At least 757 records · Page 42

Thermal test plan for large variable conductance heat pipe

The procedure to be followed in determining the thermal performance of a variable conductance heat pipe is documented. The nominal one-inch-diameter aluminum pipe is of a cold reservoir type whose overall length is nine feet. It has a capacity of 2 to 4 kW's equivalent to 8 to 16 kW-ft and an overall temperature control range of 50 to 95 F. Initial tests will be conducted with the pipe charged with ammonia to determine its capacity limits. Following introduction of the noncondensible gas (nitrogen), the variable conductance features of the pipe will be used.

Edelstein, F.↗

Heat pipe solar receiver with thermal energy storage

An HPSR Stirling engine generator system featuring latent heat thermal energy storge, excellent thermal stability and self regulating, effective thermal transport at low system delta T is described. The system was supported by component technology testing of heat pipes and of thermal storage and energy transport models which define the expected performance of the system. Preliminary and detailed design efforts were completed and manufacturing of HPSR components has begun.

Zimmerman, W. F.↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Crycooling↗

Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components in the 3K temperature range. A copper plate with attached electrical heaters was used to simulate the heat source, and heat was collected by the CLHP evaporator and transferred to the cryocooler for ultimate heat rejection. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully without pre-conditioning by simply applying power to both the capillary pump and the evaporator plate. It could adapt to rapid changes in the heat load, and reach a new steady state very quickly. Heat removal between 10mW and 140mW was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

cryocooling↗

Thermal Vacuum Testing of a Helium Loop Heat Pipe for Large Area Cryocooling

Future NASA space telescopes and exploration missions require cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks. One device that can potentially be used to provide closed-loop cryocooling is the cryogenic loop heat pipe (CLHP). A CLHP has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A helium CLHP has been tested extensively in a thermal vacuum chamber using a cryocooler as the heat sink to characterize its transient and steady performance and to verify its ability to cool large areas or components in the 3 degrees Kelvin temperature range. The helium CLHP thermal performance test included cool-down from the ambient temperature, startup, capillary limit, heat removal capability, rapid power changes, and long duration steady state operation. The helium CLHP demonstrated robust operation under steady state and transient conditions. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by simply applying power to both the capillary pump and the evaporator plate without pre-conditioning. It could adapt to a rapid heat load change and quickly reach a new steady state. Heat removal between 10 megawatts and 140 megawatts was demonstrated, yielding a power turn down ratio of 14. When the CLHP capillary limit was exceeded, the loop could resume its normal function by reducing the power to the capillary pump. Steady state operations up to 17 hours at several heat loads were demonstrated. The ability of the helium CLHP to cool large areas was therefore successfully verified.

Thermal Control Systems↗

Testing of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers for Space Applications

Thermal performance of a miniature loop heat pipe (MLHP) with two evaporators and two condensers is described. A comprehensive test program, including start-up, high power, low power, power cycle, and sink temperature cycle tests, has been executed at NASA Goddard Space Flight Center for potential space applications. Experimental data showed that the loop could start with heat loads as low as 2W. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of l00W to 120W, and could recover from a dry-out by reducing the heat load to evaporators. Low power test results showed the loop could work stably for heat loads as low as 1 W to each evaporator. Excellent adaptability of the MLHP to rapid changes of evaporator power and sink temperature were also demonstrated.

Nagano, Hosei↗

Heat pipe investigations

Techniques associated with thermal-vacuum and bench testing, along with flight testing of the OAO-C spacecraft heat pipes are outlined, to show that the processes used in heat transfer design and testing are adequate for good performance evaluations.

Marshburn, J. P.↗

Parametric performance of extruded axial grooved heat pipes from 100 to 300 K

Extensive performance data derived from tests with an aluminum axial grooved extruded heat pipe is presented for oxygen, methane, ethane, and ammonia as working fluids. The effects of operating temperature, fluid inventory, heat flux, and elevation on the transport capability and the evaporator and condenser film coefficients are measured and compared to theory. The data correlation indicates that, in addition to the viscous pressure drop of the fluid, a vapor induced liquid pressure drop must be taken into account at temperatures near or below the normal boiling point of the fluid. Methane, ethane, and ammonia are all suitable working fluids for this groove geometry; however, oxygen, because of its low static height, is at best marginal in the 100-120 K range.

Schlitt, K. R.↗

Use of heat pipes in electronic hardware

A modular, multiple output power converter was developed in order to reduce costs of space hardware in future missions. The converter is of reduced size and weight, and utilizes advanced heat removal techniques, in the form of heat pipes which remove internally generated heat more effectively than conventional methods.

Graves, J. R.↗

Autonomous control for Heat-Pipe microreactor using Data-Driven model predictive control

To enable a self-regulating capability for heat pipe (HP) microreactors, an anticipatory control strategy achieved via model predictive control (MPC) could proactively respond to potential disturbances and deviations in operating setpoints. This paper demonstrates data-driven methods for predicting the distribution and transient of temperatures and heat fluxes at selected components and regions in a 37-HP system, based on which the optimal control actions in response to changes in user-defined setpoints can be found. We present the development and validation of linear state-space model, feedfoward, and recurrent neural networks. Here, we compare the performance of MPCs with different modeling approaches in terms of following setpoints for temperatures and averaged output heat fluxes. The accuracies of the three data-driven models are similar, but the control actions initiated by neural-network-based MPC can better adapt to drastic changes in setpoints yet generate the smallest errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The use of finite element methods for determining the cross-sectional temperature distribution in heat pipes

A model that is currently used to predict the priming and performance limitations of a monogroove heat pipe is expanded to include the boiling limitation and the cross-sectional temperature distribution as determined from a multidimensional finite element analysis technique. The improved model is verified experimentally and shown to accurately predict the cross-sectional temperature distribution when the heat flux distribution is known. The model provides a way to estimate the level at which nucleate boiling and the associated dryout of the capillary wick occurs.

Peterson, G. P.↗

Orbiting Astronomical Observatory heat pipe flight performance data.

The paper describes preflight and inflight performance checkout of the three isothermalizer heat pipes onboard the OAO-C spacecraft. The three pipes are: an axially grooved pipe, a pedestal artery pipe, and a self-priming spiral artery pipe. All pipes are 1/2-inch diameter tube rolled into a 48-inch diameter hoop. They are constructed of aluminum and use ammonia as working fluid. Periodic inflight performance checks have been made since launch in August 1972. No degradation in performance of any of the pipes has been detected. The flight data are in excellent agreement with ground test data.

Harwell, W.↗

Development of electrical feedback controlled heat pipes and the advanced thermal control flight experiment

The development and characteristics of electrical feedback controlled heat pipes (FCHP) are discussed. An analytical model was produced to describe the performance of the FCHP under steady state and transient conditions. An advanced thermal control flight experiment was designed to demonstrate the performance of the thermal control component in a space environment. The thermal control equipment was evaluated on the ATS-F satellite to provide performance data for the components and to act as a thermal control system which can be used to provide temperature stability of spacecraft components in future applications.

Bienert, W. B.↗

Low Frequency High Amplitude Temperature Oscillations in Loop Heat Pipe Operation

This paper presents a theory that explains low frequency, high amplitude temperature oscillations in loop heat pipe (LHP) operation. Oscillations of the CC temperature with amplitudes on the order of tens of degrees Kelvin and periods on the order of hours have been observed in some LHPs during ambient testing. There are presently no satisfactory explanations for such a phenomenon in the literature. It is well-known that the operating temperature of an LHP with a single evaporator is governed by the compensation chamber (CC) temperature, which in turn is a function of the evaporator heat load, sink temperature, and ambient temperature. As the operating condition changes, the CC temperature will change during the transient but eventually reach a new steady temperature. Under certain conditions, however, the LHP never really reaches a true steady state, but instead displays an oscillatory behavior. The proposed new theory describes why low frequency, high amplitude oscillations may occur when the LHP has a low evaporator power, a low heat sink temperature (below ambient temperature), and a large thermal mass attached to the evaporator. When this condition prevails, there are some complex interactions between the CC, condenser, thermal mass and ambient. The temperature oscillation is a result of the large movement of the vapor front inside the condenser, which is caused by a change in the net evaporator power modulated by the large thermal mass through its interaction with the sink and CC. The theory agrees very well with previously published test data. Effects of various parameters on the amplitude and frequency of the temperature oscillation are also discussed.

Ku, Jentung↗