with either a 300 keV electron beam or a 500 keV Si{sup +} ion beam. In both cases, the secondary beam intensity was such that both beams created comparable overall primary damage. Completely different microstructural response has been found in these two cases. An intensive electron irradiation was found to sharply accelerate the evolution of dislocation structure, only weakly affecting the disilicide kinetics. On the contrary, the Si ion beam weakly affected the kinetics of either dislocation loops or coherent CoSi{sub 2} precipitates, but drastically increased the number density of thermodynamically unstable semicoherent precipitates. Possible microstructural reasons for the observed effects and the implications for both dislocation loop and cobalt disilicide nucleation mechanisms in high-temperature implanted TEM samples are discussed and supported by detailed molecular dynamics calculations of annealing of cascade remnants produced by the energetic silicon recoils.

36 MATERIALS SCIENCE↗

Fabrication of freestanding LiNbO{sub 3} thin films via He implantation and femtosecond laser ablation

The authors report using a combination of ion-implantation exfoliation and femtosecond laser ablation to fabricate thin (micrometers-thick) single-crystal films of a complex oxide, LiNbO{sub 3}. The process physics for the method is bounded by the threshold for ablation and the onset of laser thermal outdiffusion of the implanted He used in exfoliation selective etching.

36 MATERIALS SCIENCE↗

Order-of-magnitude differences in retention of low-energy Ar implanted in Si and SiO{sub 2}

The retention of 1 and 5 keV Ar implanted at 45° in Si and 4.3 nm SiO{sub 2} on Si was studied at fluences between 3 × 10{sup 14} and 1.5 × 10{sup 16} cm{sup −2}. X-ray photoelectron spectroscopy (XPS) served to monitor the accumulation of Ar as well as the removal of SiO{sub 2}. Bombardment induced changes in oxygen chemistry caused the O 1s peak position to move toward lower binding energies by as much as 2.2 eV. Plotted versus depth of erosion, the fluence dependent changes in oxygen content, and peak position were similar at 1 and 5 keV. The Ar content of Si increased with increasing exposure, saturating at fluences of ∼2 × 10{sup 15} cm{sup −2} (1 keV) and ∼6 × 10{sup 15} cm{sup −2} (5 keV). Much less Ar was retained in the SiO{sub 2}/Si sample, notably at 1 keV, in which case the low-fluence Ar signal amounted to only 8% of the Si reference. The results imply that essentially no Ar was trapped in undamaged SiO{sub 2}, i.e., the Ar atoms initially observed by XPS were located underneath the oxide. At the lowest fluence of 5 keV Ar, the retention ratio was much higher (43%) because the oxide was already highly damaged, with an associated loss of oxygen. The interpretation was assisted by TRIM(SRIM) calculations of damage production. Partial maloperation of the ion beam raster unit, identified only at a late stage of this work, enforced a study on the uniformity of bombardment. The desired information could be obtained by determining x,y line scan profiles of O 1s across partially eroded SiO{sub 2}/Si samples. Fluence dependent Ar retention in Si was described using an extended version of the rapid relocation model which takes into account that insoluble implanted rare-gas atoms tend to migrate to the surface readily under ongoing bombardment. The range parameters required for the modeling were determined using TRIM(SRIM); sputtering yields were derived from the literature. The other three parameters determining the Ar signal, i.e., (1) the thickness w of the near-surface Si region devoid of Ar, (2) the relocation efficiency Ψ{sub rlc}, and (3) the effective attenuation length L in XPS analysis were varied within reasonable limits until the calculated retention curves for 1 and 5 keV Ar in Si agreed with experimental data to better than 8%, using the same XPS sensitivity factor throughout. Results: w = 1.4 ± 0.1 nm, Ψ{sub rlc} = 6.6 ± 0.5, and L = 2.7 ± 0.2 nm. Combining experimental and calculated data, it was found that the Ar trapping efficiency of the damaged oxide is intimately correlated with the loss of oxygen. The calculated stationary areal densities of all retained Ar are compared with results obtained by high-resolution medium-energy ion scattering spectrometry. Attractive areas of future research in rare gas retention and nanobubble formation are sketched briefly.

42 ENGINEERING↗

XPS and SIMS study of the surface and interface of aged C + implanted uranium

X-ray photoelectron spectroscopy in combination with secondary ion mass spectrometry depth profiling were used to investigate the surface and interfacial chemistry of C + ion implanted polycrystalline uranium subsequently oxidized in air for over 10 years at ambient temperature. The original implantation of 33 keV C + ions into U 238 with a dose of 4.3 × 10 17 cm –3 produced a physically and chemically modified surface layer that was characterized and shown to initially prevent air oxidation and corrosion of the uranium after 1 year in air at ambient temperature. The aging of the surface and interfacial layers were examined by using the chemical shift of the U 4f, C 1s, and O 1s photoelectron lines. In addition, valence band spectra were used to explore the electronic structure of the aged carbide surface and interface layer. Moreover, the time-of-flight secondary ion mass spectrometry depth profiling results for the aged sample confirmed an oxidized uranium carbide layer over the carbide layer/U metal interface.

36 MATERIALS SCIENCE↗

Analysis of dose to patient, spouse/caretaker, and staff, from an implanted trackable radioactive fiducial for use in the radiation treatment of prostate cancer

Purpose: A fiducial tracking system based on a novel radioactive tracking technology is being developed for real-time target tracking in radiation therapy. In this study, the authors calculate the radiation dose to the patient, the spouse/caretaker, and the medical staff that would result from a 100 {mu}Ci Ir192 radioactive fiducial marker permanently implanted in the prostate of a radiation therapy patient. Methods: Local tissue dose was calculated by Monte Carlo simulation. The patient's whole body effective dose equivalent was calculated by summing the doses to the sensitive organs. Exposure of the spouse/caretaker was calculated from the NRC guidelines. Exposure of the medical staff was based on estimates of proximity to and time spent with the patient. Results: The local dose is below 40 Gy at 5 mm from the marker and below 10 Gy at 10 mm from the marker. The whole body effective dose equivalent to the patient is 64 mSv. The dose to the spouse/caretaker is 0.25 mSv. The annual exposures of the medical staff are 0.2 mSv for a doctor performing implantations and 0.34 mSv for a radiation therapist positioning patients for therapy. Conclusions: The local dose is not expected to have any clinically significant effect on the surrounding tissue which is irradiated during therapy. The dose to the patient is small in comparison to the whole body dose received from the therapy itself. The exposure of all other people is well below the recommended limits. The authors conclude that there is no radiation exposure related contraindication for use of this technology in the radiation treatment of prostate cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

CT image artifacts from brachytherapy seed implants: A postprocessing 3D adaptive median filter

Purpose: To design a postprocessing 3D adaptive median filter that minimizes streak artifacts and improves soft-tissue contrast in postoperative CT images of brachytherapy seed implantations. Methods: The filter works by identifying voxels that are likely streaks and estimating more reflective voxel intensity by using voxel intensities in adjacent CT slices and applying a median filter over voxels not identified as seeds. Median values are computed over a 5x5x5 mm region of interest (ROI) within the CT volume. An acrylic phantom simulating a clinical seed implant arrangement and containing nonradioactive seeds was created. Low contrast subvolumes of tissuelike material were also embedded in the phantom. Pre- and postprocessed image quality metrics were compared using the standard deviation of ROIs between the seeds, the CT numbers of low contrast ROIs embedded within the phantom, the signal to noise ratio (SNR), and the contrast to noise ratio (CNR) of the low contrast ROIs. The method was demonstrated with a clinical postimplant CT dataset. Results: After the filter was applied, the standard deviation of CT values in streak artifact regions was significantly reduced from 76.5 to 7.2 HU. Within the observable low contrast plugs, the mean of all ROI standard deviations was significantly reduced from 60.5 to 3.9 HU, SNR significantly increased from 2.3 to 22.4, and CNR significantly increased from 0.2 to 4.1 (all P<0.01). The mean CT in the low contrast plugs remained within 5 HU of the original values. Conclusion: An efficient postprocessing filter that does not require access to projection data, which can be applied irrespective of CT scan parameters has been developed, provided the slice thickness and spacing is 3 mm or less.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT, MR, and ultrasound image artifacts from prostate brachytherapy seed implants: The impact of seed size

Purpose: To investigate the effects of brachytherapy seed size on the quality of x-ray computed tomography (CT), ultrasound (US), and magnetic resonance (MR) images and seed localization through comparison of the 6711 and 9011 {sup 125}I sources. Methods: For CT images, an acrylic phantom mimicking a clinical implantation plan and embedded with low contrast regions of interest (ROIs) was designed for both the 0.774 mm diameter 6711 (standard) and the 0.508 mm diameter 9011 (thin) seed models (Oncura, Inc., and GE Healthcare, Arlington Heights, IL). Image quality metrics were assessed using the standard deviation of ROIs between the seeds and the contrast to noise ratio (CNR) within the low contrast ROIs. For US images, water phantoms with both single and multiseed arrangements were constructed for both seed sizes. For MR images, both seeds were implanted into a porcine gel and imaged with pelvic imaging protocols. The standard deviation of ROIs and CNR values were used as metrics of artifact quantification. Seed localization within the CT images was assessed using the automated seed finder in a commercial brachytherapy treatment planning system. The number of erroneous seed placements and the average and maximum error in seed placements were recorded as metrics of the localization accuracy. Results: With the thin seeds, CT image noise was reduced from 48.5 {+-} 0.2 to 32.0 {+-} 0.2 HU and CNR improved by a median value of 74% when compared with the standard seeds. Ultrasound image noise was measured at 50.3 {+-} 17.1 dB for the thin seed images and 50.0 {+-} 19.8 dB for the standard seed images, and artifacts directly behind the seeds were smaller and less prominent with the thin seed model. For MR images, CNR of the standard seeds reduced on average 17% when using the thin seeds for all different imaging sequences and seed orientations, but these differences are not appreciable. Automated seed localization required an average ({+-}SD) of 7.0 {+-} 3.5 manual corrections in seed positions for the thin seed scans and 3.0 {+-} 1.2 manual corrections in seed positions for the standard seed scans. The average error in seed placement was 1.2 mm for both seed types and the maximum error in seed placement was 2.1 mm for the thin seed scans and 1.8 mm for the standard seed scans. Conclusions: The 9011 thin seeds yielded significantly improved image quality for CT and US images but no significant differences in MR image quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-A-17A-11: Implanted Brachytherapy Seed Movement Due to Transrectal Ultrasound Probe-Induced Prostate Deformation

Purpose: To characterize the movement of implanted brachytherapy seeds due to transrectal ultrasound probe-induced prostate deformation and to estimate the effects on prostate dosimetry. Methods: Implanted probe-in and probe-removed seed distributions were reconstructed for 10 patients using C-arm fluoroscopy imaging. The prostate was delineated on ultrasound and registered to the fluoroscopy seeds using a visible subset of seeds and residual needle tracks. A linear tensor and shearing model correlated the seed movement with position. The seed movement model was used to infer the underlying prostate deformation and to simulate the prostate contour without probe compression. Changes in prostate and surrogate urethra dosimetry were calculated. Results: Seed movement patterns reflecting elastic decompression, lateral shearing, and rectal bending were observed. Elastic decompression was characterized by anterior-posterior expansion and superior-inferior and lateral contractions. For lateral shearing, anterior movement up to 6 mm was observed for extraprostatic seeds in the lateral peripheral region. The average intra-prostatic seed movement was 1.3 mm, and the residual after linear modeling was 0.6 mm. Prostate D90 increased by 4 Gy on average (8 Gy max) and was correlated with elastic decompression. For selected patients, lateral shearing resulted in differential change in D90 of 7 Gy between anterior and posterior quadrants, and increase in whole prostate D90 of 4 Gy. Urethra D10 increased by 4 Gy. Conclusion: Seed movement upon probe removal was characterized. The proposed model captured the linear correlation between seed movement and position. Whole prostate dose coverage increased slightly, due to the small but systematic seed movement associated with elastic decompression. Lateral shearing movement increased dose coverage in the anterior-lateral region, at the expense of the posterior-lateral region. The effect on whole prostate D90 was smaller due to the subset of peripheral seeds involved, but lateral shearing movement can have greater consequences for local dose coverage.

60 APPLIED LIFE SCIENCES↗

SU-E-J-215: Towards MR-Only Image Guided Identification of Calcifications and Brachytherapy Seeds: Application to Prostate and Breast LDR Implant Dosimetry

Purpose: To identify and analyze the appearance of calcifications and brachytherapy seeds on magnitude and phase MRI images and to investigate whether they can be distinguished from each other on corrected phase images for application to prostate and breast low dose rate (LDR) implant dosimetry. Methods: An agar-based gel phantom containing two LDR brachytherapy seeds (Advantage Pd-103, IsoAid, 0.8mm diameter, 4.5mm length) and two spherical calcifications (large: 7mm diameter and small: 4mm diameter) was constructed and imaged on a 3T Philips MR scanner using a 16-channel head coil and a susceptibility weighted imaging (SWI) sequence (2mm slices, 320mm FOV, TR/ TE= 26.5/5.3ms, 15 degree flip angle). The phase images were unwrapped and corrected using a 32×32, 2D Hanning high pass filter to remove background phase noise. Appearance of the seeds and calcifications was assessed visually and quantitatively using Osirix (http://www.osirix-viewer.com/). Results: As expected, calcifications and brachytherapy seeds appeared dark (hypointense) relative to the surrounding gel on the magnitude MRI images. The diameter of each seed without the surrounding artifact was measured to be 0.1 cm on the magnitude image, while diameters of 0.79 and 0.37 cm were measured for the larger and smaller calcifications, respectively. On the corrected phase images, the brachytherapy seeds and the calcifications appeared bright (hyperintense). The diameter of the seeds was larger on the phase images (0.17 cm) likely due to the dipole effect. Conclusion: MRI has the best soft tissue contrast for accurate organ delineation leading to most accurate implant dosimetry. This work demonstrated that phase images can potentially be useful in identifying brachytherapy seeds and calcifications in the prostate and breast due to their bright appearance, which helps in their visualization and quantification for accurate dosimetry using MR-only. Future work includes optimizing phase filters to best identify and delineate seeds and calcifications.

60 APPLIED LIFE SCIENCES↗

SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P{sub TP}, may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) for which empirical altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P{sub TP}, were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P{sub TP} can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) with the HDR 1000 Plus well chamber.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-301: Dosimetric Comparison Between Adaptive and Rectilinear Template-Based Prostate Seed Implants

Purpose: To compare the dosimetry of a standard rectilinear and an adaptive technique used in I125 prostate seed implants. Methods: To achieve favorable dosimetry in prostate implants we used adaptive needle updates to match actual positions in real-time. The seed locations were optimized based on actual needle locations. The seeds were delivered automatically with a robotic device seedSelectron™ (Elekta Brachytherapy). In this study, we evaluated the former approach against the standard rectilinear technique in which the needles have a parallel distribution. The treatment plans for 10 patients were analyzed. For comparison, the actual treatment plans were revised so each needle was repositioned to its original parallel location through the template. The analysis was performed by comparing the target coverage and dose to the organs at risk. The comparison was done using the following planning goals: the target D90> 90%, V100% > 90%, V50% <70% and V200% <30%; the urethra V125% < 1cm3 and V150%= 0cm3; and the Rectum V100%<1cm3 and V69% < 8cm3. The prescription dose to the target was 145Gy. Results: The average target volume and number of seeds were 44.39cm3(SD=11.14) and 74(SD=12), respectively. The D90 for adaptive and rectilinear plans was 159.9Gy(SD=2.99) and 155.53Gy(SD=4.04) resulting in a 2.74% difference for the average target coverage. A similar difference (1.75%) was noticed in the target V100[%]. No significant difference was noticed in the dose to the urethra and rectum. All planning goals were met with both the adaptive and rectilinear approach for each plan. Conclusion: The study reveals enhanced coverage of the target when using the adaptive needle adjustments as compared to the rectilinear approach for the analyzed cases. However, the differences in dosimetry did not translate to meaningful clinical outcomes.

60 APPLIED LIFE SCIENCES↗