Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat transfer performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Prediction of self-pressurization rate of cryogenic propellant tankage

The SOLA-ECLIPSE code is being developed to enable prediction of the behavior of cryogenic propellants in spacecraft tankage. A brief description of the formulations used for modeling heat transfer and for determining the thermodynamic state is presented. Code performance is verified through comparison to experimental data for the self-pressurization of scale-model liquid hydrogen tanks. SOLA-ECLIPSE is used to examine the effect of initial subcooling of the liquid phase on the self-pressurization rate of an on-orbit full-scale liquid hydrogen tank typical for a chemical-propulsion orbit transfer vehicle. The computational predictions show that even small amounts of subcooling will significantly decrease the self-pressurization rate. Further, if the cooling is provided by a thermodynamic vent system, it is concluded that small levels of subcooling will maximize propellant conservation.

Hochstein, John I.↗

Thermodynamic aspects of heat pipe operation

An expanded heat pipe operating model is described which includes thermodynamic and heat transfer considerations to reconcile disparities between actual and theoretical heat pipe performances. The analysis shows that thermodynamic considerations can explain the observed heat pipe performance limitations. A full understanding of thermodynamic processes could lead to advanced concepts for thermal transport devices.

Richter, Robert↗

Numerical investigation on Benard instability in a finite liquid layer

A numerical procedure for directly simulating the Benard-Marangoni instabilities (B-M-I) in a bounded liquid layer is presented in this paper. The procedure consists of applying a finite amplitude disturbance to the basic static state, and then integrating the Navier-Stokes equations to determine whether the disturbance will die down or will reach a state of finite-strength steady convection. The critical Marangoni number (Mac) for the onset of B-M-I can thus be determined and can be correlated as a function of the aspect ratio (Ar), Prandtl number (Pr), and Rayleigh number (Ra). The Biot number (B) between the liquid and the air is analyzed to approximate the heat transfer condition along the free surface. A 2D calculation is performed to investigate the effect of various initial disturbances, and the Mac is determined for Ar = 2, Ra = 0, and Pr = 0.7. Current results show that disturbances of different nature and amplitude have little effect on Mac. The Mac determined in this study also clearly demonstrates the dominant effect of the sidewalls.

Duh, J. C.↗

Modern Experimental Techniques in Turbine Engine Testing

The paper describes application of two modern experimental techniques, thin-film thermocouples and pressure sensitive paint, to measurement in turbine engine components. A growing trend of using computational codes in turbomachinery design and development requires experimental techniques to refocus from overall performance testing to acquisition of detailed data on flow and heat transfer physics to validate these codes for design applications. The discussed experimental techniques satisfy this shift in focus. Both techniques are nonintrusive in practical terms. The thin-film thermocouple technique improves accuracy of surface temperature and heat transfer measurements. The pressure sensitive paint technique supplies areal surface pressure data rather than discrete point values only. The paper summarizes our experience with these techniques and suggests improvements to ease the application of these techniques for future turbomachinery research and code verifications.

Lepicovsky, J.↗

A Three-Dimensional Coupled Internal/External Simulation of a Film-Cooled Turbine Vane

A three-dimensional Navier-Stokes simulation has been performed for a realistic film-cooled turbine vane using the LeRC-HT code. The simulation includes the flow regions inside the coolant plena and film cooling holes in addition to the external flow. The vane is the subject of an upcoming NASA Glenn Research Center experiment and has both circular cross-section and shaped film cooling holes. This complex geometry is modeled using a multi-block grid which accurately discretizes the actual vane geometry including shaped holes. The simulation matches operating conditions for the planned experiment and assumes periodicity in the spanwise direction on the scale of one pitch of the film cooling hole pattern. Two computations were performed for different isothermal wall temperatures, allowing independent determination of heat transfer coefficients and film effectiveness values. The results indicate separate localized regions of high heat transfer coefficient values, while the shaped holes provide a reduction in heat flux through both parameters. Hole exit data indicate rather simple skewed profiles for the round holes, but complex profiles for the shaped holes with mass fluxes skewed strongly toward their leading edges.

Heidmann, James D.↗

Space Suit Thermal Dynamics

The present NASA space suit (the Shuttle EMU) is a self-contained environmental control system, providing life support, environmental protection, earth-like mobility, and communications. This study considers the thermal dynamics of the space suit as they relate to astronaut thermal comfort control. A detailed dynamic lumped capacitance thermal model of the present space suit is used to analyze the thermal dynamics of the suit with observations verified using experimental and flight data. Prior to using the model to define performance characteristics and limitations for the space suit, the model is first evaluated and improved. This evaluation includes determining the effect of various model parameters on model performance and quantifying various temperature prediction errors in terms of heat transfer and heat storage. The observations from this study are being utilized in two future design efforts, automatic thermal comfort control design for the present space suit and design of future space suit systems for Space Station, Lunar, and Martian missions.

Campbell, Anthony B.↗

CFD Analysis of Thermal Control System Using NX Thermal and Flow

The Thermal Control Subsystem (TCS) is a key part of the Advanced Plant Habitat (APH) for the International Space Station (ISS). The purpose of this subsystem is to provide thermal control, mainly cooling, to the other APH subsystems. One of these subsystems, the Environmental Control Subsystem (ECS), controls the temperature and humidity of the growth chamber (GC) air to optimize the growth of plants in the habitat. The TCS provides thermal control to the ECS with three cold plates, which use Thermoelectric Coolers (TECs) to heat or cool water as needed to control the air temperature in the ECS system. In order to optimize the TCS design, pressure drop and heat transfer analyses were needed. The analysis for this system was performed in Siemens NX Thermal/Flow software (Version 8.5). NX Thermal/Flow has the ability to perform 1D or 3D flow solutions. The 1D flow solver can be used to represent simple geometries, such as pipes and tubes. The 1D flow method also has the ability to simulate either fluid only or fluid and wall regions. The 3D flow solver is similar to other Computational Fluid Dynamic (CFD) software. TCS performance was analyzed using both the 1D and 3D solvers. Each method produced different results, which will be evaluated and discussed.

CFD↗

Investigating the Ability of Plastic Current Collectors to Isolate Internal Shorts

Metallized plastic current collectors in Li-ion cells reduce mass and reduce the internal short circuit hazard compared to aluminum and copper foils. Shorts induced by nail and by our internal short circuit device were performed on control 18650 cells and on cells with the collectors replaced with metallized polyester and aramid films. Tests were performed inside our fractional thermal runaway calorimeter to quantify the heat transferred and its distributions and those runs done at a synchrotron yielded fascinating very high speedX-ray videography. These show tolerance to nail penetration and activation of defect internal shorts and when thermally forced into thermal runaway, the heat output is significantly reduced. Very high resolutionCT scans, cross sections, and cell tear downs give insights into the thermal and mechanism for these plastic collectors.

Plastic Current Collectors↗

Development and Performance of RFD Crab Cavity Prototypes for HL-LHC AUP

The US will be contributing to the HL-LHC upgrade at CERN with the fabrication and qualification of RFD crabbing cavities in the framework of the HL-LHC Accelerator Upgrade Project (AUP) managed by Fermilab. AUP received Critical Decision 3 (CD-3) approval by DOE in December 2020 launching the project into the production phase. The electro-magnetic design of the cavity was inherited from the LHC Accelerator Research Program (LARP) but needed to be revised to meet new project requirements and to prevent issues encountered during beam tests performed at CERN in the R&D phase. Two prototype cavities were manufactured in industry and cold tested. Challenges specific to the RFD cavity were the stringent interface tolerances, the pole symmetry, and the higher-order-mode impedance spectrum. Chemical processing and heat treatments were performed initially at FNAL/ANL and are now being transferred to industry for the production phase. HOM dampers are manufactured and validated by JLAB. A summary of cold test results with and without HOM dampers is presented.

43 PARTICLE ACCELERATORS↗

NASA Ares I Launch Vehicle First Stage Roll Control System Cold Flow Development Test Program Overview

The Ares I launch vehicle is the selected design, chosen to return humans to the moon, Mars, and beyond. It is configured in two inline stages: the First Stage is a Space Shuttle derived five-segment Solid Rocket Booster and the Upper Stage is powered by a Saturn V derived J-2X engine. During launch, roll control for the First Stage (FS) is handled by a dedicated Roll Control System (RoCS) located on the connecting Interstage. That system will provide the Ares I with the ability to counteract induced roll torque while any induced yaw or pitch moments are handled by vectoring of the booster nozzle. This paper provides an overview of NASA s Ares I FS RoCS cold flow development test program including detailed test objectives, types of tests run to meet those objectives, an overview of the results, and applicable lessons learned. The test article was built and tested at the NASA Marshall Space Flight Center in Huntsville, AL. The FS RoCS System Development Test Article (SDTA) is a full scale, flight representative water flow test article whose primary objective was to obtain fluid system performance data to evaluate integrated system level performance characteristics and verify analytical models. Development testing and model correlation was deemed necessary as there is little historical precedent for similar large flow, pulsing systems such as the FS RoCS. The cold flow development test program consisted of flight-similar tanks, pressure regulators, and thruster valves, as well as plumbing simulating flight geometries, combined with other facility grade components and structure. Orifices downstream of the thruster valves were used to simulate the pressure drop through the thrusters. Additional primary objectives of this test program were to: evaluate system surge pressure (waterhammer) characteristics due to thruster valve operation over a range of mission duty cycles at various feed system pressures, evaluate temperature transients and heat transfer in the pressurization system, including regulator blowdown and propellant ullage performance, measure system pressure drops for comparison to analysis of tubing and components, and validate system activation and re-activation procedures for the helium pressurant system. Secondary objectives included: validating system processes for loading, unloading, and purging, validating procedures and system response for multiple failure scenarios, including relief valve operation, and evaluating system performance for contingency scenarios. The test results of the cold flow development test program are essential in validating the performance and interaction of the Roll Control System and anchoring analysis tools and results to a Critical Design Review level of fidelity.

Butt, Adam↗

A Combined Water and CO2 Direct Air Capture System (CRADA 521)

The primary objective of this project is to demonstrate the outstanding technical and economic performance of a transformational Hybrid DAC (HDAC) technology that simultaneously captures CO2 and water from the air. Air is passed over a CO2 selective sorbent to remove ≥85% of the CO2 from the air stream. The atmospheric water extraction (AWE) section of the unit utilizes a novel isothermal pressure swing regeneration cycle with desiccant beds thermally coupled by heat pipes that provide a passive heat transfer mechanism to “cancel” the heat of water vapor adsorption. By proving system performance through this demonstration project, our initial technoeconomic analysis (TEA) will be validated, showing that HDAC technology: 1) is deployable in many more locations with limited water resources, 2) improves the financial returns, and 3) reduces risks from volatility in the price of CO2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow Assisted Evaporative Cooling for Electric Motor

This paper examines a novel concept of flow assisted latent heat driven two-phase evaporative cooling (EC) confined in-between slot liner and active-winding of electric motor. Wicking micro-structure enhanced PDMS liner axially sucks coolant in the form of thin film between the PDMS liner and active-winding and eventually enables thin film evaporation on the outer surface of the active-winding. Therefore, EC based thermal management eliminates contact resistance between the winding and slot-liner and, enhances the heat extraction from the winding without compromising the electro-magnetic performance. Two-way coupled electro-magnetic (EM) – computational fluid dynamics/heat transfer (CFD/HT) and EM - lumped parameter thermal network (LPTN) models have been developed to assess the electro-thermal performance of the EC under steady and transient conditions. Taking a case study of a 125 kW jacket cooled BMW i3 motor and dielectric coolant FC-84, EC is shown to be capable of handling a maximum steady state rms current density of 26 A/mm2 at a evaporative heat transfer coefficient of 5,000 W/m2.K, which is about 78.7% higher compared to the traditional jacket cooling (JC). In case of EC, a maximum steady state and transient rms current density of 30 A/mm2 (106.2% higher compared to the JC), and 40.8 A/mm2 have been realized by using high thermal conductivity epoxy (1.9 W/m.K) impregnation material. Thermal performance of the EC is also assessed and compared with JC over a dynamic drive cycle. Lastly, a motorette testing has been performed to demonstrate the applicability of the proposed EC method and to validate the developed modeling framework.

42 ENGINEERING↗

Improving the modeling of near-wall interphase heat transfer in porous media models of Pebble Bed Reactors

Here, this work aims to improve capabilities for modeling localized effects in porous media models of Pebble Bed Reactors. The wall-channeling effect is the primary local phenomenon of interest in a PBR, where the presence of the reflector wall disrupts the pebble packing, causing the pebbles near the wall to pack less efficiently and creating large void regions. Accurate modeling of the near-wall region is important as it will affect core bypass flow and temperature predictions. Porous media models are commonly used for design scoping and plant-level simulations of PBRs. Although these models have some capabilities to model the near-wall region, the correlations that are available in porous media codes are often inaccurate when a multi-region model is used to discretize the near-wall region. This work employs a high-to-low analysis to study the accuracy of available interphase heat transfer closures. NekRS, a spectral element computational fluid dynamics code, is used to perform Large Eddy Simulations. These LES simulation results are compared to porous media model results from the Pronghorn porous media code. The friction term of the KTA drag closure is first improved, reducing the error in the prediction of the near-wall velocity from over 50% to less than 5%. This is combined with improvements to the form term from previous works to produce a drag closure that is capable of accurately modeling the wall-channeling effect across a variety of flow conditions. The Nusselt number predictions of several heat transfer correlations are compared to the high-fidelity results where it is found that the KTA heat transfer correlation is capable of accurately predicting the local Nusselt numbers that were determined in the high-fidelity simulation. Comparison of the radial solid temperature profiles, however, reveal discrepancies between NekRS and Pronghorn. It is discovered that the implementation of the interphase heat transfer coefficient that exists in many current porous media codes is not valid when local porosities are modeled. Instead, it is suggested that the interphase heat transfer coefficient should be dependent on the local porosity, the Nusselt number, and the local solid surface-to-volume ratio. Implementation of this change produces improvement in the agreement between the results obtained by NekRS and Pronghorn while using the KTA heat transfer correlation.

interphase heat transfer↗

SHOOT performance testing

The Superfluid Helium On-Orbit Transfer (SHOOT) Flight Demonstration is a shuttle attached payload designed to demonstrate the technology necessary to resupply liquid helium dewars in space. Many SHOOT components will also have use in other aerospace cryogenic systems. The first of two SHOOT dewar systems has been fabricated. The ground performance testing of this dewar is described. The performance tests include measurements of heat leak, impedances of the two vent lines, heat pulse mass gauging accuracy, and superfluid transfer parameters such as flow rate and efficiency. A laboratory dewar was substituted for the second flight dewar for the transfer tests. These tests enable a precise analytical model of the transfer process to be verified. SHOOT performance is thus quantified, except for components such as the liquid acquisition devices and a phase separator which cannot be verified in one gravity.

Dipirro, M. J.↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Long term performance of vacuum insulation panels integrated into building components

Vacuum insulation panels provide much greater resistance to heat transfer than conventional insulation materials, making them ideal for building applications, especially where space is a constraint. Of particular interest is energy retrofits where high insulation values are required with very little or no modifications to existing building envelope elements such as fenestrations and service penetrations. To facilitate the use of vacuum insulation panels (VIPs) in residential and commercial construction, this study investigates the performance of VIPs integrated into polyisocyanurate foam board and vinyl siding after several years of service. Vacuum insulation panels integrated with polyisocyanurate boards were studied in mixed humid and cold climates. The integration of VIPs with vinyl siding was investigated in a mixed humid climate. Periods of service were between two and five years. In all cases, the integrated building components outperformed conventional materials by almost 40 percent during heating and cooling periods. However, the percent reduction in heat gains and losses of the integrated building components decreased with time at a rate between approximately 4% and 10% per year during the service period. In some cases, the rate seems to converge to a steady -state value. Measurements are ongoing to determine if a steady-state value is attained or the panel's insulation value continues to decrease with time. This study is critical in addressing the service life and durability of the building envelope with VIP integrated building components. The effect of these changes will be reviewed in the context of an exterior retrofit.

Aldykiewicz Jr, Antonio↗

Explainable machine learning for incipient anomaly detection in compact molten salt heat exchanger with overlapping feature distributions

High-temperature molten salt-cooled reactors (MSCRs) are a promising next-generation nuclear technology option, offering efficient power conversion and inherent safety features. However, the reliability of these systems depends on the robust operation of heat exchangers (HXs), which are susceptible to failure due to temperature gradients and channel plugging caused by fluid freezing. Conventional monitoring methods, relying on inlet and outlet measurements, lack the spatial resolution needed to detect early-stage faults. We propose a novel design of a compact salt-to-salt matrix-type HX design consisting of interleaved arrays of parallel tubes, with integrated synthetic fiber optic distributed temperature sensing (DTS) to enable localized detection of incipient faults. To evaluate performance of this design, we generate high-fidelity synthetic data using heat transfer computational modeling to simulate channel plugging, and introduce sensor noise for realistic modeling of measurements. The dataset comprises of 97% normal operation and 3% anomaly cases, with each anomaly class representing 1% of the data. These early anomalies result in overlapping temperature profiles between normal and faulty channels, producing a non-separable dataset that challenges traditional classification techniques. We benchmark eight supervised machine learning (ML) models and demonstrate that XGBoost achieves the highest performance. To improve transparency, we develop an explainability framework combining Shapley values and partially ordered sets (POSETs) to quantify and structurally analyze feature importance. This approach identifies both dominant predictors and ambiguous feature relationships, enhancing trust and interpretability. Our results highlight the potential of combining DTS and explainable ML with intelligent feature selection to improve predictive maintenance and ensure operational resilience in advanced nuclear systems.

Prantikos, Konstantinos [Argonne National Laborato↗

RP-2 Thermal Stability and Heat Transfer Investigation for Hydrocarbon Boost Engines

A series of electrically heated tube tests were performed at the NASA Glenn Research Center s Heated Tube Facility to investigate the use of RP-2 as a fuel for next generation regeneratively cooled hydrocarbon boost engines. The effect that test duration, operating condition and test piece material have on the overall thermal stability and materials compatibility characteristics of RP-2 were evaluated using copper and 304 stainless steel test sections. The copper tests were run at 1000 psia, heat flux up to 6.0 Btu/in.2-sec, and wall temperatures up to 1180 F. Preliminary results, using measured wall temperature as an indirect indicator of the carbon deposition process, show that in copper test pieces above approximately 850 F, RP-2 begins to undergo thermal decomposition resulting in local carbon deposits. Wall temperature traces show significant local temperature increases followed by near instantaneous drops which have been attributed to the carbon deposition/shedding process in previous investigations. Data reduction is currently underway for the stainless steel test sections and carbon deposition measurements will be performed in the future for all test sections used in this investigation. In conjunction with the existing thermal stability database, these findings give insight into the feasibility of cooling a long life, high performance, high-pressure liquid rocket combustor and nozzle with RP-2.

VanNoord, J. L.↗