Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Towards Thermomechanical Processing of Alloy 709: Progress in Defining High-Temperature Deformation-Recrystallization "Space"

The Advanced Reactor Technologies (ART) Program has established a multi-year plan to develop Alloy 709 advanced stainless steel, generate the data package and develop material-specific design parameters in qualifying it as a new structural material for Class A construction in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section III, Division 5, High Temperature Reactors (ASME 2025). In collaboration with material vendors, the Advanced Materials Development activities under ART have successfully scaled the Alloy 709 plate form production from a laboratory heat of 500 pounds to commercial heats totaling 133,000 pounds of Alloy 709 plate fabricated from three heats. The goal of the overall Alloy 709 development program is to establish the necessary microstructural and mechanical properties relationship for Alloy 709 to ultimately develop fabrication parameters for other product forms such as bars, pipes, and forgings using the available ART Alloy 709 materials. This study will enable its deployment in the industry as an advanced construction material for high-temperature components. The objective of this Alloy 709 development work in FY 2025 is to experimentally determine the high-temperature deformation-recrystallization response of the Alloy 709 heats and to experimentally generate true stress-true strain data for Alloy 709 using the available commercial heat plate materials. Integral to this work is the previous characterization of the as-rolled materials and the determination of an effective solution-annealing process, which was reported in Y. Wang et al., 2023, and the evaluation of the effect of controlled cooling on the resultant precipitation in these commercial heats. This report summarizes and builds on the results of the previous reports to assess the high-temperature deformation behavior as a function of deformation temperature, strain and strain rate using commercial Alloy 709 heat 58776-3RB fabricated by G. O. Carlson and heat 529900-02 fabricated by Allegheny Technologies Incorporated (ATI) Specialty Rolled Products.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Techno-Economic Analysis of a Concentrating Solar Power Plant Using Redox-Active Metal Oxides as Heat Transfer Fluid and Storage Media

We present results for a one-dimensional quasi-steady-state thermodynamic model developed for a 111.7 MW e concentrating solar power (CSP) system using a redox-active metal oxide as the heat storage media and heat transfer agent integrated with a combined cycle air Brayton power block. In the energy charging and discharging processes, the metal oxide CaAl 0.2 Mn 0.8 O 2.9-δ (CAM28) undergoes a reversible, high temperature redox cycle including an endothermic oxygen-releasing reaction and exothermic oxygen-incorporation reaction. Concentrated solar radiation heats the redox-active oxide particles under partial vacuum to drive the reduction extent deeper for increased energy density at a fixed temperature, thereby increasing storage capacity while limiting the required on sun temperature. Direct counter-current contact of the reduced particles with compressed air from the Brayton compressor releases stored chemical and sensible energy, heating the air to 1,200°C at the turbine inlet while cooling and reoxidizing the particles. The cool oxidized particles recirculate through the solar receiver subsystem for another cycle of heating and reduction (oxygen release). We applied the techno-economic model to 1) size components, 2) examine intraday operation with varying solar insolation, 3) estimate annual performance characteristics over a simulated year, 4) estimate the levelized cost of electricity (LCOE), and 5) perform sensitivity analyses to evaluate factors that affect performance and cost. Simulations use hourly solar radiation data from Barstow, California to assess the performance of a 111.7 MW e system with solar multiples (SMs) varying from 1.2 to 2.4 and storage capacities of 6–14 h. The baseline system with 6 h storage and SM of 1.8 has a capacity factor of 54.2%, an increase from 32.3% capacity factor with no storage, and an average annual energy efficiency of 20.6%. Calculations show a system with an output of 710 GWh e net electricity per year, 12 h storage, and SM of 2.4 to have an installed cost of $329 million, and an LCOE of 5.98 ¢/kWh e . This value meets the U.S. Department of Energy’s SunShot 2020 target of 6.0 ¢/kWh e ( U. S Department of Energy, 2012 ), but falls just shy of the 5.0 ¢/kWh e 2030 CSP target for dispatchable electricity ( U. S Department of Energy, 2017 ). The cost and performance results are minimally sensitive to most design parameters. However, a one-point change in the weighted annual cost of capital from 8 to 7% (better understood as a 12.5% change) translates directly to an 11% decrease (0.66 ¢/kWhe) in the LCOE.

Gorman, Brandon T.↗

Report on FY 2023 Experimental Results in Developing the Fabrication Parameters for Alloy 709 in Different Product Forms

The Advanced Reactor Technologies (ART) Program has established a multi-year plan to develop Alloy 709 advanced stainless steel (A709), generate the data package and develop material-specific design parameters in qualifying it as a new structural material for Class A construction in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section III, Division 5, High Temperature Reactors (ASME 2023). In collaboration with material vendors, the Advanced Materials Development activities under ART have successfully scaled the A709 plate form production from a laboratory heat of 500 pounds to commercial heats totaling 133,000 pounds of A709 plate fabricated from three heats. The goal of the overall A709 development program is to establish the necessary microstructural and mechanical properties relationship for A709 to ultimately develop fabrication parameters for other product forms such as bars, pipes, and forgings using the available ART A709 materials. The objective of this A709 development work in FY 2023 is to experimentally determine grain coarsening behavior for the A709 heats and to experimentally generate the continuous cooling precipitation (CCP) diagram for A709 using the as-rolled commercial heat plate materials. Integral to this work is the characterization of the as-rolled materials and the determination of an effective solution-annealing process, which was reported in Y. Wang et al., 2023. This report summarizes the results of the high-speed dilatometry project to develop the CCP diagram using the commercial heat 58776-3RB fabricated by G. O. Carlson and heat 529900-02 fabricated by Allegheny Technologies Incorporated (ATI) Specialty Rolled Products.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coupled Thermoelasticity Problem for Multilayer Composite Shells of Revolution. I. Theoretical Aspects of the Problem

On the basis of a general integral form of the variational principle of the least possible dissipation of energy of the nonequilibrium thermodynamics, we deduce a nonclassical nonsteady heat-conduction equation for multilayer polyreinforced shells of any shape. A method for the determination of the integral heat conductivities of reinforced layers is developed and the effective constitutive equations for the description of its thermoelastic behavior are proposed. A nonclassical model of deformation of the multilayer shell and a nonlinear model of distribution of the heat flux along the thickness of the layer are formulated. This allows us to take into account the transverse shear strains and guarantee the conditions of thermomechanical contact of the layers and the conditions of thermomechanical loading on the face surfaces of the shell. We construct a closed system of differential equations with the corresponding initial and boundary conditions for a coupled problem of thermoelastic deformation of layered composite shells and plates.

42 ENGINEERING↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Heat transfer tests of an 0.006-scale thin-skin space shuttle thermocouple model (41-OTS) in the Langley Research Center unitary plan wind tunnel at M equals 3.7 (IH16)

The results are presented of supersonic heat transfer tests performed on the .006 scale space shuttle vehicle model (41-OTS) in the Langley Research Center Unitary Plan Wind Tunnel. These tests were conducted to parametrically investigate ascent heating of the integrated vehicle and its components. The tests were conducted at a nominal Mach number of 3.7 and Reynolds numbers per foot of 2 and 5 million. The model configurations investigated were the integrated vehicle and each component alone (i.e. orbiter, tank and SRB). All the configurations were run with and without transition strips and through an angle of attack range of 0 deg to minus 5 deg with the exception of the SRB which was tested through an angle of attack range of minus 5 deg to 90 deg. The heat transfer data were obtained from 223 iron constantan thermocouples attached to stainless steel thin-skin areas of the model.

Walstad, D. G.↗

Plan evaluation for heat resilience: complementary methods to comprehensively assess heat planning in Tempe and Tucson, Arizona

Abstract Escalating impacts from climate change and urban heat are increasing the urgency for communities to equitably plan for heat resilience. Cities in the desert Southwest are among the hottest and fastest warming in the U.S., placing them on the front lines of heat planning. Urban heat resilience requires an integrated planning approach that coordinates strategies across the network of plans that shape the built environment and risk patterns. To date, few studies have assessed cities’ progress on heat planning. This research is the first to combine two emerging plan evaluation approaches to examine how networks of plans shape urban heat resilience through case studies of Tempe and Tucson, Arizona. The first methodology, Plan Quality Evaluation for Heat Resilience, adapts existing plan quality assessment approaches to heat. We assess whether plans meet 56 criteria across seven principles of high-quality planning and the types of heat strategies included in the plans. The second methodology, the Plan Integration for Resilience Scorecard™ (PIRS™) for Heat, focuses on plan policies that could influence urban heat hazards. We categorize policies by policy tool and heat mitigation strategy and score them based on their heat impact. Scored policies are then mapped to evaluate their spatial distribution and the net effect of the plan network. The resulting PIRS™ for Heat scorecard is compared with heat vulnerability indicators to assess policy alignment with risks. We find that both cities are proactively planning for heat resilience using similar plan and strategy types, however, there are clear and consistent opportunities for improvement. Combining these complementary plan evaluation methods provides a more comprehensive understanding of how plans address heat and a generalizable approach that communities everywhere could use to identify opportunities for improved heat resilience planning.

Environmental Sciences & Ecology↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Analysis of orbital heat transfer

Graphical representation of orbital heat balance in form of polar diagrams is obtained from integral expressions of orbital heat transfer whereby quantities of heat are represented as areas swept by ""thermal radii.''

Buna, T.↗

Incorporation of metal nanoparticles into wood substrate and methods

Metal nanoparticles were incorporated into wood. Ionic liquids were used to expand the wood cell wall structure for nanoparticle incorporation into the cell wall structure. Nanoparticles of elemental gold or silver were found to be effective surface enhanced Raman spectroscopy (SERS) imaging contrast or sensing agents. Nanoparticles of elemental iron were found to be efficient microwave absorbers and caused localized heating for disrupting the integrity of the lignocellulosic matrix. Controls suggest that the localized heating around the iron nanoparticles reduces losses of cellulose in the form of water, volatiles and CO.sub.2. The ionic liquid is needed during the incorporation process at room temperature. The use of small amounts of ionic liquid combined with the absence of an ionic liquid purification step and a lower energy and water use are expected to reduce costs in an up-scaled pretreatment process.

59 BASIC BIOLOGICAL SCIENCES↗

Primary System Test Facility Review

Idaho National Laboratory (INL) is designing a Dynamic Energy Transport and Integration Laboratory (DETAIL) to demonstrate the operation of an integrated energy system as part of supporting research and development needs for the DOE Office of Nuclear Energy Integrated Energy Systems (IES) Program. DETAIL will demonstrate real-time integration with the electrical grid, renewable energy inputs, thermal and electrical energy storage, and energy delivery to an end user. A Thermal Energy Distribution System (TEDS) is being constructed within the DETAIL facility to demonstrate the operation of integrated energy system heat transfer components, thermal energy storage, distribution systems, and instrumentation and control (I&C), which will allow the facility to emulate the distribution of thermal energy to the generation of electrical power, and/or producing non-electrical commodities (e.g., hydrogen). As is the case for other subsystems within DETAIL, TEDS is designed to operate either independently or as a part of an integrated system to demonstrate the operation of integrated components, develop and validate thermal energy transport models and control systems, and study thermal energy inertia and energy storage. In an effort to completely understand how TEDS will integrate with operational plants, data from tests previously run at existing integral system test facilities (IST) will be used to drive the TEDS heater. Alternatively, a real-time data connection would allow steam conditions at the IST to drive the TEDS heater at the same time as having TEDS conditions provide feedback to the IST in terms of steam demand and/or pressure. This integrated testing approach will assess the ability of TEDS to operate during all plant conditions. Three existing integral system test facilities have been reviewed to determine their suitability for demonstrating TEDS capabilities when integrated within the DETAIL. This report summarizes the capabilities of each IST facility and any challenges that must be overcome to meet the operational needs of TEDS and DETAIL.

25 ENERGY STORAGE↗

Development of a gas pressure bonded four-pole alternator rotor

Methods were developed for fabrication of a solid four pole alternator rotor by hot isostatic pressure welding. The rotor blanks welded in this program had complex geometrical mating interfaces and were of considerable bulk, being approximately 3-1/2 inches (0.089 meters) in diameter and 14 inches (0.356 meters) long. Magnetic end pieces were machined from AlSl 4340 steel, while the non-magnetic central section was of Inconel 718. Excellent welds were produced which were shown to be responsive to post weld heat treatments which substantially improved joint strength. Prior to welding the rotors, test specimens of complex geometry were welded to demonstrate that complex surfaces with intentional mechanical misfit could be readily joined using HIP welding. This preliminary work demonstrated not only that interface compliance is achieved during welding but that welding pressure is developed in these thick sections sufficient to produce sound joints. Integral weld-heat treatment cycles were developed that permitted the attainment of magnetic properties while minimizing residual stress associated with the allotropic transformation of 4340 steel.

Lessmann, G. G.↗

Active Metal Brazing and Adhesive Bonding of Titanium to C/C Composites for Heat Rejection System

Robust assembly and integration technologies are critically needed for the manufacturing of heat rejection system (HRS) components for current and future space exploration missions. Active metal brazing and adhesive bonding technologies are being assessed for the bonding of titanium to high conductivity Carbon-Carbon composite sub components in various shapes and sizes. Currently a number of different silver and copper based active metal brazes and adhesive compositions are being evaluated. The joint microstructures were examined using optical microscopy, and scanning electron microscopy (SEM) coupled with energy dispersive spectrometry (EDS). Several mechanical tests have been employed to ascertain the effectiveness of different brazing and adhesive approaches in tension and in shear that are both simple and representative of the actual system and relatively straightforward in analysis. The results of these mechanical tests along with the fractographic analysis will be discussed. In addition, advantages, technical issues and concerns in using different bonding approaches will also be presented.

Singh, M.↗

Controlled Formation of Zigzag and Armchair Edges in Graphene Nanoribbons by Joule Heating

We demonstrate and monitor an efficient edge reconstruction process, at the atomic scale, for graphite nanoribbons by Joule heating inside an integrated transmission electron microscope equipped with a scanning tunneling stage STM (TEM-STM system). During Joule annealing, sharp edges and step-edge arrays are formed, mostly with either zigzag or armchair edge configurations. Their formation is driven by both thermal and electric field related mechanisms. Model calculations show that the dominant annealing mechanisms involve point defect annealing and edge reconstruction. Joule heating is thus shown to provide an effective way to produce clean zigzag and armchair edges, which could be useful for both fundamental studies of edge reactivity, magnetism, and could provide a route for increasing carrier mobility and for the development of future electronics applications.

36 MATERIALS SCIENCE↗

Measuring the maximum capacity and thermal resistances in phase-change thermal storage devices

Thermal energy storage can increase the efficiency of the electric grid by adding flexibility to thermal systems. The value of thermal storage is a function of its energy and power density, which are driven by the capacity and thermal resistances in the storage device. Measuring these properties in-situ at the device level is an important step to understanding the performance and improving the design of thermal storage systems. Here, we present methods to measure the total capacity and thermal resistances in heat exchangers with integrated phase change materials. These methods are demonstrated on two thermal storage devices - a 570-kWh ice-based storage tank and a 0.35-kWh graphite-tetradecane composite device. The results show how thermal resistances evolve with the state of charge and discharge rate in these devices and quantify the impact of applied pressure on the contact resistance in composite phase change material heat exchangers. The proposed method allows for easy comparison between different systems and provides information on the thermal bottlenecks limiting performance. Ultimately, these measurements will allow designers to make robust, high-performance thermal storage devices for next-generation thermal systems.

25 ENERGY STORAGE↗

Heat transfer tests of an 0.006-scale thin-skin space shuttle model (41-OTS) in the Ames 3.5-foot HWT at M equals 5.3 (IH15)

Data obtained from heat transfer tests of an 0.006-scale space shuttle vehicle in a 3.5-foot hypersonic wind tunnel are presented. The purpose of these tests was to parametrically investigate the ascent heating of the integrated vehicle. Configurations tested were complete for integrated vehicle, orbiter alone, external tank alone, and SRB alone. All configurations were tested with and without transition grit. Testing was conducted at a Mach number of 5.3, and at Reynolds numbers of 2 and 5 million per foot. The angle of attack range varied from 0 to minus 5 degress, execpt for SRB alone, which was tested from minus 5 to 90 degrees. Heat transfer data were obtained from 223 iron-constantan thermocouples attached to thin-skin stainless steel inserts.

Walstad, D. G.↗

Heat Pipe Enhanced Thermal Management System for GaN Switches in an Integrated Modular Motor Drive for Aircraft Propulsion

This paper presents the process of sizing a heat pipe enhanced thermal management system (TMS) for GaN switches in an integrated modular motor drive (IMMD) powering a 250 kW aircraft propulsion electric motor. A test setup mimicking the TMS and GaN switches assembly is constructed. The condenser chamber of the TMS is modeled in ANSYS Fluent while the GaN switches assembly is modeled in ANSYS Thermal allowing us to verify heat spreader temperature under test conditions and estimate GaN temperatures under test and actual application operating conditions.

DIRECT ENERGY CONVERSION↗