Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray scanning imaging achieved with bonded multilayer Laue lenses

Here, we report scanning hard x-ray imaging with a monolithic focusing optic consisting of two multilayer Laue lenses (MLLs) bonded together. With optics pre-characterization and accurate control of the bonding process, we show that a common focal plane for both MLLs can be realized at 9.317 keV. Using bonded MLLs, we obtained a scanning transmission image of a star test pattern with a resolution of 50 × 50 nm 2 . By applying a ptychography algorithm, we obtained a probe size of 17 × 38 nm 2 and an object image with a resolution of 13 × 13 nm 2 . Finally, the significant reduction in alignment complexity for bonded MLLs will greatly extend the application range in both scanning and full-field x-ray microscopies.

36 MATERIALS SCIENCE↗

Hydrologic applications of Nimbus 5 ESMR data

A region of low brightness temperature lying along the Mississippi River from Cairo, Illinois, to Morganza, Louisiana was observed in early Nimbus 5 Electrically Scanning Microwave Radiometer images. This region, which generally corresponds to an outwash aquifer in the Mississippi Valley, had brightness temperatures, at times as much as 40 K below the surrounding (drier) older uplands. Fluctuations of as much as 30 K were observed during the time interval 15 December 1972 to 28 February 1973. Comparison images taken from the Earth Resources Technology Satellite indicate that the study area is aligned with the Mississippi River floodplain, a region of potentially high soil moisture content. The brightness temperature fluctuations were compared with variations in precipitation and other hydrologic parameters in order to delineate the causative factors.

Schmugge, T. J.↗

Gregorian all-reflective optical system

An optical heterodyne receiver comprises a system of reflectors forming a folded Gregorian configuration for collecting a signal beam, and an optical detector located at the focus of the system. A paraboloidal primary reflector and an elipsoidal secondary reflector face each other on an optical axis with the focus of the secondary reflector coinciding with the focus of the primary reflector. An auxiliary laser generates a local oscillator beam that is combined with the signal beam after the signal beam emerges from the exit pupil (which is also the aperture stop) of the system, and the resultant is impinged on the detector. A pair of image motion compensators is located as close to the exit pupil as possible for aligning off-axis inputs to the detector.

King, W. L.↗

IAL SPACE: A test laboratory for the ISO cryogenic payload

The ESA Infrared Space Observatory (ISO) satellite is a 3 axes pointed platform designed to make accurate pointed observations of astronomical objects and sources in the wavelength range between 2.5 and 200 microns. ISO is composed of a service module and a payload module which is a large cylindrical vacuum vessel. The vessel is in fact a cryostat (capacity of 2250 l of liquid He II) which contains the telescope and the four focal scientific instruments. The latter being cooled up to a temperature less than 4 K. The qualification of the payload requires the measurement respectively of: the image quality of the telescope through wave front error (WFE) measurements; and the optical alignment of the scientific instruments with respect to the telescope axis and the telescope focus, and this under cryogenic conditions. Consequently, since 1988, the FOCAL 5 IAL Space facility has been upgraded in order to perform the cryogenic optical tests of the ISO optical subsystems.

Cucchiaro, A.↗

Discrete and Diffuse Aurora During Varying Activity Levels: Simultaneous Fast and Polar UVI Observations

We examine simultaneous measurements of auroral electron precipitation obtained in-situ by the FAST spacecraft and remotely by Polar Ultraviolet Imagery (UVI) images for activity levels ranging from quiet to storm-time intervals. The incident energy flux measured by FAST and inferred from the UVI images agree well during quiescent periods, particularly in regions of discrete aurora in which the electron precipitation spectra are dominated by the component accelerated by a field-aligned potential. During magnetospheric substorms and active storm periods, such as those following Coronal Mass Ejection (CME) disturbances of the magnetosphere, the energy flux inferred from the UVI images generally exceeds that measured locally by FAST at the same location by as much as an order of magnitude. The auroral electrons during these active periods are dominated by diffuse precipitation which is observed up the to the highest energy channel of FAST (30 keV). These storm-time observations imply that a high energy component above 30 keV not observed by FAST may be contributing significantly to the total energy flux carried by the precipitating electrons. Observations suggest that as magnetospheric activity increases acceleration processes in the magnetosphere and pitch-angle diffusion by wave-particle interactions become more important than the ionospheric acceleration in producing the measured auroral energy fluxes.

Chua, D.↗

On-orbit performance testing of the Pointing Calibration & Reference Sensor for the Spitzer Space Telescope

We present the on-orbit performance results of the Pointing Calibration and Reference Sensor (PCRS) for the Spitzer Space Telescope. A cryogenic optical (center wavelength 0.55 mu) imager, the PCRS serves as the Observatory's fine guidance sensor by providing an alignment reference between the telescope boresight and the external spacecraft attitude determination system. The PCRS makes precision measurements of the positions of known guide stars; these are used to calibrate measurements from Spitzer's star tracker and gyroscopes to obtain the actual pointing of the Spitzer telescope. The PCRS calibrates out thermomoechanical drifts between the 300 K spacecraft bus and the 5.5 K telescope. By using only 16 pixels, the PCRS provides high precision centroiding with extremely low (`64 mu W) power dissipation, resulting in minimal impact to Spritzer's helium lifetime. We have demonstrated that the PCRS meets its centroiding accuracy requirement of 0.14 arcsec 1-sigma radial, which represents about1/100 pixel centroiding. The Spitzer Space Telescope was launched in 25 August, 2003 and completed its In-Orbit Checkout phase two months later; the PCRS has been operating failure free ever since.

Spitzer↗

The Astro-H Soft X-Ray Mirror

The Astro-H is led by the Japanese Space Agency (JAXA) in collaboration with many other institutions including the NASA Goddard Space Flight Center. Goddard's contributions include two soft X-ray telescopes (SXTs). The telescopes have an effective area of 562 square cm at 1 keV and 425 square cm at 6 keV with an image quality requirement of 1.7 arc-minutes half power diameter (HPD). The engineering model has demonstrated 1.1 arc-minutes HPD error. The design of the SXT is based on the successful Suzaku mission mirrors with some enhancements to improve the image quality. Two major enhancements are bonding the X-ray mirror foils to alignment bars instead of allowing the mirrors to float, and fabricating alignment bars with grooves within 5 microns of accuracy. An engineering model SXT was recently built and subjected to several tests including vibration, thermal, and X-ray performance in a beamline. Several lessons were learned during this testing that will be incorporated in the flight design. Test results and optical performance are discussed, along with a description of the design of the SXT.

Robinson, David↗

Cryogenic Photogrammetry and Radiometry for the James Webb Space Telescope Microshutters

The James Webb Space Telescope (JWST) relies on several innovations to complete its five year mission. One vital technology is microshutters, the programmable field selectors that enable the Near Infrared Spectrometer (NIRSpec) to perform multi-object spectroscopy. Mission success depends on acquiring spectra from large numbers of galaxies by positioning shutter slits over faint targets. Precise selection of faint targets requires field selectors that are both high in contrast and stable in position. We have developed test facilities to evaluate microshutter contrast and alignment stability at their 35K operating temperature. These facilities used a novel application of image registration algorithms to obtain non-contact, sub-micron measurements in cryogenic conditions. The cryogenic motion of the shutters was successfully characterized. Optical results also demonstrated that shutter contrast far exceeds the NIRSpec requirements. Our test program has concluded with the delivery of a flight-qualified field selection subsystem to the NIRSpec bench.

Chambers, Victor J.↗

LUVOIR Primary Mirror Segment Alignment Control With Joint Laser Metrology and Segment Edge Sensing

An approach is developed for the alignment and stability maintenance of the LUVOIR segmented primary mirror using a segment state estimation and wavefront control method based on a hybrid segment motion sensing architecture of laser truss metrology and segment edge sensors. Our current computer model was generated for LUVOIR Architecture Option A with a 15-meter aperture, 120segment primary mirror. The methodology and simulation results will be presented and analyzed. JPL has a long history of technology development in laser metrology and edge sensors, including work in SIM [7], Keck and TMT [8], CCAT [3] and LUVOIR [1]. We will discuss our current efforts of LUVOIR laser metrology and edge-sensor models development, showing sensitivities of sensor measurements to various mirror eigenmodes, removing global modes and strengthening weak modes by performing joint (hybrid) laser-metrology and edge sensing. We will define and derive an important performance metric called wavefront error multiplier (WEM), and show that WEM provides a simple link between sensor errors and the closed-loop (controlled) system wavefront error. We will show WEM values for several hybrid sensor configuration options studied. We will discuss an algorithm for mirror shape control and maintenance through segment state and wavefront estimations using joint edge-metrology sensing. We will compare simulated performance of mirror state estimation, wavefront estimation and wavefront control based on joint edge-metrology sensing among several sensor configurations, and show the impact of sensor error distributions on the segmented mirror alignment performance. Mirror shape control performance will be also be evaluated in terms of imaging contrast between inner working angles (IWA) and outer working angles (OWA) of a LUVOIR coronagraph. The research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration. LUVOIR is a mission concept under study for the next astronomy Decadal Survey—the information presented in this paper is pre-decisional and is provided for planning and discussion purposes only.

Shelton, Chris↗

Technologies to Enable the Next Great Observatory

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is one of four mission concepts being studied by NASA for the 2020 Decadal Survey in Astronomy and Astrophysics. LUVOIR will be capable of a broad range of science, including: direct imaging and characterization of a wide range of exoplanets and the search for biosignatures on Earth-like planets around sun-like stars; studying galaxy formation and evolution; investigating star and planet formation; and remote sensing of bodies within the Solar System. Enabling a mission as ambitious as LUVOIR requires an array of technologies, such as ultra-stable structures and optics, precision metrology and wavefront sensing, high-contrast imaging techniques, large-format detectors with very low noise, and high-throughput ultraviolet instrumentation. Critically, a systems-level approach must be taken to developing these technologies, guided by architecture studies to place each technology in the appropriate system context.In this poster, we describe LUVOIR's technology needs, as well as current efforts that are actively developing these technologies. We will discuss recent advancements in: measuring picometer-level displacements of optical and structural elements; sub-milli-kelvin thermal sensing and control; non-contact vibration isolation for pointing and dynamic stability; coronagraph design for achieving 10-10 contrast on a segmented system; high-speed metrology for optical system alignment; low-order and out-of-band wavefront sensing for maintaining high-contrast images; low-noise detectors across the ultraviolet, optical, and near infrared bands; broadband coatings with high-reflectivity below Ly. We will also describe a systems approach to coordinating the development of these technologies to achieve the necessary maturity for a LUVOIR mission start in the next decade.

space telescopes↗

CHESS 2025: Orthorectified airborne RGB imagery from NEON AOP surveys

This dataset provides Level 1 (L1) and Level 3 (L3) orthorectified Red-Green-Blue (RGB) imagery collected for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). This high-resolution imagery is a photographic record of red, green, and blue visible light from sunlight reflected off of the Earth’s surface. The data comprise full-color images of the ground surface and are primarily intended to provide context to imaging spectroscopy and light detection and ranging (LiDAR) data. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. RGB images were acquired using the PhaseOne IXM-RS150F high-resolution digital camera onboard the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP). The package data include both an L1 product comprising one camera frame per file and an L3 mosaic aligned to the Universal Transverse Mercator (UTM) Zone 13N grid and the World Geodetic System (WGS) 84 projection. Both products are provided in geotif (.tif) format at 0.1 m ground resolution. The bulk of the imagery was collected during the main CHESS field campaign from June 13 to July 15, 2025. Additional images of a portion of the Upper Taylor (UPTA) domain were collected on September 18, 2025, to fill gaps in imagery identified after the main campaign was complete. RGB camera imagery is not radiometrically calibrated, and therefore pixel values should not be exploited for scientific analysis. Pixel values have undergone a manual adjustment to enhance feature identification. The imagery is rigorously geolocated which does allow for reliable geometric information to be retrieved. To generate the orthorectified imagery, the NEON AOP camera captured visible spectrum in red, green, and blue bands. The raw images were then processed using NEON’s camera orthorectification workflow. A boresight calibration flight was made to build a complete camera, distortion, and alignment model. Color balance/white balance and exposure correction were applied to the raw RGB images. The corrected images were orthorectified by ray-tracing image pixels to a lidar-derived digital surface model (DSM) mesh using the refined camera model, outputting orthorectified raster pixels on a regular grid. Flightline-level data were mosaicked by selecting per-pixel contributions from overlapping orthorectified images using line-of-sight (LOS) zenith angle minimization to reduce edge distortions. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

THE DARK ENERGY CAMERA

The Dark Energy Camera is a new imager with a 2.°2 diameter field of view mounted at the prime focus of the Victor M. Blanco 4 m telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses it. The camera consists of a five-element optical corrector, seven filters, a shutter with a 60 cm aperture, and a charge-coupled device (CCD) focal plane of 250 μm thick fully depleted CCDs cooled inside a vacuum Dewar. The 570 megapixel focal plane comprises 62 2k × 4k CCDs for imaging and 12 2k × 2k CCDs for guiding and focus. The CCDs have 15 μm × 15 μm pixels with a plate scale of 0.″263 pixel{sup −1}. A hexapod system provides state-of-the-art focus and alignment capability. The camera is read out in 20 s with 6–9 electron readout noise. This paper provides a technical description of the camera's engineering, construction, installation, and current status.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KILOPARSEC-SCALE JETS IN THREE RADIO-LOUD NARROW-LINE SEYFERT 1 GALAXIES

We have discovered kiloparsec-scale extended radio emission in three narrow-line Seyfert 1 galaxies (NLS1s) in sub-arcsecond resolution 9 GHz images from the Karl G. Jansky Very Large Array. We find all sources show two-sided, mildly core-dominated jet structures with diffuse lobes dominated by termination hotspots. These span 20–70 kpc with morphologies reminiscent of FR II radio galaxies, while the extended radio luminosities are intermediate between FR I and FR II sources. In two cases the structure is linear, while a 45° bend is apparent in the third. Very Long Baseline Array images at 7.6 GHz reveal parsec-scale jet structures, in two cases with extended structure aligned with the inner regions of the kiloparsec-scale jets. Based on this alignment, the ratio of the radio core–luminosity to the optical luminosity, the jet/counter-jet intensity and extension length ratios, and moderate core brightness temperatures (≲10{sup 10} K), we conclude these jets are mildly relativistic (β≲0.3, δ∼1−1.5) and aligned at moderately small angles to the line of sight (10–15°). The derived kinematic ages of ∼10{sup 6}–10{sup 7} yr are much younger than radio galaxies but comparable to other NLS1s. Our results increase the number of radio-loud NLS1s with known kiloparsec-scale extensions from 7 to 10 and suggest that such extended emission may be common, at least among the brightest of these sources.

79 ASTRONOMY AND ASTROPHYSICS↗

On-axis microscopes for the inelastic x-ray scattering beamline at NSLS-II

A novel on-axis X-ray microscope with 3 µm resolution, 3x magnification, and a working distance of 600 mm for in-situ sample alignment and X-ray beam visualization for the Inelastic X-ray Scattering (IXS) beamline at NSLS-II is presented. The microscope uses reflective optics, which minimizes dispersion, and allows imaging from Ultraviolet (UV) to Infrared (IR) with specifically chosen objective components (coatings, etc.). Additionally, a portable high resolution X-ray microscope for KB mirror alignment and X-ray beam characterization was developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the relation between photospheric flow fields and the magnetic field distribution on the solar surface

Using the technique of local correlation tracking on a 28 minute time sequence of white-light images of solar granulation, the horizontal flow field on the solar surface is measured. The time series was obtained by the Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 (Space Shuttle flight 51-F) and is free from atmospheric blurring and distortion. The SOUP flow fields have been compared with carefully aligned magnetograms taken over a nine hour period at the Big Bear Solar Observatory before, during, and after the SOUP images. The flow field and the magnetic field agree in considerable detail: vectors which define the flow of the white-light intensity pattern (granulation) point toward magnetic field regions, magnetic fields surround flow cells, and magnetic features move along the flow arrows. The projected locations of free particles ('corks') in the measured flow field congregate at the same locations where the magnetic field is observed.

Simon, George W.↗

TH-A-18C-10: Dynamic Intensity Weighted Region of Interest Imaging

Purpose: For image guidance tasks full image quality is not required throughout the entire image. With dynamic filtration of the kV imaging beam the noise properties of the CT image can be locally controlled, providing a high quality image around the target volume with a lower quality surrounding region while providing substantial dose sparing to the patient as well as reduced scatter fluence on the detector. Methods: A dynamic collimation device with 3mm copper blades has been designed to mount in place of the bowtie filter on the On-Board Imager (Varian Medical Systems). The beam intensity is reduced by 95% behind the copper filters and the aperture is controlled dynamically to conformally illuminate a given ROI during a standard cone-beam CT scan. A data correction framework to account for the physical effects of the collimator prior to reconstruction was developed. Furthermore, to determine the dose savings and scatter reduction a monte carlo model was built in BEAMnrc with specifics from the Varian Monte Carlo Data Package. The MC model was validated with Gafchromic film. Results: The reconstructed image shows image quality comparable to a standard scan in the specified ROI, with higher noise and streaks in the outer region but still sufficient information for alignment to high contrast structures. The monte carlo modeling showed that the scatter-to-primary ratio was reduced from 1.26 for an unfiltered scan to 0.45 for an intensity weighted scan, suggesting that image quality may be improved in the inner ROI. Dose in the inner region was reduced 10–15% due to reduced scatter and by as much as 75% in the outer region. Conclusion: Dynamic intensity-weighted ROI imaging allows reduction of imaging dose to sensitive organs away from the target region while providing images that retain their utility for patient setup and procedure guidance. Funding was provided in part by Varian Medical Systems and NIH Grants 1RO1CA120540, T32EB002103, S10 RR021039 and P30 CA14599. The contents of this work are solely the responsibility of the authors and do not necessarily represent the official views of any of the supporting organizations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Non-invasive optical method for rapid determination of alignment degree of oriented nanofibrous layers

This paper presents a rapid non-destructive method that provides information on the anisotropic internal structure of nanofibrous layers. A laser beam of a wavelength of 632.8 nm is directed at and passes through a nanofibrous layer prepared by electrostatic spinning. Information about the structural arrangement of nanofibers in the layer is directly visible in the form of a diffraction image formed on a projection screen or obtained from measured intensities of the laser beam passing through the sample which are determined by the dependency of the angle of the main direction of polarization of the laser beam on the axis of alignment of nanofibers in the sample. Both optical methods were verified on Polyvinyl alcohol (PVA) nanofibrous layers (fiber diameter of 470 nm) with random, single-axis aligned and crossed structures. The obtained results match the results of commonly used methods which apply the analysis of electron microscope images. The presented simple method not only allows samples to be analysed much more rapidly and without damaging them but it also makes possible the analysis of much larger areas, up to several square millimetres, at the same time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗